Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Natalia Gudino is active.

Publication


Featured researches published by Natalia Gudino.


Magnetic Resonance in Medicine | 2013

On-coil multiple channel transmit system based on class-D amplification and pre-amplification with current amplitude feedback

Natalia Gudino; Jeremiah A. Heilman; Matthew J. Riffe; Oliver Heid; Markus Vester; Mark A. Griswold

A complete high‐efficiency transmit amplifier unit designed to be implemented in on‐coil transmit arrays is presented. High power capability, low power dissipation, scalability, and cost minimization were some of the requirements imposed to the design. The system is composed of a current mode class‐D amplifier output stage and a voltage mode class‐D preamplification stage. The amplitude information of the radio frequency pulse was added through a customized step‐down DC‐DC converter with current amplitude feedback that connects to the current mode class‐D stage. Benchtop measurements and imaging experiments were carried out to analyze system performance. Direct control of B1 was possible and its load sensitivity was reduced to less than 10% variation from unloaded to full loaded condition. When using the amplifiers in an array configuration, isolation above 20 dB was achieved between neighboring coils by the amplifier decoupling method. High output current operation of the transmitter was proved on the benchtop through output power measurements and in a 1.5T scanner through flip angle quantification. Finally, single and multiple channel excitations with the new hardware were demonstrated by receiving signal with the body coil of the scanner. Magn Reson Med, 2013.


Magnetic Resonance in Medicine | 2012

Parallel excitation for B‐field insensitive fat‐saturation preparation

Jeremiah A. Heilman; Jamal D. Derakhshan; Matthew J. Riffe; Natalia Gudino; Jean A. Tkach; Chris A. Flask; Jeffrey L. Duerk; Mark A. Griswold

Multichannel transmission has the potential to improve many aspects of MRI through a new paradigm in excitation. In this study, multichannel transmission is used to address the effects that variations in B0 homogeneity have on fat‐saturation preparation through the use of the frequency, phase, and amplitude degrees of freedom afforded by independent transmission channels. B1 homogeneity is intrinsically included via use of coil sensitivities in calculations. A new method, parallel excitation for B‐field insensitive fat‐saturation preparation, can achieve fat saturation in 89% of voxels with Mz ≤ 0.1 in the presence of ±4 ppm B0 variation, where traditional CHESS methods achieve only 40% in the same conditions. While there has been much progress to apply multichannel transmission at high field strengths, particular focus is given here to application of these methods at 1.5 T. Magn Reson Med, 2012.


Magnetic Resonance in Medicine | 2013

Identification and mitigation of interference sources present in SSB-based wireless MRI receiver arrays

Matthew J. Riffe; Michael D. Twieg; Natalia Gudino; Colin J. Blumenthal; Jeremiah A. Heilman; Mark A. Griswold

Single sideband amplitude modulation (SSB) is an appealing platform for highly parallel wireless MRI detector arrays because the spacing between channels is ideally limited only by the MRI signal bandwidth. However this assumes that no other sources of interference are present outside that bandwidth. This work investigates the practical interference between multiple SSB‐encoded MRI signals.


Magnetic Resonance in Medicine | 2013

Multi-Turn Transmit Coil to Increase B1 Efficiency in Current Source Amplification

Natalia Gudino; Mark A. Griswold

A multi‐turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification.


Archive | 2010

Hall effect current sensor

Natalia Gudino; Matthew J. Riffe; Jeremiah A. Heilman; Mark A. Griswold


Archive | 2010

SWITCHED MODE PRE-AMPLIFICATION AND AM FEEDBACK FOR ON-COIL SWITCHED MODE AMPLIFIERS IN PARALLEL TRANSMISSION MRI

Natalia Gudino; Jeremiah A. Heilman; Mark A. Griswold; Markus Vester


Archive | 2011

Switched mode pre-amplification and AM feedback for on-coil switched mode amplifiers

Natalia Gudino; Heilman Jeremiah A; Griswold Mark A; Markus Vester


Archive | 2010

On-coil current mode class d rf power amplifier in high field parallel transmission mri

Natalia Gudino; Jeremiah A. Heilman; Mark A. Griswold


Archive | 2008

Control of Intravascular Catheters Using a 3D Array of Active Steering Coils for and Interventional MRI setting

Natalia Gudino


Archive | 2009

DEVICE WITH 3D ARRAY OF STEERING COILS

Mark A. Griswold; Natalia Gudino; Jeremiah A. Heilman

Collaboration


Dive into the Natalia Gudino's collaboration.

Top Co-Authors

Avatar

Mark A. Griswold

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar

Jeremiah A. Heilman

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar

Matthew J. Riffe

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar

Markus Vester

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar

Chris A. Flask

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jamal D. Derakhshan

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar

Jean A. Tkach

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar

Jeffrey L. Duerk

Case Western Reserve University

View shared research outputs
Top Co-Authors

Avatar

Markus Vester

Case Western Reserve University

View shared research outputs
Researchain Logo
Decentralizing Knowledge