Mohammed A. Al-Rawhani
University of Glasgow
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Mohammed A. Al-Rawhani.
IEEE Transactions on Biomedical Engineering | 2013
Mohammed A. Al-Rawhani; Danial Chitnis; James Beeley; Steve Collins; David R. S. Cumming
We report on the design, fabrication, testing, and packaging of a miniaturized system capable of detecting autofluorescence (AF) from mammalian intestinal tissue. The system comprises an application-specific integrated circuit (ASIC), light-emitting diode, optical filters, control unit, and radio transmitter. The ASIC contains a high-voltage charge pump and single-photon avalanche diode detector (SPAD). The charge pump biases the SPAD above its breakdown voltage to operate in Geiger mode. The SPAD offers a photon detection efficiency of 37% at 520 nm, which corresponds to the AF emission peak of the principle human intestinal fluorophore, flavin adenine dinucleotide. The ASIC was fabricated using a commercial triple-well high-voltage CMOS process. The complete device operates at 3 V and draws an average of 7.1 mA, enabling up to 23 h of continuous operation from two 165-mAh SR44 batteries.
Scientific Reports | 2016
Mohammed A. Al-Rawhani; James Beeley; David R. S. Cumming
Fluorescence Imaging (FI) is a powerful technique in biological science and clinical medicine. Current FI devices that are used either for in-vivo or in-vitro studies are expensive, bulky and consume substantial power, confining the technique to laboratories and hospital examination rooms. Here we present a miniaturised wireless fluorescence endoscope capsule with low power consumption that will pave the way for future FI systems and applications. With enhanced sensitivity compared to existing technology we have demonstrated that the capsule can be successfully used to image tissue autofluorescence and targeted fluorescence via fluorophore labelling of tissues. The capsule incorporates a state-of-the-art complementary metal oxide semiconductor single photon avalanche detector imaging array, miniaturised optical isolation, wireless technology and low power design. When in use the capsule consumes only 30.9 mW, and deploys very low-level 468 nm illumination. The device has the potential to replace highly power-hungry intrusive optical fibre based endoscopes and to extend the range of clinical examination below the duodenum. To demonstrate the performance of our capsule, we imaged fluorescence phantoms incorporating principal tissue fluorophores (flavins) and absorbers (haemoglobin). We also demonstrated the utility of marker identification by imaging a 20 μM fluorescein isothiocyanate (FITC) labelling solution on mammalian tissue.
international symposium on circuits and systems | 2011
Mohammed A. Al-Rawhani; David R. S. Cumming; Danial Chitnis; Steve Collins
A diagnostic pill is required to reach parts of the gastrointestinal tract that are inaccessible to endoscopes and detect the fluorescence from cancer cells. The key component of this pill is a very sensitive light detector that is compact enough to be integrated within the pill. In this paper, a charge pump is described that can bias a single photon avalanche detector as effectively as a bench top power supply.
IEEE Transactions on Biomedical Circuits and Systems | 2016
Boon Chong Cheah; Alasdair I. MacDonald; Christopher Martin; Angelos J. Streklas; Gordon Campbell; Mohammed A. Al-Rawhani; Balazs Nemeth; James Grant; Michael P. Barrett; David R. S. Cumming
We have created a novel chip-based diagnostic tools based upon quantification of metabolites using enzymes specific for their chemical conversion. Using this device we show for the first time that a solid-state circuit can be used to measure enzyme kinetics and calculate the Michaelis-Menten constant. Substrate concentration dependency of enzyme reaction rates is central to this aim. Ion-sensitive field effect transistors (ISFET) are excellent transducers for biosensing applications that are reliant upon enzyme assays, especially since they can be fabricated using mainstream microelectronics technology to ensure low unit cost, mass-manufacture, scaling to make many sensors and straightforward miniaturisation for use in point-of-care devices. Here, we describe an integrated ISFET array comprising 216 sensors. The device was fabricated with a complementary metal oxide semiconductor (CMOS) process. Unlike traditional CMOS ISFET sensors that use the Si3N4 passivation of the foundry for ion detection, the device reported here was processed with a layer of Ta2O5 that increased the detection sensitivity to 45 mV/pH unit at the sensor readout. The drift was reduced to 0.8 mV/hour with a linear pH response between pH 2-12. A high-speed instrumentation system capable of acquiring nearly 500 fps was developed to stream out the data. The device was then used to measure glucose concentration through the activity of hexokinase in the range of 0.05 mM-231 mM, encompassing glucoses physiological range in blood. Localised and temporal enzyme kinetics of hexokinase was studied in detail. These results present a roadmap towards a viable personal metabolome machine.
Sensors | 2017
Fraser Stewart; Yongqiang Qiu; Holly S. Lay; Ian P. Newton; Benjamin F. Cox; Mohammed A. Al-Rawhani; James Beeley; Yangminghao Liu; Zhihong Huang; David R. S. Cumming; Inke S. Näthke; S. Cochran
Video capsule endoscopy (VCE) is now a clinically accepted diagnostic modality in which miniaturized technology, an on-board power supply and wireless telemetry stand as technological foundations for other capsule endoscopy (CE) devices. However, VCE does not provide therapeutic functionality, and research towards therapeutic CE (TCE) has been limited. In this paper, a route towards viable TCE is proposed, based on multiple CE devices including important acoustic sensing and drug delivery components. In this approach, an initial multimodal diagnostic device with high-frequency quantitative microultrasound that complements video imaging allows surface and subsurface visualization and computer-assisted diagnosis. Using focused ultrasound (US) to mark sites of pathology with exogenous fluorescent agents permits follow-up with another device to provide therapy. This is based on an US-mediated targeted drug delivery system with fluorescence imaging guidance. An additional device may then be utilized for treatment verification and monitoring, exploiting the minimally invasive nature of CE. While such a theranostic patient pathway for gastrointestinal treatment is presently incomplete, the description in this paper of previous research and work under way to realize further components for the proposed pathway suggests it is feasible and provides a framework around which to structure further work.
internaltional ultrasonics symposium | 2016
Holly S. Lay; Y. Qiu; Mohammed A. Al-Rawhani; James Beeley; Romans Poltarjonoks; Vipin Seetohul; David R. S. Cumming; S. Cochran; Gerard Cummins; Marc Phillipe Yves Desmulliez; Margeaux Wallace; Susan Trolier-McKinstry; Rachael McPhillips; Benjamin F. Cox; C. Demore
Current clinical standards for endoscopy in the gastrointestinal (GI) tract combine high definition optics and ultrasound imaging to view the lumen superficially and through its thickness. However, these instruments are limited to the length of an endoscope and the only clinically available, autonomous devices able to travel the full length of the GI tract easily offer only video capsule endoscopy (VCE). Our work seeks to overcome this limitation with a device (“Sonopill”) for multimodal capsule endoscopy, providing optical and microultrasound (μUS) imaging and supporting sensors1.μUS transducers have been developed with multiple piezoelectric materials operating across a range of centre frequencies to study viability in the GI tract. Because of the combined constraints of μUS imaging and the low power / heat tolerance of autonomous devices, a hybrid approach has been taken to the transducer design, with separate transmit and receive arrays allowing multiple manufacturing approaches to maximise system efficiency. To explore these approaches fully, prototype devices have been developed with PVDF, high-frequency PZT and PMN-PT composites, and piezoelectric micromachined ultrasonic transducer arrays. Test capsules have been developed using 3D printing to investigate issues including power consumption, heat generation / dissipation, acoustic coupling, signal strength and capsule integrity. Because of the high functional density of the electronics in our proposed system, application specific integrated circuits (ASICs) have been developed to realise the ultrasound transmit and receive circuitry along with white-light and autofluorescence imaging with singlephoton avalanche detectors (SPADs). The ultrasound ASIC has been developed and the SPAD electronics and optical subsystem have been validated experimentally. The functionality of various transducer materials.
Applied Physics Letters | 2013
Anne Bernassau; Mohammed A. Al-Rawhani; James Beeley; David R. S. Cumming
A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup.
IEEE Transactions on Circuits and Systems | 2018
Christos Giagkoulovits; Boon Chong Cheah; Mohammed A. Al-Rawhani; Claudio Accarino; Christoph Busche; James Grant; David R. S. Cumming
There is a requirement for an electrochemical sensor technology capable of making multivariate measurements in environmental, healthcare, and manufacturing applications. Here, we present a new device that is highly parallelized with an excellent bandwidth. For the first time, electrochemical cross-talk for a chip-based sensor is defined and characterized. The new CMOS electrochemical sensor chip is capable of simultaneously taking multiple, independent electroanalytical measurements. The chip is structured as an electrochemical cell microarray, comprised of a microelectrode array connected to embedded self-contained potentiostats. Speed and sensitivity are essential in dynamic variable electrochemical systems. Owing to the parallel function of the system, rapid data collection is possible while maintaining an appropriately low-scan rate. By performing multiple, simultaneous cyclic voltammetry scans in each of the electrochemical cells on the chip surface, we are able to show (with a cell-to-cell pitch of 456
IEEE Sensors Journal | 2018
Chunxiao Hu; Mohammed A. Al-Rawhani; Boon Chong Cheah; Srinivas Velugotla; David R. S. Cumming
\mu \text{m}
international symposium on circuits and systems | 2017
Mohammed A. Al-Rawhani; Boon Chong Cheah; Christos Giagkoulovits; Abdul Shakoor; Bence Nagy; James Beeley; David R. S. Cumming
) that the signal cross-talk is only 12% between nearest neighbors in a ferrocene rich solution. The system opens up the possibility to use multiple independently controlled electrochemical sensors on a single chip for applications in DNA sensing, medical diagnostics, environmental sensing, the food industry, neuronal sensing, and drug discovery.