Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Michael Groth is active.

Publication


Featured researches published by Michael Groth.


Journal of Medical Imaging and Radiation Oncology | 2011

Diffusion‐weighted MR‐imaging for the detection of pulmonary nodules at 1.5 Tesla: Intraindividual comparison with multidetector computed tomography

Marc Regier; Dorothee Schwarz; Frank Oliver Henes; Michael Groth; Hendrik Kooijman; Philipp Gc Begemann; Gerhard Adam

Introduction: To investigate the feasibility of diffusion‐weighted imaging (DWI) MRI for detecting pulmonary nodules at 1.5 Tesla in comparison with standard multidetector computed tomography (MDCT).


European Journal of Radiology | 2012

Diffusion weighted MRI and 18F-FDG PET/CT in non-small cell lung cancer (NSCLC): Does the apparent diffusion coefficient (ADC) correlate with tracer uptake (SUV)?

Marc Regier; Thorsten Derlin; Dorothee Schwarz; Azien Laqmani; Frank Oliver Henes; Michael Groth; Jan-Hendrik Buhk; Hendrik Kooijman; Gerhard Adam

INTRODUCTION To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). MATERIALS AND METHODS 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm(2)) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV(mean)) and maximum (SUV(max)) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC(mean)) and minimum ADC (ADC(min)) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearsons correlation coefficient, Bland-Altman and regression analysis were assessed. RESULTS Data analysis revealed a significant inverse correlation of the ADC(min) and SUV(max) (r=-0.46; p=0.032). Testing the correlation of the ADC(min) and SUV(max) for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r=-0.47; p=0.03) and squamouscell carcinomas (r=-0.71; p=0.002), respectively. No significant correlation was found for the comparison of ADC(min) and SUV(mean) (r=-0.29; p=0.27), ADC(mean) vs. SUV(mean) (r=-0.28; p=0.31) or ADC(mean) vs. SUV(max) (r=-0.33; p=0.23). The κ-value of 0.88 indicated a good agreement between both observers. CONCLUSION This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC.


European Journal of Radiology | 2012

Comparison of diagnostic accuracy of Magnetic Resonance Imaging and Multidetector Computed Tomography in the detection of pelvic fractures.

Frank Oliver Henes; J.V. Nüchtern; Michael Groth; Christian R. Habermann; Marc Regier; Johannes M. Rueger; Gerhard Adam; L.G. Großterlinden

OBJECTIVE To compare diagnostic accuracy and interobserver reliability of Magnetic Resonance Imaging (MRI) and Multidetector Computed Tomography (MDCT) in the detection of acute pelvic fractures. MATERIALS AND METHODS In 38 consecutive patients (mean age 74.7 years) with a positive finding of anterior pelvis fracture in the conventional X-rays, pelvic MRI and MDCT were performed for further evaluation of pelvic ring fractures. Two radiologists independently read all data sets. Sensitivity and specificity were calculated based on mean scores for each method. Sensitivities of CT and MRI were compared using a paired proportion test (McNemar). Diagnostic validity of both methods was assessed by the interobserver variability using kappa statistics. Combined clinical data and findings from all imaging studies served as the reference standard. RESULTS 122 fractures were identified in the reference standard (37 sacral, 58 pubic, 22 acetabular, 1 ischial, 4 ilial). On average, MRI detected 96.3% whereas CT detected 77% of all fractures. With regard to sensitivity, MRI proved to be significantly better compared to MDCT (observer 1, p=0.0009; observer 2, p=0.0003 by observer 2). In particular, MRI performed better in the depiction of sacral fractures, reaching a sensitivity of 98.6% compared to 66.1% at CT. The interobserver variability was determined to be very good (k=0.955 for MRI and 0.902 for MDCT). CONCLUSION MRI reaches a significantly higher sensitivity than CT in the detection of acute pelvic fractures, particularly of the sacrum. Especially in elderly patients with suspicion of a sacral fracture and negative results at MDCT, MRI may be considered as the next step in diagnostic workup.


Journal of Cardiovascular Electrophysiology | 2013

Cardiovascular magnetic resonance demonstrates reversible atrial dysfunction after catheter ablation of persistent atrial fibrillation.

Kai Muellerleile; Michael Groth; Daniel Steven; Boris A. Hoffmann; Dennis Säring; Ulf K. Radunski; Gunnar K. Lund; Gerhard Adam; Thomas Rostock; Stephan Willems

There is a paucity of data on atrial injury following ablation of persistent atrial fibrillation (AF). This study aimed at assessing reversibility of atrial dysfunction after successful persistent AF ablation using cardiovascular magnetic resonance (CMR).


Journal of Cardiovascular Magnetic Resonance | 2012

Velocity encoded cardiovascular magnetic resonance to assess left atrial appendage emptying

Kai Muellerleile; Arian Sultan; Michael Groth; Daniel Steven; Boris A. Hoffmann; Gerhard Adam; Gunnar Lund; Thomas Rostock; Stephan Willems

BackgroundThe presence of impaired left atrial appendage (LAA) function identifies patients who are prone to thrombus formation in the LAA and therefore being at high risk for subsequent cardioembolic stroke. LAA function is typically assessed by measurements of LAA emptying velocities using transesophageal echocardiography (TEE) in clinical routine. This study aimed at evaluating the feasibility of assessing LAA emptying by velocity encoded (VENC) cardiovascular magnetic resonance (CMR).MethodsThis study included 30 patients with sinus rhythm (n = 18) or atrial fibrillation (n = 12). VENC-CMR velocity measurements were performed perpendicular to the orifice of the LAA. Peak velocities were measured of passive diastolic LAA emptying (e-wave) in all patients. Peak velocities of active, late-diastolic LAA emptying (a-wave) were assessed in patients with sinus rhythm. Correlation and agreement was analyzed between VENC-CMR and TEE measurements of e- and a-wave peak velocities.ResultsA significant correlation and good agreement was found between VENC-CMR and TEE measurements of maximal e-wave velocities (r = 0.61, P < 0.001; mean difference 0 ± 10 cm/s). The a-wave was detectable by VENC-CMR in all patients with sinus rhythm. Correlation was also significant for measurements of peak a-wave velocities between VENC-CMR and TEE (r = 0.71, P < 0.001). There was no significant correlation of LAA emptying velocities with clinical characteristics and only a modest negative correlation of passive LAA emptying with LA function.ConclusionsThe assessment of active and passive LAA emptying by VENC-CMR is feasible. Further evaluation is required of potential future clinical applications such as risk stratification for cardioembolic stroke.


European Journal of Radiology | 2012

Accuracy of thoracic aortic measurements assessed by contrast enhanced and unenhanced magnetic resonance imaging

Michael Groth; Frank Oliver Henes; Kai Müllerleile; Peter Bannas; Gerhard Adam; Marc Regier

AIM To assess, whether unenhanced balanced steady-state-free precession sequences provide axial thoracic aortic measurements comparable to contrast enhanced magnetic resonance angiography with good intra- and interobserver agreement. MATERIALS AND METHODS Enhanced and unenhanced sequences of the thoracic aorta in 23 consecutive patients were evaluated. Axial thoracic aortic diameters were measured at predefined levels by two independent readers. Pearsons correlation coefficient and Bland-Altman analysis were used to compare enhanced and unenhanced sequences. t-Test was used to determine possible significant differences between the measurements obtained by enhanced and unenhanced sequences. A p-value of less than .05 indicated statistical significance. Intraclass correlation coefficient and Bland-Altman were used for inter- and intraobserver correlation and agreement. RESULTS There was no significant difference in diameter measurements between enhanced and unenhanced sequences (ascending aorta, p=0.98; descending aorta, p=0.52). Bland-Altman revealed good agreement between enhanced and unenhanced sequences for ascending (mean bias, -0.01cm; with 95% limits of agreement, ±0.30cm) and descending aortic diameters (mean bias, 0.05cm; with 95% limits of agreement, ±0.30cm). Inter- and intraobserver agreement (mean bias, less than ±0.15; with 95% limits of agreement, less than ±0.42cm for all measurements) as well as correlation (r>0.8 for all measurements) were excellent. CONCLUSION Unenhanced balanced steady-state-free precession sequences enable rapid and accurate determination of axial thoracic aortic diameters with excellent inter- and intraobserver agreement, but without the risk of contrast media associated side-effects.


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2012

Improved agreement between experienced and inexperienced observers using a standardized evaluation protocol for cardiac volumetry and infarct size measurement.

Michael Groth; K. Muellerleile; T. Klink; D. Säring; S. Halaj; G. Folwarski; Michael G. Kaul; Peter Bannas; Gerhard Adam; Gunnar Lund

PURPOSE To study the agreement between experienced and inexperienced observers before and after training using a standardized evaluation protocol for cardiac magnetic resonance imaging (CMR) measurements of left ventricular (LV) volumes, mass and infarct size. MATERIALS AND METHODS First, 10 CMR studies from patients with myocardial infarction were analyzed by 2 experienced and 4 inexperienced observers in respect to end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), LV mass and infarct size. Subsequently, the inexperienced observers were trained using a standardized evaluation protocol. Thereafter, all observers analyzed another 10 CMR studies. RESULTS Before training the relative difference between experienced and inexperienced observers was -4.3±8.2% for EDV, -13.3±14.2% for ESV, 5.9±8.2% for EF, -12.2±10.9% for LV mass and -27.0±29.0% for infarct size in gram. After training, agreement significantly improved to 0.2±8.8% for EDV (p<0.05), -2.1±10.9 for ESV (p<0.01), 1.5±6.9% for EF (p<0.05), and -3.6±17.1% for infarct size (p<0.0001), but no improvement was seen for LV mass (-11.2±7.9, p=0.64). A slice based analysis showed, that the variable inclusion of the most basal and apical slices were mainly responsible for the low agreement of the measurements before training. CONCLUSION Training using a standardized evaluation protocol significantly improved the agreement between experienced and inexperienced observers for important CMR parameters. The proposed evaluation protocol can be used for training to improve the reproducibility of CMR measurements.


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2011

Intraindividual comparison of contrast-enhanced MRI and unenhanced SSFP sequences of stenotic and non-stenotic pulmonary artery diameters.

Michael Groth; Frank Oliver Henes; Peter Bannas; K. Muellerleile; Gerhard Adam; Marc Regier

PURPOSE To evaluate the agreement of pulmonary artery diameters assessed with 3D contrast-enhanced MR angiography (CE-MRA) and a 2D balanced steady-state-free precession sequence (bSSFP) in non-stenotic and stenotic pulmonary arteries (PA). METHODS AND MATERIALS 44 right and left PAs (30 non-stenotic and 14 stenotic) were examined in 23 consecutive patients by performing CE-MRA as well as bSSFP. Two independent readers determined the transverse diameters of the PA. RESULTS No significant difference in diameter measurements was found between CE-MRA and bSSFP (p = 0.8608 for the stenotic and p = 0.6208 for the non-stenotic PA). Bland-Altman analysis revealed good agreement between CE-MRA and bSSFP for both the non-stenotic (mean bias, 0.07 cm; with 95 % limits of agreement, ± 0.34 cm) and the stenotic (mean bias, 0.05 cm; with 95 % limits of agreement, ± 0.30 cm) PA. CONCLUSION bSSFP allows rapid and accurate determination of PA diameters without the use of ionizing radiation and the risk of contrast media-associated side-effects.


International Journal of Cardiology | 2013

Assessment of aortic root dimensions in patients with suspected Marfan syndrome: intraindividual comparison of contrast-enhanced and non-contrast magnetic resonance angiography with echocardiography.

Peter Bannas; Michael Groth; Meike Rybczynski; Sara Sheikhzadeh; Yskert von Kodolitsch; Joachim Graessner; Gunnar Lund; Gerhard Adam; Christian R. Habermann

PURPOSE Our purpose was to evaluate intraindividually the performance of contrast-enhanced magnetic resonance angiography (MRA) and non-contrast MRA for aortic root diameter measurements and to compare the results with routinely performed echocardiography in patients with suspected Marfan syndrome. METHODS AND MATERIALS Aortic roots were examined prospectively in 51 consecutive patients with suspected Marfan syndrome by using contrast-enhanced MRA and non-contrast MRA at 1.5 T. Two readers independently measured aortic root diameters at the annulus, sinuses of Valsalva and sinutubular junction in both data sets and compared results with echocardiographic data. Intraclass correlation coefficient, Pearson correlation coefficient, Bland-Altman, and two-sided t-test were used to assess agreement between observers and methods. RESULTS 38 (74.5%) of the 51 patients (25 female, 26 male; mean age 37.1 ± 13.7 years) had Marfan syndrome. Both, contrast-enhanced MRA and non-contrast MRA measurements of the sinuses of Valsalva revealed a strong correlation with echocardiography (r=0.850 and r=0.893, respectively). Intraclass correlation was markedly better for non-enhanced MRA (r=0.904) when compared to contrast-enhanced MRA (r=0.690). Image quality (p<0.001) as well as interobserver agreement (p<0.0042) of measurements of the sinuses of Valsalva was significantly better for non-enhanced MRA than for contrast-enhanced MRA. CONCLUSION Non-contrast MRA was more reliable and more valid than contrast-enhanced MRA for assessment of aortic root dimensions in patients with suspected Marfan syndrome. Therefore contrast agents can be omitted for establishing the diagnosis of aortic involvement in Marfan syndrome.


Emergency Radiology | 2010

Correlation of right ventricular dysfunction parameters and pulmonary vascular obstruction score in acute pulmonary embolism in a porcine model

Michael Groth; Frank Oliver Henes; Kai Müllerleile; Gerhard Adam; Philipp G. C. Begemann; Marc Regier

This paper aims to non-invasively determine right ventricular dysfunction parameters (RVDP) in acute pulmonary embolism (APE) and to correlate these parameters with a computed tomography (CT)-based pulmonary artery obstruction score (OS). In seven domestic pigs, magnetic resonance imaging (MRI) was performed before (n = 7) and after (n = 5) APE was induced. Analysis of relative changes in right ventricular stroke volume (RVSV%), output (RVO%), end-systolic (RVESV%), end-diastolic volume (RVEDV%), and heart rate (HR%) was performed. Additionally, for the determination of the OS, all animals underwent contrast-enhanced CT–pulmonary angiography. The CT-based OS correlated strongly with RVSV% (r = 0.9576; p = 0.0104) and RVO% (r = 0.9703; p = 0.0061). Contrarily, almost no correlation could be demonstrated for the OS and the increase of RVESV % (r = 0.3850; p = 0.5222), RVEDV% (r = 0.1830; p = 0.7683), and HR% (r = 0.5494; p = 0.3375). The results of this experimental study underline that the CT-based OS correlates with RVDP as determined by cardiac MRI and might be a helpful tool for the severity assessment in APE.

Collaboration


Dive into the Michael Groth's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge