Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Michiharu Sakakida is active.

Publication


Featured researches published by Michiharu Sakakida.


Sensors and Actuators B-chemical | 1993

Ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane

Michiharu Sakakida; Kenro Nishida; Motoaki Shichiri; Kazuhiko Ishihara; Nobuo Nakabayashi

Abstract A ferrocene-mediated needle-type glucose sensor covered with a newly designed biocompatible membrane of 2-methacryloyloxyethyl phosphorylcholine (MPC) has been developed and its characteristics examined in vitro and in vivo. Application of ferrocene derivatives to the glucose sensor could solve the oxygen-limitation problems, and also compensate the sensor decay due to an insufficient microconvection and diffusion of oxygen resulting from protein fixation on the sensor surface during continuous subcutaneous tissue glucose monitoring. The MPC membrane, a hydrophobic polymer surface covered with a grafted hydrophilic phosphorylcholine chain, has the potential for supressing adsorption of biochemical molecules due to the mobility of the grafted polymer chain. With this glucose sensor covered with an MPC membrane, subcutaneous tissue glucose concentrations can be monitored for up to seven days without any in situ calibrations, followed by 14 days with one-point in situ calibrations. Therefore, we conclude that a ferrocene-mediated needle-type glucose sensor covered with an MPC membrane is stable and reliable, as compared to any other glucose sensors already developed, and can thus be applied for continuous glucose monitoring and for glycaemic control with a wearable artificial endocrine pancreas.


Diabetes Care | 1994

Development of a Miniaturized Glucose Monitoring System by Combining a Needle-Type Glucose Sensor With Microdialysis Sampling Method: Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients

Yasuhiro Hashiguchi; Michiharu Sakakida; Kenro Nishida; Takero Uemura; Kenichiro Kajiwara; Motoaki Shichiri

OBJECTIVE To develop a reliable and practical glucose monitoring system by combining a needle-type glucose sensor with a microdialysis sampling technique for long-term subcutaneous tissue glucose measurements. RESEARCH DESIGN AND METHODS A microdialysis Cuprophan hollowfiber probe (inner diameter, 0.20 mm; length, 15 mm) was perfused with isotonic saline solution (120 μl/h) and glucose concentrations in the dialysate were measured by a needle-type glucose sensor extracorporeally. This system was tested both in vitro and in vivo. Subcutaneous tissue glucose concentrations were then monitored continuously in 5 healthy and 8 diabetic volunteers for 7 to 8 days. A hollow-fiber probe was inserted into the abdominal subcutaneous tissue. RESULTS This monitoring system achieved excellent results in vitro. Subcutaneous tissue glucose concentrations were measured in a wide range from 1.7 to >027.8 mM glucose, with a time delay of 6.9 ±1.2 min associated with a rise in glucose and 8.8 ±1.6 min with a fall in the glucose level (means ± SE). The overall correlation between subcutaneous tissue (Y) and blood (X) glucose concentration was Y = 1.08X ± 0.19 (r = 0.99). The subcutaneous tissue glucose concentration could be monitored precisely for 4 days without any in vivo calibrations and for 7 days by introducing in vivo calibrations. CONCLUSIONS Glycemic excursions could be monitored precisely in the subcutaneous tissue by this microdialysis sampling method with a needle-type glucose sensor in ambulatory diabetic patients.


Endocrine | 2002

Inherited adrenocorticotropin-independent macronodular adrenal hyperplasia with abnormal cortisol secretion by vasopressin and catecholamines : Detection of the aberrant hormone receptors on adrenal gland ()

Nobuhiro Miyamura; Tetsuya Taguchi; Yusuke Murata; Kayo Taketa; Shinsuke Iwashita; Kazuya Matsumoto; Takeshi Nishikawa; Tetsushi Toyonaga; Michiharu Sakakida; Eiichi Araki

ACTH-independent macronodular adrenal hyperplasia (AIMAH) is a rare disorder and an unusual cause of Cushing’s syndrome, of which familial transmission has rarely been reported. In this study, a mother and her son, the former affected with definite AIMAH and the latter with possible AIMAH, are described. Although the mother manifested overt Cushing’s syndrome, her son remained with no stigmata of Cushing’s syndrome except for bilateral adrenal tumor and mild hypertension, and a full suppression of plasma cortisol by low-dose dexamethasone was observed in him. Recently, aberrant expression of adrenal receptors for various ligands has been noted in AIMAH patients. In our cases, provocation tests in vivo suggested that AVP and catecholamines promoted cortisol production through V1a and/or V1b receptors and via β-adrenergic receptor, respectively. Reverse transcriptional-PCR analysis of the operated adrenal tissues of mother revealed the abnormal expression of mRNA of receptors for V1b, V2, and LH/hCG, none of which was observed in a normal control. Inherited AIMAH is very rare, and the son might be at the earliest developmental stage of AIMAH among the cases reported so far. An intervention could be tried to prevent the development of overt Cushing’s syndrome by suppression of the possible endogenous ligands or by blockade of the receptors that may be aberrantly expressed in his adrenal glands.


Medical & Biological Engineering & Computing | 1993

Noninvasive measurement of blood glucose concentrations by analysing fourier transform infra-red absorbance spectra through oral mucosa

Kenichiro Kajiwara; Takero Uemura; Hideki Kishikawa; Kenro Nishida; Yasuhiro Hashiguchi; Masaya Uehara; Michiharu Sakakida; Kenshi Ichinose; Motoaki Shichiri

Whether Fourier transform infra-red spectroscopy with an attenuated total reflection prism could be applied for noninvasive glucose measurement through oral mucosa was evaluated. As a result, the same absorbance peak at 1033 cm−1 as in glucose aqueous solution was found in the absorbance spectra through mucous membrane. However, these glucose specific peaks were interfered with by the baseline drifts owing to prism attachment and the background spectra from body constituents other than glucose. Therefore, to eliminate these interferences, the calibration curve between the second derivatives of the absorbance peak at 1033 cm−1 and those at 2920 cm−1 was calculated (r=0·910). By using this calibration curve, the spectral changes due to prism attachment were first eliminated. Secondly, by obtaining the second derivative of the difference between the postprandial absorbance peak and the fasting sample as a characteristic of an individual, high correlations between the corrected second derivatives of absorbance spectra through the mucous membrane of the lip at 1033 cm−1 and the increases in blood glucose concentrations above fasting levels were observed (r=0·910). In conclusion, it was suggested that Fourier transform infra-red spectroscopy could be useful for noninvasive monitoring of glucose through oral mucosa.


American Journal of Physiology-endocrinology and Metabolism | 2010

An acylic polyisoprenoid derivative, geranylgeranylacetone protects against visceral adiposity and insulin resistance in high-fat-fed mice

Hironori Adachi; Tatsuya Kondo; Rei Ogawa; Kazunari Sasaki; Saori Morino-Koga; Michiharu Sakakida; Junji Kawashima; Hiroyuki Motoshima; Noboru Furukawa; Kaku Tsuruzoe; Nobuhiro Miyamura; Hirofumi Kai; Eiichi Araki

Induction of heat shock protein (HSP)72 improves insulin resistance and obesity in diabetic animal models. Geranylgeranylacetone (GGA), known as an antiulcer drug, induces HSP72 and protects organs against several cellular stresses. This study investigated whether GGA administration would induce HSP72 in liver and render physiological protection against high-fat feeding in mice. A single and 4-wk oral administration of 200 mg/kg GGA was performed in high-fat diet (HFD)-fed mice. Metabolic parameters, cytokines, and gene expressions related to insulin signaling were evaluated. A single administration of GGA induced HSP72 in liver of normal chow-fed and HFD-fed mice. Insulin resistance after HFD was slightly ameliorated. Four weeks of GGA administration also increased HSP72 in liver and significantly improved insulin resistance and glucose homeostasis upon glucose challenge. Activation of c-jun NH₂-terminal kinase (JNK) was attenuated, and insulin signaling was improved in the liver of HFD mice. Visceral adiposity was decreased in GGA-treated mice, accompanied by reduced leptin and increased adiponectin levels. GGA can be a novel therapeutic approach to treat metabolic syndrome as well as type 2 diabetes by improving insulin signaling and reducing adiposity. These beneficial effects of GGA could be mediated through HSP72 induction and JNK inactivation in the liver.


Journal of Artificial Organs | 2004

Comparison between closed-loop portal and peripheral venous insulin delivery systems for an artificial endocrine pancreas.

Taiji Sekigami; Seiya Shimoda; Kenro Nishida; Yasuto Matsuo; Shinji Ichimori; Kenshi Ichinose; Motoaki Shichiri; Michiharu Sakakida; Eiichi Araki

To establish the ideal insulin delivery route for an artificial endocrine pancreas, we examined the effectiveness of closed-loop portal insulin delivery. We investigated the effects of the route of insulin delivery on net hepatic glucose balance (NHGB) in dogs under pancreatic clamp conditions with somatostatin plus basal glucagon and insulin infusions. A constant rate of suprabasal insulin was infused via the portal vein or a peripheral vein, and glucose was infused into the portal vein for 180 min. The mean net hepatic glucose uptake (NHGU) values in the portal insulin infusion group (PI group) were significantly greater than those in the peripheral venous insulin infusion group (VI group); the changes from the baseline values at 180 min were 3.54 ± 0.66 and 2.45 ± 0.82 mg kg−1 min−1 in the PI and VI groups, respectively, P < 0.05. Furthermore, dogs under pancreatic clamp conditions were controlled after a 2-g/kg oral glucose load by applying the closed-loop intraportal (PO) or intravenous (IV) insulin infusion algorithm. There were no significant differences in glycemic control and insulin requirements between these algorithms. However, the maximum peripheral venous and arterial plasma insulin concentrations with the PO algorithm were significantly lower than those with the IV algorithm [305.1 ± 68.9 and 468.1 ± 66.9 pmol/l (peripheral vein) and 305.3 ± 62.9 and 469.6 ± 85.1 pmol/l (artery) with the PO and IV algorithms, respectively, P < 0.05]. On the other hand, the maximum portal plasma insulin concentration with the PO algorithm was significantly higher than that with the IV algorithm (619.9 ± 101.7 and 414.3 ± 79.9 pmol/l with the PO and IV algorithms, respectively, P < 0.05). The mean NHGU values with the PO algorithm were significantly greater than those with the IV algorithm. Our results confirmed that closed-loop portal insulin delivery is feasible with regard to both insulin profiles and hepatic glucose handling in vivo, and indicated that the portal vein is the most suitable insulin delivery route for the artificial endocrine pancreas.


Journal of Artificial Organs | 2003

Strict glycemic control in diabetic dogs with closed-loop intraperitoneal insulin infusion algorithm designed for an artificial endocrine pancreas

Yasuto Matsuo; Seiya Shimoda; Michiharu Sakakida; Kenro Nishida; Taiji Sekigami; Shinji Ichimori; Kenshi Ichinose; Motoaki Shichiri; Eiichi Araki

Abstract The ultimate goal of the development of an artificial endocrine pancreas is to achieve long-term strict glycemic regulation. To establish the physiological insulin delivery route of the artificial endocrine pancreas, intraperitoneal insulin infusion may be important. For this purpose, we tried to develop a closed-loop intraperitoneal insulin infusion algorithm by analyzing the pharmacokinetics of intraperitoneal regular insulin absorption using a mathematical model. The parameters for this algorithm were calculated to simulate the plasma insulin profile after intraperitoneal insulin injection as closely as possible. To evaluate the appropriateness of this algorithm, we tried glycemic control after an oral glucose load of 2 g/kg or a meal load of 80 kcal/kg in diabetic dogs by applying the algorithm. With the use of the subcutaneous insulin lispro infusion algorithm, which we have previously reported, alloxan-induced diabetic dogs exhibited postprandial hyperglycemia and delayed hyperinsulinemia, followed by hypoglycemia after an oral glucose load of 2 g/kg. However, by using the intraperitoneal insulin infusion algorithm, excellent glycemic control (postprandial blood glucose levels of 9.1 ± 0.8 mmol/l at 70 min and 3.8 ± 0.3 mmol/l at 240 min, respectively) could be achieved without any associated delayed hyperinsulinemia or hypoglycemia. Glycemic excursion after a meal load of 80 kcal/kg was also controlled from 3.9 to 10.1 mmol/l. Our results confirm that the intraperitoneal insulin infusion algorithm in vivo is feasible and that this algorithm can be superior to the subcutaneous insulin lispro infusion algorithm in the regulation of blood glucose.


Diabetes | 1987

Role of α2-Adrenergic Receptor in Platelet Activation During Insulin-Induced Hypoglycemia in Normal Subjects

Hideki Kishikawa; Haruo Takeda; Satoshi Kiyota; Michiharu Sakakida; Hideo Fukushima; Kenshi Ichinose; Hiromi Matsuda; Nobuhisa Nakamura; Haruo Uzawa

The effects of α2-adrenergic-receptor blocker mianserin on the responses of blood glucose, plasma β- thromboglobulin (β-TG), and various counterregulatory hormones to insulin-induced hypoglycemia were studied in nine healthy male subjects. The α2-adrenoceptor- blocking action of mianserin was confirmed by its inhibitory effect on platelet activation in vitro. Mianserin was given orally 90 min before insulin injection; the same study without mianserin was performed on another day as the control study. The time courses of blood glucose and serum C-peptide (0, 20, 45, and 180 min after the insulin injection) were identical in both studies, indicating that mianserin has no effect on these parameters. However, a significant increase of p-TG at 45 min after insulin injection was completely suppressed by the administration of mianserin (mean ± SE, 68.5 ± 6.0 vs. 28.8 ± 7.6 ng/ml, n = 6, P < .05). No significant differences were obtained between the two studies in the responses of plasma or serum catecholamines, cortisol, glucagon, growth hormone, thromboxane B2, and 6-ketoprostaglandin F1a. These results suggest that epinephrine is responsible for some, if not all, of the β-TG release from the platelets during insulin-induced hypoglycemia.


Journal of Artificial Organs | 2006

Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas

Shinji Ichimori; Kenro Nishida; Seiya Shimoda; Taiji Sekigami; Yasuto Matsuo; Kenshi Ichinose; Motoaki Shichiri; Michiharu Sakakida; Eiichi Araki

To produce a long-life, stable, miniature glucose sensor for a wearable artificial endocrine pancreas (WAEP), we developed a novel microneedle-type glucose sensor using polyimide, designated the PI sensor (outer diameter, 0.3 mm; length, 16 mm), and investigated its characteristics in vitro and in vivo. In the in vitro study, we tested the sensor in 0.9% NaCl solution with varying glucose concentrations and observed an excellent linear relationship between the sensor output and glucose concentration (range: 0–500 mg/100 ml). In in vivo experiments, the PI sensor was inserted into the abdominal subcutaneous tissue of beagle dogs (n = 5), and interstitial fluid glucose concentrations were monitored after sensor calibration. Simultaneously, blood glucose concentrations were also monitored continuously with another PI sensor placed intravenously. The correlation and time delay between subcutaneous tissue glucose (Y) and blood glucose concentrations (X: 30–350 mg/100 ml) were Y = 1.03X + 7.98 (r = 0.969) and 6.6 ± 1.2 min, respectively. We applied the new WAEP system/PI sensor and an intravenous insulin infusion algorithm developed previously for glycemic control in diabetic dogs. The use of the WAEP system resulted in excellent glycemic control after an oral glucose challenge of 1.5 g/kg (post-challenge blood glucose levels: 176 ± 18 mg/100 ml at 65 min and 93 ± 23 mg/100 ml at 240 min), without any hypoglycemia. Thus, we confirmed that our new PI sensor has excellent sensor characteristics in vitro and in vivo. The new WAEP using this sensor is potentially suitable for clinical application.


Journal of Artificial Organs | 2000

Biocompatibility of MPC: in vivo evaluation for clinical application

Tanja Nowak; Kenro Nishida; Seiya Shimoda; Yumi Konno; Kenshi Ichinose; Michiharu Sakakida; Motoaki Shichiri; Nobuo Nakabayashi; Kazuhiko Ishihara

Biocompatibility is important to assure a mild body reaction to an implanted device and its long-term stability and functionality. In diabetes research, subcutaneously implanted glucose monitoring systems need biocompatible surfaces for long-term application. The biocompatibility of poly(2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate) (MPC), a material similar to the phospholipid layer of a cell membrane, was compared in vivo with the biocompatibility of polyurethane (PU), polyvinyl alcohol (PVA), and cuprophane (CUP). Needle-type glucose sensors and hollow-fiber probes used for microdialysis were coated with these four different biomaterials and implanted subcutaneously in 18 rats and 7 healthy volunteers. At set intervals, the implants and, in the case of the rats, also the surrounding tissue were removed and characterized by light and electron microscopy. MPC-coated sensors and hollow-fiber probes showed smooth and thin deposits in flat layers, whereas the surface deposits on PU- and PVA-coated sensors and those on CUP hollow-fiber probes appeared as rough, irregular, and dense attachments of aggregated cells and protein. This study confirmed results from earlier in vitro tests by showing the biocompatibility and reliability of MPC. Even though the amount of protein and cells attached to the MPC surface was not as low as expected from in vitro experiments, the biocompatibility and long-term stability of the implanted devices were superior to those of PU, PVA, and CUP.

Collaboration


Dive into the Michiharu Sakakida's collaboration.