Mu Baozhong
Tongji University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Mu Baozhong.
Chinese Physics Letters | 2007
Zhang Zhong; Wang Zhanshan; Zhu Jingtao; Wu Yong-Rong; Mu Baozhong; Wang Feng-Li; Qin Shu-Ji; Chen Ling-yan
Ni/Ti multilayers, which can be used for neutron monochromators, are designed, fabricated and measured. Firstly, their reflectivities are simulated based on the Nevot–Croce model. Reflectivities of two Ni/Ti multilayer mirrors with periods d = 10.3 nm (M1) and d = 7.8 nm (M2) are calculated. In the calculation, the reflectivity of the Ni/Ti multilayer is taken as a function of the grazing angle with different roughness factors δ = 1.0 nm and δ = 1.5 nm. Secondly, these two multilayers are fabricated by the direct current magnetron sputtering technology. Thirdly their structures are characterized by small-angle x-ray diffraction. The roughness factors are fitted to be 0.68 nm and 1.16 nm for M1 and M2, respectively. Finally their reflective performances are measured on the V14 neutron beam line at the Berlin Neutron Scattering Centre (BENSC), Germany. The experimental data show that the grazing angle of the reflected neutron intensity peak increases, but the reflected neutron intensity decreases, with the decreasing periods of the multilayers.
SCIENTIA SINICA Physica, Mechanica & Astronomica | 2018
Cao Zhurong; Yuan Zheng; Chen Tao; Deng Bo; Wang Qiangqiang; Deng Keli; Yang Zhiwen; Li Jin; Miao Wen-Yong; Jiang Wei; Yuan Yongteng; Li Yukun; Hu Xin; Zhang Ji-Yan; Dong Jianjun; Ding Yongkun; Mu Baozhong; Wang Feng; Liu Shenye; Yang Jia-Min; Jiang Shao-En; Zhang Bao-Han
In the field of indirect-drive inertial confinement fusion, temporal and spatial diagnosis of X-ray is very important to the imploded process researches and the simulate procedure verification. According to the temporal, spatial and spectral characteristics of X-ray radiation, many X-ray imaging diagnosis devices were successfully developed. Along with the development of ICF research, especially the Shenguang III facility establishment, our X-ray imaging diagnosis capability has been increasingly powerful. Some of the novel diagnosis equipment even have more excellent characteristics than that kind of diagnosis equipment abroad.
Archive | 2013
Yi Shengzhen; Mu Baozhong; Wang Xin; Wang Zhanshan; Zhang Yizhou
Archive | 2015
Mu Baozhong; Zhang Yizhou; Yi Shengzhen; Wang Xin; Zhu Jingtao; Wang Zhanshan
Archive | 2015
Yi Shengzhen; Mu Baozhong; Wang Zhanshan; Zhang Yizhou; Wang Xin
Archive | 2016
Li Wenbin; Wang Zhanshan; Wang Xin; Yuan Xiaofeng; Xu Haizhao; Mu Baozhong
Archive | 2015
Mu Baozhong; Zhang Yizhou; Yi Shengzhen; Wang Xin; Wang Zhanshan
Archive | 2014
Mu Baozhong; Yi Shengzhen; Wang Zhanshan
Archive | 2013
Wang Xin; Wang Ling; Mu Baozhong; Yi Shengzhen; Wang Zhanshan
High Power Laser and Particle Beams | 2011
Wang Xin; Mu Baozhong; Huang Yi; Zhai Zirong; Yi Shengzhen; Jiang Li; Zhu Jingtao; Wang Zhanshan; Liu Hongjie; Cao Leifeng; Gu Yuqiu