Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mohammad R. Nezami Ranjbar is active.

Publication


Featured researches published by Mohammad R. Nezami Ranjbar.


Analytica Chimica Acta | 2012

Utilization of metabolomics to identify serum biomarkers for hepatocellular carcinoma in patients with liver cirrhosis

Habtom W. Ressom; Jun Feng Xiao; Leepika Tuli; Rency S. Varghese; Bin Zhou; Tsung Heng Tsai; Mohammad R. Nezami Ranjbar; Yi Zhao; Jinlian Wang; Cristina Di Poto; Amrita K. Cheema; Mahlet G. Tadesse; Radoslav Goldman; Kirti Shetty

Characterizing the metabolic changes pertaining to hepatocellular carcinoma (HCC) in patients with liver cirrhosis is believed to contribute towards early detection, treatment, and understanding of the molecular mechanisms of HCC. In this study, we compare metabolite levels in sera of 78 HCC cases with 184 cirrhotic controls by using ultra performance liquid chromatography coupled with a hybrid quadrupole time-of-flight mass spectrometry (UPLC-QTOF MS). Following data preprocessing, the most relevant ions in distinguishing HCC cases from patients with cirrhosis are selected by parametric and non-parametric statistical methods. Putative metabolite identifications for these ions are obtained through mass-based database search. Verification of the identities of selected metabolites is conducted by comparing their MS/MS fragmentation patterns and retention time with those from authentic compounds. Quantitation of these metabolites is performed in a subset of the serum samples (10 HCC and 10 cirrhosis) using isotope dilution by selected reaction monitoring (SRM) on triple quadrupole linear ion trap (QqQLIT) and triple quadrupole (QqQ) mass spectrometers. The results of this analysis confirm that metabolites involved in sphingolipid metabolism and phospholipid catabolism such as sphingosine-1-phosphate (S-1-P) and lysophosphatidylcholine (lysoPC 17:0) are up-regulated in sera of HCC vs. those with liver cirrhosis. Down-regulated metabolites include those involved in bile acid biosynthesis (specifically cholesterol metabolism) such as glycochenodeoxycholic acid 3-sulfate (3-sulfo-GCDCA), glycocholic acid (GCA), glycodeoxycholic acid (GDCA), taurocholic acid (TCA), and taurochenodeoxycholate (TCDCA). These results provide useful insights into HCC biomarker discovery utilizing metabolomics as an efficient and cost-effective platform. Our work shows that metabolomic profiling is a promising tool to identify candidate metabolic biomarkers for early detection of HCC cases in high risk population of cirrhotic patients.


Journal of Proteome Research | 2012

LC-MS based serum metabolomics for identification of hepatocellular carcinoma biomarkers in Egyptian cohort.

Jun Feng Xiao; Rency S. Varghese; Bin Zhou; Mohammad R. Nezami Ranjbar; Yi Zhao; Tsung Heng Tsai; Cristina Di Poto; Jinlian Wang; David Goerlitz; Yue Luo; Amrita K. Cheema; Naglaa I. Sarhan; Hanan Soliman; Mahlet G. Tadesse; Dina H. Ziada; Habtom W. Ressom

Although hepatocellular carcinoma (HCC) has been subjected to continuous investigation and its symptoms are well-known, early stage diagnosis of this disease remains difficult and the survival rate after diagnosis is typically very low (3-5%). Early and accurate detection of metabolic changes in the sera of patients with liver cirrhosis can help improve the prognosis of HCC and lead to a better understanding of its mechanism at the molecular level, thus providing patients with in-time treatment of the disease. In this study, we compared metabolite levels in sera of 40 HCC patients and 49 cirrhosis patients from Egypt by using ultraperformance liquid chromatography coupled with quadrupole time-of-flight mass spectrometer (UPLC-QTOF MS). Following data preprocessing, the most relevant ions in distinguishing HCC cases from cirrhotic controls are selected by statistical methods. Putative metabolite identifications for these ions are obtained through mass-based database search. The identities of some of the putative identifications are verified by comparing their MS/MS fragmentation patterns and retention times with those from authentic compounds. Finally, the serum samples are reanalyzed for quantitation of selected metabolites as candidate biomarkers of HCC. This quantitation was performed using isotope dilution by selected reaction monitoring (SRM) on a triple quadrupole linear ion trap (QqQLIT) coupled to UPLC. Statistical analysis of the UPLC-QTOF data identified 274 monoisotopic ion masses with statistically significant differences in ion intensities between HCC cases and cirrhotic controls. Putative identifications were obtained for 158 ions by mass based search against databases. We verified the identities of selected putative identifications including glycholic acid (GCA), glycodeoxycholic acid (GDCA), 3β, 6β-dihydroxy-5β-cholan-24-oic acid, oleoyl carnitine, and Phe-Phe. SRM-based quantitation confirmed significant differences between HCC and cirrhotic controls in metabolite levels of bile acid metabolites, long chain carnitines and small peptide. Our study provides useful insight into appropriate experimental design and computational methods for serum biomarker discovery using LC-MS/MS based metabolomics. This study has led to the identification of candidate biomarkers with significant changes in metabolite levels between HCC cases and cirrhotic controls. This is the first MS-based metabolic biomarker discovery study on Egyptian subjects that led to the identification of candidate metabolites that discriminate early stage HCC from patients with liver cirrhosis.


PLOS ONE | 2015

GC-MS Based Plasma Metabolomics for Identification of Candidate Biomarkers for Hepatocellular Carcinoma in Egyptian Cohort

Mohammad R. Nezami Ranjbar; Yue Luo; Cristina Di Poto; Rency S. Varghese; Alessia Ferrarini; Chi Zhang; Naglaa I. Sarhan; Hanan Soliman; Mahlet G. Tadesse; Dina H. Ziada; Rabindra Roy; Habtom W. Ressom

This study evaluates changes in metabolite levels in hepatocellular carcinoma (HCC) cases vs. patients with liver cirrhosis by analysis of human blood plasma using gas chromatography coupled with mass spectrometry (GC-MS). Untargeted metabolomic analysis of plasma samples from participants recruited in Egypt was performed using two GC-MS platforms: a GC coupled to single quadruple mass spectrometer (GC-qMS) and a GC coupled to a time-of-flight mass spectrometer (GC-TOFMS). Analytes that showed statistically significant changes in ion intensities were selected using ANOVA models. These analytes and other candidates selected from related studies were further evaluated by targeted analysis in plasma samples from the same participants as in the untargeted metabolomic analysis. The targeted analysis was performed using the GC-qMS in selected ion monitoring (SIM) mode. The method confirmed significant changes in the levels of glutamic acid, citric acid, lactic acid, valine, isoleucine, leucine, alpha tocopherol, cholesterol, and sorbose in HCC cases vs. patients with liver cirrhosis. Specifically, our findings indicate up-regulation of metabolites involved in branched-chain amino acid (BCAA) metabolism. Although BCAAs are increasingly used as a treatment for cancer cachexia, others have shown that BCAA supplementation caused significant enhancement of tumor growth via activation of mTOR/AKT pathway, which is consistent with our results that BCAAs are up-regulated in HCC.


Proteome Science | 2012

Ion annotation-assisted analysis of LC-MS based metabolomic experiment

Rency S. Varghese; Bin Zhou; Mohammad R. Nezami Ranjbar; Yi Zhao; Habtom W. Ressom

BackgroundAnalysis of multiple LC-MS based metabolomic studies is carried out to determine overlaps and differences among various experiments. For example, in large metabolic biomarker discovery studies involving hundreds of samples, it may be necessary to conduct multiple experiments, each involving a subset of the samples due to technical limitations. The ions selected from each experiment are analyzed to determine overlapping ions. One of the challenges in comparing the ion lists is the presence of a large number of derivative ions such as isotopes, adducts, and fragments. These derivative ions and the retention time drifts need to be taken into account during comparison.ResultsWe implemented an ion annotation-assisted method to determine overlapping ions in the presence of derivative ions. Following this, each ion is represented by the monoisotopic mass of its cluster. This mass is then used to determine overlaps among the ions selected across multiple experiments.ConclusionThe resulting ion list provides better coverage and more accurate identification of metabolites compared to the traditional method in which overlapping ions are selected on the basis of individual ion mass.


Proteome Science | 2013

Gaussian process regression model for normalization of LC-MS data using scan-level information

Mohammad R. Nezami Ranjbar; Yi Zhao; Mahlet G. Tadesse; Yue Wang; Habtom W. Ressom

BackgroundDifferences in sample collection, biomolecule extraction, and instrument variability introduce bias to data generated by liquid chromatography coupled with mass spectrometry (LC-MS). Normalization is used to address these issues. In this paper, we introduce a new normalization method using the Gaussian process regression model (GPRM) that utilizes information from individual scans within an extracted ion chromatogram (EIC) of a peak. The proposed method is particularly applicable for normalization based on analysis order of LC-MS runs. Our method uses measurement variabilities estimated through LC-MS data acquired from quality control samples to correct for bias caused by instrument drift. Maximum likelihood approach is used to find the optimal parameters for the fitted GPRM. We review several normalization methods and compare their performance with GPRM.ResultsTo evaluate the performance of different normalization methods, we consider LC-MS data from a study where metabolomic approach is utilized to discover biomarkers for liver cancer. The LC-MS data were acquired by analysis of sera from liver cancer patients and cirrhotic controls. In addition, LC-MS runs from a quality control (QC) sample are included to assess the run to run variability and to evaluate the ability of various normalization method in reducing this undesired variability. Also, ANOVA models are applied to the normalized LC-MS data to identify ions with intensity measurements that are significantly different between cases and controls.ConclusionsOne of the challenges in using label-free LC-MS for quantitation of biomolecules is systematic bias in measurements. Several normalization methods have been introduced to overcome this issue, but there is no universally applicable approach at the present time. Each data set should be carefully examined to determine the most appropriate normalization method. We review here several existing methods and introduce the GPRM for normalization of LC-MS data. Through our in-house data set, we show that the GPRM outperforms other normalization methods considered here, in terms of decreasing the variability of ion intensities among quality control runs.


International Journal of Oncology | 2016

Metabolomic profiling of breast tumors using ductal fluid

Luisa Matos Do Canto; Catalin Marian; Rency S. Varghese; Jaeil Ahn; Patricia A. Da Cunha; Shawna C. Willey; Mary Sidawy; Janice D. Rone; Amrita K. Cheema; George Luta; Mohammad R. Nezami Ranjbar; Habtom W. Ressom; Bassem R. Haddad

Identification of new biomarkers for breast cancer remains critical in order to enhance early detection of the disease and improve its prognosis. Towards this end, we performed an untargeted metabolomic analysis of breast ductal fluid using an ultra-performance liquid chromatography coupled with a quadrupole time-of-light (UPLC-QTOF) mass spectrometer. We investigated the metabolomic profiles of breast tumors using ductal fluid samples collected by ductal lavage (DL). We studied fluid from both the affected breasts and the unaffected contralateral breasts (as controls) from 43 women with confirmed unilateral breast cancer. Using this approach, we identified 1560 ions in the positive mode and 538 ions in the negative mode after preprocessing of the UPLC-QTOF data. Paired t-tests applied on these data matrices identified 209 ions (positive and negative modes combined) with significant change in intensity level between affected and unaffected control breasts (adjusted P-values <0.05). Among these, 83 ions (39.7%) showed a fold change (FC) >1.2 and 66 ions (31.6%) were identified with putative compound names. The metabolites that we identified included endogenous metabolites such as amino acid derivatives (N-Acetyl-DL-tryptophan) or products of lipid metabolism such as N-linoleoyl taurine, trans-2-dodecenoylcarnitine, lysophosphatidylcholine LysoPC(18:2(9Z,12Z)), glycerophospholipids PG(18:0/0:0), and phosphatidylserine PS(20:4(5Z,8Z,11Z,14Z). Generalized LASSO regression further selected 21 metabolites when race, menopausal status, smoking, grade and TNM stage were adjusted for. A predictive conditional logistic regression model, using the LASSO selected 21 ions, provided diagnostic accuracy with the area under the curve of 0.956 (sensitivity/specificity of 0.907/0.884). This is the first study that shows the feasibility of conducting a comprehensive metabolomic profiling of breast tumors using breast ductal fluid to detect changes in the cellular microenvironment of the tumors and shows the potential for this approach to be used to improve detection of breast cancer.


BMC Bioinformatics | 2015

SIMAT: GC-SIM-MS data analysis tool

Mohammad R. Nezami Ranjbar; Cristina Di Poto; Yue Joseph Wang; Habtom W. Ressom

BackgroundGas chromatography coupled with mass spectrometry (GC-MS) is one of the technologies widely used for qualitative and quantitative analysis of small molecules. In particular, GC coupled to single quadrupole MS can be utilized for targeted analysis by selected ion monitoring (SIM). However, to our knowledge, there are no software tools specifically designed for analysis of GC-SIM-MS data. In this paper, we introduce a new R/Bioconductor package called SIMAT for quantitative analysis of the levels of targeted analytes. SIMAT provides guidance in choosing fragments for a list of targets. This is accomplished through an optimization algorithm that has the capability to select the most appropriate fragments from overlapping chromatographic peaks based on a pre-specified library of background analytes. The tool also allows visualization of the total ion chromatograms (TIC) of runs and extracted ion chromatograms (EIC) of analytes of interest. Moreover, retention index (RI) calibration can be performed and raw GC-SIM-MS data can be imported in netCDF or NIST mass spectral library (MSL) formats.ResultsWe evaluated the performance of SIMAT using two GC-SIM-MS datasets obtained by targeted analysis of: (1) plasma samples from 86 patients in a targeted metabolomic experiment; and (2) mixtures of internal standards spiked in plasma samples at varying concentrations in a method development study. Our results demonstrate that SIMAT offers alternative solutions to AMDIS and MetaboliteDetector to achieve accurate detection of targets and estimation of their relative intensities by analysis of GC-SIM-MS data.ConclusionsWe introduce a new R package called SIMAT that allows the selection of the optimal set of fragments and retention time windows for target analytes in GC-SIM-MS based analysis. Also, various functions and algorithms are implemented in the tool to: (1) read and import raw data and spectral libraries; (2) perform GC-SIM-MS data preprocessing; and (3) plot and visualize EICs and TICs.


international conference on bioinformatics | 2012

Normalization of LC-MS data using Gaussian process

Mohammad R. Nezami Ranjbar; Mahlet G. Tadesse; Yue Joseph Wang; Habtom W. Ressom

The purpose of normalization of data generated by liquid chromatography coupled with mass spectrometry (LC-MS) is to reduce bias due to differences in sample collection, biomolecule extraction, and instrument variability. In this paper, we introduce a Gaussian process model for normalization based on analysis order of the samples. Specifically, we use measurement variabilities estimated using quality control (QC) samples to correct for bias caused by instrument drift. Maximum likelihood approach is used to find the optimal parameters for the fitted Gaussian process. The performance of the proposed normalization method is compared with other methods that use the analysis order information for normalization.


bioinformatics and biomedicine | 2011

Quality assessment of LC-MS metabolomic data

Mohammad R. Nezami Ranjbar; Yue Joseph Wang; Habtom W. Ressom

Liquid Chromatography — Mass Spectrometry (LC-MS) is a promising high throughput technology to measure changes in metabolites present in human samples. However, LC-MS metabolomic data need to be carefully preprocessed to remove the effects of systematic bias and noise caused by the complex nature of human samples, presence of large number of metabolites, analytical variability and instrument noise. Without appropriate data preprocessing, these issues can mislead the interpretation of results from subsequent statistical analysis. In this study, we discuss problems with reproducibility of LC-MS metabolomic data and provide suggestions to detect and overcome these issues through quality assessment approaches and by means of appropriate experimental design. We present specific examples of the most common issues and discuss possible strategies to address them.


Cancer Epidemiology, Biomarkers & Prevention | 2017

Metabolomic Characterization of Hepatocellular Carcinoma in Patients with Liver Cirrhosis for Biomarker Discovery

Cristina Di Poto; Alessia Ferrarini; Yi Zhao; Rency S. Varghese; Chao Tu; Yiming Zuo; Minkun Wang; Mohammad R. Nezami Ranjbar; Yue Luo; Chi Zhang; C. Desai; Kirti Shetty; Mahlet G. Tadesse; Habtom W. Ressom

Background: Metabolomics plays an important role in providing insight into the etiology and mechanisms of hepatocellular carcinoma (HCC). This is accomplished by a comprehensive analysis of patterns involved in metabolic alterations in human specimens. This study compares the levels of plasma metabolites in HCC cases versus cirrhotic patients and evaluates the ability of candidate metabolites in distinguishing the two groups. Also, it investigates the combined use of metabolites and clinical covariates for detection of HCC in patients with liver cirrhosis. Methods: Untargeted analysis of metabolites in plasma from 128 subjects (63 HCC cases and 65 cirrhotic controls) was conducted using gas chromatography coupled to mass spectrometry (GC-MS). This was followed by targeted evaluation of selected metabolites. LASSO regression was used to select a set of metabolites and clinical covariates that are associated with HCC. The performance of candidate biomarkers in distinguishing HCC from cirrhosis was evaluated through a leave-one-out cross-validation based on area under the receiver operating characteristics (ROC) curve. Results: We identified 11 metabolites and three clinical covariates that differentiated HCC cases from cirrhotic controls. Combining these features in a panel for disease classification using support vector machines (SVM) yielded better area under the ROC curve compared with alpha-fetoprotein (AFP). Conclusions: This study demonstrates the combination of metabolites and clinical covariates as an effective approach for early detection of HCC in patients with liver cirrhosis. Impact: Further investigation of these findings may improve understanding of HCC pathophysiology and possible implication of the metabolites in HCC prevention and diagnosis. Cancer Epidemiol Biomarkers Prev; 26(5); 675–83. ©2016 AACR.

Collaboration


Dive into the Mohammad R. Nezami Ranjbar's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Amrita K. Cheema

Georgetown University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Yi Zhao

Georgetown University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bin Zhou

Georgetown University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge