Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Nie Li-Hua is active.

Publication


Featured researches published by Nie Li-Hua.


Journal of Biochemical and Biophysical Methods | 1996

Bulk acoustic wave sensor for investigating hemorheological characteristics of plasma and its coagulation

Si Shi-Hui; Xu Yuanjin; Nie Li-Hua; Yao Shouzhuo

A method of using a bulk acoustic wave (BAW) device to study the hemorheological phenomena is proposed. By measuring the resonant resistance of a BAW device, the dependence of the plasma viscosity on its composition is investigated. It has been found that during the process of the plasma coagulation, the frequency response of a BAW device is dominated by the change in plasma viscoelasticity, and useful information such as the coagulation time and the viscoelasticity of coagulated plasma can be obtained from the curve of frequency response. Based on the BAW quartz detection system, effects of fibrinogen, thrombin and some drugs on the plasma coagulation are investigated. The results show that the BAW device based on the oscillator method possesses some advantages, such as high sensitivity, simplicity of use, cost effectiveness and small sample volume for clinical hemorheological study.


Journal of Electroanalytical Chemistry | 1991

A new type of piezoelectric detector in liquid: Part. 1. Theoretical considerations and measurements of resonance behavior dependent on liquid properties

Mo Zhi-Hong; Nie Li-Hua; Yao Shou-Zhou

Abstract Theoretical considerations for a new type of piezoelectric detector oscillating in a liquid, a piezoelectric crystal with separated electrode (PCSE) are proposed and verified experimentally. The resonance frequency and equivalent circuit parameters of PCSE in the various solutions are measured to demonstrate the effects of liquid properties.


Analytica Chimica Acta | 1988

Selective determination of silver in solution by adsorption on a piezoelectric quartz crystal

Yao Shouzhuo; Dan Shen-Li; Nie Li-Hua

Abstract Electrodeposition of metal ions on the crystal is eliminated by using a specially constructed transistorized oscillator. When tartrate, citrate, EDTA or their mixtures are present, silver adsorption occurs. The frequency change is proportional to the silver concentration in the range 2 × 10−7−1 × 10−5 M after adsorption for 10 min from a 1 mM EDTA/3 mM tartrate solution. No significant interferences are caused by other metal ions. On the basis of cyclic voltammetric studies, it is suggested that silver is adsorbed as a silver (I) complex.


Analytical Letters | 1994

Using Piezoelectric Quartz Crystal to Study Hemorheological Phenomena: Blood Clotting and Urokinase Activated Fibrinolysis

Si Shi-Hui; Zhou Tiean; Liu Dezhong; Nie Li-Hua; Yao Shouzhuo

Abstract A piezoelectric quartz crystal (PQC) was used to study hemorheological phenomena. On the basis of equivalent circuit parameters, the frequency response corresponding to the blood clotting was discussed. The results show that the response of PQC was dominated by viscosity change at the initial stage, and then by mass effect and surface stress. With PQC monitoring the change of coagulated plasma viscosity, the urokinase activated fibrinolysis was investigated.


Analyst | 1993

Frequency characteristics of an electrode-separated piezoelectric crystal sensor in contact with a liquid

Shen Dazhong; Lin Song; Kang Qi; Nie Li-Hua; Yao Shouzhuo

The equations characterizing the frequency response of an electrode-separated piezoelectric crystal (ESPC) sensor, with one side in contact with a liquid, to the properties of the liquid were derived from an electric equivalent circuit model and supported by experiments. The frequency shift of the ESPC can provide information on the permittivity, conductivity, density and viscosity of the liquid.


Journal of Pharmaceutical and Biomedical Analysis | 1992

Determination of quinine in some pharmaceutical preparations using a ring-coated piezoelectric sensor

Nie Li-Hua; Zhang Xiao-Tung; Yao Shouzhuo

Quinine is a highly active blood schizontocide and is still used in the treatment of P. fulciparum malaria resistant to chloroquine or other antimalarial drugs. For its determination, most pharmacopoeias recommend non-aqueous titration [l-3] or an extractionweighing method [l]. Other methods that have been proposed include spectrophotometry [4], fluorimetry [5], liquid chromatography [6] and ion-selective electrode potentiometry [7]. The conventional extraction-weighing method which is based on neutralization, extraction, evaporation and weighing the quinine base is time-consuming and rather inconvenient; in addition a relatively large sample is required. The piezoelectric quartz crystal is very sensitive for weight determination and is widely used as a quartz crystal microbalance (QCM) in both science and technology [8]. In the present paper, a new method is proposed for the determination of quinine based on the use of a specially designed ring-coated piezoelectric crystal sensor. The method is simple and sensitive and enables submicrogram amounts of quinine to be determined.


Journal of Electroanalytical Chemistry | 1994

Equivalent circuits of piezoelectric quartz crystals in a liquid and liquid properties: Part 2. A unified equivalent circuit model for piezoelectric sensors

Shen Dazhong; Huang Mingshan; Nie Li-Hua; Yao Shouzhuo

Abstract A unified equivalent circuit model is proposed to simulate the electrical behavior of liquid or quasi-liquid piezoelectric sensors including normal, series, parallel and separated-electrode-piezoelectric crystal. The relationships of the resonance frequency and the effective quality factor of these piezoelectric sensors to the liquid properties (permittivity, conductivity, density and viscosity) are derived and verified experimentally. The frequency shift characteristics and effective quality factors of these piezoelectric sensors are compared.


Talanta | 1994

An impedance analyzer method to simulate the oscillating characteristic of a series piezoelectric sensor in oscillators with zero or non-zero phases.

Shen Dazhong; Xu Yuanjin; Nie Li-Hua; Yao Shouzhuo

An impedance analyzer method is employed to simulate the oscillation frequency of a series piezoelectric quartz crystal (SPQC) in electrolyte or non-electrolyte solutions. The influence of the oscillator phase on the oscillation frequency and response sensitivity are theoretically derived and experimentally verified. In non-electrolyte liquids, the oscillator phase has little effect on both the oscillation frequency and the response to the permittivity. But in electrolyte solutions, the oscillator phase has a significant influence on the oscillation frequency and the response sensitivity to the conductivity. Depending on the oscillator phase, the oscillation frequency of the SPQC may increase, be maintained or decrease with increasing conductivity in low or high conductive solutions. The dependence of the oscillation frequency of the SPQC on the supply voltage is explained. As an example of the applications, the SPQC is applied to the determination of the critical micelle concentration of ionic surfactants in aqueous solutions.


Talanta | 1989

Amphoteric tetracycline-sensitive electrodes and their selectivities

Yao Shou-Zhou; Shiao Jing; Nie Li-Hua

Electrodes that are sensitive to cationic and anionic species of tetracycline have been constructed. The cation-sensitive electrode responds to monoprotonated tetracycline over the pH range 1.9-3.2. The anion-sensitive electrode responds at pH 8.0-11.0 to the singly-charged tetracyclinate anion resulting from dissociation of the enolic group of the B ring. The electrode selectivities have been investigated.


Analytica Chimica Acta | 1991

Titrations with piezoelectric monitoring. Part 3. Redox titrations of iron(II) with dichromate and permanganate

Mo Zhi-Hong; Nie Li-Hua; Yao Shou-Zhou

A piezoelectric detector was used to determine end-points of redox titrations of iron(II) with potassium dichromate and permanganate. Iron(II) at concentrations down to 1 × 10−5 mol l−1 can be determined. Factors influencing the frequency shift-volume titration curve were investigated.

Collaboration


Dive into the Nie Li-Hua's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge