Michelle Burgett
Loma Linda University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Michelle Burgett.
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | 2014
Thomas Halim; Michelle Burgett; Thomas Donaldson; Christina Savisaar; John G. Bowsher; Ian C. Clarke
Particles of bone cement (polymethyl methacrylate), CoCr and Ti6Al4V were compared for their abrasion potential against CoCr substrates. This appears to be the first study utilizing CoCr and Ti6Al4V particulates to abrade CoCr bearings and the first study profiling the morphology of third-body abrasive wear scratches in a hip simulator. The 5 mg debris allotments (median size range 140–300 µm) were added to cups mounted both inverted and anatomically with metal-on-metal (MOM) bearings in a 10-cycle, hip simulator test. Surface abrasion was characterized by roughness indices and scratch profiles. Compared to third-body abrasion with metal debris, polymethyl methacrylate debris had minimal effect on the CoCr surfaces. In all, 10 cycles of abrasion with metal debris demonstrated that roughness indices (Ra, PV) increased approximately 20-fold from the unworn condition. The scratch profiles ranged 20–108 µm wide and 0.5–2.8 µm deep. The scratch aspect ratio (W/PV) averaged 0.03, and this very low ratio indicated that the 140 µm CoCr beads had plastically deformed to create wide but shallow scratches. There was no evidence of transfer of CoCr beads to CoCr bearings. The Ti64 particles produced similar scratch morphology with the same aspect ratio as the CoCr particulates. However, the titanium particulates also showed a unique ability to flatten and adhere to the CoCr, forming smears and islands of contaminating metal on the CoCr bearings. The morphology of scratches and metal transfer produced by these large metal particulates in the simulator appeared identical to those reported on retrieved metal-on-metal bearings.
Clinical Orthopaedics and Related Research | 2014
Ian C. Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G. Bowsher; Michelle Burgett; Thomas Donaldson
BackgroundConcerns have been raised about the sequelae of metal-on-metal (MoM) bearings in total hip arthroplasty (THA). However, retrieval studies, which offer the best insight into the clinically relevant mechanisms of MoM wear, have followed predictable trends to date such as indicting cobalt-chromium (CoCr) metallurgy, cup design, high conformity between the head and cup, “steep cups,” “microseparation,” and “edge wear.”Questions/purposesWe wished to evaluate a set of retrieved 28-mm MoM THA for signs of (1) cup-to-stem impingement; (2) normal wear pattern and concomitant stripe damage on femoral heads that would signify adverse wear mechanics; and (3) well-defined evidence of third-body scratches on bearings that would indicate large abrasive particles had circulated the joint space.MethodsTen 28-mm MOM retrievals were selected on the basis that femoral stems were included. Revision surgeries at 3 to 8 years were for pain, osteolysis, and cup loosening. CoCr stems and the MoM bearings were produced by one vendor and Ti6Al4V stems by a second vendor. All but two cases had been fixed with bone cement. We looked for patterns of normal wear and impingement signs on femoral necks and cup rims. We looked for adverse wear defined as stripe damage that was visually apparent on each bearing. Wear patterns were examined microscopically to determine the nature of abrasions and signs of metal transfer. Graphical models recreated femoral neck and cup designs to precisely correlate impingement sites on femoral necks to cup positions and head stripe patterns.ResultsThe evidence revealed that all CoCr cup liners had impinged on either anterior or posterior facets of femoral necks. Liner impingement at the most proximal neck notch occurred with the head well located and impingement at the distal notch occurred with the head rotated 5 mm out of the cup. The hip gained 20° motion by such a subluxation maneuver with this THA design. All heads had stripe wear, the basal and polar stripes coinciding with cup impingement sites. Analysis of stripe damage revealed 40 to 100-μm wide scratches created by large particles ploughing across bearing surfaces. The association of stripe wear with evidence of neck notching implicated impingement as the root cause, the outcome being the aggressive third-body wear.ConclusionsWe found consistent evidence of impingement, abnormal stripe damage, and evidence of third-body abrasive wear in a small sample of one type of 28-mm MoM design. Impingement models demonstrated that 28-mm heads could lever 20° out of the liners. Although other studies continue to show good success with 28-mm MoM bearings, their use has been discontinued at La Pitie Hospital.Level of EvidenceLevel IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Journal of Bone and Joint Surgery-british Volume | 2013
Michelle Burgett; Thomas Donaldson; Ian C. Clarke
Journal of Bone and Joint Surgery-british Volume | 2013
Michelle Burgett; Thomas Halim; John Vinciguerra; Thomas Donaldson
Journal of Bone and Joint Surgery-british Volume | 2013
Diana Nguyen; Michelle Burgett; Thomas Halim; Thomas Donaldson; Ian C. Clarke
Reconstructive Review | 2013
Wendy W. Wong; Ian C. Clarke; Thomas Donaldson; Michelle Burgett
Journal of Bone and Joint Surgery-british Volume | 2013
Thomas Halim; Michelle Burgett; Ian C. Clarke; Thomas Donaldson
Journal of Bone and Joint Surgery-british Volume | 2013
Diana Nguyen; Michelle Burgett; Ian C. Clarke; Thomas Halim; Thomas Donaldson
Journal of Bone and Joint Surgery-british Volume | 2013
Michelle Burgett; Thomas Donaldson; Yubisela Gonzales
Journal of Bone and Joint Surgery-british Volume | 2013
Edward McPherson; Michelle Burgett; Thomas Halim; Thomas Donaldson; Ian C. Clarke