The Lancet | 1998

Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II)

Patrick W. Serruys; Ben van Hout; Hans Bonnier; Victor Legrand; Eulogio García; Carlos Macaya; Eduardo Sousa; Wim Der Van Giessen; Antonio Colombo; Ricardo Seabra-Gomes; Ferdinand Kiemeneij; Peter Ruygrok; John Ormiston; Håkan Emanuelsson; Jean Fajadet; Michael Haude; Silvio Klugmann; Marie Angèle Morel

BACKGROUND The multicentre, randomised Benestent-II study investigated a strategy of implantation of a heparin-coated Palmar-Schatz stent plus antiplatelet drugs compared with the use of balloon angioplasty in selected patients with stable or stabilised unstable angina, with one or more de-novo lesions, less than 18 mm long, in vessels of diameter 3 mm or more. METHODS 827 patients were randomly assigned stent implantation (414 patients) or standard balloon angioplasty (413 patients). The primary clinical endpoint was event-free survival at 6 months, including death, myocardial infarction, and the need for revascularisation. The secondary endpoints were the restenosis rate at 6 months and the cost-effectiveness at 12 months. There was also one-to-one subrandomisation to either clinical and angiographic follow-up or clinical follow-up alone. Analyses were by intention to treat. FINDINGS Four patients (one stent group, three angioplasty group) were excluded from analysis since no lesion was found. At 6 months, a primary clinical endpoint had occurred in 53 (12.8%) of 413 patients in the stent group and 79 (19.3%) of 410 in the angioplasty group (p=0.013). This significant difference in clinical outcome was maintained at 12 months. In the subgroup assigned angiographic follow-up, the mean minimum lumen diameter was greater in the stent group than in the balloon-angioplasty group, (1.89 [SD 0.65] vs 1.66 [0.57] mm, p=0.0002), which corresponds to restenosis rates (diameter stenosis > or =50%) of 16% and 31% (p=0.0008). In the group assigned clinical follow-up alone, event-free survival rate at 12 months was higher in the stent group than the balloon-angioplasty group (0.89 vs 0.79, p=0.004) at a cost of an additional 2085 Dutch guilders (US


The Lancet | 2007

Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial

Raimund Erbel; Carlo Di Mario; Jozef Bartunek; Johann Bonnier; Bernard De Bruyne; Franz R. Eberli; Paul Erne; Michael Haude; Bernd Heublein; Mark Horrigan; Charles Ilsley; Dirk Böse; Jacques J. Koolen; Thomas F. Lüscher; Neil J. Weissman; Ron Waksman

1020) per patient. INTERPRETATION Over 12-month follow-up, a strategy of elective stenting with heparin-coated stents is more effective but also more costly than balloon angioplasty.


The Lancet | 2015

A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial

Patrick W. Serruys; Bernard Chevalier; Dariusz Dudek; Angel Cequier; Didier Carrié; Andrés Iñiguez; Marcello Dominici; René J van der Schaaf; Michael Haude; Luc Wasungu; Susan Veldhof; Lei Peng; Peter Staehr; Maik J. Grundeken; Yuki Ishibashi; Hector M. Garcia-Garcia; Yoshinobu Onuma

BACKGROUND Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.


Circulation | 2009

Coronary Microembolization From Bedside to Bench and Back to Bedside

Gerd Heusch; Petra Kleinbongard; Dirk Böse; Bodo Levkau; Michael Haude; Rainer Schulz; Raimund Erbel

BACKGROUND Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart are available. In a randomised controlled trial we aimed to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent. Here we report secondary clinical and procedural outcomes after 1 year of follow-up. METHODS In a single-blind, multicentre, randomised trial, we enrolled eligible patients aged 18-85 years with evidence of myocardial ischaemia and one or two de-novo native lesions in different epicardial vessels. We randomly assigned patients in a 2:1 ratio to receive treatment with an everolimus-eluting bioresorbable scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (Xience, Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetes status and number of planned target lesions. The co-primary endpoints of this study are vasomotion (change in mean lumen diameter before and after nitrate administration at 3 years) and difference between minimum lumen diameter (after nitrate administration) after the index procedure and at 3 years. Secondary endpoints were procedural performance assessed by quantitative angiography and intravascular ultrasound; composite clinical endpoints based on death, myocardial infarction, and coronary revascularisation; device and procedural success; and angina status assessed by the Seattle Angina Questionnaire and exercise testing at 6 and 12 months. Cumulative angina rate based on adverse event reporting was analysed post hoc. This trial is registered at ClinicalTrials.gov, number NCT01425281. FINDINGS Between Nov 28, 2011, and June 4, 2013, we enrolled 501 patients and randomly assigned them to the bioresorbable scaffold group (335 patients, 364 lesions) or the metallic stent group (166 patients, 182 lesions). Dilatation pressure and balloon diameter at the highest pressure during implantation or postdilatation were higher and larger in the metallic stent group, whereas the acute recoil post implantation was similar (0.19 mm for both, p=0.85). Acute lumen gain was lower for the bioresorbable scaffold by quantitative coronary angiography (1.15 mm vs 1.46 mm, p<0.0001) and quantitative intravascular ultrasound (2.85 mm(2)vs 3.60 mm(2), p<0.0001), resulting in a smaller lumen diameter or area post procedure. At 1 year, however, cumulative rates of first new or worsening angina from adverse event reporting were lower (72 patients [22%] in the bioresorbable scaffold group vs 50 [30%] in the metallic stent group, p=0.04), whereas performance during maximum exercise and angina status by SAQ were similar. The 1-year composite device orientated endpoint was similar between the bioresorbable scaffold and metallic stent groups (16 patients [5%] vs five patients [3%], p=0.35). Three patients in the bioresorbable scaffold group had definite or probable scaffold thromboses (one definite acute, one definite sub-acute, and one probable late), compared with no patients in the metallic stent group. There were 17 (5%) major cardiac adverse events in the bioresorbable scaffold group compared with five (3%) events in the metallic stent group, with the most common adverse events being myocardial infarction (15 cases [4%] vs two cases [1%], respectively) and clinically indicated target-lesion revascularisation (four cases [1%] vs three cases [2%], respectively). INTERPRETATION The everolimus-eluting bioresorbable scaffold showed similar 1-year composite secondary clinical outcomes to the everolimus-eluting metallic stent. FUNDING Abbott Vascular.


Journal of the American College of Cardiology | 1997

Comparison of Electron Beam Computed Tomography With Intracoronary Ultrasound and Coronary Angiography for Detection of Coronary Atherosclerosis

Dietrich Baumgart; Axel Schmermund; Guenter Goerge; Michael Haude; Junbo Ge; Michael Adamzik; Cornelia Sehnert; Klaus Altmaier; Dietrich H W Groenemeyer; Rainer Seibel; Raimund Erbel

Coronary microembolization from the erosion or rupture of a vulnerable atherosclerotic plaque occurs spontaneously in acute coronary syndromes and iatrogenically during percutaneous coronary interventions. Typical consequences of coronary microembolization are microinfarcts with an inflammatory response, contractile dysfunction, and reduced coronary reserve. Apart from transient elevations of creatine kinase and troponin, microemboli can be visualized by intracoronary Doppler and the resulting microinfarcts by late-enhancement nuclear magnetic resonance. Statins, antiplatelet agents, and coronary vasodilators protect against microembolization and microinfarction when started before percutaneous coronary interventions. Distal protection devices can retrieve atherothrombotic debris and prevent its embolization into the microcirculation, but their effect on clinical outcome has been disappointing so far, except for saphenous vein bypass grafts. Devices for aspiration of thrombi and thrombus-derived vasoconstrictor, thrombogenic, and inflammatory substances, however, reduce thrombus burden, improve perfusion, and provide protection in patients with acute myocardial infarction.


Circulation | 1997

Prognostic value of intracoronary flow velocity and diameter stenosis in assessing the short- and long-term outcomes of coronary balloon angioplasty - The DEBATE study (Doppler Endpoints Balloon Angioplasty Trial Europe)

P. W. Serruys; C. Di Mario; Jan J. Piek; Erwin Schroeder; Ch. Vrints; Peter Probst; B. De Bruyne; Claude Hanet; Eckart Fleck; Michael Haude; Edoardo Verna; Vasilis Voudris; H Geschwind; Håkan Emanuelsson; V. Muhlberger; G. Danzi; Ho Peels; A.J. Ford jr; Eric Boersma

