Mohamed Abd-Elhady
Eindhoven University of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Mohamed Abd-Elhady.
Heat Transfer Engineering | 2011
Mohamed Abd-Elhady; C.C.M. Rindt; Aa Anton van Steenhoven
A two-dimensional (2D) cone shape has been added to the normal circular tubes of heat exchangers to minimize the area of stagnation and to streamline the air flow around the heat exchanger tubes. An experimental setup has been developed to study the influence of the apex angle of the cone-shaped tubes on particulate fouling of heat exchangers. Fouling experiments have been performed in which calcium carbonate particles are injected during the experiments and the deposition of particles on the tubes of the heat exchanger is monitored. Four sets of experiments have been performed, in which normal cylindrical tubes and coned tubes with an apex angle of 60°, 90°, and 120° are examined. It was found that particulate fouling ceased if the apex angle of the cone-shaped tubes is smaller than 90°. The attached cones enhance the flow around the tubes of the heat exchanger, by minimizing the stagnation area and keeping the flow attached to the tubes starting from the tip of the attached cone until separation, such that particles that deposit on the top of the tubes of the heat exchanger can be removed by the air flow.
Heat Transfer Engineering | 2009
Mohamed Abd-Elhady; Ccm Camilo Rindt; van Aa Anton Steenhoven
The influence of flow direction with respect to gravity on particulate fouling of heat exchangers is investigated experimentally to determine the optimal flow direction to minimize fouling. Four orientations of flow have been investigated: horizontal flow, upward flow, downward flow, and a flow under an angle of 45°. It is observed that fouling starts at the point of stagnation irrespective of the flow direction, and also at the top of the heat exchanger tubes. Particulate fouling grows from these two points till they meet and the fouling layer covers the whole surface of the heat exchanger tube. Fouling at the upper half of the tubes is much faster than the lower half of the tubes, and the fouling rate is faster at the bottom tubes of the heat exchanger section than at the upper tubes. The best orientation for lingering particulate fouling is the downward flow, where the flow stagnation point coincides with the top point of the heat exchanger tubes and the growth of the fouling layer only starts from one point.
Heat Transfer Engineering | 2014
Mohamed Abd-Elhady; Mohammad R. Jalalirad; M. Reza Malayeri
Projectiles of various shapes and hardness are increasingly used in process industries to mitigate fouling in tubular heat exchangers. It is a common practice to inject the projectiles at the early stage of fouling, though laboratory results are quite scarce in the open literature to assess whether this is an appropriate operating procedure. The present work aims at investigating the influence of injected projectiles on the induction period of CaSO4 crystallization fouling. Fouling experiments have been performed in a plain heated tube. The projectiles were of spherical shape with diameter of 20.2 mm, that is, 1% bigger than the inner diameter of the heated tube, and were injected at various intervals. It has been observed that overall the attempted projectile reduced the induction period and thus expedited the fouling process. The asymptotic behavior of crystallization fouling is also approached more quickly but much less so than that of no injection. The induction period increased linearly with the flow velocity in case of no injection, while it was independent of the flow velocity when the projectile was injected as long as the injection rate was kept constant. Increasing the injection rate decreased the induction period and started the fouling process earlier. This is because the propulsion of projectiles induces air bubbles into the heat exchanger tube, which would in turn promote fouling to occur more quickly, and thus shorter induction periods are expected. Therefore, it is highly recommended to inject projectiles only after the induction period, to make use of the fouling-free operation during the induction period.
International Journal of Heat and Mass Transfer | 2007
Mohamed Abd-Elhady; Sh Stef Clevers; Tng Adriaans; Ccm Camilo Rindt; Jg Johan Wijers; van Aa Anton Steenhoven
Powder Technology | 2006
Mohamed Abd-Elhady; Ccm Camilo Rindt; Jg Johan Wijers; van Aa Anton Steenhoven
Advanced Powder Technology | 2010
Mohamed Abd-Elhady; S. Abd-Elhady; C.C.M. Rindt; A.A. van Steenhoven
Powder Technology | 2009
Mohamed Abd-Elhady; Ccm Camilo Rindt; van Aa Anton Steenhoven
conference; Proceedings of 6th International Conference on Heat Exchanger Fouling and Cleaning; 2005-06-05; 2005-06-10 | 2005
Mohamed Abd-Elhady; C.C.M. Rindt; Jg Johan Wijers; A. A. van Steenhoven
Archive | 2004
Mohamed Abd-Elhady; Ccm Camilo Rindt; Jg Johan Wijers; van Aa Anton Steenhoven
Annals of the Assembly for International Heat Transfer Conference 13 | 2006
Aa Anton van Steenhoven; Mohamed Abd-Elhady; J. Gabler; C.C.M. Rindt