Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Niko Moritz is active.

Publication


Featured researches published by Niko Moritz.


Acta Orthopaedica | 2012

Low BMD affects initial stability and delays stem osseointegration in cementless total hip arthroplasty in women: a 2-year RSA study of 39 patients.

Hannu T. Aro; Jessica J. Alm; Niko Moritz; Tatu J. Mäkinen; Petteri Lankinen

Background and purpose Immediate implant stability is a key factor for success in cementless total hip arthroplasty (THA). Low bone mineral density (BMD) and age-related geometric changes of the proximal femur may jeopardize initial stability and osseointegration. We compared migration of hydroxyapatite-coated femoral stems in women with or without low systemic BMD. Patients and methods 61 female patients with hip osteoarthritis were treated with cementless THA with anatomically designed hydroxyapatite-coated femoral stems and ceramic-ceramic bearing surfaces (ABG-II). Of the 39 eligible patients between the ages of 41 and 78 years, 12 had normal systemic BMD and 27 had osteopenia or osteoporosis. According to the Dorr classification, 21 had type A bone and 18 had type B. Translational and rotational migration of the stems was evaluated with radiostereometric analysis (RSA) up to 2 years after surgery. Results Patients with low systemic BMD showed higher subsidence of the femoral stem during the first 3 months after surgery than did those with normal BMD (difference = 0.6, 95% CI: 0.1–1.1; p = 0.03). Low systemic BMD (odds ratio (OR) = 0.1, CI: 0.006–1.0; p = 0.02), low local hip BMD (OR = 0.3, CI: 0.1–0.7; p = 0.005) and ageing (OR = 1.1, CI: 1.0–1.2; p = 0.02) were risk factors for delayed translational stability. Ageing and low canal flare index were risk factors for delayed rotational stabilization (OR = 3, CI: 1.1–9; p = 0.04 and OR = 1.1, CI: 1.0–1.2; p = 0.02, respectively). Harris hip score and WOMAC score were similar in patients with normal systemic BMD and low systemic BMD. Interpretation Low BMD, changes in intraosseous dimensions of the proximal femur, and ageing adversely affected initial stability and delayed osseointegration of cementless stems in women.


Medical Engineering & Physics | 2009

Development of a multi-component fiber-reinforced composite implant for load-sharing conditions

D.S. Zhao; Niko Moritz; P. Laurila; Riina Mattila; Lippo V.J. Lassila; Niko Strandberg; T. Mäntylä; Pekka K. Vallittu; Hannu T. Aro

Fiber-reinforced composites (FRC) have the potential for use as load-bearing orthopaedic implants if the high strength and elastic modulus of FRC implant can be matched with local requirements. This study tested the in vivo performance of novel FRC implants made of unidirectional glass fibers (E-glass fibers in Bis-GMA and TEGDMA polymeric matrix). The implant surface was covered with bioactive glass granules. Control implants were made of surface-roughened titanium. Stress-shielding effects of the implants were predicted by finite element modelling (FEM). Surgical stabilization of bone metastasis in the subtrochanteric region of the femur was simulated in 12 rabbits. An oblong subtrochanteric defect of a standardized size (reducing the torsional strength of the bones approximately by 66%) was created and an intramedullary implant made of titanium or the FRC composite was inserted. The contralateral femur served as the intact control. At 12 weeks of healing, the femurs were harvested and analyzed by radiography, torsional testing, micro-CT imaging and hard tissue histology. The functional recovery was unremarkable in both groups, although the final analysis revealed two healed undisplaced peri-implant fractures in the group of FRC implants. FEM studies demonstrated differences in stress-shielding effects of the titanium and FRC implants, but the expected biological consequences did not become evident during the follow-up time of the animal study. Biomechanical testing of the retrieved femurs showed no significant differences between the groups. The torsional strength of the fixed bones had returned the level of contralateral intact femurs. Both implants showed ongrowth of intramedullary new bone. No adverse tissue reactions were observed. Based on these favorable results, a large-scale EU-project (NewBone, www.hb.se/ih/polymer/newbone) has been launched for development of orthopaedic FRC implants.


Acta Biomaterialia | 2013

Biological responses of silver-coated thermosets: An in vitro and in vivo study

Eleonora Marsich; Andrea Travan; Ivan Donati; Gianluca Turco; Julia Kulkova; Niko Moritz; Hannu T. Aro; Matteo Crosera; Sergio Paoletti

Bisphenol A glycidylmethacrylate (BisGMA)/triethyleneglycol dimethacrylate (TEGDMA) thermosets are biomaterials commonly employed for orthopedic and dental applications; for both these fields, bacterial adhesion to the surface of the implant represents a major issue for the outcome of the surgical procedures. In this study, the antimicrobial properties of a nanocomposite coating formed by polysaccharide 1-deoxylactit-1-yl chitosan (Chitlac) and silver nanoparticles (nAg) on methacrylate thermosets were studied. The Chitlac-nAg system showed good anti-bacterial and anti-biofilm activity although its biocidal properties can be moderately, albeit significantly, inhibited by serum proteins. In vitro studies on the silver release kinetic in physiological conditions showed a steady metal release associated with a gradual loss of antimicrobial activity. However, after 3weeks there was still effective protection against bacterial colonization which could be accounted for by the residual silver. This time-span could be considered adequate to confer short-term protection from early peri-implant infections. Preliminary in vivo tests in a mini-pig animal model showed good biological compatibility of Chitlac-nAg-coated materials when implanted in bony tissue. The comparison was made with implants of titanium Ti6Al4V alloy and with a Chitlac-coated thermoset. Bone healing patterns and biocompatibility parameters observed for nAg-treated material were comparable with those observed for control implants.


Acta Orthopaedica | 2009

Female patients with low systemic BMD are prone to bone loss in Gruen zone 7 after cementless total hip arthroplasty

Jessica J. Alm; Tatu J. Mäkinen; Petteri Lankinen; Niko Moritz; Tero Vahlberg; Hannu T. Aro

Background and purpose Factors that lead to periprosthetic bone loss following total hip arthroplasty (THA) may not only depend on biomechanical implant-related factors, but also on various patient-related factors. We investigated the association between early changes in periprosthetic bone mineral density (BMD) and patient-related factors. Patients and methods 39 female patients underwent cementless THA (ABG II) with ceramic-ceramic bearing surfaces. Periprosthetic BMD in the proximal femur was determined with DXA after surgery and at 3, 6, 12, and 24 months. 27 patient-related factors were analyzed for their value in prediction of periprosthetic bone loss. Results Total periprosthetic BMD was temporarily reduced by 3.7% at 3 months (p < 0.001), by 3.8% at 6 months (p < 0.01), and by 2.6% at 12 months (p < 0.01), but recovered thereafter up to 24 months. Preoperative systemic osteopenia and osteoporosis, but not the local BMD of the operated hip, was predictive of bone loss in Gruen zone 7 (p = 0.04), which was the only region with a statistically significant decrease in BMD (23%, p < 0.001) at 24 months. Preoperative serum markers of bone turnover predicted the early temporary changes of periprosthetic BMD. The other patient-related factors failed to show any association with the periprosthetic BMD changes. Interpretation Female patients with low systemic BMD show greater bone loss in Gruen zone 7 after cementless THA than patients with normal BMD. Systemic DXA screening for osteoporosis in postmenopausal patients before THA could be used to identify patients in need of prophylactic anti-resorptive therapy.


Biomacromolecules | 2012

Polysaccharide-coated thermosets for orthopedic applications: from material characterization to in vivo tests.

Andrea Travan; Eleonora Marsich; Ivan Donati; Marie-Pierre Foulc; Niko Moritz; Hannu T. Aro; Sergio Paoletti

The long-term stability and success of orthopedic implants depend on the osseointegration process, which is strongly influenced by the biomaterial surface. A promising approach to enhance implant integration involves the modification of the surface of the implant by means of polymers that mimic the natural components of the extracellular matrix, for example, polysaccharides. In this study, methacrylate thermosets (bisphenol A glycidylmethacrylate/triethyleneglycol dimethacrylate), a widely used composition for orthopedic and dental applications, have been coated by electrostatic deposition of a bioactive chitosan-derivative. This polysaccharide was shown to induce osteoblasts aggregation in vitro, to stimulate cell proliferation and to enhance alkaline phosphatase activity. The coating deposition was studied by analyzing the effect of pH and ionic strength on the grafting of the polysaccharide. Contact angle studies show that the functionalized material displays a higher hydrophilic character owing to the increase of surface polar groups. The mechanical properties of the coating were evaluated by nanoindentation studies which point to higher values of indentation hardness and modulus (E) of the polysaccharide surface layer, while the influence of cyclic stress on the construct was assessed by fatigue tests. Finally, in vivo tests in minipigs showed that the polysaccharide-based implant showed a good biocompatibility and an ability for osseointegration at least similar to that of the titanium Ti6Al4V alloy with roughened surface.


Journal of Materials Science: Materials in Medicine | 2004

Characterisation of bioactive glass coatings on titanium substrates produced using a CO2 laser.

Niko Moritz; E. Vedel; Heimo Ylänen; M. Jokinen; Mikko Hupa; Antti Yli-Urpo

Titanium and its alloys are widely used in load-bearing bioinert implants. Bioactive glasses (BAGs) form a chemical bond with bone, but they are not suitable for load-bearing applications. Creating a BAG coating on a titanium implant could combine the best properties of both materials. The results tend to be poor when conventional firing methods are applied to coat titanium with BAG. A local application of heat to melt the glass can be achieved by a CO2 laser. A new method is introduced to create BAG coatings on titanium locally in a controlled manner, with a focused CO2 laser beam. The coatings produced by this method precipitate calcium phosphate in vitro. Processing parameters (number of coated layers, laser power, and processing atmosphere) providing a firm attachment of the glass and good in vitro bioactivity were identified. XRD analysis showed no crystallisation of the glass due to processing with the laser. EDXA indicated the formation of a calcium phosphate layer, which FTIR suggested to be a hydroxyapatite. The results show CO2 laser processing to be a promising technique for the manufacture of 30–40 μm BAG coatings on titanium.


Acta Biomaterialia | 2008

Mechanical verification of soft-tissue attachment on bioactive glasses and titanium implants

Desheng Zhao; Niko Moritz; Erik Vedel; Leena Hupa; Hannu T. Aro

Soft-tissue attachment is a desired feature of many clinical biomaterials. The aim of the current study was to design a suitable experimental method for tensile testing of implant incorporation with soft-tissues. Conical implants were made of three compositions of bioactive glass (SiO(2)-P(2)O(5)-B(2)O(3)-Na(2)O-K(2)O-CaO-MgO) or titanium fiber mesh (porosity 84.7%). The implants were surgically inserted into the dorsal subcutaneous soft-tissue or back muscles in the rat. Soft-tissue attachment was evaluated by pull-out testing using a custom-made jig 8 weeks after implantation. Titanium fiber mesh implants had developed a relatively high pull-out force in subcutaneous tissue (12.33+/-5.29 N, mean+/-SD) and also measurable attachment with muscle tissue (2.46+/-1.33 N). The bioactive glass implants failed to show mechanically relevant soft-tissue bonding. The experimental set-up of mechanical testing seems to be feasible for verification studies of soft-tissue attachment. The inexpensive small animal model is beneficial for large-scale in vivo screening of new biomaterials.


Journal of Biomechanics | 2011

Quality of intertrochanteric cancellous bone as predictor of femoral stem RSA migration in cementless total hip arthroplasty

Niko Moritz; Jessica J. Alm; Petteri Lankinen; Tatu J. Mäkinen; Kimmo Mattila; Hannu T. Aro

In cementless total hip arthroplasty, osteoporosis may jeopardize the achievement of immediate stability and lead to migration of anatomically shaped femoral stems. Poor quality of proximal cancellous bone per se may also affect the rate of osseointegration. In a selected group of female total hip arthroplasty patients (mean age 64 years) with unremarkable medical history, intertrochanteric cancellous bone biopsy was taken from the site of stem implantation. Local bone quality, determined by structural μCT imaging and destructive compression testing of the biopsy tissue, was used as the predictor of three-dimensional stem migration determined by radiostereometric analysis (RSA) up to 24 months. The patients exhibited major differences in mechanical properties of the intertrochanteric cancellous bone, which were closely related to the structural parameters calculated from μCT data. Unexpectedly, the major differences observed in the quality of trochanteric cancellous bone had only minor reflections in the RSA migration of the femoral stems. In statistical analysis, the μCT-based bone mineral density quartile (low, middle, high) was the only significant predictor for stem translation at 24 months (p=0.022) but only a small portion (R(2)=0.16) of the difference in translation could be explained by changes in bone mineral density quartile. None of the other parameters investigated predicted stem migration in translation or rotation. In conclusion, poor quality of intertrochanteric cancellous bone seems to contribute to the risk of implant migration less than expected. Probably also the importance of surgical preservation of intertrochanteric cancellous bone has been over-emphasized for osseointegration of cementless stem.


Dental Materials | 2012

Multi-layer porous fiber-reinforced composites for implants: In vitro calcium phosphate formation in the presence of bioactive glass

Sara Nganga; Di Zhang; Niko Moritz; Pekka K. Vallittu; Leena Hupa

OBJECTIVES Glass-fiber-reinforced composites (FRCs), based on bifunctional methacrylate resin, have recently shown their potential for use as durable cranioplasty, orthopedic and oral implants. In this study we suggest a multi-component sandwich implant structure with (i) outer layers out of porous FRC, which interface the cortical bone, and (ii) inner layers encompassing bioactive glass granules, which interface with the cancellous bone. METHODS The capability of Bioglass(®) 45S5 granules (100-250μm) to induce calcium phosphate formation on the surface of the FRC was explored by immersing the porous FRC-Bioglass laminates in simulated body fluid (SBF) for up to 28d. RESULTS In both static (agitated) and dynamic conditions, bioactive glass granules induced precipitation of calcium phosphate at the laminate surfaces as confirmed by scanning electron microscopy. SIGNIFICANCE The proposed dynamic flow system is useful for the in vitro simulation of bone-like apatite formation on various new porous implant designs containing bioactive glass and implant material degradation.


Journal of Orthopaedic Research | 2012

Comparison of the osteogenic capacity of minipig and human bone marrow-derived mesenchymal stem cells

Terhi J. Heino; Jessica J. Alm; Niko Moritz; Hannu T. Aro

Minipigs are a recommended large animal model for preclinical testing of human orthopedic implants. Mesenchymal stem cells (MSCs) are the key repair cells in bone healing and implant osseointegration, but the osteogenic capacity of minipig MSCs is incompletely known. The aim of this study was to isolate and characterize minipig bone marrow (BM) and peripheral blood (PB) MSCs in comparison to human BM‐MSCs. BM sample was aspirated from posterior iliac crest of five male Göttingen minipigs (age 15 ± 1 months). PB sample was drawn for isolation of circulating MSCs. MSCs were selected by plastic‐adherence as originally described by Friedenstein. Cell morphology, colony formation, proliferation, surface marker expression, and differentiation were examined. Human BM‐MSCs were isolated and cultured from adult fracture patients (n = 13, age 19–60 years) using identical techniques. MSCs were found in all minipig BM samples, but no circulating MSCs could be detected. Minipig BM‐MSCs had similar morphology, proliferation, and colony formation capacities as human BM‐MSCs. Unexpectedly, minipig BM‐MSCs had a significantly lower ability than human BM‐MSCs to form differentiated and functional osteoblasts. This observation emphasizes the need for species‐specific optimization of MSC culture protocol before direct systematic comparison of MSCs between human and various preclinical large animal models can be made.

Collaboration


Dive into the Niko Moritz's collaboration.

Top Co-Authors

Avatar

Hannu T. Aro

Turku University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mika Jokinen

Åbo Akademi University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rami Madanat

Helsinki University Central Hospital

View shared research outputs
Top Co-Authors

Avatar

Erik Vedel

Åbo Akademi University

View shared research outputs
Researchain Logo
Decentralizing Knowledge