OBJECTIVES This analysis compared the results of electron beam computed tomography (EBCT) with those of coronary angiography and intracoronary ultrasound (ICUS) for the in vivo detection of coronary atherosclerotic plaques. BACKGROUND EBCT is a new imaging modality for identification of coronary calcifications. Coronary angiography depicts advanced changes in coronary morphology, whereas ICUS is an established diagnostic tool that detects the early stages of coronary artery disease. METHODS In 57 patients (54 +/- 9 years old), 267 coronary segments were analyzed with EBCT (3-mm slices, acquisition time 100 ms, threshold definition of coronary calcification at 130 Hounsfield units in an area > or = 1 mm2, Agatston calcium score), coronary angiography and ICUS. The analysis was based on the number and extent of coronary calcifications on EBCT, coronary lumen reduction on coronary angiography and plaque formation with and without ultrasound signs of calcifications on ICUS. RESULTS Compared with coronary angiography, EBCT yielded a sensitivity of 66%, a specificity of 78%, a positive predictive value of 39% and a negative predictive value of 91%. Compared with ICUS, EBCT yielded an overall sensitivity of 66%, a specificity of 88% and an overall accuracy of 81%. For plaques with and without ultrasound signs of calcifications, the sensitivity of EBCT was 97% and 47%, specificity 80% and 75% and overall accuracy 82% and 69%, respectively. CONCLUSIONS This in vivo correlation between ICUS and EBCT demonstrates that EBCT is a noninvasive method that helps to visualize the atherosclerotic process by localization and quantification of coronary artery calcifications. EBCT detects calcified plaques with high accuracy. Plaques without ultrasound signs of calcifications can be detected by EBCT but with lower sensitivity but equivalent specificity.


The New England Journal of Medicine | 1998

Coronary-artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty. Restenosis Stent Study Group.

Raimund Erbel; Michael Haude; Hans Wilhelm Höpp; Damian Franzen; Hans-Jürgen Rupprecht; Bernd Heublein; Patrick W. Serruys; Wolfgang Rutsch; Peter Probst; Peter de Jaegere; Klaus Fischer

BACKGROUND The aim of this prospective, multicenter study was the identification of Doppler flow velocity measurements predictive of clinical outcome of patients undergoing single-vessel balloon angioplasty with no previous Q-wave myocardial infarction. METHODS AND RESULTS In 297 patients, a Doppler guidewire was used to measure basal and maximal hyperemic flow velocities proximal and distal to the stenosis before and after angioplasty. In 225 patients with an angiographically successful percutaneous transluminal coronary angioplasty (PTCA), postprocedural distal coronary flow reserve (CFR) and percent diameter stenosis (DS%) were correlated with symptoms and/or ischemia at 1 and 6 months, with the need for target lesion revascularization, and with angiographic restenosis (defined as DS > or = 50% at follow-up). Logistic regression and receiver operator characteristic curve analyses were applied to determine the prognostic cutoff value of CFR and DS separately and in combination. Optimal cutoff criteria for predictors of these clinical events were DS, 35%; CFR, 2.5. A distal CFR after angioplasty > 2.5 with a residual DS < or = 35% identified lesions with a low incidence of recurrence of symptoms at 1 month (10% versus 19%, P=.149) and at 6 months (23% versus 47%, P=.005), a low need for reintervention (16% versus 34%, P=.024), and a low restenosis rate (16% versus 41%, P=.002) compared with patients who did not meet these criteria. CONCLUSIONS Measurements of distal CFR after PTCA, in combination with DS%, have a predictive value, albeit modest for the short- and long-term outcomes after PTCA, and thus may be used to identify patients who will or will not benefit from additional therapy such as stent implantation.


Circulation | 2006

High-Density Lipoproteins and Their Constituent, Sphingosine-1-Phosphate, Directly Protect the Heart Against Ischemia/Reperfusion Injury In Vivo via the S1P3 Lysophospholipid Receptor

Gregor Theilmeier; Christoph Schmidt; Jörg Herrmann; Petra Keul; Michael Schäfers; Ilka Herrgott; Jan Mersmann; Jan Larmann; Sven Hermann; Jörg Stypmann; Otmar Schober; Reinhard Hildebrand; Rainer Schulz; Gerd Heusch; Michael Haude; Karin von Wnuck Lipinski; Christine Herzog; Martina Schmitz; Raimund Erbel; Jerold Chun; Bodo Levkau

BACKGROUND Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.


Circulation | 2009

Percutaneous Mitral Annuloplasty for Functional Mitral Regurgitation: Results of the CARILLON Mitral Annuloplasty Device European Union Study

Joachim Schofer; Tomasz Siminiak; Michael Haude; Jean Paul R Herrman; Jindra Vainer; Justina C. Wu; Wayne C. Levy; Laura Mauri; Ted Feldman; Raymond Y. Kwong; David M. Kaye; S. Duffy; Thilo Tübler; Hubertus Degen; Mathias C. Brandt; Rich Van Bibber; Steve Goldberg; David G. Reuter; Uta C. Hoppe

Background— All treatments of acute myocardial infarction are aimed at rapid revascularization of the occluded vessel; however, no clinical strategies are currently available to protect the heart from ischemia/reperfusion injury after restitution of blood flow. We hypothesized that some of the cholesterol transport–independent biological properties of high-density lipoprotein (HDL) implied in atheroprotection may also be beneficial in settings of acute myocardial reperfusion injury. Methods and Results— In an in vivo mouse model of myocardial ischemia/reperfusion, we observed that HDL and its sphingolipid component, sphingosine-1-phosphate (S1P), dramatically attenuated infarction size by ≈20% and 40%, respectively. The underlying mechanism was an inhibition of inflammatory neutrophil recruitment and cardiomyocyte apoptosis in the infarcted area. In vitro, HDL and S1P potently suppressed leukocyte adhesion to activated endothelium under flow and protected rat neonatal cardiomyocytes against apoptosis. In vivo, HDL- and S1P-mediated cardioprotection was dependent on nitric oxide (NO) and the S1P3 lysophospholipid receptor, because it was abolished by pharmacological NO synthase inhibition and was completely absent in S1P3-deficient mice. Conclusions— Our data demonstrate that HDL and its constituent, S1P, acutely protect the heart against ischemia/reperfusion injury in vivo via an S1P3-mediated and NO-dependent pathway. A rapid therapeutic elevation of S1P-containing HDL plasma levels may be beneficial in patients at high risk of acute myocardial ischemia.


Journal of the American College of Cardiology | 2001

Plaque Distribution and Vascular Remodeling of Ruptured and Nonruptured Coronary Plaques in the Same Vessel: An Intravascular Ultrasound Study In Vivo

Clemens von Birgelen; Wolfgang Klinkhart; Gary S. Mintz; Alexandra Papatheodorou; Jörg Herrmann; Dietrich Baumgart; Michael Haude; Heinrich Wieneke; Junbo Ge; Raimund Erbel

Background— Functional mitral regurgitation (FMR), a well-recognized component of left ventricular remodeling, is associated with increased morbidity and mortality in heart failure patients. Percutaneous mitral annuloplasty has the potential to serve as a therapeutic adjunct to standard medical care. Methods and Results— Patients with dilated cardiomyopathy, moderate to severe FMR, an ejection fraction <40%, and a 6-minute walk distance between 150 and 450 m were enrolled in the CARILLON Mitral Annuloplasty Device European Union Study (AMADEUS). Percutaneous mitral annuloplasty was achieved through the coronary sinus with the CARILLON Mitral Contour System. Echocardiographic FMR grade, exercise tolerance, New York Heart Association class, and quality of life were assessed at baseline and 1 and 6 months. Of the 48 patients enrolled in the trial, 30 received the CARILLON device. Eighteen patients did not receive a device because of access issues, insufficient acute FMR reduction, or coronary artery compromise. The major adverse event rate was 13% at 30 days. At 6 months, the degree of FMR reduction among 5 different quantitative echocardiographic measures ranged from 22% to 32%. Six-minute walk distance improved from 307±87 m at baseline to 403±137 m at 6 months (P<0.001). Quality of life, measured by the Kansas City Cardiomyopathy Questionnaire, improved from 47±16 points at baseline to 69±15 points at 6 months (P<0.001). Conclusions— Percutaneous reduction in FMR with a novel coronary sinus-based mitral annuloplasty device is feasible in patients with heart failure, is associated with a low rate of major adverse events, and is associated with improvement in quality of life and exercise tolerance.

Collaboration


Dive into the Michael Haude's collaboration.

Top Co-Authors

Avatar

Raimund Erbel

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Dietrich Baumgart

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Holger Eggebrecht

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dirk Böse

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Heinrich Wieneke

University of Duisburg-Essen

View shared research outputs
Researchain Logo
Decentralizing Knowledge