Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Nicholas Petrick is active.

Publication


Featured researches published by Nicholas Petrick.


Medical Physics | 2002

Lung nodule detection on thoracic computed tomography images: preliminary evaluation of a computer-aided diagnosis system.

Metin N. Gurcan; Berkman Sahiner; Nicholas Petrick; Heang Ping Chan; Ella A. Kazerooni; Philip N. Cascade; Lubomir M. Hadjiiski

We are developing a computer-aided diagnosis (CAD) system for lung nodule detection on thoracic helical computed tomography (CT) images. In the first stage of this CAD system, lung regions are identified by a k-means clustering technique. Each lung slice is classified as belonging to the upper, middle, or the lower part of the lung volume. Within each lung region, structures are segmented again using weighted k-means clustering. These structures may include true lung nodules and normal structures consisting mainly of blood vessels. Rule-based classifiers are designed to distinguish nodules and normal structures using 2D and 3D features. After rule-based classification, linear discriminant analysis (LDA) is used to further reduce the number of false positive (FP) objects. We performed a preliminary study using 1454 CT slices from 34 patients with 63 lung nodules. When only LDA classification was applied to the segmented objects, the sensitivity was 84% (53/63) with 5.48 (7961/1454) FP objects per slice. When rule-based classification was used before LDA, the free response receiver operating characteristic (FROC) curve improved over the entire sensitivity and specificity ranges of interest. In particular, the FP rate decreased to 1.74 (2530/1454) objects per slice at the same sensitivity. Thus, compared to FP reduction with LDA alone, the inclusion of rule-based classification lead to an improvement in detection accuracy for the CAD system. These preliminary results demonstrate the feasibility of our approach to lung nodule detection and FP reduction on CT images.


Medical Physics | 1998

Computerized analysis of mammographic microcalcifications in morphological and texture feature spaces

Heang Ping Chan; Berkman Sahiner; Kwok L. Lam; Nicholas Petrick; Mark A. Helvie; Mitchell M. Goodsitt; Dorit D. Adler

We are developing computerized feature extraction and classification methods to analyze malignant and benign microcalcifications on digitized mammograms. Morphological features that described the size, contrast, and shape of microcalcifications and their variations within a cluster were designed to characterize microcalcifications segmented from the mammographic background. Texture features were derived from the spatial gray-level dependence (SGLD) matrices constructed at multiple distances and directions from tissue regions containing microcalcifications. A genetic algorithm (GA) based feature selection technique was used to select the best feature subset from the multi-dimensional feature spaces. The GA-based method was compared to the commonly used feature selection method based on the stepwise linear discriminant analysis (LDA) procedure. Linear discriminant classifiers using the selected features as input predictor variables were formulated for the classification task. The discriminant scores output from the classifiers were analyzed by receiver operating characteristic (ROC) methodology and the classification accuracy was quantified by the area, Az, under the ROC curve. We analyzed a data set of 145 mammographic microcalcification clusters in this study. It was found that the feature subsets selected by the GA-based method are comparable to or slightly better than those selected by the stepwise LDA method. The texture features (Az = 0.84) were more effective than morphological features (Az = 0.79) in distinguishing malignant and benign microcalcifications. The highest classification accuracy (Az = 0.89) was obtained in the combined texture and morphological feature space. The improvement was statistically significant in comparison to classification in either the morphological (p = 0.002) or the texture (p = 0.04) feature space alone. The classifier using the best feature subset from the combined feature space and an appropriate decision threshold could correctly identify 35% of the benign clusters without missing a malignant cluster. When the average discriminant score from all views of the same cluster was used for classification, the Az value increased to 0.93 and the classifier could identify 50% of the benign clusters at 100% sensitivity for malignancy. Alternatively, if the minimum discriminant score from all views of the same cluster was used, the Az value would be 0.90 and a specificity of 32% would be obtained at 100% sensitivity. The results of this study indicate the potential of using combined morphological and texture features for computer-aided classification of microcalcifications.


Medical Physics | 1998

Computerized characterization of masses on mammograms: The rubber band straightening transform and texture analysis

Berkman Sahiner; Heang Ping Chan; Nicholas Petrick; Mark A. Helvie; Mitchell M. Goodsitt

A new rubber band straightening transform (RBST) is introduced for characterization of mammographic masses as malignant or benign. The RBST transforms a band of pixels surrounding a segmented mass onto the Cartesian plane (the RBST image). The border of a mammographic mass appears approximately as a horizontal line, and possible speculations resemble vertical lines in the RBST image. In this study, the effectiveness of a set of directional textures extracted from the images before the RBST. A database of 168 mammograms containing biopsy-proven malignant and benign breast masses was digitized at a pixel size of 100 microns x 100 microns. Regions of interest (ROIs) containing the biopsied mass were extracted from each mammogram by an experienced radiologist. A clustering algorithm was employed for automated segmentation of each ROI into a mass object and background tissue. Texture features extracted from spatial gray-level dependence matrices and run-length statistics matrices were evaluated for three different regions and representations: (i) the entire ROI; (ii) a band of pixels surrounding the segmented mass object in the ROI; and (iii) the RBST image. Linear discriminant analysis was used for classification, and receiver operating characteristic (ROC) analysis was used to evaluate the classification accuracy. Using the ROC curves as the performance measure, features extracted from the RBST images were found to be significantly more effective than those extracted from the original images. Features extracted from the RBST images yielded an area (Az) of 0.94 under the ROC curve for classification of mammographic masses as malignant and benign.


Physics in Medicine and Biology | 1995

Computer-aided classification of mammographic masses and normal tissue: linear discriminant analysis in texture feature space

Heang Ping Chan; Datong Wei; Mark A. Helvie; Berkman Sahiner; Dorit D. Adler; Mitchell M. Goodsitt; Nicholas Petrick

We studied the effectiveness of using texture features derived from spatial grey level dependence (SGLD) matrices for classification of masses and normal breast tissue on mammograms. One hundred and sixty-eight regions of interest (ROIS) containing biopsy-proven masses and 504 ROIS containing normal breast tissue were extracted from digitized mammograms for this study. Eight features were calculated for each ROI. The importance of each feature in distinguishing masses from normal tissue was determined by stepwise linear discriminant analysis. Receiver operating characteristic (ROC) methodology was used to evaluate the classification accuracy. We investigated the dependence of classification accuracy on the input features, and on the pixel distance and bit depth in the construction of the SGLD matrices. It was found that five of the texture features were important for the classification. The dependence of classification accuracy on distance and bit depth was weak for distances greater than 12 pixels and bit depths greater than seven bits. By randomly and equally dividing the data set into two groups, the classifier was trained and tested on independent data sets. The classifier achieved an average area under the ROC curve, Az, of 0.84 during training and 0.82 during testing. The results demonstrate the feasibility of using linear discriminant analysis in the texture feature space for classification of true and false detections of masses on mammograms in a computer-aided diagnosis scheme.


IEEE Transactions on Medical Imaging | 1996

An adaptive density-weighted contrast enhancement filter for mammographic breast mass detection

Nicholas Petrick; Heang Ping Chan; Berkman Sahiner; Datong Wei

Presents a novel approach for segmentation of suspicious mass regions in digitized mammograms using a new adaptive density-weighted contrast enhancement (DWCE) filter in conjunction with Laplacian-Gaussian (LG) edge detection. The DWCE enhances structures within the digitized mammogram so that a simple edge detection algorithm can be used to define the boundaries of the objects. Once the object boundaries are known, morphological features are extracted and used by a classification algorithm to differentiate regions within the image. This paper introduces the DWCE algorithm and presents results of a preliminary study based on 25 digitized mammograms with biopsy proven masses. It also compares morphological feature classification based on sequential thresholding, linear discriminant analysis, and neural network classifiers for reduction of false-positive detections.


Medical Physics | 2001

Improvement of mammographic mass characterization using spiculation measures and morphological features

Berkman Sahiner; Heang Ping Chan; Nicholas Petrick; Mark A. Helvie; Lubomir M. Hadjiiski

We are developing new computer vision techniques for characterization of breast masses on mammograms. We had previously developed a characterization method based on texture features. The goal of the present work was to improve our characterization method by making use of morphological features. Toward this goal, we have developed a fully automated, three-stage segmentation method that includes clustering, active contour, and spiculation detection stages. After segmentation, morphological features describing the shape of the mass were extracted. Texture features were also extracted from a band of pixels surrounding the mass. Stepwise feature selection and linear discriminant analysis were employed in the morphological, texture, and combined feature spaces for classifier design. The classification accuracy was evaluated using the area Az under the receiver operating characteristic curve. A data set containing 249 films from 102 patients was used. When the leave-one-case-out method was applied to partition the data set into trainers and testers, the average test Az for the task of classifying the mass on a single mammographic view was 0.83 +/- 0.02, 0.84 +/- 0.02, and 0.87 +/- 0.02 in the morphological, texture, and combined feature spaces, respectively. The improvement obtained by supplementing texture features with morphological features in classification was statistically significant (p = 0.04). For classifying a mass as malignant or benign, we combined the leave-one-case-out discriminant scores from different views of a mass to obtain a summary score. In this task, the test Az value using the combined feature space was 0.91 +/- 0.02. Our results indicate that combining texture features with morphological features extracted from automatically segmented mass boundaries will be an effective approach for computer-aided characterization of mammographic masses.


IEEE Transactions on Medical Imaging | 2001

Computer-aided characterization of mammographic masses: accuracy of mass segmentation and its effects on characterization

Berkman Sahiner; Nicholas Petrick; Heang Ping Chan; Lubomir M. Hadjiiski; Chintana Paramagul; Mark A. Helvie; Metin N. Gurcan

Mass segmentation is used as the first step in many computer-aided diagnosis (CAD) systems for classification of breast masses as malignant or benign. The goal of this paper was to study the accuracy of an automated mass segmentation method developed in our laboratory, and to investigate the effect of the segmentation stage on the overall classification accuracy. The automated segmentation method was quantitatively compared with manual segmentation by two expert radiologists (R1 and R2) using three similarity or distance measures on a data set of 100 masses. The area overlap measures between R1 and R2, the computer and R1, and the computer and R2 were 0.76/spl plusmn/0.13,0.74 /spl plusmn/0.11, and 0.74/spl plusmn/0.13, respectively. The interobserver difference in these measures between the two radiologists was compared with the corresponding differences between the computer and the radiologists. Using three similarity measures and data from two radiologists, a total of six statistical tests were performed. The difference between the computer and the radiologist segmentation was significantly larger than the interobserver variability in only one test. Two sets of texture, morphological, and spiculation features, one based on the computer segmentation, and the other based on radiologist segmentation, were extracted from a data set of 249 films from 102 patients. A classifier based on stepwise feature selection and linear discriminant analysis was trained and tested using the two feature sets. The leave-one-case-out method was used for data sampling. For case-based classification, the area A/sub z/ under the receiver operating characteristic (ROC) curve was 0.89 and 0.88 for the feature sets based on the radiologist segmentation and computer segmentation, respectively. The difference between the two ROC curves was not statistically significant.


Medical Physics | 1996

Image feature selection by a genetic algorithm: application to classification of mass and normal breast tissue.

Berkman Sahiner; Heang Ping Chan; Datong Wei; Nicholas Petrick; Mark A. Helvie; Dorit D. Adler; Mitchell M. Goodsitt

We investigated a new approach to feature selection, and demonstrated its application in the task of differentiating regions of interest (ROIs) on mammograms as either mass or normal tissue. The classifier included a genetic algorithm (GA) for image feature selection, and a linear discriminant classifier or a backpropagation neural network (BPN) for formulation of the classifier outputs. The GA-based feature selection was guided by higher probabilities of survival for fitter combinations of features, where the fitness measure was the area Az under the receiver operating characteristic (ROC) curve. We studied the effect of different GA parameters on classification accuracy, and compared the results to those obtained with stepwise feature selection. The data set used in this study consisted of 168 ROIs containing biopsy-proven masses and 504 ROIs containing normal tissue. From each ROI, a total of 587 features were extracted, of which 572 were texture features and 15 were morphological features. The GA was trained and tested with several different partitionings of the ROIs into training and testing sets. With the best combination of the GA parameters, the average test Az value using a linear discriminant classifier reached 0.90, as compared to 0.89 for stepwise feature selection. Test Az values with a BPN classifier and a more limited feature pool were 0.90 with GA-based feature selection, and 0.89 for stepwise feature selection. The use of a GA in tailoring classifiers with specific design characteristics was also discussed. This study indicates that a GA can provide versatility in the design of linear or nonlinear classifiers without a trade-off in the effectiveness of the selected features.


Radiology | 2009

Noncalcified Lung Nodules: Volumetric Assessment with Thoracic CT

Marios A. Gavrielides; Lisa M. Kinnard; Kyle J. Myers; Nicholas Petrick

Lung nodule volumetry is used for nodule diagnosis, as well as for monitoring tumor response to therapy. Volume measurement precision and accuracy depend on a number of factors, including image-acquisition and reconstruction parameters, nodule characteristics, and the performance of algorithms for nodule segmentation and volume estimation. The purpose of this article is to provide a review of published studies relevant to the computed tomographic (CT) volumetric analysis of lung nodules. A number of underexamined areas of research regarding volumetric accuracy are identified, including the measurement of nonsolid nodules, the effects of pitch and section overlap, and the effect of respiratory motion. The need for public databases of phantom scans, as well as of clinical data, is discussed. The review points to the need for continued research to examine volumetric accuracy as a function of a multitude of interrelated variables involved in the assessment of lung nodules. Understanding and quantifying the sources of volumetric measurement error in the assessment of lung nodules with CT would be a first step toward the development of methods to minimize that error through system improvements and to correctly account for any remaining error.


Medical Physics | 1996

AUTOMATED DETECTION OF BREAST MASSES ON MAMMOGRAMS USING ADAPTIVE CONTRAST ENHANCEMENT AND TEXTURE CLASSIFICATION

Nicholas Petrick; Heang Ping Chan; Datong Wei; Berkman Sahiner; Mark A. Helvie; Dorit D. Adler

This paper presents segmentation and classification results of an automated algorithm for the detection of breast masses on digitized mammograms. Potential mass regions were first identified using density-weighted contrast enhancement (DWCE) segmentation applied to single-view mammograms. Once the potential mass regions had been identified, multiresolution texture features extracted from wavelet coefficients were calculated, and linear discriminant analysis (LDA) was used to classify the regions as breast masses or normal tissue. In this article the overall detection results for two independent sets of 84 mammograms used alternately for training and test were evaluated by free-response receiver operating characteristics (FROC) analysis. The test results indicate that this new algorithm produced approximately 4.4 false positive per image at a true positive detection rate of 90% and 2.3 false positives per image at a true positive rate of 80%.

Collaboration


Dive into the Nicholas Petrick's collaboration.

Top Co-Authors

Avatar

Berkman Sahiner

Food and Drug Administration

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ronald M. Summers

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kyle J. Myers

Food and Drug Administration

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rongping Zeng

Food and Drug Administration

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge