Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Nikola A. Baumann is active.

Publication


Featured researches published by Nikola A. Baumann.


Clinical Journal of The American Society of Nephrology | 2011

Relative Performance of the MDRD and CKD-EPI Equations for Estimating Glomerular Filtration Rate among Patients with Varied Clinical Presentations

Kazunori Murata; Nikola A. Baumann; Amy K. Saenger; Timothy S. Larson; Andrew D. Rule; John C. Lieske

BACKGROUND The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation was developed using both CKD and non-CKD patients to potentially replace the Modification of Diet in Renal Disease (MDRD) equation that was derived with only CKD patients. The objective of our study was to compare the accuracy of the MDRD and CKD-EPI equations for estimating GFR in a large group of patients having GFR measurements for diverse clinical indications. DESIGN, SETTING, PARTICIPANTS, AND MEASUREMENTS A cross-sectional study was conducted of patients who underwent renal function assessment for clinical purposes by simultaneous measurements of serum creatinine and estimation of GFR using the MDRD and CKD-EPI equations and renal clearance of iothalamate (n = 5238). RESULTS Bias compared with measured GFR (mGFR) varied for each equation depending on clinical presentation. The CKD-EPI equation demonstrated less bias than the MDRD equation in potential kidney donors (-8% versus -18%) and postnephrectomy donors (-7% versus -15%). However, the CKD-EPI equation was slightly more biased than the MDRD equation in native CKD patients (6% versus 3%), kidney recipients (8% versus 1%), and other organ recipients (9% versus 3%). Among potential kidney donors, the CKD-EPI equation had higher specificity than the MDRD equation for detecting an mGFR <60 ml/min per 1.73 m(2) (98% versus 94%) but lower sensitivity (50% versus 70%). CONCLUSIONS Clinical presentation influences the estimation of GFR from serum creatinine, and neither the CKD-EPI nor MDRD equation account for this. Use of the CKD-EPI equation misclassifies fewer low-risk patients as having reduced mGFR, although it is also less sensitive for detecting mGFR below specific threshold values used to define CKD stages.


Journal of Assisted Reproduction and Genetics | 2014

Composition of protein supplements used for human embryo culture

Dean E. Morbeck; Melissa Paczkowski; J.R. Fredrickson; Rebecca L. Krisher; Heather S. Hoff; Nikola A. Baumann; Thomas P. Moyer; Dietrich Matern

PurposeTo determine the composition of commercially available protein supplements for embryo culture media and test if differences in protein supplement composition are biologically relevant in a murine model.MethodsAmino acid, organic acid, ion and metal content were determined for 6 protein supplements: recombinant human albumin (AlbIX), human serum albumin (HSA and Buminate), and three complex protein supplements (SSS, SPS, LGPS). To determine if differences in the composition of these supplements are biologically relevant, mouse one-cell embryos were collected and cultured for 120 hours in each protein supplement in Global media at 5 and 20 % oxygen in an EmbryoScope time-lapse incubator. The compositions of six protein supplements were analyzed for concentrations of 39 individual amino acids, organic acids, ions and elements. Blastocyst development and cell cycle timings were calculated at 96-hours of culture and the experiments were repeated in triplicate. Blastocyst gene expression was analyzed.ResultsRecombinant albumin had the fewest undefined components , the lowest concentration of elements detected, and resulted in high blastocyst development in both 5 and 20 % oxygen. Buminate, LGPS and SPS had high levels of transition metals whereas SSS had high concentrations of amino acids. Pre-compaction mouse embryo development was delayed relative to embryos in AlbIX for all supplements and blastocyst formation was reduced in Buminate, SPS and SSS.ConclusionsThe composition of protein supplements are variable, consisting of previously undescribed components. High concentrations of pro-oxidant transition metals were most notable. Blastocyst development was protein dependent and showed an interaction with oxygen concentration and pro-oxidant supplements.


The Journal of Urology | 2013

Personalized Prostate Specific Antigen Testing Using Genetic Variants May Reduce Unnecessary Prostate Biopsies

Brian T. Helfand; Stacy Loeb; Qiaoyan Hu; Phillip R. Cooper; Kimberly A. Roehl; Barry B. McGuire; Nikola A. Baumann; William J. Catalona

PURPOSE Recent studies have identified genetic variants associated with increased serum prostate specific antigen concentrations and prostate cancer risk, raising the possibility of diagnostic bias. By correcting for the effects of these variants on prostate specific antigen, it may be possible to create a personalized prostate specific antigen cutoff to more accurately identify individuals for whom biopsy is recommended. Therefore, we determined how many men would continue to meet common biopsy criteria after genetic correction of their measured prostate specific antigen concentrations. MATERIALS AND METHODS The genotypes of 4 single nucleotide polymorphisms previously associated with serum prostate specific antigen levels (rs2736098, rs10788160, rs11067228 and rs17632542) were determined in 964 healthy Caucasian volunteers without prostate cancer. Genetic correction of prostate specific antigen was performed by dividing an individuals prostate specific antigen value by his combined genetic risk. Analyses were used to compare the percentage of men who would meet commonly used biopsy thresholds (2.5 ng/ml or greater, or 4.0 ng/ml or greater) before and after genetic correction. RESULTS Genetic correction of serum prostate specific antigen results was associated with a significantly decreased percentage of men meeting biopsy thresholds. Genetic correction could lead to a 15% or 20% relative reduction in the total number of biopsies using a biopsy threshold of 2.5 ng/ml or greater, or 4.0 ng/ml or greater, respectively. In addition, genetic correction could result in an 18% to 22% reduction in the number of potentially unnecessary biopsies and a 3% decrease in potentially delayed diagnoses. CONCLUSIONS Our results suggest that 4 single nucleotide polymorphisms can be used to adjust a mans measured prostate specific antigen concentration and potentially delay or prevent unnecessary prostate biopsies in Caucasian men.


Clinical Chemistry | 2015

Performance of Cystatin C– and Creatinine-Based Estimated Glomerular Filtration Rate Equations Depends on Patient Characteristics

Jeffrey W. Meeusen; Andrew D. Rule; Nikolay Voskoboev; Nikola A. Baumann; John C. Lieske

BACKGROUND The Kidney Disease Improving Global Outcomes (KDIGO) guideline recommends use of a cystatin C-based estimated glomerular filtration rate (eGFR) to confirm creatinine-based eGFR between 45 and 59 mL · min(-1) · (1.73 m(2))(-1). Prior studies have demonstrated that comorbidities such as solid-organ transplant strongly influence the relationship between measured GFR, creatinine, and cystatin C. Our objective was to evaluate the performance of cystatin C-based eGFR equations compared with creatinine-based eGFR and measured GFR across different clinical presentations. METHODS We compared the performance of the CKD-EPI 2009 creatinine-based estimated GFR equation (eGFRCr) and the newer CKD-EPI 2012 cystatin C-based equations (eGFRCys and eGFRCr-Cys) with measured GFR (iothalamate renal clearance) across defined patient populations. Patients (n = 1652) were categorized as transplant recipients (n = 568 kidney; n = 319 other organ), known chronic kidney disease (CKD) patients (n = 618), or potential kidney donors (n = 147). RESULTS eGFRCr-Cys showed the most consistent performance across different clinical populations. Among potential kidney donors without CKD [stage 2 or higher; eGFR >60 mL · min(-1) · (1.73 m(2))(-1)], eGFRCys and eGFRCr-Cys demonstrated significantly less bias than eGFRCr; however, all 3 equations substantially underestimated GFR when eGFR was <60 mL · min(-1) · (1.73 m(2))(-1). Among transplant recipients with CKD stage 3B or greater [eGFR <45 mL · min(-1) · (1.73 m(2))(-1)], eGFRCys was significantly more biased than eGFRCr. No clear differences in eGFR bias between equations were observed among known CKD patients regardless of eGFR range or in any patient group with a GFR between 45 and 59 mL · min(-1) · (1.73 m(2))(-1). CONCLUSIONS The performance of eGFR equations depends on patient characteristics that are readily apparent on presentation. Among the 3 CKD-EPI equations, eGFRCr-Cys performed most consistently across the studied patient populations.


Clinical Chemistry and Laboratory Medicine | 2013

Utility of a panel of sera for the alignment of test results in the worldwide multicenter study on reference values

Kiyoshi Ichihara; Yesim Ozarda; George G. Klee; Joely A. Straseski; Nikola A. Baumann; Kiyohide Ishikura

Abstract Background: In a planned International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) worldwide study on reference intervals (RIs), a common panel of serum samples is to be measured by laboratories from different countries, and test results are to be compared through conversion using linear regression analysis. This report presents a validation study that was conducted in collaboration with four laboratories. Methods: A panel composed of 80 sera was prepared from healthy individuals, and 45 commonly tested analytes (general chemistry, tumor markers, and hormones) were measured on two occasions 1 week apart in each laboratory. Reduced major-axis linear regression was used to convert reference limits (LL and UL). Precision was expressed as a ratio of the standard error of converted LL or UL to the standard deviation (SD) comprising RI (approx. 1/4 of the RI width corresponding to between-individual SD). The allowable and optimal levels of error for the SD ratio (SDR) were set as ≤0.250 and ≤0.125, respectively, in analogy to the common method of setting limits for analytical bias based on between-individual SD. Results: The values for the calculated SDRs depended upon the distribution patterns of test results: skewness toward higher values makes SDRLL lower and SDRUL higher. However, the CV of the regression line slope, CV(b), is less affected by skewness. The average of SDRLL and SDRUL (aveSDR) correlates closely with CV(b) (r=0.995). The aveSDRs of ≤0.25 and ≤0.125 corresponds approximately to CV(b) values of ≤11% and ≤5.5%, respectively. For all results (i.e., n=80), conversion was allowable (optimal) in 98% (89%) of the analytes, as judged by CV(b). Resampling studies using random subsets of data with a data size (n) of 70 to 20 revealed that SDRs and CV(b) gradually increase with reduction of n, especially with n ≤30. Conclusions: CV(b) is a robust estimator for judging the convertibility of reference values among laboratories, even with a skewed distribution. Assuming 40 sera to be a practical size for the panel, reference values of 89% (80%) of analytes examined were made comparable by regression analysis with the allowable (optimal) level of precision.


Seminars in Thrombosis and Hemostasis | 2013

Local verification and assignment of mean normal prothrombin time and International Sensitivity Index values across various instruments: recent experience and outcome from North America.

Julie I. Tange; Diane E. Grill; Christopher D. Koch; Roxanne J. Ybabez; Benjamin J. Krekelberg; Kara A. Fylling; Cynthia R. Wiese; Nikola A. Baumann; Darci R. Block; Brad S. Karon; Dong Chen; Rajiv K. Pruthi

Warfarin dosing relies on accurate measurements of international normalized ratio (INR), which is calculated from the prothrombin time (PT), International Sensitivity Index international sensitivity index (ISI) of the thromboplastin, and the geometric mean of normal PT (MNPT). However, ISI assignments of certain reagent/instrument combinations are frequently unavailable, especially when the reagent and instrument are not from the same manufacturer. The effort to be in compliance with widely endorsed Clinical and Laboratory Standards Institute (CLSI) guidelines by locally verifying or assigning an ISI to an unsupported reagent/instrument combination is further hindered by the lack of US Food and Drug Administration (FDA)-approved certified plasmas designated for a particular reagent/instrument combination. The objectives of the study include development of a process to verify/assign ISI and MNPT of a single thromboplastin reagent from one manufacturer across multiple instruments including several from another manufacturer and across several campuses of a single institution, the Mayo Clinic. In this study, RecombiPlasTin 2G (R2G), was evaluated on the ACL TOP 700 (IL), STA-R Evolution, STA Compact, and STA Satellite. Random normal donor samples (n = 25) were used to verify/assign MNPT. A subset of the normal donors (n = 8) and 13 warfarin pools (INR range: 1.3-3.9), created from stable warfarin patient plasma, were used for ISI verification/assignment. The manufacturers assigned ISI was first verified on the ACL TOP 700 (reference method), then assigned on three unsupported instruments using orthogonal regression analysis. The MNPT and manufacturer assigned ISI (11.0, 0.95) were verified on the ACL TOP 700 and subsequently assigned on the STA-R Evolution (11.6, 1.04); STA Compact (11.5, 1.02); and STA Satellite (10.9, 0.99). Linear correlations of the INR results from all the four instruments demonstrated an r2 > 0.99. This process provides a reproducible approach to assigning ISIs on unsupported reagent/instrument combinations. Our data also confirm that ISIs of the same PT reagent differ significantly on different instruments, thus confirming the requirement for evaluations and validation of ISIs for different reagent/instrument combinations.


Clinical Chemistry | 2016

Implementation of Clinical Decision Support Rules to Reduce Repeat Measurement of Serum Ionized Calcium, Serum Magnesium, and N-Terminal Pro-B-Type Natriuretic Peptide in Intensive Care Unit Inpatients

Ann M. Moyer; Amy K. Saenger; Maria Alice V. Willrich; Leslie J. Donato; Nikola A. Baumann; Darci R. Block; Chad M. Botz; Munawwar A. Khan; Allan S. Jaffe; Curtis A. Hanson; Brad S. Karon

BACKGROUND We assessed the impact of clinical decision support (CDS) rules within the electronic health record for ionized calcium (iCa), serum magnesium (Mg), and N-terminal pro-B-type natriuretic peptide (NT-proBNP) in intensive care unit (ICU) inpatients at a large academic center. METHODS A repeat order for measurement of iCa or Mg placed within 24 (iCa) or 48 (Mg) h of a previously nonactionable result, or additional orders for NT-proBNP beyond 1 within a single hospitalization, triggered a CDS pop-up alert showing the prior result and offering the opportunity to cancel the order or to place the order after entering an indication for repeat testing. The number of tests performed for each of these analytes and incidence of adverse clinical outcomes potentially associated with hypocalcemia or hypomagnesemia were compared between the 90-day period before CDS implementation and two 90-day periods immediately following. RESULTS iCa test volumes decreased by 48%, Mg by 39%, and NT-proBNP by 28% in the 90-day period immediately following implementation and remained decreased by 54%, 49%, and 22%, respectively, during the following 90-day period (all P values <0.0002). Adverse clinical outcomes potentially associated with hypocalcemia or hypomagnesemia did not increase (all P-values >0.17). CONCLUSIONS Implementation of CDS dramatically decreased repeat testing of iCa, Mg, and NT-proBNP without adversely impacting clinical outcomes in the ICU. Expansion of the rules from the ICU units to include the entire hospitalized patient population and expansion to additional analytes is expected to lead to further reductions in testing.


Clinical and translational gastroenterology | 2015

Pancreatic Juice Prostaglandin E2 Concentrations Are Elevated in Chronic Pancreatitis and Improve Detection of Early Disease

Barham K. Abu Dayyeh; Darwin L. Conwell; Navtej Buttar; Vivek Kadilaya; P. Hart; Nikola A. Baumann; Benjamin L. Bick; Suresh T. Chari; Sonia Chowdhary; Jonathan E. Clain; Ferga C. Gleeson; Linda S. Lee; Michael J. Levy; Randall K. Pearson; Bret T. Petersen; Elizabeth Rajan; Hanno Steen; Shadeah Suleiman; Peter A. Banks; Santhi Swaroop Vege; Mark Topazian

Objectives:Chronic pancreatitis (CP) may be difficult to diagnose in early stages. We aimed to measure pancreatic juice (PJ) prostaglandin E2 (PGE2) concentrations to determine whether they are elevated in CP and improve diagnosis of early disease.Methods:We measured PJ PGE2 in 10 patients with established CP, 25 patients who met criteria for “minimal change” chronic pancreatitis (MCCP), and 10 normal control participants.Results:Median PJ PGE2 was elevated in CP (307 pg/ml, IQR (249–362)) and MCCP (568 pg/ml, (418–854)) compared with normal controls (104 pg/ml, (68–206)) (P≤ 0.001). Area under receiving operator curve (AUROC) for diagnosis of CP and MCCP was 0.9 and 0.62, respectively, for PJ bicarbonate concentration alone; AUROC was 1.0 and 0.94 for the combination of PJ bicarbonate and PGE2 concentrations.Conclusions:PJ PGE2 appears to be a biomarker for CP and is elevated in both established and “minimal change” chronic pancreatitis.


Clinical Biochemistry | 2014

Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals.

Neval Akbas; Patricia G. Schryver; Alicia Algeciras-Schimnich; Nikola A. Baumann; Darci R. Block; Jeffrey R. Budd; S.J. Stephen Gaston; George G. Klee

OBJECTIVES We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). METHODS Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. RESULTS All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. CONCLUSIONS The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits.


Clinical Chemistry | 2012

A Case of Floating Gel

Erin J. Kaleta; Allan S. Jaffe; Nikola A. Baumann; Darci R. Block

Two unrelated patients underwent coronary angiography and a percutaneous intervention. At the end of the procedures, blood was collected (Vacutainer® SST™; BD) for troponin, creatine kinase (CK), and CK-MB isoenzyme analysis. After centrifugation with the Roche Modular Pre-Analytics system (Roche Diagnostics), pipetting error alerts were triggered on the aliquoting module of the Pre-Analytics system. Investigation revealed that the separator gel had migrated above the serum (Fig. 1A), preventing separation of the serum from the …

Collaboration


Dive into the Nikola A. Baumann's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge