Musa Solmaz
Erciyes University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Musa Solmaz.
Transfusion and Apheresis Science | 2008
Leylagul Kaynar; Ismet Aydogdu; Burhan Turgut; Ismail Kocyigit; Sibel Hacioglu; Sevda Ismailogullari; Nilda Turgut; M. Ali Erkurt; Ismail Sari; Mehmet Oztekin; Musa Solmaz; Bulent Eser; Ali Özdemir Ersoy; Ali Unal; Mustafa Cetin
Therapeutic plasma exchange (TPE) is commonly used in many neurological disorders where an immune etiology was known or suspected. We report our experience with TPE performed for neuroimmunologic disorders at four university hospitals. The study was a retrospective review of the medical records of neurological patients (n=57) consecutively treated with TPE between April 2006 and May 2007. TPE indications in neurological diseases included Guillain-Barrè Syndrome (GBS) (n=41), myasthenia gravis (MG) (n=11), acute disseminated encephalomyelitis (ADEM) (n=3), chronic inflammatory demyelinating polyneuropathy (CIDP) (n=1) and multiple sclerosis (MS) (n=1). Patient median age was 49; there was a predominance of males. Twenty-two patients had a history of other therapy including intravenous immunoglobulin (IVIG), steroid, azothioprin, and pridostigmine prior to TPE. Another 35 patients had not received any treatment prior to TPE. All patients were classified according to the Hughes functional grading scores pre- and first day post-TPE for early clinical evaluation of patients. The TPE was carried out 1-1.5 times at the predicted plasma volume every other day. Two hundred and ninety-four procedures were performed on 57 patients. The median number of TPE sessions per patient was five, and the median processed plasma volume was 3075mL for each cycle. Although the pre-TPE median Hughes score of all patients was 4, it had decreased to grade 1 after TPE. While the pre-TPE median Hughes score for GBS and MG patients was 4, post-TPE scores were decreased to grade 1. Additionally, there was a statistically significant difference between post-TPE Hughes score for GBS patients with TPE as front line therapy and patients receiving IVIG as front line therapy (1 vs. 3.5; p=0.034). Although there was no post-TPE improvement in Hughes scores in patients with ADEM and CIDP, patients with MS had an improved Hughes score from 4 to 1. Mild and manageable complications such as hypotension and hypocalcemia were also observed. TPE may be preferable for controlling symptoms of neuroimmunological disorders in early stage of the disease, especially with GBS.
Hematology | 2017
Leylagul Kaynar; Koray Demir; Esra Ermiş Turak; Çiğdem Pala Öztürk; Gokmen Zararsiz; Zeynep Burçin Gönen; Selma Gokahmetoglu; Serdar Şıvgın; Bulent Eser; Yavuz Köker; Musa Solmaz; Ali Unal; Mustafa Cetin
ABSTRACT Introduction: The use of αβ+ T-cell-depleted grafts is a novel approach to prevent graft failure, graft-versus-host disease (GVHD), and non-relapse mortality (NRM) in patients undergoing haploidentical hematopoietic stem cell transplantation. Patient and method: Thirty-four patients with acute leukemia and lacking a match donor were treated with αβ T-cell-depleted allografts from haploidentical family donors. A total of 24 patients had acute myeloid leukemia (AML) and 10 had acute lymphoblastic leukemia. 84.4% of patients were in the high-risk group, and 55.9% were not in remission. The preparative regimen included thiotepa, melphalan, fludarabine, and anti-thymocyte globulin-Fresenius. Grafts were peripheral blood stem cells engineered by TcR-alpha/beta depletion. Results: Neutrophil and platelet engraftment was achieved on days +12 (range, 10.5–15) and +11 (range, 10–12). All but three patients were engrafted with full donor chimerism. Grade III-IV acute GVHD occurred in two (5.9%) patients and chronic GVHD in two (6.1%). Disease-free survival and overall survival were 42 and 54% at 1 year, respectively. AML as disease type (HR: 4.87, 95% CI: 1.50–15.87) and mother as donor (HR: 1.05, 95% CI: 1.00–1.11) were found to be independent risk factors on patient survival. Mortality and NRM in the first 100 days were 5 of 34 (14.7%) and 4 of 34 (11.7%). Relapse was the main cause of death (56.3%). T-cell reconstitution appears to be faster than that reported in published data with CD3/CD19-depleted grafts. Conclusion: αβ T-cell-depleted haploidentical transplantation may be a good alternative for high-risk patients if there are no human leukocyte antigen matched donors.
Transfusion and Apheresis Science | 2013
Muzaffer Keklik; Leylagul Kaynar; Mehmet Yilmaz; Serdar Sivgin; Musa Solmaz; Cigdem Pala; Sulbiye Aribas; Gulsah Akyol; K. Unluhizarci; Mustafa Cetin; Bulent Eser; Ali Unal
Hyperthyroidism characterized by elevated serum levels of circulating thyroid hormones. The aim of hyperthyroidism treatment is to achieve a euthyroid state as soon as possible and to maintain euthyroid status. However, drug withdrawal and utilization of alternative therapies are needed in cases in which leucopenia or impairment in liver functions is observed during medical therapy. In the present study, we aimed to present our cases which underwent therapeutic plasma exchange (TPE) due to severe hyperthyroidism. The results of 22 patients who underwent therapeutic plasma exchange due to hyperthyroidism in Apheresis Units of Erciyes University and Gaziantep University, between 2006 and 2012, were retrospectively reviewed. These cases had severe thyrotoxic values despite anti-thyroid drug use. After TPE, we observed a significant decrease in free thyroxin (FT4) (p<0.001) and free triiodotyhronin (FT3) (p<0.004) levels. There was statistically significant increase in the mean values of TSH levels after TPE (p<0.001). Clinical improvement was achieved in hyperthyroidism by TPE in 20 cases (91%). Both FT3 and FT4 levels remained above the normal limits in two of 22 patients. TPE should be considered as an effective and safe therapeutic option to achieve euthyroid state before surgery or radioactive iodine treatment. TPE is a useful option in cases with severe hyperthyroidism unresponsive to anti-thyroid agents and in those with clinical manifestations of cardiac failure and in patients with severe adverse events during anti-thyroid therapy.
Transfusion Medicine and Hemotherapy | 2008
Ismail Sari; Ismail Kocyigit; Leylagul Kaynar; Sibel Hacioglu; Ahmet Öztürk; Mehmet Oztekin; Musa Solmaz; Bulent Eser; Mustafa Cetin; Ali Unal
Background: A variety of apheresis devices are now available on the market for plateletapheresis. We compared two apheresis instruments (Fenwal Amicus and Fresenius COM.TEC) with regard to processing time, platelet (PLT) yield and efficiency, and white blood cell (WBC) content. Material and Methods: Donors undergoing plateletpheresis were randomly separated into two groups (either the Amicus or the COM.TEC cell separator). Results: In the pre-apheresis setting, 32 plateletpheresis procedures performed with each instrument revealed no significant differences in donors’ sex, age, weight, height and total blood volume between the two groups. However, the preapheresis PLT count was higher with the COM.TEC than with the Amicus (198 ×103/µl vs. 223 ×103/µl; p = 0.035). The blood volume processed to reach a target PLT yield of ≧3.3 ×1011 was higher in the COM.TEC compared to the Amicus (3,481 vs. 2,850 ml; p < 0.001). The median separation time was also significantly longer in the COM.TEC than in the Amicus (61 vs. 44 min; p < 0.001). 91 and 88% of the PLT products collected with the Amicus and the COM.TEC, respectively, had a PLT count of ≧3.3 ×1011 (p = 0.325). All products obtained with both instruments had WBC counts lower than 5 ↔106, as required. There was no statistical difference with regard to collection efficiency between the devices (55 ± 15 vs. 57 ± 15%; p = 0.477). However, the collection rate was significantly higher with the Amicus compared to the COM.TEC instrument (0.077 ± 0.012 ×1011 vs. 0.057 ± 0.008 ×1011 PLT/min; p < 0.001). Conclusion: Both instruments collected platelets efficiently. Additionally, consistent leukoreduction was obtained with both instruments; however, compared with the COM.TEC instrument, the Amicus reached the PLT target yield more quickly.
Journal of Clinical Apheresis | 2015
Muzaffer Keklik; Bulent Eser; Leylagul Kaynar; Serdar Sivgin; Ertugrul Keklik; Musa Solmaz; Ahmet Öztürk; Ruksan Buyukoglan; Mehmet Yay; Mustafa Cetin; Ali Unal
Blood component donations by apheresis have become more common in modern blood transfusion practices. We compared three apheresis instruments (Fenwal Amicus, Fresenius COM.TEC, and Trima Accel) with regard to platelet (PLT) yield, collection efficiency (CE), and collection rate (CR). The single‐needle or double‐needle plateletpheresis procedures of the three instruments were compared in a retrospective, randomized study in 270 donors. The blood volume processed was higher in the COM.TEC compared with the Amicus and Trima. Also there was a significantly higher median volume of ACD used in collections on the COM.TEC compared with the Amicus and Trima. The PLT yield was significantly lower with the COM.TEC compared with the Amicus and Trima. Additionally, the CE was significantly lower with the COM.TEC compared with the Amicus and Trima. There was no significant difference in median separation time and CR between the three groups. When procedures were compared regarding CE by using Amicus device, it was significantly higher in single‐needle than double‐needle plateletpheresis. When double‐needle Amicus system was compared with double‐needle COM.TEC system, CE and PLT yield were significantly higher with Amicus system. When single‐needle Amicus system was compared with single‐needle Trima system, CE and PLT yield were significantly higher with Trima system. All instruments collected PLTs efficiently. However, the CE was lower with the COM.TEC compared with the Amicus and Trima. Also, we found Amicus single‐needle system collected PLTs more efficiently compared with the double‐needle system. CE and PLT yields were significantly higher with the single‐needle Trima instrument compared with the single‐needle Amicus device. J. Clin. Apheresis 30:171–175, 2015.
Transfusion and Apheresis Science | 2014
Muzaffer Keklik; Bulent Eser; Leylagul Kaynar; Musa Solmaz; Ahmet Öztürk; Mehmet Yay; Ayse Birekul; Mehmet Oztekin; Serdar Sivgin; Mustafa Cetin; Ali Unal
BACKGROUND A variety of apheresis instruments are now available on the market for double dose plateletpheresis. We compared three apheresis devices (Fenwal Amicus, Fresenius COM.TEC and Trima Accel) with regard to processing time, platelet (PLT) yield, collection efficiency (CE) and collection rate (CR). STUDY DESIGN AND METHODS The single-needle or double-needle double plateletpheresis procedures of the three instruments were compared in a retrospective, randomized study in 135 donors. RESULTS In the pre-apheresis setting, 45 double plateletpheresis procedures performed with each instrument revealed no significant differences in donors age, sex, weight, hemoglobin, white blood cell and PLT count between three groups. The blood volume processed to reach a target PLT yield of ≥ 6 × 10(11) was higher in the COM.TEC compared with the Amicus and Trima (4394 vs. 3780 and 3340 ml, respectively; p < 0.001). Also there was a significantly higher median volume of ACD used in collections on the COM.TEC compared with the Amicus and Trima (426 vs. 387 and 329 ml, respectively; p < 0.001). There was a significantly higher median time needed for the procedures on the COM.TEC compared with the Amicus and Trima (66 vs. 62 and 63 min, respectively; p = 0.024). The CE was significantly higher with the Trima compared with the Amicus and COM.TEC (83.57 ± 17.19 vs. 66.71 ± 3.47 and 58.79 ± 5.14%, respectively; p < 0.001). Also, there was a significantly higher product volume on the Trima compared with the Amicus and COM.TEC (395.56 vs. 363.11 and 386.4 ml, respectively; p = 0.008). Additionally, the CR was significantly lower with the COM.TEC compared with the Amicus and Trima (0.092 ± 0.011 vs. 0.099 ± 0.013 and 0.097 ± 0.013 plt × 10(11)/min, respectively; p = 0.039). There was no significant differences in PLT yield between the three groups (p = 0.636). CONCLUSIONS Trima single-needle device collected double dose platelets more efficiently than Amicus and COM.TEC double-needle devices. Blood volume processed, ACD-A volume, and median separation time was significantly higher with the COM.TEC. Also, the CR was significantly lower with the COM.TEC.
Transfusion and Apheresis Science | 2013
Muzaffer Keklik; Serdar Sivgin; Leylagul Kaynar; Cigdem Pala; Musa Solmaz; Mustafa Cetin; Bulent Eser; Ali Unal
Hyperbilirubinemia is a common clinical manifestation, and may be life threatening. Many diseases result in hyperbilirubinemias, some are refractory, and cannot be cured by medication or surgery. Plasma exchange (PE) for hyperbilirubinemia is not a pathogenesis oriented therapy but strives for the opportunity to cure. In the present study, we aimed to present the outcomes of treatment of hyperbilirubinemia with PE in patients with various disorders. Eleven patients who underwent PE due to hyperbilirubinemia between 2006 and 2012 in Apheresis Unit of Erciyes University, were retrospectively reviewed. After PE, we observed a marked decline in total and direct bilirubin levels. The decline in the biochemical values were statically significant (p<0.003). Both total and direct bilirubin levels remained above the normal limits in one of 11 patients. PE should be considered as an effective and safe option in cases with hyperbilirubinemia, and this procedure can improve survival in patients with sufficient residual capacity of liver regeneration.
Transfusion and Apheresis Science | 2013
Muzaffer Keklik; Serdar Sivgin; Burhan Sami Kalin; Gulsah Akyol; Cigdem Pala; Musa Solmaz; Leylagul Kaynar; Bulent Eser; Mustafa Cetin; Ali Unal
Ataxia-telangiectasia (AT) is a hereditary disorder characterized by progressive neurological dysfunction, oculocutaneous telangiectasia, immunodeficiency, cancer susceptibility, and radiation sensitivity. Pediatric patients may develop acute lymphoblastic leukemia (ALL). However development of ALL in an adult patient with AT is a rare occurrence. Here we report such a patient who presented with hyperleukocytosis and were treated with leukapheresis. A 25years old male patient, who were diagnosed with AT and mental retardation, was admitted to the emergency department due to fatigue, nausea and headache. On admission he had a moderate general condition and was fully cooperated. His white blood cell (WBC) count were 466×10(9)/l. Blastic cells were observed in peripheral blood smear. Flow cytometry (FC) of peripheral blood showed T-ALL. Two sessions of large volume leukapheresis was performed. Symptoms due to hyperleukocytosis markedly improved after leukapheresis. Patients with AT should be closely monitored due to risk of malignancy. Leukapheresis may improve the prognosis of high risk ALL patients presenting with hyperleukocytosis.
Transfusion | 2013
Fatih Kurnaz; Serdar Sivgin; Cigdem Pala; Rahsan Yildirim; Suleyman Baldane; Leylagul Kaynar; Musa Solmaz; Ahmet Öztürk; Bulent Eser; Mustafa Cetin; Ali Unal
Extreme leukocytosis, generally defined as a white blood cell (WBC) count of more than 100 × 109/L consisting largely of blast cells, especially when accompanied by clinical signs and symptoms of leukostasis or hyperviscosity, often predicts a poor clinical outcome in patients with acute leukemia. In this study, we aimed to investigate the effect of volume replacement (VR) during therapeutic leukapheresis (TA) procedure on early mortality rate and WBC reduction.
Turkish Journal of Hematology | 2011
Fatih Kardas; Aysun Çetin; Musa Solmaz; Ruksan Buyukoglan; Leylagul Kaynar; Mustafa Kendirci; Bulent Eser; Ali Unal
Objective: The aim of this study was to report the efficacy of low-density lipoprotein cholesterol (LDL-C) apheresisusing a cascade filtration system in pediatric patients with homozygous familial hypercholesterolemia (FH), and toclarify the associated adverse effects and difficulties. Material and Methods: LDL-C apheresis using a cascade filtration system was performed in 3 pediatric patientswith homozygous FH; in total, 120 apheresis sessions were performed. Results: Cascade filtration therapy significantly reduced the mean LDL-C values from 418 ± 62 mg/dL to 145 ± 43 mg/dL (p= 0.011). We observed an acute mean reduction in the plasma level of total cholesterol (57.9%), LDL-C (70.8%),and high-density lipoprotein cholesterol (HDL-C) (40.7%). Treatments were well tolerated. The most frequent clinicaladverse effects were hypotension in 3 sessions (2.5%), chills (1.7%) in 2 sessions, and nausea/vomiting in 3 sessions(2.5%). Conclusion: Our experience using the cascade filtration system with 3 patients included good clinical outcomes andlaboratory findings, safe usage, and minor adverse effects and technical problems. Conflict of interest:None declared.