Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Moritz Hoevels is active.

Publication


Featured researches published by Moritz Hoevels.


Clinical Cancer Research | 2004

Delineation of Brain Tumor Extent with [11C]l-Methionine Positron Emission Tomography Local Comparison with Stereotactic Histopathology

Lutz W. Kracht; Hrvoje Miletic; Susanne Busch; Andreas H. Jacobs; Jürgen Voges; Moritz Hoevels; Johannes C. Klein; Karl Herholz; Wolf-Dieter Heiss

Purpose: Methyl-[11C]l-methionine ([11C]MET) positron emission tomography (PET) in brain tumors reflects amino acid transport and has been shown to be more sensitive than magnetic resonance imaging in stereotactic biopsy planning. It remains unclear whether the increased [11C]MET uptake is limited to solid tumor tissue or even detects infiltrating tumor parts. Experimental Design: In 30 patients, a primary or recurrent brain tumor was suspected on magnetic resonance imaging. Patients were investigated with [11C]MET-PET before stereotactic biopsy. The biopsy trajectories were plotted into the [11C]MET-PET images with a newly designed C-based software program. The exact local [11C]MET uptake was determined within rectangular regions of interest of 4 mm in width and length aligned with the biopsy specimen. Individual histologic specimens were rated for the presence of solid tumor tissue, infiltration area, and nontumorous tissue changes. Results: Receiver operating characteristics analysis demonstrated a sensitivity of 87% and specificity of 89% for the detection of tumor tissue at a threshold of 1.3-fold [11C]MET uptake relative to normal brain tissue. At this threshold, only 13 of 100 tumor positive specimen were false negative mainly in grade 2 astrocytoma. In grade 2 astrocytoma, mean [11C]MET uptake in the infiltration area was significantly higher than in solid tumor tissue (P < 0.003). Conclusions: [11C]MET-PET detects solid parts of brain tumors, as well as the infiltration area at high sensitivity and specificity. High [11C]MET uptake in infiltrating tumor of astrocytoma WHO grade 2 reflects high activity in this tumor compartment. Molecular imaging, with [11C]MET, will guide improved management of patients with brain tumors.


Radiotherapy and Oncology | 2000

Computer simulation of cytotoxic and vascular effects of radiosurgery in solid and necrotic brain metastases

Martin Kocher; Harald Treuer; Jürgen Voges; Moritz Hoevels; Volker Sturm; Rolf-Peter Müller

PURPOSE Solid and necrotic brain tumors respond to radiosurgery, although necrotic lesions often contain a significant proportion of hypoxic cells which cannot become reoxygenated during the short overall treatment time of single dose application. In addition to the direct cytotoxic action, delayed vascular occlusion followed by ischemic tumor cell death could contribute to the effect of radiosurgery. MATERIALS AND METHODS In order to determine the impact of the two possible effects on tumor response, a 3-dimensional computer simulation was developed and fitted to response data obtained from 90 patients who were treated by LINAC radiosurgery for 1-3 brain metastases with median marginal doses of 20 Gy. Complete response rates were as follows: small, solid lesions (diameter 0.4-1 cm), 52% (12/23); large solid lesions (1.1-5.2 cm), 28% (17/60); large necrotic lesions, 12% (6/50). The 3-dimensional computer model simulated the growth of small solid and large, solid or necrotic tumors situated in a vascularized stroma. Oxygen supply, tumor cell division (cell cycle time 5 days), neovascularization, tumor cell kill by single dose irradiation (linear-quadratic model, alpha/beta=10 Gy, oxygen enhancement ratio 3.0) and time-dependent vascular occlusion (alpha/beta=3 Gy) were modeled by Monte-Carlo simulation techniques. RESULTS In the presence of neovascularization, solid tumors with a hypoxic fraction of 1-2% developed. Without neoangiogenesis, central necrosis occurred, and tumors had a hypoxic fraction of 20-25%. Assuming a pure cytotoxic effect of radiosurgery, neither the dose-response relationship for the solid lesions of different size nor that for the large lesions with solid or necrotic appearance could be reproduced for any given level of radiosensitivity. This was only possible by introducing a vascular effect that led to the occlusion of >/=99% of the vessels at the border of the target volume within 1 year after irradiation. In the presence of the vascular effect, the apparent radiosensitivity of the tumor cells was increased by 50-100%. Calculations of the dose-equivalent for the vascular effect show that it contributes 19-33% of the overall effect of single dose radiosurgery. CONCLUSION This simulation study suggests that the therapeutic effect of single radiosurgery in malignant brain tumors cannot be understood without the consideration of vascular effects. The computer model might serve as a basis for exploring new treatment modalities that modify both cytotoxic and vascular effects of radiosurgery.


Neurology | 2008

STN-DBS activates the target area in Parkinson disease An FDG-PET study

Rüdiger Hilker; Jürgen Voges; T. Weber; Lutz W. Kracht; Julia Roggendorf; Simon Baudrexel; Moritz Hoevels; Volker Sturm; Wolf-Dieter Heiss

Objective: The immediate effects of deep brain stimulation (DBS) on subcortical neurons of its target region are controversial. Methods: We measured the regional normalized resting cerebral metabolic rate of glucose (nCMRGlc) with 18-fluorodeoxyglucose (FDG) and PET in 12 patients with Parkinson disease (PD) and bilateral DBS of the subthalamic nucleus (STN) compared to 10 age-matched controls. PET was performed before surgery and 6 months after electrode implantation in DBS off- and on-conditions. Stereotactic coordinates of active STN electrode poles were determined with intraoperative skull x-ray and transferred to preoperative MR images. Subsequently, volumes of interest (VOIs) were placed around active electrode contacts, in the STN and in the globus pallidus. DBS induced changes of nCMRGlc values were determined in each VOI after PET and MRI coregistration. Results: Electrode placement without stimulation led to significant FDG uptake reduction in the electrode region and in the STN (microlesional effect). Under active DBS, the local nCMRGlc significantly increased in all VOIs under investigation. Conclusions: The data demonstrate that deep brain stimulation (DBS) induced metabolic activation of the subthalamic region and the directly connected globus pallidus which is in line with local and remote excitation of neurons by high frequency stimulation. These PET findings most likely reflect tonic driving of the DBS target area and its projection sites via ortho- and antidromic fiber conduction. We conclude that subthalamic nucleus DBS has predominant excitatory properties and does, therefore, fundamentally differ from lesional neurosurgery.


Physics in Medicine and Biology | 2000

On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers

Harald Treuer; Moritz Hoevels; K. Luyken; Andreas Gierich; M. Kocher; Rolf-Peter Müller; Volker Sturm

We have developed a densitometric method for measuring the isocentric accuracy and the accuracy of marking the isocentre position for linear accelerator based radiosurgery with circular collimators and room lasers. Isocentric shots are used to determine the accuracy of marking the isocentre position with room lasers and star shots are used to determine the wobble of the gantry and table rotation movement, the effect of gantry sag, the stereotactic collimator alignment, and the minimal distance between gantry and table rotation axes. Since the method is based on densitometric measurements, beam spot stability is implicitly tested. The method developed is also suitable for quality assurance and has proved to be useful in optimizing isocentric accuracy. The method is simple to perform and only requires a film box and film scanner for instrumentation. Thus, the method has the potential to become widely available and may therefore be useful in standardizing the description of linear accelerator based radiosurgical systems.


Physics in Medicine and Biology | 2004

The influence of head frame distortions on stereotactic localization and targeting

Harald Treuer; Stefan Hunsche; Moritz Hoevels; K. Luyken; Mohammed Maarouf; Jürgen Voges; Volker Sturm

A strong attachment of a stereotactic head frame to the patients skull may cause distortions of the head frame. The aim of this work was to identify possible distortions of the head frame, to measure the degree of distortion occurring in clinical practice and to investigate its influence on stereotactic localization and targeting. A model to describe and quantify the distortion of the Riechert-Mundinger (RM) head frame was developed. Distortions were classified as (a) bending and (b) changes from the circular ring shape. Ring shape changes were derived from stereotactic CT scans and frame bending was determined from intraoperative stereotactic x-ray images of patients with implanted 125I-seeds acting as landmarks. From the examined patient data frame bending was determined to be 0.74 mm+/-0.32 mm and 1.30 mm in maximum. If a CT-localizer with a top ring is used, frame bending has no influence on stereotactic CT-localization. In stereotactic x-ray localization, frame bending leads to an overestimation of the z-coordinate by 0.37 mm+/-0.16 mm on average and by 0.65 mm in maximum. The accuracy of patient positioning in radiosurgery is not affected by frame bending. But in stereotactic surgery with an RM aiming bow trajectory displacements are expected. These displacements were estimated to be 0.36 mm+/-0.16 mm (max. 0.74 mm) at the target point and 0.65 mm+/-0.30 mm (max. 1.31 mm) at the entry point level. Changes from the circularring shape are small and do not compromise the accuracy of stereotactic targeting and localization. The accuracy of CT-localization was found to be close to the resolution limit due to voxel size. Our findings for frame bending of the RM frame could be validated by statistical analysis and by comparison with an independent patient examination. The results depend on the stereotactic system and details of the localizers and instruments and also reflect our clinical practice. Therefore, a generalization is not possible. Preliminary experience with a new MR-compatible RM head frame made of ceramics shows no frame distortions as with the conventional frame made of an Al-Cu-Mg alloy.


Physics in Medicine and Biology | 1998

Computerized optimization of multiple isocentres in stereotactic convergent beam irradiation

U Treuer; Harald Treuer; Moritz Hoevels; Rolf-Peter Müller; Volker Sturm

A method for the fully computerized determination and optimization of positions of target points and collimator sizes in convergent beam irradiation is presented. In conventional interactive trial and error methods, which are very time consuming, the treatment parameters are chosen according to the operators experience and improved successively. This time is reduced significantly by the use of a computerized procedure. After the definition of target volume and organs at risk in the CT or MR scans, an initial configuration is created automatically. In the next step the target point positions and collimator diameters are optimized by the program. The aim of the optimization is to find a configuration for which a prescribed dose at the target surface is approximated as close as possible. At the same time dose peaks inside the target volume are minimized and organs at risk and tissue surrounding the target are spared. To enhance the speed of the optimization a fast method for approximate dose calculation in convergent beam irradiation is used. A possible application of the method for calculating the leaf positions when irradiating with a micromultileaf collimator is briefly discussed. The success of the procedure has been demonstrated for several clinical cases with up to six target points.


Physics in Medicine and Biology | 2004

MR-guided stereotactic neurosurgery?comparison of fiducial-based and anatomical landmark transformation approaches

Stefan Hunsche; Dieter Sauner; Mohammed Maarouf; Moritz Hoevels; K. Luyken; Oliver Schulte; K. Lackner; Volker Sturm; Harald Treuer

For application in magnetic resonance (MR) guided stereotactic neurosurgery, two methods for transformation of MR-image coordinates in stereotactic, frame-based coordinates exist: the direct stereotactic fiducial-based transformation method and the indirect anatomical landmark method. In contrast to direct stereotactic MR transformation, indirect transformation is based on anatomical landmark coregistration of stereotactic computerized tomography and non-stereotactic MR images. In a patient study, both transformation methods have been investigated with visual inspection and mutual information analysis. Comparison was done for our standard imaging protocol, including t2-weighted spin-echo as well as contrast enhanced t1-weighted gradient-echo imaging. For t2-weighted spin-echo imaging, both methods showed almost similar and satisfying performance with a small, but significant advantage for fiducial-based transformation. In contrast, for t1-weighted gradient-echo imaging with more geometric distortions due to field inhomogenities and gradient nonlinearity than t2-weighted spin-echo imaging, mainly caused by a reduced bandwidth per pixel, anatomical landmark transformation delivered markedly better results. Here, fiducial-based transformation yielded results which are intolerable for stereotactic neurosurgery. Mean Euclidian distances between both transformation methods were 0.96 mm for t2-weighted spin-echo and 1.67 mm for t1-weighted gradient-echo imaging. Maximum deviations were 1.72 mm and 3.06 mm, respectively.


Physics in Medicine and Biology | 2015

Voxel-based dose calculation in radiocolloid therapy of cystic craniopharyngiomas

Harald Treuer; Moritz Hoevels; K Luyken; Andreas Gierich; A Hellerbach; B Lachtermann; V Visser-Vandewalle; M Ruge; J Wirths

Very high doses are administered in radiocolloid therapy of cystic craniopharyngiomas. However individual dose planning is not common yet mainly due to insufficient image resolution. Our aim was to investigate whether currently available high-resolution image data can be used for voxel-based dose calculation for short-ranged β-emitters ((32)P,(90)Y,(186)Re) and to assess the achievable accuracy. We developed a convolution algorithm based on voxelized dose activity distributions and dose-spread kernels. Results for targets with 5-40 mm diameter were compared with high-resolution Monte Carlo calculations in spherical phantoms. Voxel size was 0.35 mm. Homogeneous volume and surface activity distributions were used. Dose-volume histograms of targets and shell structures were compared and γ index (dose tolerance 5%, distance to agreement 0.35 mm) was calculated for dose profiles along the principal axes. For volumetric activity distributions 89.3% ± 11.9% of all points passed the γ test (mean γ 0.53  ±  0.16). For surface distributions 33.6% ± 14.8% of all points passed the γ test (mean γ 2.01  ±  0.60). The shift of curves in dose-volume histograms was -1.7 Gy ± 7.6 Gy (-4.4 Gy ± 24.1 Gy for (186)Re) in volumetric distributions and 46.3% ± 32.8% in surface distributions. The results show that individual dose planning for radiocolloid therapy of cystic craniopharyngiomas based on high-resolution voxelized image data is feasible and yields highly accurate results for volumetric activity distributions and reasonable dose estimates for surface distributions.


Strahlentherapie Und Onkologie | 2015

Authors’ reply to “Dosimetric of intracranial stereotactic radiosurgery: only ‘an exercise of style’”

Harald Treuer; Moritz Hoevels; Klaus Luyken; Veerle Visser-Vandewalle; Jochen Wirths; Martin Kocher; Maximilian I. Ruge

We thank Dr. Fiorentino and colleagues for their interest in our article comparing dosimetric treatment plan quality in intracranial stereotactic radiosurgery (SRS) [12]. The purpose of our study was to test whether robotic radiosurgery can create at least equivalent treatment plans when compared to classical SRS with a linear accelerator (linac-SRS). Linac-SRS with conical collimators or a micro-multileaf collimator is widely used and a well-established clinical standard for the treatment of small intracranial target volumes [7, 10]. Treatment plan comparisons allow, if they are carried out properly, reliable statements to be made about the clinical utility of a new irradiation method or new radiation device [9]. Since plan comparisons can generally be carried out using a matched pair analysis, the required number of cases investigated can be kept low. Usually about 10 cases (range 1–15) are used in the literature [1, 3, 5, 6, 8, 9]. Vice versa, methodological requirements for meaningful plan


Strahlentherapie Und Onkologie | 2013

Endocrine and visual function after fractionated stereotactic radiotherapy of perioptic tumors

Mininder S. Kocher; Harald Treuer; Moritz Hoevels; Robert Semrau; Volker Sturm; Rolf-Peter Mueller

Collaboration


Dive into the Moritz Hoevels's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jürgen Voges

Otto-von-Guericke University Magdeburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

K. Luyken

University of Cologne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge