Featured researches published by Nigel J. Clarke.


Steroids | 2009

Interlaboratory comparison study of serum total testoserone measurements performed by mass spectrometry methods

Hubert W. Vesper; Shalender Bhasin; Christina Wang; Susan S. Tai; Larry A. Dodge; Ravinder J. Singh; Judie Nelson; Susan Ohorodnik; Nigel J. Clarke; Wael A. Salameh; C. Richard Parker; Raj Razdan; Elizabeth A. Monsell; Gary L. Myers

BACKGROUND Though mass spectrometry (MS) assays are increasingly used for routine clinical measurements of serum total testosterone (TT), information about the variability of results is limited. This study assessed the variability of TT measurement results from routine MS assays. METHODS Twenty serum samples (12 females, 8 males) were analyzed on 2 days by seven high performance liquid chromatography (HPLC), and one gas chromatography (GC)-tandem mass spectrometry (HPLC-MS/MS, GC-MS/MS) assays. Two samples (male and female) were provided in five replicates to assess the within-run variability. Results were compared against those obtained at National Institute of Standards and Technology (NIST). The within- and between-laboratory variability was assessed for each sample. Comparisons to the NIST results were performed using bias plot and Deming regression analysis. RESULTS The overall coefficient of variation of the results obtained with MS assays was <15%CV at >1.53 nmol/L and <34%CV at 0.3 nmol/L. The between-assay variability was the major contributor to the overall variability. The assay precision was the highest (<3%CV) with assays using liquid-liquid extraction for sample preparation or GC-MS/MS. The mean percent difference to the reference assay was 11%. The slopes of Deming regression analysis of the MS assays were between 0.903 and 1.138 (correlation coefficient: >0.996). TT concentrations for one assay were above the measurement range. CONCLUSIONS The variability of TT measurement results among MS assays is substantially smaller than that reported for immunoassays. The type of sample preparation may affect assay precision. Standardizing assays can further reduce the variability of measurement results.


Steroids | 2010

Validation of a total testosterone assay using high-turbulence liquid chromatography tandem mass spectrometry: Total and free testosterone reference ranges

Wael A. Salameh; Mildred M. Redor-Goldman; Nigel J. Clarke; Richard E. Reitz; Michael P. Caulfield

Accurate measurement of testosterone concentration is of critical importance when diagnosing and treating male hypogonadism, congenital adrenal hyperplasia, premature or delayed puberty, and androgen excess in polycystic ovary syndrome or other virilizing conditions. However, some assays have inherent limitations and biases that affect measurement of low-testosterone values. Therefore, we developed a highly specific online mass spectrometry method. Sera were extracted online using high-turbulence flow liquid chromatography coupled to analytical HPLC and atmospheric pressure chemical ionization tandem mass spectrometry (HTLC-APCI-MS/MS). Analyte ions were monitored by multiple reaction monitoring (MRM). Total analysis time was 1.15 min per sample when using the multiplexing system. Testosterone concentrations were measured directly from 150 microL of serum or plasma without derivatization or liquid-liquid extraction. The lower limit of quantification was 0.3 ng/dL, and the assay was linear up to 2000 ng/dL. The method compared very well with an established RIA: y=1.02x+1.5, r(2)=0.994. Comparison with a platform immunoassay confirmed the previously reported ICMA positive bias at low concentrations. Male and female adult and pediatric reference ranges were developed for this very sensitive and accurate high-throughput LC-MS/MS method. This method is suitable for measuring the expected low-testosterone concentrations seen in women, children, and hypogonadal males and for monitoring testosterone suppressive therapy in prostate cancer patients.


The Journal of Clinical Endocrinology and Metabolism | 2013

Serum Concentrations of 1,25-Dihydroxyvitamin D2 and 1,25-Dihydroxyvitamin D3 in Response to Vitamin D2 and Vitamin D3 Supplementation

Rachael M. Biancuzzo; Nigel J. Clarke; Richard E. Reitz; Thomas G. Travison; Michael F. Holick

OBJECTIVE The purpose of this study was to determine 1,25-dihydroxyvitamin D3 [1,25(OH)2D3] and 1,25-dihydroxyvitamin D2 [1,25(OH)2D2] levels in healthy adults consuming 1000 IU vitamin D2 or vitamin D3 per day for 11 weeks. SUBJECTS AND DESIGN Blood from 34 healthy male and female adults, aged 18 to 79 years, from a placebo-controlled, double-blind study who received a placebo, 1000 IU vitamin D3, or 1000 IU vitamin D2 daily for 11 weeks at end of winter was analyzed. Serum levels of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3, 1,25(OH)2D2, and 1,25(OH)2D3 were determined by liquid chromatography-tandem mass spectroscopy. RESULTS Of the adults, 82% were vitamin D insufficient (serum 25-hydroxyvitamin D [25(OH)D <30 ng/mL]) at the start of the study. Administration of vitamin D2 and vitamin D3 induced similar increases in total 25(OH)D as well as in 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3, respectively. Compared with placebo and adjusting for baseline levels, 1000 IU daily of vitamin D2 was associated with a mean increase of 7.4 pg/mL (95% confidence interval, 4.4-10.3) in 1,25(OH)2D2, which was accompanied by a mean decrease of 9.9 pg/mL (-15.8 to -4.0) in 1,25(OH)2D3. No such differences accompanied administration of 1000 IU daily of vitamin D3. CONCLUSION Vitamin D2 and vitamin D3 were effective in raising and maintaining total serum concentrations of 25(OH)D. Ingestion of vitamin D2 also resulted in an increase in serum concentrations of 1,25(OH)2D2. This increase was accompanied by a comparable decrease in serum concentrations of 1,25(OH)2D3; therefore, the total 1,25-dihydroxyvitamin D [1,25(OH)2D] concentrations did not significantly change after 11 weeks compared with baseline levels. Ingestion of vitamin D3 did not alter serum concentrations of 1,25(OH)2D3 or total 1,25(OH)2D. Therefore, ingestion of 1000 IU vitamin D2 or vitamin D3 for 11 weeks was effective in raising total serum concentrations of 25(OH)D as well as sustaining serum concentrations of total 1,25(OH)2D.


PLOS ONE | 2015

Temporal Relationship between Vitamin D Status and Parathyroid Hormone in the United States

Martin H. Kroll; Caixia Bi; Carl C. Garber; Harvey W. Kaufman; Dungang Liu; Anne Caston-Balderrama; Ke Zhang; Nigel J. Clarke; Minge Xie; Richard E. Reitz; Stephen C. Suffin; Michael F. Holick

Background Interpretation of parathyroid hormone (iPTH) requires knowledge of vitamin D status that is influenced by season. Objective Characterize the temporal relationship between 25-hydroxyvitamin D3 levels [25(OH)D3] and intact iPTH for several seasons, by gender and latitude in the U.S. and relate 25-hydrovitamin D2 [25(OH)D2] levels with PTH levels and total 25(OH)D levels. Method We retrospectively determined population weekly-mean concentrations of unpaired [25(OH)D2 and 25(OH)D3] and iPTH using 3.8 million laboratory results of adults. The 25(OH)D3 and iPTH distributions were normalized and the means fit with a sinusoidal function for both gender and latitudes: North >40, Central 32–40 and South <32 degrees. We analyzed PTH and total 25(OH)D separately in samples with detectable 25(OH)D2 (≥4 ng/mL). Findings Seasonal variation was observed for all genders and latitudes. 25(OH)D3 peaks occurred in September and troughs in March. iPTH levels showed an inverted pattern of peaks and troughs relative to 25(OH)D3, with a delay of 4 weeks. Vitamin D deficiency and insufficiency was common (33% <20 ng/mL; 60% <30 ng/mL) as was elevated iPTH levels (33%>65 pg/mL). The percentage of patients deficient in 25(OH)D3 seasonally varied from 21% to 48% and the percentage with elevated iPTH reciprocally varied from 28% to 38%. Patients with detectable 25(OH)D2 had higher PTH levels and 57% of the samples with a total 25(OH)D > 50 ng/mL had detectable 25(OH)D2. Interpretation 25(OH)D3 and iPTH levels vary in a sinusoidal pattern throughout the year, even in vitamin D2 treated patients; 25(OH)D3, being higher in the summer and lower in the winter months, with iPTH showing the reverse pattern. A large percentage of the tested population showed vitamin D deficiency and secondary hyperparathyroidism. These observations held across three latitudinal regions, both genders, multiple-years, and in the presence or absence of detectable 25(OH)D2, and thus are applicable for patient care.


Clinical Chemistry | 2010

Plasma renin activity by LC-MS/MS: development of a prototypical clinical assay reveals a subpopulation of human plasma samples with substantial peptidase activity.

Cory E. Bystrom; Wael A. Salameh; Richard E. Reitz; Nigel J. Clarke

BACKGROUND For management and treatment of secondary hypertension, plasma renin activity (PRA) assay is considered an essential diagnostic tool. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based approach to PRA offering improvements in laboratory workflow and throughput. During development, we observed a substantial number of clinical samples that have strong degradation activity toward angiotensin (Ang) I during generation. A preliminary characterization of this degradation activity was performed, and we provide here a method by which this degradation can be monitored via the addition of an isotope-labeled degradation standard. METHODS Automated online sample extraction coupled with HPLC was used to isolate Ang I and internal standard from plasma. The effluent from the analytical column was directed to a triple quadrupole MS operated in selected reaction monitoring mode, monitoring the a(5) and b(5) product ions from the [M+3H](+3) precursors. Routine analysis could be achieved with as little as 150 μL plasma. RESULTS We identified both C-terminal and N-terminal degradation products of Ang I using isotope-labeled peptides as controls and substrates. In 2%-5% of patient samples, the degradation essentially eliminated any Ang I produced during generation. CONCLUSIONS Our method requires reduced sample handling when compared with an RIA and eliminates the need for extended generation times for samples with low renin activity. Degradation of Ang I during generation appears to be a confounding variable in the interpretation of results from some clinical samples. Samples with profound degradation activity can be identified using a degradation standard that is added at the start of generation.


Clinical Chemistry | 2016

Recommendations for the Generation, Quantification, Storage, and Handling of Peptides Used for Mass Spectrometry-Based Assays.

Andrew N. Hoofnagle; Jeffrey R. Whiteaker; Steven A. Carr; Eric Kuhn; Tao Liu; Sam A. Massoni; Stefani N. Thomas; Reid R Townsend; Lisa J. Zimmerman; Emily S. Boja; Jing Chen; Daniel L. Crimmins; Sherri R. Davies; Yuqian Gao; Tara Hiltke; Karen A. Ketchum; Christopher R. Kinsinger; Mehdi Mesri; Matthew R. Meyer; Wei Jun Qian; Regine M. Schoenherr; Mitchell G. Scott; Tujin Shi; Gordon Whiteley; John A. Wrobel; Chaochao Wu; Brad Ackermann; Ruedi Aebersold; David R. Barnidge; David M. Bunk

BACKGROUND For many years, basic and clinical researchers have taken advantage of the analytical sensitivity and specificity afforded by mass spectrometry in the measurement of proteins. Clinical laboratories are now beginning to deploy these work flows as well. For assays that use proteolysis to generate peptides for protein quantification and characterization, synthetic stable isotope-labeled internal standard peptides are of central importance. No general recommendations are currently available surrounding the use of peptides in protein mass spectrometric assays. CONTENT The Clinical Proteomic Tumor Analysis Consortium of the National Cancer Institute has collaborated with clinical laboratorians, peptide manufacturers, metrologists, representatives of the pharmaceutical industry, and other professionals to develop a consensus set of recommendations for peptide procurement, characterization, storage, and handling, as well as approaches to the interpretation of the data generated by mass spectrometric protein assays. Additionally, the importance of carefully characterized reference materials-in particular, peptide standards for the improved concordance of amino acid analysis methods across the industry-is highlighted. The alignment of practices around the use of peptides and the transparency of sample preparation protocols should allow for the harmonization of peptide and protein quantification in research and clinical care.


Clinical Chemistry | 2013

Quantitative Insulin Analysis Using Liquid Chromatography–Tandem Mass Spectrometry in a High-Throughput Clinical Laboratory

Zhaohui Chen; Michael P. Caulfield; Michael J. McPhaul; Richard E. Reitz; Steven W. Taylor; Nigel J. Clarke

BACKGROUND Circulating insulin concentrations reflect the amount of endogenous insulin produced by the pancreas and can be monitored to check for insulin resistance. Insulin is commonly measured using immunochemiluminometric assays (ICMA). Unfortunately, differing crossreactivities of the various ICMA antibodies have led to variability in assay results. In contrast, liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based approaches can provide a highly specific alternative to immunoassays. METHODS Insulin was extracted from patient serum and reduced to liberate the insulin B chain. Subsequent resolution of the peptide was achieved by LC coupled to triple-quadrupole MS. Selected-reaction monitoring of B-chain transitions was used for quantification. Recombinant human insulin was used as a calibrator and was compared against the National Institute for Biological Standards and Control (NIBSC) reference standard. Bovine insulin and a stable isotopic-labeled ((13)C/(15)N) human insulin B chain were used and compared as internal standards. RESULTS The LC-MS/MS assay described herein has been validated according to CLIA guidelines with a limit of detection of 1.8 μIU/mL (10.8 pmol/L) and a limit of quantitation of 3 μIU/mL (18.0 pmol/L). A correlation between the LC-MS/MS assay and a US Food and Drug Administration-approved ICMA was completed for patient samples and the resulting Deming regression revealed good agreement. A reference interval for the assay was established. CONCLUSIONS A simple, high-throughput, quantitative LC-MS/MS insulin assay traceable to the NIBSC standard has been successfully developed and validated.


PLOS ONE | 2014

Simultaneous measurement of thirteen steroid hormones in women with polycystic ovary syndrome and control women using liquid chromatography-tandem mass spectrometry.

Candace C. Keefe; Mildred M. Goldman; Ke Zhang; Nigel J. Clarke; Richard E. Reitz; Corrine K. Welt

Background The measurement of adrenal and ovarian androgens in women with PCOS has been difficult based on poor specificity and sensitivity of assays in the female range. Methods Women with PCOS (NIH criteria; n = 52) and control subjects with 25–35 day menstrual cycles, no evidence of hyperandrogenism and matched for BMI (n = 42) underwent morning blood sampling. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used to simultaneously measure 13 steroids from a single blood sample to measure adrenal and ovarian steroids. Androgen and progesterone results were compared in the same samples using RIA. Results Testosterone, androstenedione, progesterone and 17OH progesterone levels were higher when measured using RIA compared to LC-MS/MS, although the testosterone RIA demonstrated the best agreement with the LC-MS/MS using a Bland-Altman analysis. Results using LC-MS/MS demonstrated that the concentration of androgens and their precursors were higher in women with PCOS than controls [median (2.5, 97.5th %ile); 1607 (638, 3085) vs. 1143 (511, 4784) ng/dL; p = 0.03]. Women with PCOS had higher testosterone [49 (16, 125) vs. 24 (10, 59) ng/dL], androstenedione [203 (98, 476) vs. 106 (69, 223) ng/dL] and 17OH progesterone levels [80 (17, 176) vs. 44 (17, 142) ng/dL] compared to controls (all P<0.02), but no differences in serum concentrations of the adrenal steroids DHEAS, cortisol, corticosterone and their 11 deoxy precursors. Women with PCOS also had an increase in the product:precursor ratio for 3β-hydroxysteroid dehydrogenase [22% (6, 92) vs. 20% (4, 43); p = 0.009]. Conclusion LC-MS/MS was superior to RIA in measuring androstenedione, progesterone and 17OH progesterone levels, while testosterone measurements were better matched in the two assays. Androgen levels were higher in women with PCOS in the absence of a difference in adrenal-predominant steroids. These data support previous findings that the ovary is an important source for the androgen excess in women with PCOS.


Journal of Investigative Medicine | 2012

A novel mass spectrometry-based assay for the accurate measurement of thyroglobulin from patient samples containing antithyroglobulin autoantibodies.

Nigel J. Clarke; Yanni Zhang; Richard E. Reitz

Thyroid cancer is the most common endocrine cancer in the United States. The primary treatment of thyroid cancer is partial or complete thyroidectomy in patients in whom the cancer is discovered preoperatively, and is often followed by radioactive iodine ablation. After the initial therapy, patients are followed up regularly, most commonly by measurement of serum thyroglobulin (Tg) levels and high-resolution neck ultrasound. As Tg is only produced within the thyroid gland, it has long been recognized as an excellent biomarker for the presence of residual disease after treatment. A number of immunoassays are in common use to measure serum Tg levels. Unfortunately, irrespective of which method is chosen, there is a major potential artifact, in that the presence of autoantibodies binding to Tg (ATG) may bias the results to the point where they are clinically unreliable. This article describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the measurement of serum Tg after tryptic digestion of serum samples. The method is compared to Tg analyses using both a Food and Drug Administration–approved immunometric assay (IMA) and a well-respected, clinically used radioimmunoassay. In the absence of ATG, the new LC-MS/MS assay demonstrates equivalency compared to the IMA. However, in ATG-positive patients, the IMA Tg results are lower than the LC-MS/MS assay and the radioimmunoassay Tg results are typically higher. These studies demonstrate the accuracy and validity of the measurement of Tg by LC-MS/MS. This assay will permit the accurate determination of Tg levels even in patients with ATG.


PLOS ONE | 2012

Clinical Utility of Insulin-Like Growth Factor 1 and 2; Determination by High Resolution Mass Spectrometry

Cory E. Bystrom; Shijun Sheng; Ke Zhang; Michael T. Caulfield; Nigel J. Clarke; Richard E. Reitz

Measurement of insulin-like growth factor-1 (IGF-I) has utility for the diagnosis and management of growth disorders, but inter-assay comparison of results has been complicated by a multitude of reference standards, antibodies, detection methods, and pre-analytical preparation strategies. We developed a quantitative LC-MS method for intact IGF-I, which has advantages in throughput and complexity when compared to mass spectrometric approaches that rely on stable isotope dilution analysis of tryptic peptides. Since the method makes use of full-scan data, the assay was easily extended to provide quantitative measurement of IGF-II using the same assay protocol. The validated LC-MS assay for IGF-I and IGF-II provides accurate results across the pediatric and adult reference range and is suitable for clinical use.

Collaboration


Dive into the Nigel J. Clarke's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Frank Z. Stanczyk

University of Southern California

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge