Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Michael Schultz is active.

Publication


Featured researches published by Michael Schultz.


Ultrasound in Medicine and Biology | 2012

IN VIVO TIME HARMONIC ELASTOGRAPHY OF THE HUMAN HEART

Heiko Tzschätzsch; Thomas Elgeti; Katrin Rettig; Christian Kargel; Robert Klaua; Michael Schultz; Jürgen Braun; Ingolf Sack

Time harmonic elastography is introduced as a modality for assessing myocardial elasticity changes during the cardiac cycle. It is based on external stimulation and real-time analysis of 30-Hz harmonic shear waves in axial direction of a parasternal line of sight through the lateral heart wall. In 20 healthy volunteers, the externally induced waves showed smaller amplitudes during systole (76.0 ± 30.8 μm) and higher amplitudes during diastole (126.7 ± 52.1 μm). This periodic wave amplitude alteration preceded ventricular contraction and dilation by about 100 ms. The amplitude ratio of 1.75 ± 0.49 indicates a relative change in myocardial shear elasticity on the order of 14 ± 11. These results well agree with observations made by cardiac magnetic resonance elastography for a similar displacement component and region of the heart. The proposed method provides reproducible elastodynamic information on the heart in real-time and may help in diagnosing myocardial relaxation abnormalities in the future.


Ultrasound in Medicine and Biology | 2015

Multifrequency Time-Harmonic Elastography for the Measurement of Liver Viscoelasticity in Large Tissue Windows

Heiko Tzschätzsch; Manh Nguyen Trong; Jing Guo; Jonathan Eggers; Enno Gentz; Thomas Fischer; Michael Schultz; Jürgen Braun; Ingolf Sack

Elastography of the liver for the non-invasive diagnosis of hepatic fibrosis is an established method. However, investigations of obese patients or patients with ascites are often limited by small and superficial elastographic windows. Therefore, multifrequency time-harmonic elastography (THE) based on time-resolved A-line ultrasound has recently been developed for measuring liver viscoelasticity in wide soft tissue windows and at greater depths. In this study, THE was integrated into a clinical B-mode scanner connected to a dedicated actuator bed driven by superimposed vibrations of 30- to 60-Hz frequencies. The resulting shear waves in the liver were captured along multiple profiles 7 to 14 cm in width and automatically processed for reconstruction of mean efficient shear wave speed and shear wave dispersion slope. This new modality was tested in healthy volunteers and 22 patients with clinically proven cirrhosis. Patients could be separated from controls by higher shear wave speeds (3.11 ± 0.64 m/s, 2.14-4.81 m/s, vs. 1.74 ± 0.10 m/s, 1.60-1.91 m/s) without significant degradation of data by high body mass index or ascites. Furthermore, the wave speed dispersion slope was significantly (p = 0.0025) lower in controls (5.2 ± 1.8 m/s/kHz) than in patients (39.1 ± 32.2 m/s/kHz). In conclusion, THE is useful for the diagnosis of cirrhosis in large tissue windows.


Ultrasound in Medicine and Biology | 2013

Isovolumetric Elasticity Alteration in the Human Heart Detected by In Vivo Time-Harmonic Elastography

Heiko Tzschätzsch; Robert Hättasch; Fabian Knebel; Robert Klaua; Michael Schultz; Klaus-Vitold Jenderka; Jürgen Braun; Ingolf Sack

Time harmonic elastography (THE) has recently been introduced for measurement of the periodic alteration in myocardial shear modulus based on externally induced low-frequency acoustic vibrations produced by a loudspeaker. In this study, we propose further developments of cardiac THE toward a clinical modality including integration of the vibration source into the patient bed and automated parameter extraction from harmonic shear wave amplitudes, wall motion profiles and synchronized electrocardiographic records. This method has enabled us to evaluate the delay between wall motion and wave amplitude alteration for the measurement of isovolumetric times of elasticity alteration during contraction (τ(C)) and relaxation (τ(R)) in a group of 32 healthy volunteers. On average, the wave amplitudes changed between systole and diastole by a factor of 1.7 ± 0.3, with a τ(C) of 137 ± 61 ms and a τ(R) of 68 ± 73 ms, which agrees with results obtained with the more time-consuming and expensive cardiac magnetic resonance elastography. Furthermore, because of the high sampling rate, elasto-morphometric parameters such as transition times and the area of wave amplitude-cardiac motion cycles can be processed in an automated way for the future clinical detection of myocardial relaxation abnormalities.


internaltional ultrasonics symposium | 2006

P2L-4 Ultrasonic Detection and Quantitative Analysis of Microscopic Bubbles and Particles in Solution: Enhanced by Attenuation Compensation

Sebastian Brand; Robert Klaua; Georg Dietrich; Michael Schultz

In many technical and medical applications microscopic bubbles and particles play an important role. For a non-invasive and quantitative estimation of the particle characteristics acoustic properties along the path of sound propagation are of major concern. When applying clamp-on probes that can be used with a variety of tubes the compensation of the acoustic attenuation is crucial for reliable parameter estimation. In addition, the acoustic properties of the tube material vary as a function of environmental conditions. An ultrasonic probe that enabled an automated and real-time compensation for attenuation properties was under investigation. The set up employs ultrasound in pulsed wave Doppler mode to provide a higher sensitivity for moving objects. Experiments on different tubes (wall-thickness and material) were performed. Glass beads with Gaussian distributed diameters between 300 mum and 400 mum were used as bubble-phantoms. The means and standard deviations of the particle sizes were estimated from the compensated and uncompensated signals. Size estimates were in the range between 100 and 700 mum with a standard deviation of up to 100% when using uncompensated signals. Standard deviations of the estimates applying the compensation algorithm were 50% with mean values of approximately 380 mum. The described method for attenuation compensation was implemented in the bubble counter system BCC200 (GAMPT mbH, Zappendorf, Germany). It enables a precise monitoring of the occurrence of microscopic bubbles and solid particles for the application in open heart surgery and will increase the patient safety. With its performance the BCC200 can also be employed for the development of arterial filters and oxygenators in biomedical applications and for quality control in industrial applications


Ultrasound in Medicine and Biology | 2018

Full-Field-of-View Time-Harmonic Elastography of the Native Kidney

Stephan Rodrigo Marticorena Garcia; Markus Grossmann; Sophia Theresa Lang; Manh Nguyen Trong; Michael Schultz; Jing Guo; Bernd Hamm; Jürgen Braun; Ingolf Sack; Heiko Tzschätzsch

The purpose of this study was to analyze full-field-of-view maps of renal shear wave speed (SWS) measured by time-harmonic elastography (THE) in healthy volunteers in terms of reproducibility, regional variation and physiologic effects. The kidneys of 37 healthy volunteers were investigated by multifrequency THE. The complete renal parenchyma, as well as cortex and medulla, was analyzed. A subgroup was investigated to test reproducibility (n = 3). Significant differences between SWS in cortex, medulla and full parenchyma were observed (2.10 ± 0.17, 1.35 ± 0.11 and 1.71 ± 0.16 m/s, all p values < 0.001) with mean intra-volunteer standard deviations of repeated measurements of 0.04 m/s (1.6%), 0.06 m/s (4.0%) and 0.08 m/s (4.5%), respectively. No effects of kidney anatomy, age, body mass index, blood pressure and heart rate on SWS were observed. THE allows generation of full-field-of-view SWS maps of native kidneys with high reproducibility.


Physics in Medicine and Biology | 2014

In vivo time-harmonic multifrequency elastography of the human liver

Heiko Tzschätzsch; Jing Guo; Kaspar-Josche Streitberger; Enno Gentz; Thomas Fischer; Robert Klaua; Michael Schultz; Jürgen Braun; Ingolf Sack


Archive | 2009

Method and device for a high precision measurement of a characteristic of a fouling and/or scaling deposit inside a fluid vessel or of a characteristic of a portion of the wall inside a fluid vessel by using an ultrsonic transducer

Frank Seida; Christian Flocken; Rainer Pöschmann; Michael Schultz; Robert Klaua; Georg Dietrich


Ultrasound in Medicine and Biology | 2016

Two-Dimensional Time-Harmonic Elastography of the Human Liver and Spleen

Heiko Tzschätzsch; Manh Nguyen Trong; Tobias Scheuermann; Thomas Fischer; Michael Schultz; Jürgen Braun; Ingolf Sack


Archive | 2012

Device and method for detecting deposits

Frank Seida; Christian Flocken; Patric Bierganns; Michael Schultz


Interactive Cardiovascular and Thoracic Surgery | 2010

eComment: Ultrasonic bubble detection: some additional information

Michael Schultz; Robert Klaua; Grit Oblonczek

Collaboration


Dive into the Michael Schultz's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Heiko Tzschätzsch

Humboldt University of Berlin

View shared research outputs
Top Co-Authors

Avatar

Jürgen Braun

Humboldt University of Berlin

View shared research outputs
Top Co-Authors

Avatar

Jing Guo

Humboldt University of Berlin

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge