Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mikio Yashiki is active.

Publication


Featured researches published by Mikio Yashiki.


Forensic Science International | 1995

Detection of amphetamines in urine using head space-solid phase microextraction and chemical ionization selected ion monitoring☆

Mikio Yashiki; Tohru Kojima; Tetsuji Miyazaki; Nobuyuki Nagasawa; Yasumasa Iwasaki; Kenji Hara

An accurate, simple and rapid method for qualitative and quantitative analysis of amphetamine and methamphetamine in urine was developed using head space-solid phase microextraction and gas chromatography-mass spectrometry/chemical ionization selected iron monitoring. A vial containing a urine sample potassium carbonate and pentadeuterated methamphetamine which was used as an internal standard was heated at 80 degrees C for 20 min. The needle of a solid phase microextraction device was passed through the septum, and the extraction fiber in the needle was exposed for 5 min in the head space of the vial. The needle was removed from the vial and inserted into the injection port of gas chromatograph or gas chromatograph/mass spectrometer. The compounds adsorbed on the fiber were detached by exposing the fiber in the injection port, and analyzed. The proposed method was more than 20 times more sensitive than the conventional head space method.


Forensic Science International | 1996

Rapid analysis of amphetamines in blood using head space-solid phase microextraction and selected ion monitoring

Akira Namera; Mikio Yashiki; Nobuyuki Nagasawa; Yasumasa Iwasaki; Tohru Kojima

A simple and rapid method for analysis of methamphetamine (MA) and amphetamine (AP) in blood was developed using head space-solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry/electron impact ionization-selected ion monitoring (GC-MS/EI-SIM). A vial containing a blood sample, sodium hydroxide, and pentadeuterated methamphetamine as an internal standard, was heated at 80 degrees C for 20 min. The extraction fiber of the SPME was exposed for 5 min in the head space of the vial. First, heptafluorobutyric anhydride solution was injected into the injection port of the GC-MS to make heptafluorobutyramide (HFB) derivatives of amphetamines, and compounds absorbed on the fiber were detached by exposing the fiber in the injection port. Straight calibration curves of MA and AP were obtained from 0.01 to 2 micrograms/g in blood, respectively. No interfering substances were found, and the time for analysis was 30 min for one sample.


Journal of Chromatography B | 2002

Direct extract derivatization for determination of amino acids in human urine by gas chromatography and mass spectrometry.

Akira Namera; Mikio Yashiki; Manami Nishida; Tohru Kojima

The purpose of this study was to develop a simple and accurate analytical method to determine amino acids in urine samples. The developed method involves the employment of an extract derivatization technique together with gas chromatography-mass spectrometry (GC-MS). Urine samples (300 microl) and an internal standard (10 microl) were placed in a screw tube. Ethylchloroformate (50 microl), methanol-pyridine (500 microl, 4:1, v/v) and chloroform (1 ml) were added to the tube. The organic layer (1 microl) was injected to a GC-MS system. In this proposed method, the amino acids in urine were derivatized during an extraction, and the analytes were then injected to GC-MS without an evaporation of the organic solvent extracted. Sample preparation was only required for ca. 5 min. The 15 amino acids (alanine, aspartic acid, cysteine, glutamic acid, glycine, histidine, isoleucine, leucine, lysine, methionine, phenylalanine, proline, tyrosine, tryptophan, valine) quantitatively determined in this proposed method. However, threonine, serine, asparagine, glutamine, arginine were not derivatized using any tested derivatizing reagent. The calibration curves showed linearity in the range of 1.0-300 microg/ml for each amino acid in urine. The correlation coefficients of the calibration curves of the tested amino acids were from 0.966 to 0.998. The limit of detection in urine was 0.5 microg/ml except for aspartic acid. This proposed method demonstrated substantial accuracy for detection of normal levels. This proposed method was limited for the determination of 15 amino acids in urine. However, the sample preparation was simple and rapid, and this method is suitable for a routine analysis of amino acids in urine.


Journal of Chromatography B: Biomedical Sciences and Applications | 1998

Simple analysis of local anaesthetics in human blood using headspace solid-phase microextraction and gas chromatography–mass spectrometry–electron impact ionization selected ion monitoring

Tomohiko Watanabe; Akira Namera; Mikio Yashiki; Yasumasa Iwasaki; Tohru Kojima

A simple method for analysis of five local anaesthetics in blood was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry-electron impact ionization selected ion monitoring (GC-MS-EI-SIM). Deuterated lidocaine (d10-lidocaine) was synthesized and used as a desirable internal standard (I.S.). A vial containing a blood sample, 5 M sodium hydroxide and d10-lidocaine (I.S.) was heated at 120 degrees C. The extraction fiber of the SPME system was exposed for 45 min in the headspace of the vial. The compounds adsorbed on the fiber were desorbed by exposing the fiber in the injection port of a GC-MS system. The calibration curves showed linearity in the range of 0.1-20 microg/g for lidocaine and mepivacaine, 0.5-20 microg/g for bupivacaine and 1-20 microg/g for prilocaine in blood. No interfering substances were found, and the time for analysis was 65 min for one sample. In addition, this proposed method was applied to a medico-legal case where the cause of death was suspected to be acute local anaesthetics poisoning. Mepivacaine was detected in the left and right heart blood samples of the victim at concentrations of 18.6 and 15.8 microg/g, respectively.


Forensic Science International | 2000

Simple and simultaneous analysis of fenfluramine, amphetamine and methamphetamine in whole blood by gas chromatography-mass spectrometry after headspace-solid phase microextraction and derivatization.

Akira Namera; Mikio Yashiki; Junting Liu; Kazuo Okajima; Kenji Hara; Tohru Imamura; Tohru Kojima

A simple and sensitive method for the simultaneous analysis of fenfluramine, amphetamine and methamphetamine in whole blood was developed using a headspace-solid phase microextraction (SPME) and derivatization. A 0.5 g whole blood sample, 5 microl d(5)-methamphetamine (50 micrig/ml) as an internal standard, and 0.5 ml sodium hydroxide (1 M) were placed into a 12 ml vial, and sealed rapidly with a silicone septum and an aluminum cap. Immediately after the vial was heated to 70 degrees C in an aluminium block heater, the needle of the SPME device was inserted through the septum of the vial, and the extraction fiber was exposed in the headspace for 15 min. First, heptafluorobutyric anhydride was injected into the injection port of the GC-MS, and the compounds extracted by the fiber were then desorbed and derivatized simultaneously by exposing the fiber in the injection port. The calibration curves, using an internal standard method, demonstrated good linearity throughout the concentration range from 0.01 to 1.0 microg/g. The detection limits of this method were 5.0 ng/g for fenfluramine and methamphetamine, and 10 ng/g for amphetamine. No interferences were found, and the time for analysis was about 30 min for one sample. This method was applied to a suicide case in which the victim ingested fenfluramine. Fenfluramine was detected in the blood sample collected from the victim at the concentration of 7.7 microg/g.


Journal of Chromatography A | 2008

Extraction of amphetamines and methylenedioxyamphetamines from urine using a monolithic silica disk-packed spin column and high-performance liquid chromatography-diode array detection.

Akira Namera; Akihiro Nakamoto; Manami Nishida; Takeshi Saito; Izumi Kishiyama; Shota Miyazaki; Midori Yahata; Mikio Yashiki; Masataka Nagao

To overcome the limitations of solid-phase extraction, we developed a device comprising a spin column packed with octadecyl silane-bonded monolithic silica for extracting amphetamines and methylenedioxyamphetamines from urine. Urine (0.5mL), buffer (0.4mL), and methoxyphenamine (internal standard) were directly put into the preactivated column. The column was centrifuged (3000rpm, 5min) for sample loading and washed. The adsorbed analytes were eluted and analyzed by high-performance liquid chromatography, without evaporation. The results were as follows: linear curves (drug concentrations of 0.2-20microg/mL); correlation coefficients >0.99; detection limit, 0.1microg/mL. The proposed method is not only useful for drugs from biological materials but also highly reproducible for the analysis of these drugs in urine.


Forensic Science International | 1984

A fatal methamphetamine poisoning associated with hyperpyrexia

Tohru Kojima; I. Une; Mikio Yashiki; J. Noda; K. Sakai; K. Yamamoto

After self-administration of 0.05 g of methamphetamine hydrochloride intravenously on three occasions at intervals of 3 h, a 25-year-old female methamphetamine abuser ingested approximately 1.5 g of methamphetamine hydrochloride, and was found dead 3-4 h later. Complete rigor mortis was observed 1-2 h after death and the rectal temperature was 38.4 degrees C 3-4 h after death. Distribution of methamphetamine and amphetamine in the body was analyzed by chemical ionization mass fragmentography. Amphetamine/methamphetamine concentrations (mumol/100 g) were 0.26/28.8 in blood, 0.64/68.2 in brain, 0.96/117.1 in liver, 0.53/50.6 in kidney, and 1.49/1045 in stomach contents. Total amount of methamphetamine hydrochloride in stomach contents was 11.6 mg. Amphetamine in tissues was a metabolite of methamphetamine, and amphetamine in stomach contents resulted from excretion into saliva and gastric mucous excretion. With rectal temperature at death estimated at more than 41 degrees C, it would seem that hyperpyrexia played an important role in causing death from methamphetamine poisoning.


Forensic Science International | 2002

Quantitative analysis of tropane alkaloids in biological materials by gas chromatography–mass spectrometry

Akira Namera; Mikio Yashiki; Yasuo Hirose; Seiichi Yamaji; Tadato Tani; Tohru Kojima

A simple and rapid method for quantitation of tropane alkaloids in biological materials has been developed using an Extrelut column with gas chromatography-mass spectrometry (GC-MS). Biological materials (serum and urine) were mixed with a borate buffer and then applied to an Extrelut column. The adsorbed tropane alkaloids were eluted with dichloromethane before a GC-MS analysis. Atropine-d(3) was used as an internal standard. The extracted tropane alkaloids were converted to trimethylsilyl derivatives prior to GC analysis, to improve the instability of tropane alkaloids from heating and the property of them for a GC column. The recoveries of the compounds, which had been spiked to biological materials, were more than 80%. The GC separation of the derivatives from endogenous impurities was generally satisfactory with the use of a semi-polar capillary column. Tropane alkaloids showed excellent linearity in the range of 10-5000 ng/ml and the limit of detection was 5.0 ng/ml for biological materials. The present method is simple and more rapid than those previously reported, and was applied to a poisoning case. It is useful for the routine analysis of tropane alkaloids in cases of suspected tropane alkaloids poisoning.


Forensic Science International | 2001

Highly sensitive analysis of methamphetamine and amphetamine in human whole blood using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

Kazuo Okajima; Akira Namera; Mikio Yashiki; Ichiro Tsukue; Tohru Kojima

A simple and highly sensitive method for analysis of derivatized methamphetamine (MA) and amphetamine (AM) in whole blood was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry electron impact ionization selected ion monitoring (GC-MS-EI-SIM). A whole blood sample, deuterated-MA (d(5)-MA), as an internal standard (IS), tri-n-propylamine and pentafluorobenzyl bromide were placed in a vial. The vial was heated and stirred at 90 degrees C for 30min. Then the extraction fiber of the SPME was exposed at 90 degrees C for 30min in the headspace of the vial while being stirred. The derivatives adsorbed on the fiber were desorbed by exposing the fiber in the injection port of a GC-MS. The calibration curves showed linearity in the range of 0.5-1000ng/g for both MA and AM. The time for analysis was about 80min per sample. In addition, this proposed method was applied to two autopsy cases where MA ingestion was suspected. In one case, MA and AM concentrations in the mixed left and right heart blood were 165 and 36.9ng/g, respectively. In the other case, MA and AM concentrations were 1.79 and 0.119 microg/g in the left heart blood, and 1.27 and 0.074 microg/g in the right heart blood, respectively.


American Journal of Forensic Medicine and Pathology | 1993

Site dependence of methamphetamine concentrations in blood samples collected from cadavers of people who had been methamphetamine abusers

Tetsuji Miyazaki; Tohru Kojima; Mikio Yashiki; Hironori Wakamoto; Yasumasa Iwasaki; Takanori Taniguchi

Various blood samples were collected from heart cavities and blood vessels in eight autopsy cases of people who had been methamphetamine abusers. Methamphetamine and its metabolite, amphetamine, were determined by gas chromatography-mass spectrometry-selected ion monitoring. In four cases where left and right heart blood samples were collected, methamphetamine concentrations in the left heart blood samples were 1.9–2.6 times higher than those in the right heart blood samples. In three cases where pulmonary vein blood samples were collected, methamphetamine concentrations in the pulmonary vein blood samples were higher than those in other blood samples sites. To interpret the blood methamphetamine concentrations, site dependence should be taken into consideration.

Collaboration


Dive into the Mikio Yashiki's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge