Medical Physics | 2017

Commissioning of the Leksell Gamma Knife® Icon™

Michele Zeverino; Maud Jaccard; David Patin; Nick Ryckx; Maud Marguet; Constantin Tuleasca; Luis Schiappacasse; Jean Bourhis; Marc Levivier; François Bochud; Raphaël Moeckli

Purpose: The Leksell Gamma Knife (LGK) Icon has been recently introduced to provide Gamma Knife technology with frameless stereotactic treatments which use an additional cone‐beam CT (CBCT) imaging system and a motion tracking system (IFMM, Intra‐Fraction Motion Management). The system was commissioned for the treatment unit itself as well as the imaging system. Methods: The LGK Icon was calibrated using an A1SL ionization chamber. EBT3 radiochromic films were employed to independently check the machine calibration, to measure the relative output factors (ROFs) and to collect dose distributions. Coincidence between CBCT isocenter and radiological focus was evaluated by means of EBT3 films. CBCT image quality was investigated in terms of spatial resolution, contrast‐to‐noise ratio (CNR), and uniformity for the two presets available (low dose and high dose). Computed Tomography Dose Index (CTDI) was also measured for both presets. Results: The absolute dose rate of the LGK Icon was 3.86 ± 0.09 Gy/min. This result was confirmed by EBT3 readings. ROF were found to be 0.887 ± 0.035 and 0.797 ± 0.032 for the 8 mm and 4 mm collimators, respectively, which are within 2% of the Monte Carlo‐derived ROF values. Excellent agreement was found between calculated and measured dose distribution with the gamma pass rate >95% of points for the nine dose distributions analyzed with 3%/1 mm criteria. CBCT isocenter was found to be within 0.2 mm with respect to radiological focus. Image quality parameters were found to be well within the manufacturers specifications with the high‐dose preset being superior in terms of CNR and uniformity. CTDI values were 2.41 mGy and 6.32 mGy, i.e. −3.6% and 0.3% different from the nominal values for the low‐dose and high‐dose presets, respectively. Conclusions: The LGK Icon was successfully commissioned for clinical use. The use of the EBT3 to characterize the treatment unit was demonstrated to be feasible. The CBCT imaging system operates well within the manufacturers specifications and provides good geometrical accuracy.


Physica Medica | 2018

Dosimetric evaluation of modern radiation therapy techniques for left breast in deep-inspiration breath-hold

Tuomas Koivumäki; Antonella Fogliata; Michele Zeverino; Eeva Boman; Joanna Sierpowska; Raphaël Moeckli; Véronique Vallet; Luca Cozzi; Janne Heikkilä; Anssi Väänänen; Kristiina Vuolukka; Saara Sillanmäki; Jan Seppälä

PURPOSE The dosimetric differences between four radiation therapy techniques for left sided whole breast irradiation were evaluated side by side in the same patient population. METHODS Radiotherapy treatment plans were retrospectively created with Accuray TomoDirect (TD), Elekta Volumetric Modulated Arc Therapy (E-VMAT), Varian RapidArc (RA) and Field-in-field (FinF) technique for 20 patients, who had received left breast irradiation during deep-inspiration breath-hold. Dose characteristics of planning target volume and organs at risk were compared. RESULTS The E-VMAT, TD and RA treatment plans had higher target coverage (V95%) than FinF plans (97.7-98.3% vs. 96.6%). The low-dose spillage to contralateral breast and lung was smaller with FinF and TD (mean 0.1 and 0.3 Gy) compared to E-VMAT and RA (mean 0.6 and 0.9 Gy). E-VMAT, RA and TD techniques were more effective than FinF in sparing left anterior descending artery (mean 4.0, 4.2 and 4.7 Gy vs. 6.1 Gy, respectively). CONCLUSIONS In whole breast irradiation TD, E-VMAT and RA plans generated in this study achieved higher dose coverage and sparing of organs from the high dose in the vicinity of the PTV. The advantage of calculated FinF plans is the lowest dose on contralateral organs. The choice of the technique used should be weighted by each institution taking into account the dose characteristics of each technique and its fit with patient anatomy bearing in mind the increased workload of using modulated techniques and the increased beam on time.


The Journal of Nuclear Medicine | 2016

Reduction of Respiratory Motion During PET/CT by Pulsatile-Flow Ventilation: A First Clinical Evaluation

John O. Prior; Nicolas Peguret; Anastasia Pomoni; Martin Pappon; Michele Zeverino; Bastien Belmondo; Alban Lovis; Mahmut Ozsahin; Monique Vienne; Jean Bourhis

Respiratory motion negatively affects PET/CT image quality and quantitation. A novel Pulsatile-Flow Ventilation (PFV) system reducing respiratory motion was applied in spontaneously breathing patients to induce sustained apnea during PET/CT. Methods: Four patients (aged 65 ± 14 y) underwent PET/CT for pulmonary nodule staging (mean, 11 ± 7 mm; range, 5–18 mm) at 63 ± 3 min after 18F-FDG injection and then at 47 ± 7 min afterward, during PFV-induced apnea (with imaging lasting ≥8.5 min). Anterior–posterior thoracic amplitude, SUVmax, and SUVpeak (SUVmean in a 1-cm-diameter sphere) were compared. Results: PFV PET/CT reduced thoracic amplitude (80%), increased mean lesion SUVmax (29%) and SUVpeak (11%), decreased lung background SUVpeak (25%), improved lesion detectability, and increased SUVpeak lesion-to-background ratio (54%). On linear regressions, SUVmax and SUVpeak significantly improved (by 35% and 23%, respectively; P ≤ 0.02). Conclusion: PFV-induced apnea reduces thoracic organ motion and increases lesion SUV, detectability, and delineation, thus potentially affecting patient management by improving diagnosis, prognostication, monitoring, and external-radiation therapy planning.


Stereotactic and Functional Neurosurgery | 2016

Jaw Immobilization for Gamma Knife Surgery in Patients with Mandibular Lesions: A Newly, Innovative Approach

Constantin Tuleasca; Martin Broome; Pascal J. Mosimann; Luis Schiappacasse; Michele Zeverino; Antoine Dorenlot; Jérôme Champoudry; Jean Régis; Marc Levivier

Background: The purpose of our report is to describe an innovative system used for mandibular immobilization during Gamma Knife surgery (GKS) procedures. It is based on an approach originally developed in Marseille in extracranial lesions, close to or involving the mandible, which may imply a certain degree of movement during the therapeutic image acquisitions and/or GKS treatment. Methods: The maxillofacial surgeon applied bone titanium self-tapping monocortical screws (4; 2 mm diameter, 10 mm length) between roots of the teeth in the fixed gingiva (upper and lower maxillae) the day before GKS (local anesthesia, 5-10 min time). Two rubber bands were sufficient for the desired tension required to undergo GKS. We further proceeded with application of the Leksell stereotactic G frame and carried out the usual GKS procedure. Results: The mean follow-up period was 2.3 years (range 0.6-3). Three patients have been treated with this approach: 2 cases with extracranial trigeminal schwannomas involving the mandibular branch, with decrease in tumor size on MR follow-up; 1 case with residual paracondylian mandibular arteriovenous malformation following partial embolization, completely obliterated at 7 months (digital subtraction angiography programmed 1 year after treatment). Conclusions: Jaw immobilization appears to be a quick, minimally invasive, safe and accurate adjunctive technique to enhance GKS targeting precision.


Tumori | 2016

Role of functional imaging in treatment plan optimization of stereotactic body radiation therapy for liver cancer.

De Bari B; Jumeau R; Letizia Deantonio; Adib S; Godin S; Michele Zeverino; Raphaël Moeckli; Jean Bourhis; John O. Prior; Mahmut Ozsahin

We report the first known instance of the clinical use of 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) for the optimization of radiotherapy treatment planning and for the follow-up of acute toxicity in a patient undergoing stereotactic body radiation therapy for hepatocellular carcinoma. In our experience, HBS allowed the identification and the sparing of more functioning liver areas, thus potentially reducing the risk of radiation-induced liver toxicity.


Skull Base Surgery | 2018

The Changing Paradigm for the Surgical Treatment of Large Vestibular Schwannomas

Constantin Tuleasca; Alda Rocca; Mercy George; Etienne Pralong; Luis Schiappacasse; Michele Zeverino; Raphael Maire; Mahmoud Messerer; Marc Levivier; Roy Thomas Daniel

Objective Planned subtotal resection followed by Gamma Knife surgery (GKS) in patients with large vestibular schwannoma (VS) has emerged during the past decade, with the aim of a better functional outcome for facial and cochlear function. Methods We prospectively collected patient data, surgical, and dosimetric parameters of a consecutive series of patients treated by this method at Lausanne University Hospital during the past 8 years. Results A consecutive series of 47 patients were treated between July 2010 and January 2018. The mean follow‐up after surgery was 37.5 months (median: 36, range: 0.5‐96). Mean presurgical tumor volume was 11.8 mL (1.47‐34.9). Postoperative status showed normal facial nerve function (House‐Brackmann I) in all patients. In a subgroup of 28 patients, with serviceable hearing before surgery and in which cochlear nerve preservation was attempted at surgery, 26 (92.8%) retained serviceable hearing. Nineteen had good or excellent hearing (Gardner‐Robertson class 1) before surgery, and 16 (84.2%) retained it after surgery. Mean duration between surgery and GKS was 6 months (median: 5, range: 3‐13.9). Mean residual volume as compared with the preoperative one at GKS was 31%. Mean marginal dose was 12 Gy (11‐12). Mean follow‐up after GKS was 34.4 months (6‐84). Conclusion Our data show excellent results in large VS management with a combined approach of microsurgical subtotal resection and GKS on the residual tumor, with regard to the functional outcome and tumor control. Longer term follow‐up is necessary to fully evaluate this approach, especially regarding tumor control.


Physics and Imaging in Radiation Oncology | 2018

A treatment planning comparison of contemporary photon-based radiation techniques for breast cancer

Michele Zeverino; Kristoffer Petersson; Archonteia Kyroudi; Wendy Jeanneret-Sozzi; Jean Bourhis; François Bochud; Raphaël Moeckli

Background and purpose Adjuvant radiation therapy (RT) of the whole breast (WB) is still the standard treatment for early breast cancer. A variety of radiation techniques is currently available according to different delivery strategies. This study aims to provide a comparison of six treatment planning strategies commonly adopted for breast-conserving adjuvant RT and to use the Pareto concept in an attempt to assess the degree of plan optimization. Materials and methods Two groups of six left- and five right-sided cases with different dose prescriptions were involved (22 patients in total). Field-in-Field (FiF), two and four Fields static-IMRT (sIMRT-2f and sIMRT-4f), Volumetric-Modulated-Arc-Therapy (VMAT), Helical Tomotherapy (HT) and Static-Angles Tomotherapy (TomoDirect™ – TD) were planned. Dose volume constraints were taken from the RTOG protocol 1005. Pareto fronts were built for a selected case to evaluate the reliability of the plan optimization process. Results The best target dose coverage was observed for TD able to improve significantly (p < 0.01) the V95% in a range varying from 1.2% to 7.5% compared to other techniques. The V105% was significantly reduced up to 2% for HT (p < 0.05) although FiF and VMAT produced similar values. For the ipsilateral lung, V5Gy, V10Gy and Dmean were significantly lower than all other techniques (p < 0.02) for TD while the lowest value of V20Gy was observed for HT. The maximum dose to contralateral breast was significantly lowest for TD (p < 0.02) and for FiF (p < 0.05). Minor differences were observed for the heart in left-sided patients. Plans for all tested techniques were found to lie on their respective Pareto fronts. Conclusions Overall, TD provided significantly better results in terms of target coverage and dose sparing of ipsilateral lung with respect to all other evaluated techniques. It also significantly minimized dose to contralateral breast together with FiF. Pareto front analysis confirmed the reliability of the optimization for a selected case.


Physica Medica | 2018

Dosimetric analysis of Tomotherapy-based intracranial stereotactic radiosurgery of brain metastasis

S. Agostinelli; S. Garelli; M. Gusinu; Michele Zeverino; F. Cavagnetto; F. Pupillo; A. Bellini; G. Taccini

PURPOSE This paper analyzes Tomotherapy-based intracranial stereotactic radiosurgery (HTSRS) of brain metastasis targeting two end-points: 1) evaluation of dose homogeneity, conformity and gradient scores for single and multiple lesions and 2) assay of dosimetric criticality of completion of HTSRS procedures. METHODS 42 treatment plans of 33 patients (53 brain lesions) treated with HTSRS were analyzed. Dose to healthy brain, homogeneity, conformity and gradient indexes were evaluated for each lesion. Influence of Field Length and multiple lesions cross-talk effect were assessed. Treatment interruption and completion was investigated using radiochromic films in order to examine the delivered dose and its robustness to patient intrafraction movement. RESULTS The average dose homogeneity index was 1.04 ± 0.02 (SD). Average dose conformity and gradient score indexes were 1.4 ± 0.2 and 50 ± 14 respectively. We found a strong correlation of the dose to healthy brain and conformity and gradient indexes with target(s) volume for which analytical functions were obtained. Field Length and cross-talk effect were significantly correlated with poor gradient scores, but were found not to affect dose conformity. CONCLUSIONS Homogeneity and conformity of HTSRS plans achieved excellent scores, while dose falloff and dose to healthy brain were slightly larger when compared with non-coplanar SRS techniques. Care should be given if treating large (>3 cc) or multiple near in-plane lesions in order to reduce dose to healthy brain. Analysis of interrupted treatments suggests splitting HTSRS treatments in two consecutive fractions in order to prevent target miss and overdosage due to patient intrafraction movement.


Cephalalgia | 2018

Gamma Knife radiosurgery for glossopharyngeal neuralgia: A study of 21 patients with long-term follow-up:

Pierre-Yves Borius; Constantin Tuleasca; Xavier Muraciole; Laura Negretti; Luis Schiappacasse; Antoine Dorenlot; Maud Marguet; Michele Zeverino; Anne Donnet; Marc Levivier; Jean Régis

Objective Glossopharyngeal neuralgia (GPN) is a very rare condition, affecting the patient’s quality of life. We report our experience in drug-resistant, idiopathic GPN, treated with Gamma Knife radiosurgery (GKRS), in terms of safety and efficiency, on a very long-term basis. Methods The study was opened, self-controlled, non-comparative and bicentric (Marseille and Lausanne University Hospitals). Patients treated with GKRS between 2003 and 2015 (models C, 4C and Perfexion) were included. A single 4-mm isocentre was positioned in the cisternal portion of the glossopharyngeal nerve, with a targeting based both on magnetic resonance imaging (MRI) and computed tomography (CT). The mean maximal dose delivered was 81.4 ± 6.7 Gy (median = 85 Gy, range = 60–90 Gy at the 100% isodose line). Results Twenty-one patients (11 women, 10 men) benefited from 25 procedures. The mean follow-up period was 5.2 ± 3 years (range = 0.9–12.1 years). Seventeen (81%) were initially pain-free after GKRS. At three months, six months and one year after radiosurgery, the percentage of patients with good outcome (BNI classes I to IIIA) was 87.6%, 100% and 81.8%, respectively. Ten cases (58.8%) from the initial pain-free ones had a recurrence, after a mean period of 13.6 ± 10.4 months (range = 3.1–36.6 months). Only three patients (14.2%) had recurrences (two for each one of them) requiring further surgeries. Three patients underwent a second GKRS procedure; one case needed a third GKRS. The former procedures were performed at 7, 17, 19 and 30 months after the first one, respectively. Furthermore, two patients needed additional interventions. At last follow-up, 17 cases (80.9%) were still pain-free without medication. The actuarial pain relief without new surgery was 83%. A transient complication (paraesthesia of the edge of the tongue) was seen in one case (4.8%). Conclusion GKRS is a valuable, minimally invasive, surgical alternative for idiopathic GPN, with a very high short- and long-term efficacy and without permanent complications. A quality imaging, including T2 CISS/Fiesta MRI and bone CT acquisitions for good visualisation of the nerve and the other bony anatomic landmarks, is essential for targeting accuracy and successful therapy.


Radiotherapy and Oncology | 2016

Apnea-like suppression of respiratory motion: First evaluation in radiotherapy

Nicolas Peguret; Mahmut Ozsahin; Michele Zeverino; Bastien Belmondo; André-Dante Durham; Alban Lovis; Julien Simons; Olivier Long; Frédéric Duclos; John O. Prior; Alban Denys; Catherine Beigelman; Wendy Jeanneret Sozzi; Kathleen Grant; Véronique Gautier-Dechaud; Solange Peters; Monique Vienne; Raphaël Moeckli; Jean Bourhis

Collaboration


Dive into the Michele Zeverino's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Constantin Tuleasca

École Polytechnique Fédérale de Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge