Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Michael Super is active.

Publication


Featured researches published by Michael Super.


Nature Biotechnology | 2010

Scalable gene synthesis by selective amplification of DNA pools from high-fidelity microchips.

Sriram Kosuri; Nikolai Eroshenko; Emily LeProust; Michael Super; Jeffrey C. Way; Jin Billy Li; George M. Church

Development of cheap, high-throughput, and reliable gene synthesis methods will broadly stimulate progress in biology and biotechnology1. Currently, the reliance on column-synthesized oligonucleotides as a source of DNA limits further cost reductions in gene synthesis2. Oligonucleotides from DNA microchips can reduce costs by at least an order of magnitude3,4,5, yet efforts to scale their use have been largely unsuccessful due to the high error rates and complexity of the oligonucleotide mixtures. Here we use high-fidelity DNA microchips, selective oligonucleotide pool amplification, optimized gene assembly protocols, and enzymatic error correction to develop a highly parallel gene synthesis platform. We tested our platform by assembling 47 genes, including 42 challenging therapeutic antibody sequences, encoding a total of ~35 kilo-basepairs of DNA. These assemblies were performed from a complex background containing 13,000 oligonucleotides encoding ~2.5 megabases of DNA, which is at least 50 times larger than previously published attempts.Development of cheap, high-throughput and reliable gene synthesis methods will broadly stimulate progress in biology and biotechnology. Currently, the reliance on column-synthesized oligonucleotides as a source of DNA limits further cost reductions in gene synthesis. Oligonucleotides from DNA microchips can reduce costs by at least an order of magnitude, yet efforts to scale their use have been largely unsuccessful owing to the high error rates and complexity of the oligonucleotide mixtures. Here we use high-fidelity DNA microchips, selective oligonucleotide pool amplification, optimized gene assembly protocols and enzymatic error correction to develop a method for highly parallel gene synthesis. We tested our approach by assembling 47 genes, including 42 challenging therapeutic antibody sequences, encoding a total of ∼35 kilobase pairs of DNA. These assemblies were performed from a complex background containing 13,000 oligonucleotides encoding ∼2.5 megabases of DNA, which is at least 50 times larger than in previously published attempts.


Nature Biotechnology | 2014

A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling.

Daniel C. Leslie; Anna Waterhouse; Julia Berthet; Thomas M Valentin; Alexander L. Watters; Abhishek Jain; Philseok Kim; Benjamin Hatton; Arthur Nedder; Kathryn Donovan; Elana H. Super; Caitlin Howell; Christopher Johnson; Thy L. Vu; Dana Bolgen; Sami Rifai; Anne Hansen; Michael Aizenberg; Michael Super; Joanna Aizenberg; Donald E. Ingber

Thrombosis and biofouling of extracorporeal circuits and indwelling medical devices cause significant morbidity and mortality worldwide. We apply a bioinspired, omniphobic coating to tubing and catheters and show that it completely repels blood and suppresses biofilm formation. The coating is a covalently tethered, flexible molecular layer of perfluorocarbon, which holds a thin liquid film of medical-grade perfluorocarbon on the surface. This coating prevents fibrin attachment, reduces platelet adhesion and activation, suppresses biofilm formation and is stable under blood flow in vitro. Surface-coated medical-grade tubing and catheters, assembled into arteriovenous shunts and implanted in pigs, remain patent for at least 8 h without anticoagulation. This surface-coating technology could reduce the use of anticoagulants in patients and help to prevent thrombotic occlusion and biofouling of medical devices.


Nature Medicine | 2014

An extracorporeal blood-cleansing device for sepsis therapy

Joo H. Kang; Michael Super; Chong Wing Yung; Ryan M. Cooper; Karel Domansky; Amanda R. Graveline; Julia Berthet; Heather Tobin; Mark J. Cartwright; Alexander L. Watters; Martin Rottman; Anna Waterhouse; Akiko Mammoto; Nazita Gamini; Melissa J. Rodas; Anxhela Kole; Amanda Jiang; Thomas M Valentin; Alexander Diaz; Kazue Takahashi; Donald E. Ingber

Here we describe a blood-cleansing device for sepsis therapy inspired by the spleen, which can continuously remove pathogens and toxins from blood without first identifying the infectious agent. Blood flowing from an infected individual is mixed with magnetic nanobeads coated with an engineered human opsonin—mannose-binding lectin (MBL)—that captures a broad range of pathogens and toxins without activating complement factors or coagulation. Magnets pull the opsonin-bound pathogens and toxins from the blood; the cleansed blood is then returned back to the individual. The biospleen efficiently removes multiple Gram-negative and Gram-positive bacteria, fungi and endotoxins from whole human blood flowing through a single biospleen unit at up to 1.25 liters per h in vitro. In rats infected with Staphylococcus aureus or Escherichia coli, the biospleen cleared >90% of bacteria from blood, reduced pathogen and immune cell infiltration in multiple organs and decreased inflammatory cytokine levels. In a model of endotoxemic shock, the biospleen increased survival rates after a 5-h treatment.


Proceedings of the National Academy of Sciences of the United States of America | 2014

Stationary nanoliter droplet array with a substrate of choice for single adherent/nonadherent cell incubation and analysis

Jonathan Shemesh; Tom Ben Arye; Jonathan Avesar; Joo H. Kang; Amir Fine; Michael Super; Amit Meller; Donald E. Ingber; Shulamit Levenberg

Significance There is a substantial need for single-cell platforms in which each cell is chemically isolated in its own microenvironment and a lack of such platforms that support adherent cells. We present here a method that generates stationary nanoliter droplet arrays on a substrate of choice and supports long-term incubation and interrogation of single cells. We demonstrate the encapsulation of single human dermal fibroblast cells and their substrate attachment, viability, and proliferation, and show they can be retrieved and interfaced to standard cell culturing techniques. We also demonstrate a single-cell metabolic assay and track it over selected groups of indexed traps. The device does not require external equipment or machinery, making it available for point-of-care applications. Microfluidic water-in-oil droplets that serve as separate, chemically isolated compartments can be applied for single-cell analysis; however, to investigate encapsulated cells effectively over prolonged time periods, an array of droplets must remain stationary on a versatile substrate for optimal cell compatibility. We present here a platform of unique geometry and substrate versatility that generates a stationary nanodroplet array by using wells branching off a main microfluidic channel. These droplets are confined by multiple sides of a nanowell and are in direct contact with a biocompatible substrate of choice. The device is operated by a unique and reversed loading procedure that eliminates the need for fine pressure control or external tubing. Fluorocarbon oil isolates the droplets and provides soluble oxygen for the cells. By using this approach, the metabolic activity of single adherent cells was monitored continuously over time, and the concentration of viable pathogens in blood-derived samples was determined directly by measuring the number of colony-formed droplets. The method is simple to operate, requires a few microliters of reagent volume, is portable, is reusable, and allows for cell retrieval. This technology may be particularly useful for multiplexed assays for which prolonged and simultaneous visual inspection of many isolated single adherent or nonadherent cells is required.


Small | 2015

Optimization of Pathogen Capture in Flowing Fluids with Magnetic Nanoparticles.

Joo H. Kang; Eujin Um; Alexander Diaz; Harry Driscoll; Melissa J. Rodas; Karel Domansky; Alexander L. Watters; Michael Super; Howard A. Stone; Donald E. Ingber

Magnetic nanoparticles have been employed to capture pathogens for many biological applications; however, optimal particle sizes have been determined empirically in specific capturing protocols. Here, a theoretical model that simulates capture of bacteria is described and used to calculate bacterial collision frequencies and magnetophoretic properties for a range of particle sizes. The model predicts that particles with a diameter of 460 nm should produce optimal separation of bacteria in buffer flowing at 1 L h(-1) . Validating the predictive power of the model, Staphylococcus aureus is separated from buffer and blood flowing through magnetic capture devices using six different sizes of magnetic particles. Experimental magnetic separation in buffer conditions confirms that particles with a diameter closest to the predicted optimal particle size provide the most effective capture. Modeling the capturing process in plasma and blood by introducing empirical constants (ce ), which integrate the interfering effects of biological components on the binding kinetics of magnetic beads to bacteria, smaller beads with 50 nm diameters are predicted that exhibit maximum magnetic separation of bacteria from blood and experimentally validated this trend. The predictive power of the model suggests its utility for the future design of magnetic separation for diagnostic and therapeutic applications.


Applied Physics Letters | 2016

Application of a Halbach magnetic array for long-range cell and particle separations in biological samples

Joo H. Kang; Harry Driscoll; Michael Super; Donald E. Ingber

Here, we describe a versatile application of a planar Halbach permanent magnet array for an efficient long-range magnetic separation of living cells and microparticles over distances up to 30 mm. A Halbach array was constructed from rectangular bar magnets using 3D-printed holders and compared to a conventional alternating array of identical magnets. We theoretically predicted the superiority of the Halbach array for a long-range magnetic separation and then experimentally validated that the Halbach configuration outperforms the alternating array for isolating magnetic microparticles or microparticle-bound bacterial cells at longer distances. Magnetophoretic velocities (ymag) of magnetic particles (7.9 μm diameter) induced by the Halbach array in a microfluidic device were significantly higher and extended over a larger area than those induced by the alternating magnet array (ymag = 178 versus 0 μm/s at 10 mm, respectively). When applied to 50 ml tubes (∼30 mm diameter), the Halbach array removed >95% of ...


EBioMedicine | 2016

A Broad-Spectrum Infection Diagnostic that Detects Pathogen-Associated Molecular Patterns (PAMPs) in Whole Blood

Mark Cartwright; Martin Rottman; Nathan I. Shapiro; Benjamin T. Seiler; Patrick Lombardo; Nazita Gamini; Julie Tomolonis; Alexander L. Watters; Anna Waterhouse; Daniel C. Leslie; Dana Bolgen; Amanda R. Graveline; Joo H. Kang; Tohid Fatanat Didar; Nikolaos Dimitrakakis; David Cartwright; Michael Super; Donald E. Ingber

Background Blood cultures, and molecular diagnostic tests that directly detect pathogen DNA in blood, fail to detect bloodstream infections in most infected patients. Thus, there is a need for a rapid test that can diagnose the presence of infection to triage patients, guide therapy, and decrease the incidence of sepsis. Methods An Enzyme-Linked Lectin-Sorbent Assay (ELLecSA) that uses magnetic microbeads coated with an engineered version of the human opsonin, Mannose Binding Lectin, containing the Fc immunoglobulin domain linked to its carbohydrate recognition domain (FcMBL) was developed to quantify pathogen-associated molecular patterns (PAMPs) in whole blood. This assay was tested in rats and pigs to explore whether it can detect infections and monitor disease progression, and in prospectively enrolled, emergency room patients with suspected sepsis. These results were also compared with data obtained from non-infected patients with or without traumatic injuries. Results The FcMBL ELLecSA was able to detect PAMPS present on, or released by, 85% of clinical isolates representing 47 of 55 different pathogen species, including the most common causes of sepsis. The PAMP assay rapidly (< 1 h) detected the presence of active infection in animals, even when blood cultures were negative and bacteriocidal antibiotics were administered. In patients with suspected sepsis, the FcMBL ELLecSA detected infection in 55 of 67 patients with high sensitivity (> 81%), specificity (> 89%), and diagnostic accuracy of 0·87. It also distinguished infection from trauma-related inflammation in the same patient cohorts with a higher specificity than the clinical sepsis biomarker, C-reactive Protein. Conclusion The FcMBL ELLecSA-based PAMP assay offers a rapid, simple, sensitive and specific method for diagnosing infections, even when blood cultures are negative and antibiotic therapy has been initiated. It may help to triage patients with suspected systemic infections, and serve as a companion diagnostic to guide administration of emerging dialysis-like sepsis therapies.


PLOS ONE | 2016

Rapid Isolation of Staphylococcus aureus Pathogens from Infected Clinical Samples Using Magnetic Beads Coated with Fc-Mannose Binding Lectin

A. Bicart-See; Martin Rottman; Mark Cartwright; Benjamin T. Seiler; Nazita Gamini; Melissa J. Rodas; M. Penary; G. Giordano; E. Oswald; Michael Super; Donald E. Ingber

Here we describe how Staphylococcus aureus bacteria can be rapidly isolated from clinical samples of articular fluid and synovial tissue using magnetic beads coated with the engineered chimeric human opsonin protein, Fc-mannose-binding lectin (FcMBL). The FcMBL-beads were used to capture and magnetically remove bacteria from purified cultures of 12 S. aureus strains, and from 8 articular fluid samples and 4 synovial tissue samples collected from patients with osteoarthritis or periprosthetic infections previously documented by positive S. aureus cultures. While the capture efficiency was high (85%) with purified S. aureus strains grown in vitro, direct FcMBL-bead capture from the clinical samples was initially disappointing (< 5% efficiency). Further analysis revealed that inhibition of FcMBL binding was due to coating of the bacteria by immunoglobulins and immune cells that masked FcMBL binding sites, and to the high viscosity of these complex biological samples. Importantly, capture of pathogens using the FcMBL-beads was increased to 76% efficiency by pretreating clinical specimens with hypotonic washes, hyaluronidase and a protease cocktail. Using this approach, S. aureus bacteria could be isolated from infected osteoarthritic tissues within 2 hours after sample collection. This FcMBL-enabled magnetic method for rapid capture and concentration of pathogens from clinical samples could be integrated upstream of current processes used in clinical microbiology laboratories to identify pathogens and perform antibiotic sensitivity testing when bacterial culture is not possible or before colonies can be detected.


Advanced Biosystems | 2017

An Engineered Human Fc-Mannose-Binding-Lectin Captures Circulating Tumor Cells

Joo H. Kang; Harry Driscoll; Akiko Mammoto; Alexander L. Watters; Bissrat Melakeberhan; Alexander Diaz; Michael Super; Donald E. Ingber

Tumor cells circulating throughout the body have shown great potential for providing new diagnostic or therapeutic strategies for treating cancer patients. However, isolating circulating tumor cells (CTCs) is still challenging due to the lack of broad spectrum reagents that bind specifically to these cells. This study shows that an engineered human blood opsonin that mimics the innate immune mechanism for opsonizing complex mannan carbohydrates, Fc‐mannose binding lectin (FcMBL), exhibits a broad spectrum of CTC binding activity. Using FcMBL‐coated magnetic beads, this study is able to specifically capture and isolate a broad range of tumor cells spiked into buffer or blood. FcMBL is bound preferentially to human and mouse breast cancer cells relative to normal breast epithelium, and this study demonstrates the capture of seven different types of cancer cells with greater than 90% capture efficiency, whereas two of these same cancer cells bound poorly to anti epithelial cell adhesion molecule antibodies. It is also confirmed that FcMBL‐coated magnetic beads can be used to capture CTCs from the blood of mice bearing metastatic tumors. The FcMBL capture technology may therefore provide a new tool for harvesting a broad range of CTCs with high efficiency as it targets tumor cell specific surface markers that are expressed across diverse cell types and retained throughout the metastatic process.


Molecular Medicine | 2016

Purified and recombinant hemopexin: protease activity and effect on neutrophil chemotaxis.

Tian Lin; Jialin Liu; Feng Huang; Tjitske Sr van Engelen; Sujatha Thundivalappil; Frank E Riley; Michael Super; Alexander L. Watters; Ann Smith; Nathan Brinkman; Donald E. Ingber; H. Shaw Warren

Infusion of the heme-binding protein hemopexin has been proposed as a novel approach to decrease heme-induced inflammation in settings of red blood cell breakdown, but questions have been raised as to possible side effects related to protease activity and inhibition of chemotaxis. We evaluated protease activity and effects on chemotaxis of purified plasma hemopexin obtained from multiple sources as well as a novel recombinant fusion protein Fc-hemopexin. Amidolytic assay was performed to measure the protease activity of several plasma-derived hemopexin and recombinant Fc-hemopexin. Hemopexin was added to the human monocyte culture in the presence of lipopolysaccharides (LPS), and also injected into mice intravenously (i.v.) 30 min before inducing neutrophil migration via intraperitoneal (i.p.) injection of thioglycolate. Control groups received the same amount of albumin. Protease activity varied widely between hemopexins. Recombinant Fc-hemopexin bound heme, inhibited the synergy of heme with LPS on tumor necrosis factor (TNF) production from monocytes, and had minor but detectable protease activity. There was no effect of any hemopexin preparation on chemotaxis, and purified hemopexin did not alter the migration of neutrophils into the peritoneal cavity of mice. Heme and LPS synergistically induced the release of LTB4 from human monocytes, and hemopexin blocked this release, as well as chemotaxis of neutrophils in response to activated monocyte supernatants. These results suggest that hemopexin does not directly affect chemotaxis through protease activity, but may decrease heme-driven chemotaxis and secondary inflammation by attenuating the induction of chemoattractants from monocytes. This property could be beneficial in some settings to control potentially damaging inflammation induced by heme.

Collaboration


Dive into the Michael Super's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alexander L. Watters

Wyss Institute for Biologically Inspired Engineering

View shared research outputs
Top Co-Authors

Avatar

Martin Rottman

French Institute of Health and Medical Research

View shared research outputs
Top Co-Authors

Avatar

Akiko Mammoto

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Joanna Aizenberg

Wisconsin Alumni Research Foundation

View shared research outputs
Researchain Logo
Decentralizing Knowledge