Featured researches published by Michelle L. Gabriele.


Investigative Ophthalmology & Visual Science | 2011

Optical Coherence Tomography: History, Current Status, and Laboratory Work

Michelle L. Gabriele; Gadi Wollstein; Hiroshi Ishikawa; Larry Kagemann; Juan Xu; Lindsey S. Folio; Joel S. Schuman

Optical coherence tomography (OCT) imaging has become widespread in ophthalmology over the past 15 years, because of its ability to visualize ocular structures at high resolution. This article reviews the history of OCT imaging of the eye, its current status, and the laboratory work that is driving the future of the technology.


British Journal of Ophthalmology | 2009

Retinal nerve fibre layer thickness measurement reproducibility improved with spectral domain optical coherence tomography

Jong S. Kim; Hiroshi Ishikawa; Kyung Rim Sung; Juan A Xu; Gadi Wollstein; Richard A. Bilonick; Michelle L. Gabriele; Larry Kagemann; Jay S. Duker; James G. Fujimoto; Joel S. Schuman

Background/aims: To investigate retinal nerve fibre layer (RNFL) thickness measurement reproducibility using conventional time-domain optical coherence tomography (TD-OCT) and spectral-domain OCT (SD-OCT), and to evaluate two methods defining the optic nerve head (ONH) centring: Centred Each Time (CET) vs Centred Once (CO), in terms of RNFL thickness measurement variability on SD-OCT. Methods: Twenty-seven eyes (14 healthy subjects) had three circumpapillary scans with TD-OCT and three raster scans (three-dimensional or 3D image data) around ONH with SD-OCT. SD-OCT images were analysed in two ways: (1) CET: ONH centre was defined on each image separately and (2) CO: ONH centre was defined on one image and exported to other images after scan registration. After defining the ONH centre, a 3.4 mm diameter virtual circular OCT was resampled on SD-OCT images to mimic the conventional circumpapillary RNFL thickness measurements taken with TD-OCT. Results: CET and CO showed statistically significantly better reproducibility than TD-OCT except for 11:00 with CET. CET and CO methods showed similar reproducibility. Conclusions: SD-OCT 3D cube data generally showed better RNFL measurement reproducibility than TD-OCT. The choice of ONH centring methods did not affect RNFL measurement reproducibility.


Investigative Ophthalmology & Visual Science | 2010

Identification and Assessment of Schlemm's Canal by Spectral-Domain Optical Coherence Tomography

Larry Kagemann; Gadi Wollstein; Hiroshi Ishikawa; Richard A. Bilonick; P. M. Brennen; Lindsey S. Folio; Michelle L. Gabriele; Joel S. Schuman

PURPOSE Measurements of human Schlemms canal (SC) have been limited to histologic sections. The purpose of this study was to demonstrate noninvasive measurements of aqueous outflow (AO) structures in the human eye, examining regional variation in cross-sectional SC areas (on/off collector channel [CC] ostia [SC/CC] and nasal/temporal) in the eyes of living humans. METHODS SC was imaged by spectral-domain optical coherence tomography with a 200-nm bandwidth light source. Both eyes of 21 healthy subjects and one glaucomatous eye of three subjects were imaged nasally and temporally. Contrast and magnification were adjusted to maximize visualization. Cross-sectional SC on and off SC/CC was traced three times by two independent masked observers using ImageJ (ImageJ 1.40g, http://rsb.info.nih.gov/ij/ Wayne Rasband, developer, National Institutes of Health, Bethesda, MD). The mean SC area was recorded. A linear mixed-effects model was used to analyze eye, nasal/temporal laterality, and SC area on or off SC/CC. RESULTS SC area was significantly larger on SC/CCs than off (12,890 vs. 7,391 micorm(2), P < 0.0001) and was significantly larger on the nasal side than on the temporal (10,983 vs. 8,308 micorm(2), P = 0.009). SC areas were significantly smaller in glaucoma patients than in normal subjects, whether pooled (P = 0.0073) or grouped by on (P = 0.0215) or off (P = 0.0114) SC/CC. CONCLUSIONS Aqueous outflow structures, including SC and CCs, can be noninvasively assessed in the human eye. These measurements will be useful in physiological studies of AO and will be clinically useful in the determination of the impact of glaucoma therapies on IOP as well as presurgical planning.


Investigative Ophthalmology & Visual Science | 2008

Optical Coherence Tomography Scan Circle Location and Mean Retinal Nerve Fiber Layer Measurement Variability

Michelle L. Gabriele; Hiroshi Ishikawa; Gadi Wollstein; Richard A. Bilonick; Kelly A. Townsend; Larry Kagemann; Maciej Wojtkowski; Vivek J. Srinivasan; James G. Fujimoto; Jay S. Duker; Joel S. Schuman

PURPOSE To investigate the effect on optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness measurements of varying the standard 3.4-mm-diameter circle location. METHODS The optic nerve head (ONH) region of 17 eyes of 17 healthy subjects was imaged with high-speed, ultrahigh-resolution OCT (hsUHR-OCT; 501 x 180 axial scans covering a 6 x 6-mm area; scan time, 3.84 seconds) for a comprehensive sampling. This method allows for systematic simulation of the variable circle placement effect. RNFL thickness was measured on this three-dimensional dataset by using a custom-designed software program. RNFL thickness was resampled along a 3.4-mm-diameter circle centered on the ONH, then along 3.4-mm circles shifted horizontally (x-shift), vertically (y-shift) and diagonally up to +/-500 microm (at 100-microm intervals). Linear mixed-effects models were used to determine RNFL thickness as a function of the scan circle shift. A model for the distance between the two thickest measurements along the RNFL thickness circular profile (peak distance) was also calculated. RESULTS RNFL thickness tended to decrease with both positive and negative x- and y-shifts. The range of shifts that caused a decrease greater than the variability inherent to the commercial device was greater in both nasal and temporal quadrants than in the superior and inferior ones. The model for peak distance demonstrated that as the scan moves nasally, the RNFL peak distance increases, and as the circle moves temporally, the distance decreases. Vertical shifts had a minimal effect on peak distance. CONCLUSIONS The location of the OCT scan circle affects RNFL thickness measurements. Accurate registration of OCT scans is essential for measurement reproducibility and longitudinal examination (ClinicalTrials.gov number, NCT00286637).


Journal of Biomedical Optics | 2007

Spectral oximetry assessed with high-speed ultra-high- resolution optical coherence tomography

Larry Kagemann; Gadi Wollstein; Maciej Wojtkowski; Hiroshi Ishikawa; Kelly A. Townsend; Michelle L. Gabriele; Vivek J. Srinivasan; James G. Fujimoto; Joel S. Schuman

We use Fourier domain optical coherence tomography (OCT) data to assess retinal blood oxygen saturation. Three-dimensional disk-centered retinal tissue volumes were assessed in 17 normal healthy subjects. After removing DC and low-frequency a-scan components, an OCT fundus image was created by integrating total reflectance into a single reflectance value. Thirty fringe patterns were sampled; 10 each from the edge of an artery, adjacent tissue, and the edge of a vein, respectively. A-scans were recalculated, zeroing the DC term in the power spectrum, and used for analysis. Optical density ratios (ODRs) were calculated as ODR(Art)=ln(Tissue(855)Art(855))ln(Tissue(805)Art(805)) and ODR(Vein)=ln(Tissue(855)Vein(855))ln(Tissue(805)Vein(805)) with Tissue, Art, and Vein representing total a-scan reflectance at the 805- or 855-nm centered bandwidth. Arterial and venous ODRs were compared by the Wilcoxon signed rank test. Arterial ODRs were significantly greater than venous ODRs (1.007+/-2.611 and -1.434+/-4.310, respectively; p=0.0217) (mean+/-standard deviation). A difference between arterial and venous blood saturation was detected. This suggests that retinal oximetry may possibly be added as a metabolic measurement in structural imaging devices.


Investigative Ophthalmology & Visual Science | 2010

Retinal Nerve Fiber Layer Thickness Measurement Comparability between Time Domain Optical Coherence Tomography (OCT) and Spectral Domain OCT

Jong S. Kim; Hiroshi Ishikawa; Michelle L. Gabriele; Gadi Wollstein; Richard A. Bilonick; Larry Kagemann; James G. Fujimoto; Joel S. Schuman

PURPOSE Time domain optical coherence tomography (TD-OCT) has been used commonly in clinical practice, producing a large inventory of circular scan data for retinal nerve fiber layer (RNFL) assessment. Spectral domain (SD)-OCT produces three-dimensional (3-D) data volumes. The purpose of this study was to create a robust technique that makes TD-OCT circular scan RNFL thickness measurements comparable with those from 3-D SD-OCT volumes. METHODS Eleven eyes of 11 healthy subjects and 7 eyes of 7 subjects with glaucoma were enrolled. Each eye was scanned with one centered and eight displaced TD-OCT scanning circles. One 3-D SD-OCT cube scan was obtained at the same visit. The matching location of the TD-OCT scanning circle was automatically detected within the corresponding 3-D SD-OCT scan. Algorithm performance was assessed by estimating the difference between the detected scanning circle location on 3-D SD-OCT volume and the TD-OCT circle location. Global and sectoral RNFL thickness measurement errors between the two devices were also compared. RESULTS The difference (95% confidence interval) in scanning circle center locations between TD- and SD-OCT was 2.3 (1.5-3.2) pixels (69.0 [45.0-96.0] microm on the retina) for healthy eyes and 3.1 (2.0-4.1) pixels (93.0 [60.0-123.0] microm on the retina) for glaucomatous eyes. The absolute RNFL thickness measurement difference was significantly smaller with the matched scanning circle. CONCLUSIONS Scan location matching may bridge the gap in RNFL thickness measurements between TD-OCT circular scan data and 3-D SD-OCT scan data, providing follow-up comparability across the two generations of OCTs.


Optics Express | 2005

Advanced scanning methods with tracking optical coherence tomography.

Daniel X. Hammer; R. Daniel Ferguson; Nicusor Iftimia; Teoman E. Ustun; Gadi Wollstein; Hiroshi Ishikawa; Michelle L. Gabriele; W.D. Dilworth; Larry Kagemann; Joel S. Schuman

An upgraded optical coherence tomography system with integrated retinal tracker (TOCT) was developed. The upgraded system uses improved components to extend the tracking bandwidth, fully integrates the tracking hardware into the optical head of the clinical OCT system, and operates from a single software platform. The system was able to achieve transverse scan registration with sub-pixel accuracy (~10 microm). We demonstrate several advanced scan sequences with the TOCT, including composite scans averaged (co-added) from multiple B-scans taken consecutively and several hours apart, en face images collected by summing the A-scans of circular, line, and raster scans, and three-dimensional (3D) retinal maps of the fovea and optic disc. The new system achieves highly accurate OCT scan registration yielding composite images with significantly improved spatial resolution, increased signal-to-noise ratio, and reduced speckle while maintaining well-defined boundaries and sharp fine structure compared to single scans. Precise re-registration of multiple scans over separate imaging sessions demonstrates TOCT utility for longitudinal studies. En face images and 3D data cubes generated from these data reveal high fidelity image registration with tracking, despite scan durations of more than one minute.


Investigative Ophthalmology & Visual Science | 2010

Reproducibility of Spectral-Domain Optical Coherence Tomography Total Retinal Thickness Measurements in Mice

Michelle L. Gabriele; Hiroshi Ishikawa; Joel S. Schuman; Richard A. Bilonick; J. Kim; Larry Kagemann; Gadi Wollstein

PURPOSE To test the reproducibility of spectral-domain optical coherence tomography (SD-OCT) total retinal thickness (TRT) measurements in mice. METHODS C57Bl/6 mice were anesthetized, and three repeated volumetric images were acquired in both eyes with SD-OCT (250 A-scans × 250 frames × 1024 samplings), centered on the optic nerve head (ONH). The mice were repositioned between scans. TRT was automatically measured within a sampling band of retinal thickness with radii of 55 to 70 pixels, centered on the ONH by using custom segmentation software. The first volumetric image acquired in a given eye was used to register the remaining two SD-OCT images by manually aligning the en face images with respect to rotation and linear translation. Linear mixed-effects models were fitted to global and quadrant thicknesses, taking into account the clustering between eyes, to assess imprecision (measurement reproducibility). RESULTS Twenty-six eyes of 13 adult mice (age 13 weeks) were imaged. The mean global TRT across all eyes was 298.21 μm, with a mouse heterogeneity standard deviation (SD) of 4.88 μm (coefficient of variation [CV] = 0.016), an eye SD of 3.32 μm (CV = 0.011), and a device-related imprecision SD of 2.33 μm (CV = 0.008). The superior quadrant had the thickest mean TRT measurement (310.38 μm) and the highest (worst) imprecision SD (3.13 μm; CV = 0.010), and the inferior quadrant had the thinnest mean TRT (291.55 μm). The quadrant with the lowest (best) imprecision SD was in the nasal one (2.06 μm; CV = 0.007). CONCLUSIONS Good reproducibility was observed for SD-OCT retinal thickness measurements in mice. SD-OCT may be useful for in vivo longitudinal studies in mice.


Progress in Retinal and Eye Research | 2010

Three dimensional optical coherence tomography imaging: Advantages and advances

Michelle L. Gabriele; Gadi Wollstein; Hiroshi Ishikawa; Juan Xu; J. Kim; Larry Kagemann; Lindsey S. Folio; Joel S. Schuman

Three dimensional (3D) ophthalmic imaging using optical coherence tomography (OCT) has revolutionized assessment of the eye, the retina in particular. Recent technological improvements have made the acquisition of 3D-OCT datasets feasible. However, while volumetric data can improve disease diagnosis and follow-up, novel image analysis techniques are now necessary in order to process the dense 3D-OCT dataset. Fundamental software improvements include methods for correcting subject eye motion, segmenting structures or volumes of interest, extracting relevant data post hoc and signal averaging to improve delineation of retinal layers. In addition, innovative methods for image display, such as C-mode sectioning, provide a unique viewing perspective and may improve interpretation of OCT images of pathologic structures. While all of these methods are being developed, most remain in an immature state. This review describes the current status of 3D-OCT scanning and interpretation, and discusses the need for standardization of clinical protocols as well as the potential benefits of 3D-OCT scanning that could come when software methods for fully exploiting these rich datasets are available clinically. The implications of new image analysis approaches include improved reproducibility of measurements garnered from 3D-OCT, which may then help improve disease discrimination and progression detection. In addition, 3D-OCT offers the potential for preoperative surgical planning and intraoperative surgical guidance.


British Journal of Ophthalmology | 2009

Scan quality effect on glaucoma discrimination by glaucoma imaging devices

Kyung Rim Sung; Gadi Wollstein; Joel S. Schuman; Richard A. Bilonick; Hiroshi Ishikawa; Kelly A. Townsend; L. Kagemann; Michelle L. Gabriele

Aim: To evaluate, within ocular imaging scans of acceptable quality as determined by manufacturers’ guidelines, the effects of image quality on glaucoma discrimination capabilities. Methods: One hundred and four healthy and 75 glaucomatous eyes from the Advanced Imaging in Glaucoma Study (AIGS) were imaged with GDx-VCC, HRT II and StratusOCT. Quality score (QS⩾8), pixel standard deviation (SD⩽50) and signal strength (SS⩾5) were used as quality parameter cut-offs, respectively. GDx nerve fibre indicator (NFI) and HRT Moorfields regression analysis (MRA) classifications and OCT mean retinal nerve fibre layer (RNFL) thickness were used as the discriminatory parameters. Logistic regression models were used to model the dichotomous clinical classification (healthy vs glaucoma) as a function of image-quality parameters and discriminatory parameters. Results: Quality parameter covariates were statistically non-significant for GDx and HRT but had an inverse effect on OCT in predicting disease (a higher SS had a lower probability of glaucoma). Age was a significant covariate for GDx and HRT, but not OCT, while ethnicity and interaction between the image quality and the institute where scans were acquired were significant covariates in the OCT models. Conclusion: Scan quality within the range recommended as acceptable by the manufacturer of each imaging device does not affect the glaucoma discriminating ability of GDx or HRT but does affect Stratus OCT glaucoma discrimination.

Collaboration


Dive into the Michelle L. Gabriele's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

L. Kagemann

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar

James G. Fujimoto

Massachusetts Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Larry Kagemann

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge