Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Michael Kovochich is active.

Publication


Featured researches published by Michael Kovochich.


ACS Nano | 2008

Comparison of the mechanism of toxicity of zinc oxide and cerium oxide nanoparticles based on dissolution and oxidative stress properties.

Tian Xia; Michael Kovochich; Monty Liong; Lutz Mädler; Benjamin Gilbert; Haibin Shi; Joanne I. Yeh; Jeffrey I. Zink; Andre E. Nel

Nanomaterials (NM) exhibit novel physicochemical properties that determine their interaction with biological substrates and processes. Three metal oxide nanoparticles that are currently being produced in high tonnage, TiO(2), ZnO, and CeO(2), were synthesized by flame spray pyrolysis process and compared in a mechanistic study to elucidate the physicochemical characteristics that determine cellular uptake, subcellular localization, and toxic effects based on a test paradigm that was originally developed for oxidative stress and cytotoxicity in RAW 264.7 and BEAS-2B cell lines. ZnO induced toxicity in both cells, leading to the generation of reactive oxygen species (ROS), oxidant injury, excitation of inflammation, and cell death. Using ICP-MS and fluorescent-labeled ZnO, it is found that ZnO dissolution could happen in culture medium and endosomes. Nondissolved ZnO nanoparticles enter caveolae in BEAS-2B but enter lysosomes in RAW 264.7 cells in which smaller particle remnants dissolve. In contrast, fluorescent-labeled CeO(2) nanoparticles were taken up intact into caveolin-1 and LAMP-1 positive endosomal compartments, respectively, in BEAS-2B and RAW 264.7 cells, without inflammation or cytotoxicity. Instead, CeO(2) suppressed ROS production and induced cellular resistance to an exogenous source of oxidative stress. Fluorescent-labeled TiO(2) was processed by the same uptake pathways as CeO(2) but did not elicit any adverse or protective effects. These results demonstrate that metal oxide nanoparticles induce a range of biological responses that vary from cytotoxic to cytoprotective and can only be properly understood by using a tiered test strategy such as we developed for oxidative stress and adapted to study other aspects of nanoparticle toxicity.


ACS Nano | 2008

Multifunctional Inorganic Nanoparticles for Imaging, Targeting, and Drug Delivery

Monty Liong; Jie Lu; Michael Kovochich; Tian Xia; Stefan G. Ruehm; Andre E. Nel; Fuyuhiko Tamanoi; Jeffrey I. Zink

Drug delivery, magnetic resonance and fluorescence imaging, magnetic manipulation, and cell targeting are simultaneously possible using a multifunctional mesoporous silica nanoparticle. Superparamagnetic iron oxide nanocrystals were encapsulated inside mesostructured silica spheres that were labeled with fluorescent dye molecules and coated with hydrophilic groups to prevent aggregation. Water-insoluble anticancer drugs were delivered into human cancer cells; surface conjugation with cancer-specific targeting agents increased the uptake into cancer cells relative to that in non-cancerous fibroblasts. The highly versatile multifunctional nanoparticles could potentially be used for simultaneous imaging and therapeutic applications.


ACS Nano | 2009

Polyethyleneimine Coating Enhances the Cellular Uptake of Mesoporous Silica Nanoparticles and Allows Safe Delivery of siRNA and DNA Constructs

Tian Xia; Michael Kovochich; Monty Liong; Huan Meng; Sanaz Kabehie; Saji George; Jeffrey I. Zink; Andre E. Nel

Surface-functionalized mesoporous silica nanoparticles (MSNP) can be used as an efficient and safe carrier for bioactive molecules. In order to make the MSNP a more efficient delivery system, we modified the surface of the particles by a functional group that enhances cellular uptake and allows nucleic acid delivery in addition to traditional drug delivery. Noncovalent attachment of polyethyleneimine (PEI) polymers to the surface not only increases MSNP cellular uptake but also generates a cationic surface to which DNA and siRNA constructs could be attached. While efficient for intracellular delivery of these nucleic acids, the 25 kD PEI polymer unfortunately changes the safety profile of the MSNP that is otherwise very safe. By experimenting with several different polymer molecular weights, it was possible to retain high cellular uptake and transfection efficiency while reducing or even eliminating cationic MSNP cytotoxicity. The particles coated with the 10 kD PEI polymer were particularly efficient for transducing HEPA-1 cells with a siRNA construct that was capable of knocking down GFP expression. Similarly, transfection of a GFP plasmid induced effective expression of the fluorescent protein in >70% cells in the population. These outcomes were quantitatively assessed by confocal microscopy and flow cytometry. We also demonstrated that the enhanced cellular uptake of the nontoxic cationic MSNP enhances the delivery of the hydrophobic anticancer drug, paclitaxel, to pancreatic cancer cells. In summary, we demonstrate that, by a careful selection of PEI size, it is possible to construct cationic MSNP that are capable of nucleotide and enhanced drug delivery with minimal or no cytotoxicity. This novel use of a cationic MSNP extends its therapeutic use potential.


ACS Nano | 2008

Cationic polystyrene nanosphere toxicity depends on cell-specific endocytic and mitochondrial injury pathways.

Tian Xia; Michael Kovochich; Monty Liong; Jeffrey I. Zink; Andre E. Nel

The exponential increase in the number of new nanomaterials that are being produced increases the likelihood of adverse biological effects in humans and the environment. In this study we compared the effects of cationic nanoparticles in five different cell lines that represent portal-of-entry or systemic cellular targets for engineered nanoparticles. Although 60 nm NH(2)-labeled polystyrene (PS) nanospheres were highly toxic in macrophage (RAW 264.7) and epithelial (BEAS-2B) cells, human microvascular endothelial (HMEC), hepatoma (HEPA-1), and pheochromocytoma (PC-12) cells were relatively resistant to particle injury. While the death pathway in RAW 264.7 cells involves caspase activation, the cytotoxic response in BEAS-2B cells is more necrotic in nature. Using fluorescent-labeled NH(2)-PS, we followed the routes of particle uptake. Confocal microscopy showed that the cationic particles entered a LAMP-1 positive lysosomal compartment in RAW 264.7 cells from where the particles could escape by lysosomal rupture. A proton pump inhibitor interfered in this pathway. Subsequent deposition of the particles in the cytosol induced an increase in mitochondrial Ca(2+) uptake and cell death that could be suppressed by cyclosporin A (CsA). In contrast, NH(2)-PS toxicity in BEAS-2B cells did not involve the LAMP-1 endosomal compartment, stimulation of proton pump activity, or an increase in mitochondrial Ca(2+). Particles were taken up by caveolae, and their toxicity could be disrupted by cholesterol extraction from the surface membrane. Although the particles induced mitochondrial damage and ATP depletion, CsA did not affect cytotoxicity. Cationic particles were taken up into HEPA-1, HMEC, and PC-12 cells, but this did not lead to lysosomal permeabilization, increased Ca(2+) flux, or mitochondrial damage. Taken together, the results of this study demonstrate the importance of cell-specific uptake mechanisms and pathways that could lead to sensitivity or resistance to cationic particle toxicity.


Journal of Virology | 2012

HIV Latency in the Humanized BLT Mouse

Matthew D. Marsden; Michael Kovochich; Nuttee Suree; Saki Shimizu; Roshni Mehta; Ruth Cortado; Gregory Bristol; Dong Sung An; Jerome A. Zack

ABSTRACT Even after extended treatment with powerful antiretroviral drugs, HIV is not completely eliminated from infected individuals. Latently infected CD4+ T cells constitute one reservoir of replication-competent HIV that needs to be eliminated to completely purge virus from antiretroviral drug-treated patients. However, a major limitation in the development of therapies to eliminate this latent reservoir is the lack of relevant in vivo models that can be used to test purging strategies. Here, we show that the humanized BLT (bone marrow-liver-thymus) mouse can be used as both an abundant source of primary latently infected cells for ex vivo latency analysis and also as an in vivo system for the study of latency. We demonstrate that over 2% of human cells recovered from the spleens of HIV-infected BLT mice can be latently infected and that this virus is integrated, activation inducible, and replication competent. The non-tumor-inducing phorbol esters prostratin and 12-deoxyphorbol-13-phenylacetate can each induce HIV ex vivo from these latently infected cells, indicating that this model can be used as a source of primary cells for testing latency activators. Finally, we show activation-inducible virus is still present following suppression of plasma viral loads to undetectable levels by using the antiretroviral drugs zidovudine, indinavir sulfate, and didanosine, demonstrating that this model can also be used to assess the in vivo efficacy of latency-purging strategies. Therefore, the HIV-infected BLT mouse should provide a useful model for assessment of HIV latency activators and approaches to eliminate persistent in vivo HIV reservoirs.


PLOS ONE | 2011

Activation of Latent HIV Using Drug-Loaded Nanoparticles

Michael Kovochich; Matthew D. Marsden; Jerome A. Zack

Antiretroviral therapy is currently only capable of controlling HIV replication rather than completely eradicating virus from patients. This is due in part to the establishment of a latent virus reservoir in resting CD4+ T cells, which persists even in the presence of HAART. It is thought that forced activation of latently infected cells could induce virus production, allowing targeting of the cell by the immune response. A variety of molecules are able to stimulate HIV from latency. However no tested purging strategy has proven capable of eliminating the infection completely or preventing viral rebound if therapy is stopped. Hence novel latency activation approaches are required. Nanoparticles can offer several advantages over more traditional drug delivery methods, including improved drug solubility, stability, and the ability to simultaneously target multiple different molecules to particular cell or tissue types. Here we describe the development of a novel lipid nanoparticle with the protein kinase C activator bryostatin-2 incorporated (LNP-Bry). These particles can target and activate primary human CD4+ T-cells and stimulate latent virus production from human T-cell lines in vitro and from latently infected cells in a humanized mouse model ex vivo. This activation was synergistically enhanced by the HDAC inhibitor sodium butyrate. Furthermore, LNP-Bry can also be loaded with the protease inhibitor nelfinavir (LNP-Bry-Nel), producing a particle capable of both activating latent virus and inhibiting viral spread. Taken together these data demonstrate the ability of nanotechnological approaches to provide improved methods for activating latent HIV and provide key proof-of-principle experiments showing how novel delivery systems may enhance future HIV therapy.


Nanomedicine: Nanotechnology, Biology and Medicine | 2015

Toxicology of wear particles of cobalt-chromium alloy metal-on-metal hip implants Part I: Physicochemical properties in patient and simulator studies

Amy K. Madl; Monty Liong; Michael Kovochich; Brent L. Finley; Dennis J. Paustenbach; Günter Oberdörster

UNLABELLED The objective of Part I of this analysis was to identify the relevant physicochemical characteristics of wear particles from cobalt-chromium alloy (CoCr) metal-on-metal (MoM) hip implant patients and simulator systems. For well-functioning MoM hip implants, the volumetric wear rate is low (<1mm(3) per million cycles or per year) and the majority of the wear debris is composed of oxidized Cr nanoparticles (<100nm) with minimal or no Co content. For implants with surgical malpositioning, the volumetric wear rate is as high as 100mm(3) per million cycles or per year and the size distribution of wear debris can be skewed to larger sizes (up to 1000nm) and contain higher concentrations of Co. In order to obtain data suitable for a risk assessment of wear debris in MoM hip implant patients, future studies need to focus on particle characteristics relevant to those generated in patients or in properly conducted simulator studies. FROM THE CLINICAL EDITOR Metallic implants are very common in the field of orthopedics. Nonetheless, concerns have been raised about the implications of nano-sized particles generated from the wear of these implants. In this two-part review, the authors first attempted to identify and critically evaluate the relevant physicochemical characteristics of CoCr wear particles from hip implant patients and simulator systems. Then they evaluated in vitro and animal toxicology studies with respect to the physicochemistry and dose-relevance to metal-on-metal implant patients.


Nanomedicine: Nanotechnology, Biology and Medicine | 2015

Toxicology of wear particles of cobalt-chromium alloy metal-on-metal hip implants Part II: Importance of physicochemical properties and dose in animal and in vitro studies as a basis for risk assessment

Amy K. Madl; Michael Kovochich; Monty Liong; Brent L. Finley; Dennis J. Paustenbach; Günter Oberdörster

The objective of the Part II analysis was to evaluate animal and in vitro toxicology studies of CoCr particles with respect to their physicochemistry and dose relevance to metal-on-metal (MoM) implant patients as derived from Part I. In the various toxicology studies, physicochemical characteristics were infrequently considered and administered doses were orders of magnitude higher than what occurs in patients. Co was consistently shown to rapidly release from CoCr particles for distribution and elimination from the body. CoCr micron sized particles appear more biopersistent in vivo resulting in inflammatory responses that are not seen with similar mass concentrations of nanoparticles. We conclude, that in an attempt to obtain data for a complete risk assessment, future studies need to focus on physicochemical characteristics of nano and micron sized particles and on doses and dose metrics relevant to those generated in patients or in properly conducted hip simulator studies.


Journal of Biomedical Materials Research Part B | 2018

Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions

Michael Kovochich; Ernest S. Fung; Ellen P. Donovan; Kenneth M. Unice; Dennis J. Paustenbach; Brent L. Finley

Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40° angle) and edge-loading (65° angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (<100 nm) to submicron (<1000 nm) size range, whereas edge-loading conditions generated particles that ranged from <100 nm up to 3000-6000 nm in size. Particles isolated from normal wear were primarily chromium (98.5%) and round to oval in shape. Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio ≥ 2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions.


Journal of Exposure Science and Environmental Epidemiology | 2017

Review of techniques and studies characterizing the release of carbon nanotubes from nanocomposites: Implications for exposure and human health risk assessment

Michael Kovochich; Cha-Chen David Fung; Raghavendhran Avanasi; Amy K. Madl

Composites made with engineered nanomaterials (nanocomposites) have a wide range of applications, from use in basic consumer goods to critical national defense technologies. Carbon nanotubes (CNTs) are a popular addition in nanocomposites because of their enhanced mechanical, thermal, and electrical properties. Concerns have been raised, though, regarding potential exposure and health risks from nanocomposites containing CNTs because of comparisons to other high aspect ratio fibers. Assessing the factors affecting CNT release from composites is therefore paramount for understanding potential exposure scenarios that may occur during product handling and manipulation. Standardized methods for detecting and quantifying released CNTs, however, have not yet been developed. We therefore evaluated experimental approaches deployed by various researchers, with an emphasis on characterizing free versus composite bound CNTs. From our analysis of published studies characterizing CNT releases from nanocomposites, we found that the qualitative and quantitative methods used across studies varied greatly, thus limiting the ability for objective comparison and evaluation of various release factors. Nonetheless, qualitative results indicated that factors such as composite type, CNT functionalization, and energy input during manipulation (i.e., grinding) may affect CNT release. Based on our findings, we offer several recommendations for future product testing and assessment of potential exposure and health risks associated with CNT nanocomposites.

Collaboration


Dive into the Michael Kovochich's collaboration.

Top Co-Authors

Avatar

Andre E. Nel

University of California

View shared research outputs
Top Co-Authors

Avatar

Tian Xia

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jie Lu

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge