Nikolay Mudrov
Bulgarian Academy of Sciences
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Nikolay Mudrov.
Physiological Measurement | 2006
Vessela Krasteva; Mikhail Matveev; Nikolay Mudrov; Rada Prokopova
External defibrillation requires the application of high voltage electrical impulses via large external electrodes, placed on selected locations on the thorax surface. The position of the electrodes is one of the major determinants of the transthoracic impedance (TTI) which influences the intracardiac current flow during electric shock and defibrillation success. The variety of factors which influence TTI measurements raised our interest to investigate the range of TTI values and the temporal TTI variance during long-term application of defibrillation self-adhesive electrodes in two conventional positions on the patients chest--position 1 (sub-clavicular/sub-axillar position) and position 2 (antero-posterior position). The prospective study included 86 randomly selected volunteers (39 male and 49 female, 67 patients with normal skin, 13 patients with dry skin and 6 patients with greasy skin, 16 patients with chest pilosity and 70 patients without chest pilosity). The TTI was measured according to the interelectrode voltage drop obtained by passage of a low-amplitude high-frequency current (32 kHz) between the two self-adhesive electrodes (active area about 92 cm2). For each patient, the TTI values were measured within 10 s, 1 min and 5 min after sticking the electrodes to the skin surface, independently for the two tested electrode positions. We found that the expected TTI range is between 58 Omega and 152 Omega for position 1 and between 55 Omega and 149 Omega for position 2. Although the two TTI ranges are comparable, we measured significantly higher TTI mean of about (107.2 +/- 22.3) Omega for position 1 compared to (96.6 +/- 19.2) Omega for position 2 (p = 0.001). This fact suggested that the antero-posterior position of the electrodes is favourable for defibrillation. Within the investigated time interval of 5 min, we observed a significant TTI reduction with about 6.9% (7.4 Omega/107.2 Omega) for position 1 and about 5.3% (5.1 Omega/96.6 Omega) for position 2. We suppose that the long-term application of self-adhesive electrodes would lead to improvement of the physical conditions for conduction of the defibrillation current and to diminution of energy loss in the electrode-skin contact impedance. We found that gender is important when position 1 is used because women have significantly higher TTI (111 +/- 20.3) Omega compared to the TTI of men (102.6 +/- 24) Omega (p = 0.0442). Although we found some specifics of the electrode-skin contact layer, we can conclude that because of the insignificant differences in TTI, the operator of the defibrillator paddles does not need to take into consideration the skin type and pilosity of the patients. Analysis of the correlations between TTI and the individual patient characteristics (chest size, weight, height, age) showed that these patient characteristics are unreliable factors for prediction of the TTI values and optimal defibrillation pulse parameters and energy.
Medical & Biological Engineering & Computing | 2005
Dobromir Petkov Dobrev; Tatyana Neycheva; Nikolay Mudrov
A simple, cost effective circuit for a two-electrode non-differential biopotential amplifier is proposed. It uses a ‘virtual ground’ transimpedance amplifier and a parallel RC network for input common mode current equalisation, while the signal input impedance preserves its high value. With this innovative interface circuit, a simple non-inverting amplifier fully emulates high CMRR differential. The amplifier equivalent CMRR (typical range from 70–100 dB) is equal to the open loop gain of the operational amplifier used in the transimpedance interface stage. The circuit has very simple structure and utilises a small number of popular components. The amplifier is intended for use in various two-electrode applications, such as Holter-type monitors, defibrillators, ECG monitors, biotelemetry devices etc.
Journal of Experimental & Clinical Cancer Research | 2008
Enrico P. Spugnini; Ivan Dotsinsky; Nikolay Mudrov; Gennaro Citro; Alfredo D'avino; Alfonso Baldi
Stickers sarcoma (also known as transmissible venereal tumor) is a horizontally transmitted neoplasm of the dog, that is passed with coitus. It is a locally aggressive tumor with a low tendency to metastatic spread. The most common locations are the genitals, the nose, the perianal area. Standard treatment consists with chemotherapy with vincristine, however other therapies such as, cryotherapy, immunotherapy or, in selected cases, radiation therapy, have been reported. In this article we describe the outcome of a small cohort of canine patients, with chemotherapy resistant transmissible venereal tumor (TVT), treated with bleomycin selectively driven by trains of biphasic pulses (electrochemotherapy). Three canine patients, with refractory TVT, entered the study and received two sessions of ECT under sedation. The pets had local injection of bleomycin at the concentration of 1.5 mg/ml and five minutes after the chemotherapy, trains of 8 biphasic electric pulses lasting 50 + 50 μs each, with 1 ms interpulse intervals, were delivered by means of modified caliper or, for difficult districts, through paired needle electrode. All the patients responded to the treatment and are still in remission at different times. Electrochemotherapy appears as a safe and efficacious modality for the treatment of TVT and warrants further investigations.
Physiological Measurement | 2008
Dobromir Petkov Dobrev; Tatyana Neycheva; Nikolay Mudrov
This paper presents a simple digital approach for adaptive power-line (PL) or other periodic interference extraction. By means of two digital square (or sine) wave mixers, the real and imaginary parts of the interference are found, and the interference waveform is synthesized and finally subtracted. The described technique can be implemented in an open-loop architecture where the interference is synthesized as a complex sinusoid or in a closed-loop architecture for automatic phase and gain control. The same approach can be used for removal of the fundamental frequency of the PL interference as well as its higher harmonics. It is suitable for real-time operation with popular low-cost microcontrollers.
Veterinary Journal | 2009
Enrico P. Spugnini; Bruno Vincenzi; Gennaro Citro; Giuseppe Tonini; Ivan Dotsinsky; Nikolay Mudrov; Alfonso Baldi
Medical & Biological Engineering & Computing | 2008
Dobromir Dobrev; Tatyana Neycheva; Nikolay Mudrov
Journal of Experimental & Clinical Cancer Research | 2007
Enrico P. Spugnini; Gennaro Citro; Mellone P; Ivan Dotsinsky; Nikolay Mudrov; Alfonso Baldi
Veterinary Journal | 2008
Enrico P. Spugnini; Gennaro Citro; Ivan Dotsinsky; Nikolay Mudrov; Pasquale Mellone; Alfonso Baldi
in Vivo | 2007
Enrico P. Spugnini; Bruno Vincenzi; Gennaro Citro; Daniele Santini; Ivan Dotsinsky; Nikolay Mudrov; Vincenzo Montesarchio; Maria Teresa Laieta; Vincenzo Esposito; Alfonso Baldi
in Vivo | 2007
Enrico P. Spugnini; Marino Filipponi; Luca Romani; Ivan Dotsinsky; Nikolay Mudrov; Adone Baroni; Eleonora Ruocco; Maria Teresa Laieta; Vincenzo Montesarchio; Roberto Cassandro; Gennaro Citro; Alfonso Baldi