Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Muhammet Guler is active.

Publication


Featured researches published by Muhammet Guler.


Materials Science and Engineering: C | 2018

A novel nonenzymatic hydrogen peroxide amperometric sensor based on Pd@CeO 2 -NH 2 nanocomposites modified glassy carbon electrode

Muhammet Guler; Vedat Turkoglu; Arif Kivrak; Fatih Karahan

Herein, (3-aminopropyl)triethoxysilane functionalized cerium (IV) oxide (CeO2-NH2) supported Pd nanoparticles were synthesized. The nanocomposites were characterized using Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and High-resolution transmission electron microscopy (HRTEM). The Pd@CeO2-NH2 showed better electrocatalytic response to the reduction of H2O2 than CeO2-NH2. The fabricated sensor exhibited two linear responses to the reduction of H2O2. The first one was from 0.001 to 3.276 mM with 0.47 μM of a limit of detection (LOD) (S/N = 3) and excellent sensitivity of 440.72 μA mM-1 cm-2 and the second one was from 3.276 to 17.500 mM with the sensitivity of 852.65 μA mM-1 cm-2 in the optimum conductions. Also, the sensor exhibited 91% of electrocatalytic activity toward H2O2 after having been used for 30 days and the reproducibility was also satisfactory. The sensor response to H2O2 was not affected by ascorbic acid, fructose, glycine, dopamine, arginine, mannose, glucose, uric acid, Mg+2, Ca+2, and phenylalanine at the studied potential. Also, the fabricated sensor was used to determine H2O2 in milk samples. The results show that the constructed sensor can be a promising devise for the determination of H2O2 in real samples.


Hacettepe Journal of Biology and Chemistry | 2016

In Vitro Inhibition of Human Plasma and Erythrocyte AChE by Various Drugs

Mehmet Rıza Kıvanç; Vedat Turkoglu; Muhammet Guler; Zehra Basi

Bu çalışmada; yapısal olarak farklı olan sekiz antibiyotik (sefazolin, kanamisin, gentamisin, klindamisin, ivermektin ve ampisilin) ve ağrı kesicinin (metamizol ve diklofenak) insan eritrosit ve plazma asetilkolinesteraz (AChE; EC 3.1.1.7) enzimi üzerine in vitro etkileri araştırılmıştır. Bu amaçla; farklı derişimlere sahip ilaçların neden olduğu inhibisyonu belirlemek için ilaçların IC 50 ve K I değerleri hesaplandı. Asetilkolinesteraz aktivitesi spektrofotometrik olarak Ellman yöntemiyle belirlendi. Daha sonra, ilaçlara maruz kalan enzim aktivitesi ölçüldü. AChE aktivitesine karşı ilaç derişimi ve Michealis-Menten grafikleri çizildi. Son olarak, bu grafikler yardımıyla IC 50 ve K ı değerleri hesaplandı. IC 50 değerleri, plazma AChE’sine diklofenak için 1.78 x10 M ve eritrosit AChE’sine gentamisin için 0.85 x10 M olduğu belirlendi. K I değerleri ise diklofenak için 1.36 x10 M ve gentamisin için 1.16 x10 M olarak hesaplandı. Ayrıca, ivermektin, klindamisin, kanamisin, ampisilin için IC 50 ve K I değerleri elde edildi. Diklofenak, plazma AChE aktivitesi üzerine gentamisin de eritrosit AChE aktivitesi üzerine en yüksek inhibitör etkisi göstermiştir. Bulunan bu değerlerin daha önce yapılan benzer çalışmalardaki inhibisyon değerlerinden daha yüksek olduğu görülmektedir [1,2].


Electrochimica Acta | 2017

Determination of malation, methidathion, and chlorpyrifos ethyl pesticides using acetylcholinesterase biosensor based on Nafion/Ag@rGO-NH2 nanocomposites

Muhammet Guler; Vedat Turkoglu; Zehra Basi


Environmental Science and Pollution Research | 2016

Electrochemical detection of malathion pesticide using acetylcholinesterase biosensor based on glassy carbon electrode modified with conducting polymer film

Muhammet Guler; Vedat Turkoglu; Arif Kivrak


Bulletin of Environmental Contamination and Toxicology | 2013

In vitro determination of 6PGD enzyme activity purified from Lake Van fish (Chalcalburnus tarichii Pallas, 1811) liver exposed to pesticides.

Muhammet Guler; M. Rıza Kıvanç; Vedat Turkoglu; Zehra Basi; Hilal Kivrak


Electroanalysis | 2017

A Novel Enzymatic Glucose Biosensor and Nonenzymatic Hydrogen Peroxide Sensor Based on (3-Aminopropyl) Triethoxysilane Functionalized Reduced Graphene Oxide

Muhammet Guler; Vedat Turkoglu; Mehmet Rıza Kıvanç


Electrochimica Acta | 2018

Electrochemical sensing of hydrogen peroxide using Pd@Ag bimetallic nanoparticles decorated functionalized reduced graphene oxide

Muhammet Guler; Vedat Turkoglu; Ahmet Bulut; Mehmet Zahmakiran


International Journal of Biological Macromolecules | 2015

A novel glucose oxidase biosensor based on poly([2,2';5',2″]-terthiophene-3'-carbaldehyde) modified electrode.

Muhammet Guler; Vedat Turkoglu; Arif Kivrak


Turkish Journal of Chemistry | 2018

Differential pulse voltammetric determination of dopamine using Pd nanoparticles deposited on (3-aminopropyl)triethoxysilane functionalized CeO

Muhammet Guler


Electrochimica Acta | 2018

_{2}

Muhammet Guler; Vedat Turkoglu; Ahmet Bulut; Mehmet Zahmakiran

Collaboration


Dive into the Muhammet Guler's collaboration.

Top Co-Authors

Avatar

Vedat Turkoglu

Yüzüncü Yıl University

View shared research outputs
Top Co-Authors

Avatar

Zehra Basi

Yüzüncü Yıl University

View shared research outputs
Top Co-Authors

Avatar

Arif Kivrak

Yüzüncü Yıl University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ahmet Bulut

Yüzüncü Yıl University

View shared research outputs
Top Co-Authors

Avatar

M. Rıza Kıvanç

Yüzüncü Yıl University

View shared research outputs
Top Co-Authors

Avatar

Mehmet Zahmakiran

Yüzüncü Yıl University

View shared research outputs
Top Co-Authors

Avatar

Fatih Karahan

Yüzüncü Yıl University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge