Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mikko Juuti is active.

Publication


Featured researches published by Mikko Juuti.


European Journal of Pharmaceutics and Biopharmaceutics | 2014

Visualization and understanding of the granulation liquid mixing and distribution during continuous twin screw granulation using NIR chemical imaging.

Jurgen Vercruysse; Maunu Toiviainen; Margot Fonteyne; Niko Helkimo; Jarkko Ketolainen; Mikko Juuti; Urbain Alfons C. Delaet; Ivo Van Assche; Jean Paul Remon; Chris Vervaet; Thomas De Beer

Over the last decade, there has been increased interest in the application of twin screw granulation as a continuous wet granulation technique for pharmaceutical drug formulations. However, the mixing of granulation liquid and powder material during the short residence time inside the screw chamber and the atypical particle size distribution (PSD) of granules produced by twin screw granulation is not yet fully understood. Therefore, this study aims at visualizing the granulation liquid mixing and distribution during continuous twin screw granulation using NIR chemical imaging. In first instance, the residence time of material inside the barrel was investigated as function of screw speed and moisture content followed by the visualization of the granulation liquid distribution as function of different formulation and process parameters (liquid feed rate, liquid addition method, screw configuration, moisture content and barrel filling degree). The link between moisture uniformity and granule size distributions was also studied. For residence time analysis, increased screw speed and lower moisture content resulted to a shorter mean residence time and narrower residence time distribution. Besides, the distribution of granulation liquid was more homogenous at higher moisture content and with more kneading zones on the granulator screws. After optimization of the screw configuration, a two-level full factorial experimental design was performed to evaluate the influence of moisture content, screw speed and powder feed rate on the mixing efficiency of the powder and liquid phase. From these results, it was concluded that only increasing the moisture content significantly improved the granulation liquid distribution. This study demonstrates that NIR chemical imaging is a fast and adequate measurement tool for allowing process visualization and hence for providing better process understanding of a continuous twin screw granulation system.


European Journal of Pharmaceutical Sciences | 2013

In-line monitoring of the drug content of powder mixtures and tablets by near-infrared spectroscopy during the continuous direct compression tableting process

Kristiina Järvinen; Wolfgang Hoehe; Maiju Järvinen; Sami Poutiainen; Mikko Juuti; Sven Borchert

Continuous manufacturing methods offer economic and quality advantages when compared with batch manufacturing methods. In continuous manufacturing, one requires real time assurance of quality of product via the implementation of PAT tools. This study focuses on an in-line near-infrared (NIR) spectroscopic method for determining the drug content of powder mixtures and tablets during a continuous tableting process. Tablets consisting of acetaminophen (20-30%), lactose (69.07-78.93%) and magnesium stearate (0.93-1.07%) were prepared in a continuous direct compression line that consisted of two loss-in-weight feeders, one for acetaminophen and one for premixed lactose and magnesium stearate, and a continuous mixer followed by a rotary tablet press. NIR spectroscopy was applied to the continuous mixer and tablet press to perform a 100% product check at full tableting speed. The UV-spectrophotometric method was used as an off-line reference method to determine the acetaminophen content in the samples. The powder mixture and tablet samples were taken during the process for the calibration of continuous mixer and tablet press, respectively. For the continuous mixer, model creation with the PLS method yielded R-Square and RMSEC (root mean square error of calibration) values of 0.975% and 0.56%, respectively. For the tablet press, the corresponding R-Square and RMSEC values were 0.943% and 0.75%, respectively. A test run demonstrated good predictability in the estimation of the API content in the powder mixtures and tablets during the continuous tableting process. For the continuous mixer and tablet press, the RMSEP (root mean square error of prediction) values were 0.96% and 1.37%, respectively. This study demonstrates that an NIR instrument capable of fast spectra acquisition can be a valuable tool for the in-line monitoring of the continuous mixing and tableting processes.


Measurement Science and Technology | 2009

Optical and terahertz measurement techniques for flat-faced pharmaceutical tablets: a case study of gloss, surface roughness and bulk properties of starch acetate tablets

Mikko Juuti; H. Tuononen; Tuukka Prykäri; V. Kontturi; M. Kuosmanen; Erkki Alarousu; J. Ketolainen; R. Myllylä; Kai-Erik Peiponen

Surface and bulk properties of flat-faced starch acetate tablets were studied. For surface quality inspection optical coherence tomography and recently developed diffractive glossmeter were utilized. Both these optical devices together provide local information on surface roughness and gloss of a tablet over a measured area. The concepts of mean topography and mean gloss profile for surface quality of a tablet are introduced. It was observed that the surface quality of the tablet varies, and compression at high pressure may not guarantee a good surface quality of the tablet. Using novel statistical parameters for gloss and relevant surface roughness parameter, it is possible to get more comprehensive quantitative data on the surface condition of a tablet. THz spectrometer was utilized for detection of THz pulse delay in transmission measurement mode from the tablets. The delay time and thickness ratio of the tablet are consistent with the porosity of the tablet as a function of compression pressure. We suggest that the multimeasurement scheme using three different devices helps tablet makers to better assess bulk and surface quality of their products.


Analytical Chemistry | 2013

In-Line Multipoint Near-Infrared Spectroscopy for Moisture Content Quantification during Freeze-Drying

Ari Kauppinen; Maunu Toiviainen; Ossi Korhonen; Jaakko Aaltonen; Kristiina Järvinen; Janne Paaso; Mikko Juuti; Jarkko Ketolainen

During the past decade, near-infrared (NIR) spectroscopy has been applied for in-line moisture content quantification during a freeze-drying process. However, NIR has been used as a single-vial technique and thus is not representative of the entire batch. This has been considered as one of the main barriers for NIR spectroscopy becoming widely used in process analytical technology (PAT) for freeze-drying. Clearly it would be essential to monitor samples that reliably represent the whole batch. The present study evaluated multipoint NIR spectroscopy for in-line moisture content quantification during a freeze-drying process. Aqueous sucrose solutions were used as model formulations. NIR data was calibrated to predict the moisture content using partial least-squares (PLS) regression with Karl Fischer titration being used as a reference method. PLS calibrations resulted in root-mean-square error of prediction (RMSEP) values lower than 0.13%. Three noncontact, diffuse reflectance NIR probe heads were positioned on the freeze-dryer shelf to measure the moisture content in a noninvasive manner, through the side of the glass vials. The results showed that the detection of unequal sublimation rates within a freeze-dryer shelf was possible with the multipoint NIR system in use. Furthermore, in-line moisture content quantification was reliable especially toward the end of the process. These findings indicate that the use of multipoint NIR spectroscopy can achieve representative quantification of moisture content and hence a drying end point determination to a desired residual moisture level.


Drug Development and Industrial Pharmacy | 2013

Continuous direct tablet compression: effects of impeller rotation rate, total feed rate and drug content on the tablet properties and drug release

Maiju Järvinen; Janne Paaso; Marko Paavola; Kauko Leiviskä; Mikko Juuti; Fernando J. Muzzio; Kristiina Järvinen

Context: Continuous processing is becoming popular in the pharmaceutical industry for its cost and quality advantages. Objective: This study evaluated the mechanical properties, uniformity of dosage units and drug release from the tablets prepared by continuous direct compression process. Materials and methods: The tablet formulations consisted of acetaminophen (3–30% (w/w)) pre-blended with 0.25% (w/w) colloidal silicon dioxide, microcrystalline cellulose (69–96% (w/w)) and magnesium stearate (1% (w/w)). The continuous tableting line consisted of three loss-in-weight feeders and a convective continuous mixer and a rotary tablet press. The process continued for 8 min and steady state was reached within 5 min. The effects of acetaminophen content, impeller rotation rate (39–254 rpm) and total feed rate (15 and 20 kg/h) on tablet properties were examined. Results and discussion: All the tablets complied with the friability requirements of European Pharmacopoeia and rapidly released acetaminophen. However, the relative standard deviation of acetaminophen content (10% (w/w)) increased with an increase in impeller rotation rate at a constant total feed rate (20 kg/h). A compression force of 12 kN tended to result in greater tablet hardness and subsequently a slower initial acetaminophen release from tablets when compared with those made with the compression force of about 8 kN. Conclusions: In conclusion, tablets could be successfully prepared by a continuous direct compression process and process conditions affected to some extent tablet properties.


European Journal of Pharmaceutical Sciences | 2015

Conceptual framework for model-based analysis of residence time distribution in twin-screw granulation

Ashish Kumar; Jurgen Vercruysse; Valérie Vanhoorne; Maunu Toiviainen; Pierre-Emmanuel Panouillot; Mikko Juuti; Chris Vervaet; Jean Paul Remon; Krist V. Gernaey; Thomas De Beer; Ingmar Nopens

Twin-screw granulation is a promising continuous alternative for traditional batchwise wet granulation processes. The twin-screw granulator (TSG) screws consist of transport and kneading element modules. Therefore, the granulation to a large extent is governed by the residence time distribution within each module where different granulation rate processes dominate over others. Currently, experimental data is used to determine the residence time distributions. In this study, a conceptual model based on classical chemical engineering methods is proposed to better understand and simulate the residence time distribution in a TSG. The experimental data were compared with the proposed most suitable conceptual model to estimate the parameters of the model and to analyse and predict the effects of changes in number of kneading discs and their stagger angle, screw speed and powder feed rate on residence time. The study established that the kneading block in the screw configuration acts as a plug-flow zone inside the granulator. Furthermore, it was found that a balance between the throughput force and conveying rate is required to obtain a good axial mixing inside the twin-screw granulator. Although the granulation behaviour is different for other excipients, the experimental data collection and modelling methods applied in this study are generic and can be adapted to other excipients.


Analytical Chemistry | 2013

Microscale Freeze-Drying with Raman Spectroscopy as a Tool for Process Development

Ari Kauppinen; Maunu Toiviainen; Jaakko Aaltonen; Ossi Korhonen; Kristiina Järvinen; Mikko Juuti; Riikka Pellinen; Jarkko Ketolainen

Until recently, the freeze-drying process and formulation development have suffered from a lack of microscale analytical tools. Using such an analytical tool should decrease the required sample volume and also shorten the duration of the experiment compared to a laboratory scale setup. This study evaluated the applicability of Raman spectroscopy for in-line monitoring of a microscale freeze-drying process. The effect of cooling rate and annealing step on the solid-state formation of mannitol was studied. Raman spectra were subjected to principal component analysis to gain a qualitative understanding of the process behavior. In addition, mannitol solid-state form ratios were semiquantitatively analyzed during the process with a classical least-squares regression. A standard cooling rate of 1 °C/min with or without an annealing step at -10 °C resulted in a mixture of α, β, δ, and amorphous forms of mannitol. However, a standard cooling rate induced the formation of mannitol hemihydrate, and a secondary drying temperature of +60 °C was required to transform the hemihydrate form to the more stable anhydrous polymorphs. A fast cooling rate of 10 °C/min mainly produced δ and amorphous forms of mannitol, regardless of annealing. These results are consistent with those from larger scale equipment. In-line monitoring the solid-state form of a sample is feasible with a Raman spectrometer coupled microscale freeze-drying stage. These results demonstrate the utility of a rapid, in-line, low sample volume method for the semiquantitative analysis of the process and formulation development of freeze-dried products on the microscale.


Applied Physics Letters | 2006

Statistical parameters for gloss evaluation

Kai-Erik Peiponen; Mikko Juuti

The measurement of minute changes in local gloss has not been presented in international standards due to a lack of suitable glossmeters. The development of a diffractive-element-based glossmeter (DOG) made it possible to detect local variation of gloss from planar and complex-shaped surfaces. Hence, a demand for proper statistical gloss parameters for classifying surface quality by gloss, similar to the standardized surface roughness classification, has become necessary. In this letter, we define statistical gloss parameters and utilize them as an example in the characterization of gloss from metal surface roughness standards by the DOG.


Journal of Pharmaceutical and Biomedical Analysis | 2014

Validation of a multipoint near-infrared spectroscopy method for in-line moisture content analysis during freeze-drying

Ari Kauppinen; Maunu Toiviainen; Marko Lehtonen; Kristiina Järvinen; Janne Paaso; Mikko Juuti; Jarkko Ketolainen

This study assessed the validity of a multipoint near-infrared (NIR) spectroscopy method for in-line moisture content analysis during a freeze-drying process. It is known that the moisture content affects the stability of a freeze-dried product and hence it is a major critical quality attribute. Therefore assessment of the validity of an analytical method for moisture content determination is vital to ensure the quality of the final product. An aqueous sucrose solution was used as the model formulation of the study. The NIR spectra were calibrated to the moisture content using partial least squares (PLS) regression with coulometric Karl Fischer (KF) titration as the reference method. Different spectral preprocessing methods were compared for the PLS models. A calibration model transfer protocol was established to enable the use of the method in the multipoint mode. The accuracy profile was used as a decision tool to determine the validity of the method. The final PLS model, in which NIR spectra were preprocessed with standard normal variate transformation (SNV), resulted in low root mean square error of prediction value of 0.04%-m/v, i.e. evidence of sufficient overall accuracy of the model. The validation results revealed that the accuracy of the model was acceptable within the moisture content range 0.16-0.70%-m/v that is specific for the latter stages of the freeze-drying process. In addition, the results demonstrated the methods reliable in-process performance and robustness. Thus, the multipoint NIR spectroscopy method was proved capable of providing in-line evaluation of moisture content and it is readily available for use in laboratory scale freeze-drying research and development.


European Journal of Pharmaceutical Sciences | 2016

Linking granulation performance with residence time and granulation liquid distributions in twin-screw granulation: An experimental investigation

Ashish Kumar; Maija Alakarjula; Valérie Vanhoorne; Maunu Toiviainen; Fien De Leersnyder; Jurgen Vercruysse; Mikko Juuti; Jarkko Ketolainen; Chris Vervaet; Jean Paul Remon; Krist V. Gernaey; Thomas De Beer; Ingmar Nopens

Twin-screw granulation is a promising wet granulation technique for the continuous manufacturing of pharmaceutical solid dosage forms. A twin screw granulator displays a short residence time. Thus, the solid-liquid mixing must be achieved quickly by appropriate arrangement of transport and kneading elements in the granulator screw allowing the production of granules with a size distribution appropriate for tableting. The distribution of residence time and granulation liquid is governed by the field conditions (such as location and length of mixing zones) in the twin-screw granulator, thus contain interesting information on granulation time, mixing and resulting sub-processes such as wetting, aggregation and breakage. In this study, the impact of process (feed rate, screw speed and liquid-to-solid ratio) and equipment parameters (number of kneading discs and stagger angle) on the residence time (distribution), the granulation liquid-powder mixing and the resulting granule size distributions during twin-screw granulation were investigated. Residence time and axial mixing data was extracted from tracer maps and the solid-liquid mixing was quantified from moisture maps, obtained by monitoring the granules at the granulator outlet using near infra-red chemical imaging (NIR-CI). The granule size distribution was measured using the sieving method. An increasing screw speed dominantly reduced the mean residence time. Interaction of material throughput with the screw speed and with the number of kneading discs led to most variation in the studied responses including residence time and mixing capacity. At a high screw speed, granulation yield improved due to high axial mixing. However, increasing material throughput quickly lowers the yield due to insufficient mixing of liquid and powder. Moreover, increasing liquid-to-solid ratio resulted in more oversized granules, and the fraction of oversized granules further increased at higher throughput. Although an increasing number of kneading discs was found to be critical for achieving a uniform distribution of the granulation liquid, the granulation performance was hampered due to insufficient solid-liquid mixing capacity of the current kneading discs which is essential for wet granulation. Thus, a balance between material throughput and screw speed should be strived for in order to achieve a specific granulation time and solid-liquid mixing for high granulation yield. Additionally, more efforts are needed both in modification of the screw configuration as well as the geometry of the mixing elements to improve the mixing capacity of the twin-screw granulator. The results from the current experimental study improved the understanding regarding the interplay between granulation time and the axial and solid-liquid mixing responsible for the granulation performance in twin-screw wet granulation.

Collaboration


Dive into the Mikko Juuti's collaboration.

Top Co-Authors

Avatar

Maunu Toiviainen

VTT Technical Research Centre of Finland

View shared research outputs
Top Co-Authors

Avatar

Kai-Erik Peiponen

University of Eastern Finland

View shared research outputs
Top Co-Authors

Avatar

Jarkko Ketolainen

University of Eastern Finland

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Krist V. Gernaey

Technical University of Denmark

View shared research outputs
Researchain Logo
Decentralizing Knowledge