Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Nell I. Matthews is active.

Publication


Featured researches published by Nell I. Matthews.


Transfusion | 2011

Red blood cell (RBC) survival determined in humans using RBCs labeled at multiple biotin densities

Donald M. Mock; Nell I. Matthews; Shan Zhu; Ronald G. Strauss; Robert L. Schmidt; Demet Nalbant; Gretchen A. Cress; John A. Widness

BACKGROUND: Safe, accurate methods permitting simultaneous and/or repeated measurement of red blood cell (RBC) survival (RCS) are important to investigate pathophysiology and therapy of anemia. Methods using chromium 51 (51Cr)‐labeled RBCs are unacceptable for infants, children, and pregnant women. We report RCS measured in vivo using RBCs labeled with several densities of biotin (BioRBCs).


Molecular Genetics and Metabolism | 2011

DEVELOPMENT AND CHARACTERIZATION OF A MOUSE WITH PROFOUND BIOTINIDASE DEFICIENCY: A BIOTIN-RESPONSIVE NEUROCUTANEOUS DISORDER

Kirit Pindolia; Megan Jordan; Caiying Guo; Nell I. Matthews; Donald M. Mock; Erin T. Strovel; Miriam G. Blitzer; Barry Wolf

Biotinidase deficiency is the primary enzymatic defect in biotin-responsive, late-onset multiple carboxylase deficiency. Untreated children with profound biotinidase deficiency usually exhibit neurological symptoms including lethargy, hypotonia, seizures, developmental delay, sensorineural hearing loss and optic atrophy; and cutaneous symptoms including skin rash, conjunctivitis and alopecia. Although the clinical features of the disorder markedly improve or are prevented with biotin supplementation, some symptoms, once they occur, such as developmental delay, hearing loss and optic atrophy, are usually irreversible. To prevent development of symptoms, the disorder is screened for in the newborn period in essentially all states and in many countries. In order to better understand many aspects of the pathophysiology of the disorder, we have developed a transgenic biotinidase-deficient mouse. The mouse has a null mutation that results in no detectable serum biotinidase activity or cross-reacting material to antibody prepared against biotinidase. When fed a biotin-deficient diet these mice develop neurological and cutaneous symptoms, carboxylase deficiency, mild hyperammonemia, and exhibit increased urinary excretion of 3-hydroxyisovaleric acid and biotin and biotin metabolites. The clinical features are reversed with biotin supplementation. This biotinidase-deficient animal can be used to study systematically many aspects of the disorder and the role of biotinidase, biotin and biocytin in normal and in enzyme-deficient states.


The American Journal of Clinical Nutrition | 2010

Plasma concentration of 3-hydroxyisovaleryl carnitine is an early and sensitive indicator of marginal biotin deficiency in humans

Shawna L. Stratton; Thomas D. Horvath; Anna Bogusiewicz; Nell I. Matthews; Cindy L Henrich; Horace J. Spencer; Jeffery H. Moran; Donald M. Mock

BACKGROUND Blood-based indicators of biotin status in humans were shown to be useful tools in several clinical situations, including pregnancy. We previously validated the activity of the biotin-dependent enzyme propionyl-coenzyme A carboxylase (PCC) in lymphocytes as a sensitive and specific blood-based indicator of marginal degrees of biotin deficiency. However, the measurement of PCC activity in population studies presents substantial analytic challenges. 3-Hydroxyisovaleryl carnitine (3HIA-carnitine) increases in response to the decreased activity of the biotin-dependent enzyme methylcrotonyl-coenzyme A carboxylase and might reflect biotin status. OBJECTIVE We sought to determine whether the plasma concentration of 3HIA-carnitine increases significantly in marginal biotin deficiency. DESIGN We experimentally induced marginal, asymptomatic biotin deficiency in 10 healthy adults (8 women) by having the subjects consume undenatured egg white for 28 d; biotin status was then repleted. Plasma concentrations of 3HIA-carnitine were measured on days 0, 14, 28, 35, and 50 by liquid chromatography-mass spectroscopy. RESULTS The mean plasma 3HIA-carnitine concentration increased with depletion (P < 0.0001) and decreased with repletion (P < 0.0001). Plasma 3HIA-carnitine concentrations were greater than the upper limit of normal concentrations in 7 of 10 subjects by day 14 and in 9 of 10 subjects by day 28 and decreased to within normal limits in 9 of 10 subjects by day 50. CONCLUSIONS These studies provide evidence that 3HIA-carnitine is an early and sensitive indicator of marginal biotin deficiency. The ease of sample collection, small sample volume requirement, and stability of 3HIA-carnitine during storage suggest that plasma 3HIA-carnitine concentration is likely to be a useful indicator of marginal biotin deficiency for larger population studies.


Transfusion | 2009

Red blood cell volume can be independently determined in vitro using sheep and human red blood cells labeled at different densities of biotin.

Donald M. Mock; Nell I. Matthews; Ronald G. Strauss; Leon F. Burmeister; Robert L. Schmidt; John A. Widness

BACKGROUND: The development of valid methods for repeatedly measuring red blood cell (RBC) volume (RCV) in the same individual would be useful in furthering understanding of the physiology and pathophysiology of the pregnant woman, fetus, and infant under a variety of conditions.


Journal of Nutrition | 2011

Urinary Excretion of 3-Hydroxyisovaleric Acid and 3-Hydroxyisovaleryl Carnitine Increases in Response to a Leucine Challenge in Marginally Biotin-Deficient Humans

Donald M. Mock; Shawna L. Stratton; Thomas D. Horvath; Anna Bogusiewicz; Nell I. Matthews; Cindy L Henrich; Amanda M. Dawson; Horace J. Spencer; Suzanne N. Owen; Gunnar Boysen; Jeffery H. Moran

Experimentally increasing metabolic flux in a pathway in which an essential step is catalyzed by a vitamin-dependent enzyme (a challenge test) has been used in assessing functional vitamin status and elucidating common and alternate metabolic pathways. Conversion of 3-methylcrotonyl CoA to 3-methylglutaconyl CoA in the leucine catabolic pathway is catalyzed by the biotin-dependent enzyme methylcrotonyl-CoA carboxylase (MCC). Marginal biotin deficiency reduces MCC activity and increases urinary excretion of 3-hydroxyisovaleric acid (3HIA) and 3-hydroxyisovaleryl carnitine (3HIA-carnitine) measured in 24-h urine collections. We assessed urinary excretion of 3HIA and 3HIA-carnitine in response to a leucine challenge in humans made progressively biotin deficient by egg white consumption. In 2 cohorts of healthy adults (Study 1: n = 5; Study 2: n = 7) rendered biotin deficient over 28 d, urinary excretion of 3HIA and 3HIA-carnitine in response to a leucine challenge was quantitated weekly for 3 or 4 wk, respectively. In both studies, mean urinary excretion of both 3HIA and 3HIA-carnitine increased >2-fold by d 14 (P < 0.002 for both indicators for both studies). Diagnostically, both indicators were highly sensitive, but diagnostic sensitivities were not superior to those of 24-h excretion of 3HIA and 3HIA-carnitine. These studies provide evidence that urinary excretions of 3HIA and 3HIA-carnitine in response to an oral leucine challenge are early and sensitive indicators of marginal biotin deficiency in humans. The variability of the proportion of leucine catabolites excreted as 3HIA suggests substantial population heterogeneity in the metabolic capacity of the 3HIA-carnitine detoxification pathway.


Transfusion | 2011

Red blood cell (RBC) volume can be independently determined in vivo in humans using RBCs labeled at different densities of biotin

Donald M. Mock; Nell I. Matthews; Shan Zhu; Leon F. Burmeister; M. Bridget Zimmerman; Ronald G. Strauss; Robert L. Schmidt; Demet Nalbant; Gretchen A. Cress; John A. Widness

BACKGROUND: Anemia is a serious problem in critically ill neonates. To investigate the pathophysiology of anemia and responses to red blood cell (RBC) transfusions and erythropoietin therapy, repeated measurement of red blood cell volume (RCV) and blood volume is useful. To extend our previous sheep study in which RBCs were labeled at four different biotin densities, we assessed the validity of this multidensity method for in vivo measurement of circulating RCV in humans.


Journal of Nutrition | 2011

Urinary Excretion of 3-Hydroxyisovaleryl Carnitine Is an Early and Sensitive Indicator of Marginal Biotin Deficiency in Humans

Shawna L. Stratton; Thomas D. Horvath; Anna Bogusiewicz; Nell I. Matthews; Cindy L Henrich; Horace J. Spencer; Jeffery H. Moran; Donald M. Mock

Mounting evidence indicates that marginal biotin deficiency is not rare, contrary to previous assumptions. Accordingly, robust indicators of biotin status would be useful. In a study of 10 healthy adults, we recently provided evidence that abnormally increased plasma concentration of 3-hydroxyisovaleryl carnitine (3HIA-carnitine) is a sensitive indicator of marginal biotin deficiency. We sought to determine whether urinary excretion of 3HIA-carnitine (expressed as the ratio to urinary creatinine) significantly increases in marginal biotin deficiency. Marginal, asymptomatic biotin deficiency was induced experimentally in the same 10 healthy adults (8 women) by feeding undenatured egg white with meals for 28 d. Biotin status was repleted by a mixed general diet plus biotin supplementation. Urinary excretion of 3HIA-carnitine was determined by liquid chromatography-tandem MS on d 0, 14, and 28 (depletion) and on d 35 and 50 (repletion). Mean urinary 3HIA-carnitine concentration increased with depletion (P < 0.0001; d 0 vs. 28) and decreased with repletion (P = 0.0002; d 28 vs. 50). Urinary 3HIA-carnitine excretion was greater than the upper limit of normal in 9 of 10 participants by d 14 and decreased to within normal limits by d 50 in all participants. This study provides evidence that urinary excretion of 3HIA-carnitine is an early and sensitive indicator of marginal biotin deficiency. The ease of collection of untimed urine samples and application of a new analytical method with simplified sample preparation suggest that urinary 3HIA-carnitine is likely to be a useful indicator for large population studies.


Pediatric Research | 2013

Comparison of multiple red cell volume methods performed concurrently in premature infants following allogeneic transfusion

Demet Nalbant; Prasad Bhandary; Nell I. Matthews; Robert L. Schmidt; Anna Bogusiewicz; Gretchen A. Cress; M. Bridget Zimmerman; Ronald G. Strauss; Donald M. Mock; John A. Widness

Background:Study of the pathophysiology and treatment of anemia of prematurity is facilitated by direct measurement of red cell volume (RCV) utilizing microliter quantities of blood samples. Our objective was to compare concurrent measurements of multiple direct RCV methods in infants.Methods:Eighteen preterm infants receiving clinically indicated transfusions had concurrent flow cytometric determinations of RCV and 24-h red blood cell (RBC) recovery based on donor–recipient differences of biotin-labeled RBCs (BioRBCs), Kidd antigen mismatched RBCs, and fetal hemoglobin–positive (HbF+) RBCs. High-performance liquid chromatography (HPLC) was also used for measuring HbF and adult hemoglobin protein concentrations for the determination of RCV.Results:Concurrent RCV measurements using BioRBCs (18 and 54 µg/ml), Kidd antigen, and HbF flow cytometry were not statistically different compared with RCVs measured using the reference BioRBC density (6 µg/ml). By contrast, the HbF-HPLC method overestimated RCV by 45% compared with the reference method. All the methods demonstrated 100% 24-h posttransfusion RBC recovery (PTR24).Conclusion:Because BioRBC, Kidd antigen, and fetal hemoglobin (HbF) flow cytometry are safe and accurate methods requiring <10 µl of patient blood for determining RCV and PTR24 in preterm infants, they can be useful in clinical and research studies of anemia and other conditions.


Transfusion | 2010

Red blood cell (RBC) volume can be independently determined in vivo in the sheep using ovine RBCs labeled at different densities of biotin.

Donald M. Mock; Nell I. Matthews; Shan Zhu; Leon F. Burmeister; M. Bridget Zimmerman; Ronald G. Strauss; Robert L. Schmidt; Demet Nalbant; Kevin J. Freise; Peter Veng-Pedersen; John A. Widness

BACKGROUND: To investigate the pathophysiology of anemia and responses to red blood cell (RBC) transfusions and erythropoietin, repeated measurement of the circulating red blood cell volume (RCV) would be useful. Ovine erythropoiesis is similar to human erythropoiesis. Accordingly, a method for measuring RCV using either human or sheep RBCs labeled at different biotin densities has been previously validated in vitro. Here preclinical studies validating this method for in vivo measurement of circulating RCV in sheep are reported.


Pediatric Research | 2013

Tracking donor RBC survival in premature infants: agreement of multiple populations of biotin-labeled RBCs with Kidd antigen-mismatched RBCs.

John A. Widness; Demet Nalbant; Nell I. Matthews; Ronald G. Strauss; Robert L. Schmidt; Gretchen A. Cress; Miriam Bridget Zimmerman; Donald M. Mock

Background:Anemia, a common condition among critically ill premature infants, is affected by red blood cell (RBC) survival (RCS). We hypothesized that transfused allogeneic Kidd antigen–mismatched RBCs would demonstrate the same concurrent RCS tracking as RBCs multilabeled at separate, discrete low densities with biotin (BioRBCs).Methods:Allogeneic RBCs from adult donors were labeled at four biotin densities, mixed, and transfused into 17 anemic premature infants. Nine of the donors and neonates were Kidd antigen mismatched. Serial posttransfusion blood samples were assayed for up to 8 wk by flow cytometry to track the survival of the proportions of Kidd antigen–mismatched and Kidd antigen–biotinylated RBCs.Results:Using linear mixed modeling to compare results, RCS of the three lowest BioRBC densities was similar to RCS by Kidd antigen mismatch and to one another. RCS of RBCs labeled at the highest BioRBC density was shortened.Conclusion:RCS of different populations of RBCs can be tracked concurrently and reliably using the three lowest BioRBC densities. Although comparable RCS results can be achieved using Kidd antigen mismatches, BioRBCs are preferred for investigating neonatal anemia because biotin labeling of both allogeneic and autologous RBCs is possible.

Collaboration


Dive into the Nell I. Matthews's collaboration.

Top Co-Authors

Avatar

Donald M. Mock

University of Arkansas for Medical Sciences

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Anna Bogusiewicz

University of Arkansas for Medical Sciences

View shared research outputs
Top Co-Authors

Avatar

Shawna L. Stratton

University of Arkansas for Medical Sciences

View shared research outputs
Researchain Logo
Decentralizing Knowledge