Nils Billecke
Charité
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Nils Billecke.
European Journal of Neuroscience | 2010
Antje Diestel; Silke Troeller; Nils Billecke; Igor M. Sauer; Felix Berger; Katharina Rose Luise Schmitt
Despite the widespread interest in the clinical applications of hypothermia, the cellular mechanisms of hypothermia‐induced neuroprotection have not yet been clearly understood. Therefore, the aim of this study was to elucidate the cellular effects of clinically relevant hypothermia and rewarming on the morphological and functional characteristics of microglia. Microglial cells were exposed to a dynamic cooling and rewarming protocol. For stimulation, microglial cells were treated with 1 μg/mL lipopolysaccharide (LPS). We found that hypothermia led to morphological changes from ramified to ameboid cell shapes. At 2 h after hypothermia and rewarming, microglial cells were again ramified with extended branches. Moreover, we found enhanced cell activation after rewarming, accompanied by increased phagocytosis and adenosine triphosphate consumption. Interestingly, hypothermia and rewarming led to a time‐dependent significant up‐regulation of the anti‐inflammatory cytokines interleukin‐10 and interleukin‐1 receptor antagonist in stimulated microglial cells. This is in line with the reduced proliferation and time‐dependent down‐regulation of the pro‐inflammatory cytokines tumor necrosis factor‐alpha and monocyte chemotactic protein‐1 in comparison to normothermic control cells after LPS stimulation. Furthermore, degradation of the inhibitor of the nuclear transcription factor‐kappaB (IkappaB‐alpha) was diminished and delayed under conditions of cooling and rewarming in LPS‐stimulated microglial cells. Thus, our results show that hypothermia and rewarming activate microglial cells, increase phagocytosis and shift the balance of cytokine release in stimulated microglial cells towards the anti‐inflammatory cytokines. This could be a new cellular mechanism of hypothermia‐induced neuroprotection mediated by activated microglial cells.
American Journal of Physiology-regulatory Integrative and Comparative Physiology | 2011
Nathanael Raschzok; Wiebke Werner; Hannes Sallmon; Nils Billecke; Christof Dame; Peter Neuhaus; Igor M. Sauer
The liver has the unique capacity to regenerate after surgical resection. However, the regulation of liver regeneration is not completely understood. Recent reports indicate an essential role for small noncoding microRNAs (miRNAs) in the regulation of hepatic development, carcinogenesis, and early regeneration. We hypothesized that miRNAs are critically involved in all phases of liver regeneration after partial hepatectomy. We performed miRNA microarray analyses after 70% partial hepatectomy in rats under isoflurane anesthesia at different time points (0 h to 5 days) and after sham laparotomy. Putative targets of differentially expressed miRNAs were determined using a bioinformatic approach. Two-dimensional (2D)-PAGE proteomic analyses and protein identification were performed on specimens at 0 and 24 h after resection. The temporal dynamics of liver regeneration were characterized by 5-bromo- 2-deoxyuridine, proliferating cell nuclear antigen, IL-6, and hepatocyte growth factor. We demonstrate that miRNA expression patterns changed during liver regeneration and that these changes were most evident during the peak of DNA replication at 24 h after resection. Expression of 13 miRNAs was significantly reduced 12-48 h after resection (>25% change), out of which downreguation was confirmed in isolated hepatocytes for 6 miRNAs at 24 h, whereas three miRNAs were significantly upregulated. Proteomic analysis revealed 65 upregulated proteins; among them, 23 represent putative targets of the differentially expressed miRNAs. We provide a temporal miRNA expression and proteomic dataset of the regenerating rat liver, which indicates a primary function for miRNA during the peak of DNA replication. These data will assist further functional studies on the role of miRNAs during liver regeneration.
Journal of Cellular and Molecular Medicine | 2008
Nathanael Raschzok; Mehmet H. Morgul; Jens Pinkernelle; Florian W. R. Vondran; Nils Billecke; Nora N. Kammer; Gesine Pless; Michaela K. Adonopoulou; Christian Leist; Lars Stelter; Ulf Teichgräber; Ruth Schwartlander; Igor M. Sauer
Transplantation of primary human hepatocytes is a promising approach in certain liver diseases. For the visualization of the hepa‐tocytes during and following cell application and the ability of a timely response to potential complications, a non‐invasive modality for imaging the transplanted cells has to be established. The aim of this study was to label primary human hepatocytes with micron‐sized iron oxide particles (MPIOs), enabling the detection of cells by clinical magnetic resonance imaging (MRI). Primary human hepatocytes isolated from 13 different donors were used for the labelling experiments. Following the dose‐finding studies, hepatocytes were incubated with 30 particles/cell for 4 hrs in an adhesion culture. Particle incorporation was investigated via light, fluorescence and electron microscopy, and labelled cells were fixed and analysed in an agarose suspension by a 3.0 Tesla MR scanner. The hepatocytes were enzymatically resuspended and analysed during a 5‐day reculture period for viability, total protein, enzyme leakage (aspartate aminotransferase [AST], lactate dehydrogenase [LDH]) and metabolic activity (urea, albumin). A mean uptake of 18 particles/cell could be observed, and the primary human hepatocytes were clearly detectable by MR instrumentation. The particle load was not affected by resuspension and showed no alternations during the culture period. Compared to control groups, labelling and resuspension had no adverse effects on the viability, enzyme leakage and metabolic activity of the human hepatocytes. The feasibility of preparing MPIO‐labelled primary human hepatocytes detectable by clinical MR equipment was shown in vitro. MPIO‐labelled cells could serve for basic research and quality control in the clinical setting of human hepatocyte transplantation.
Journal of Heart and Lung Transplantation | 2009
Antje Diestel; Nils Billecke; Joerg Roessler; Boris Schmitt; Silke Troeller; Ruth Schwartlander; Felix Berger; Igor M. Sauer; Katharina Rose Luise Schmitt
BACKGROUND Hypothermia is used to preserve organs for transplantation and is the oldest method to protect organs during complex pediatric cardiac surgery. Loss of tissue function and tissue edema are common complications in children undergoing corrective cardiac surgery and heart transplantation. The present study was designed to examine the effects of methylprednisolone and tacrolimus on endothelial cell function and morphology after deep hypothermia and rewarming. METHODS Human umbilical vein endothelial cells were pre-treated with methylprednisolone or tacrolimus, or both, incubated within a specially designed bioreactor or in monolayers, and then exposed to a dynamic cooling and rewarming protocol. Immunocytochemistry, time-lapse video microscopy, cell permeability and adherence assays, and Western blot analysis were performed. RESULTS Confluent endothelial cells exposed to hypothermia displayed elongated cell shapes with intercellular gap formation, increased endothelial cell-layer permeability, and loss in adherence. Upon rewarming, however, endothelial cell integrity was restored. Opening and closing of intercellular gaps was dependent on extracellular signal-regulated kinase 1 and 2 (ERK 1/2) activation and connexin 43 expression. The combined treatment with methylprednisolone and tacrolimus inhibited these hypothermia-induced changes. CONCLUSIONS These results suggest that methylprednisolone and tacrolimus inhibit hypothermia-induced endothelial gap formation by phosphorylated ERK 1/2 inhibition and connexin 43 stabilization. Application of combined drugs that affect multiple targets may therefore be considered as a possible new therapeutic strategy to prevent endothelial dysfunction after hypothermia and rewarming.
Cell medicine | 2010
Nathanael Raschzok; Ulf Teichgräber; Nils Billecke; Anja Zielinski; Kirsten Steinz; Nora N. Kammer; Mehmet Haluk Morgul; Sarah Schmeisser; Michaela K. Adonopoulou; Lars Morawietz; Bernhard Hiebl; Ruth Schwartlander; Wolfgang Rüdinger; Bernd Hamm; Peter Neuhaus; Igor M. Sauer
Liver cell transplantation (LCT) is a promising treatment approach for certain liver diseases, but clinical implementation requires methods for noninvasive follow-up. Labeling with superparamagnetic iron oxide particles can enable the detection of cells with magnetic resonance imaging (MRI). We investigated the feasibility of monitoring transplanted liver cells by MRI in a preclinical swine model and used this approach to evaluate different routes for cell application. Liver cells were isolated from landrace piglets and labeled with micron-sized iron oxide particles (MPIO) in adhesion. Labeled cells (n = 10), native cells (n = 3), or pure particles (n = 4) were transplanted to minipigs via intraportal infusion into the liver, direct injection into the splenic parenchyma, or intra-arterial infusion to the spleen. Recipients were investigated by repeated 3.0 Tesla MRI and computed tomography angiography up to 8 weeks after transplantation. Labeling with MPIO, which are known to have a strong effect on the magnetic field, enabled noninvasive detection of cell aggregates by MRI. Following intraportal application, which is commonly applied for clinical LCT, MRI was able to visualize the microembolization of transplanted cells in the liver that were not detected by conventional imaging modalities. Cells directly injected into the spleen were retained, whereas cell infusions intra-arterially into the spleen led to translocation and engraftment of transplanted cells in the liver, with significantly fewer microembolisms compared to intraportal application. These findings demonstrate that MRI can be a valuable tool for noninvasive elucidation of cellular processes of LCT and-if clinically applicable MPIO are available-for monitoring of LCT under clinical conditions. Moreover, the results clarify mechanisms relevant for clinical practice of LCT, suggesting that the intra-arterial route to the spleen deserves further evaluation.
Tissue Engineering Part C-methods | 2009
Nathanael Raschzok; Nils Billecke; Nora N. Kammer; Mehmet Haluk Morgul; Michaela K. Adonopoulou; Igor M. Sauer; Stefan Florek; Helmut Becker-Roß; Mao Dong Huang
Detection of cells after transplantation is necessary for quality control in regenerative medicine. Labeling with micron-sized iron oxide particles enables noninvasive detection of single cells by magnetic resonance imaging. However, techniques for evaluation of the particle uptake are challenging. The aim of this study was to investigate continuum source atomic absorption spectrometry (CSAAS) for this purpose. Porcine liver cells were labeled with micron-sized iron oxide particles, and the iron concentration of the cell samples was investigated by a CSAAS spectrometer equipped with a Perkin-Elmer THGA graphite furnace. The weak iron line at 305.754 nm provides only about 1/600 sensitivity of the iron resonance line at 248.327 nm and was used for CSAAS measurements. Iron concentrations measured from labeled cells ranged from 5.8 +/- 0.3 to 25.8 +/- 0.9 pg Fe/cell, correlating to an uptake of 8.2 +/- 0.5 to 25.7 +/- 0.8 particles/cell. The results were verified by standardized morphometric evaluation. CSAAS enabled rapid quantification of particle load from small quantities of cells without extensive preparation steps. Thereby, CSAAS could be used for quality control in a clinical setting of cell transplantation.
Cell Transplantation | 2013
Nathanael Raschzok; Carolin M. Langer; Christian A. Schmidt; Karl H. Lerche; Nils Billecke; Kerstin Nehls; Natalie B. Schlüter; Annekatrin Leder; Susanne Rohn; Martina Mogl; Lutz Lüdemann; Lars Stelter; Ulf Teichgräber; Peter Neuhaus; Igor M. Sauer
Cellular therapies require methods for noninvasive visualization of transplanted cells. Micron-sized iron oxide particles (MPIOs) generate a strong contrast in magnetic resonance imaging (MRI) and are therefore ideally suited as an intracellular contrast agent to image cells under clinical conditions. However, MPIOs were previously not applicable for clinical use. Here, we present the development and evaluation of silica-based micron-sized iron oxide particles (sMPIOs) with a functionalizable particle surface. Particles with magnetite content of >40% were composed using the sol-gel process. The particle surfaces were covered with COOH groups. Fluorescein, poly-l-lysine (PLL), and streptavidin (SA) were covalently attached. Monodisperse sMPIOs had an average size of 1.18 μm and an iron content of about 1.0 pg Fe/particle. Particle uptake, toxicity, and imaging studies were performed using HuH7 cells and human and rat hepatocytes. sMPIOs enabled rapid cellular labeling within 4 h of incubation; PLL-modified particles had the highest uptake. In T2*-weighted 3.0 T MRI, the detection threshold in agarose was 1,000 labeled cells, whereas in T1-weighted LAVA sequences, at least 10,000 cells were necessary to induce sufficient contrast. Labeling was stable and had no adverse effects on labeled cells. Silica is a biocompatible material that has been approved for clinical use. sMPIOs could therefore be suitable for future clinical applications in cellular MRI, especially in settings that require strong cellular contrast. Moreover, the particle surface provides the opportunity to create multifunctional particles for targeted delivery and diagnostics.
Artificial Organs | 2011
Nora N. Kammer; Nils Billecke; Mehmet Haluk Morgul; Michaela K. Adonopoulou; Martina Mogl; Mao D. Huang; Stefan Florek; Katharina Rose Luise Schmitt; Nathanael Raschzok; Igor M. Sauer
Labeling of hepatocytes with micron-sized iron oxide particles (MPIOs) enables cell detection using clinical magnetic resonance equipment. For clinical applications, large numbers of cells must be labeled in a simple and rapid manner and have to be applied in suspension. However, all existing protocols are based on adhesion culture labeling with subsequent resuspension, only suitable for small experimental settings. The aim of this study was to investigate the feasibility of preparing MPIO-labeled primary human hepatocytes in a temporary suspension culture. Human hepatocytes were isolated from 16 donors and labeled with MPIOs in suspension, using the Rotary Cell Culture System. Particle incorporation was investigated by light and electron microscopy. Cells were compared with adhesion culture-labeled and subsequently enzymatically resuspended cells. During a period of 5 days, hepatocyte-specific parameters of cell damage (aspartate aminotransferase and alanine aminotransferase) and metabolic activity (urea and albumin) were analyzed (n=7). Suspension cultures showed a higher outcome in cell recovery compared with the conventional labeling method. When incubated with 180 particles/viable cell for 4 h, the mean particle uptake was 28.8 particles/cell at a labeling efficiency of 95.1%. Labeling in suspension had no adverse effects on cell integrity or metabolic activity. We conclude that labeling of human hepatocytes in suspension is feasible and simple and may serve future large-scale processing of cells.
American Journal of Roentgenology | 2012
Nathanael Raschzok; Jens Pinkernelle; Nils Billecke; Kerstin Nehls; Maciej Powerski; Igor M. Sauer; Ulf Teichgräber
OBJECTIVE Liver cell transplantation is a promising approach for the treatment of metabolic liver disorders. However, a method for noninvasive monitoring during liver cell transplantation is not available clinically. The aim of this study was to investigate the feasibility of fast dynamic MRI monitoring during liver cell infusion to the spleen, which is considered an ectopic implantation site for liver cell transplantation. MATERIALS AND METHODS Porcine liver cells were labeled with micron-sized iron oxide particles and infused to the spleens of pigs (n = 5) via the lineal artery. MRI was performed using a 3-T MR scanner. Initially, T1- and T2-weighted pulse sequences were tested. Thereafter, fast dynamic MRI was performed during cell infusion. MR findings were verified by immunohistological examinations. RESULTS Images from static MRI (TR/TE, 2500/105.2) showed significantly lower signal intensity and signal-to-noise ratio after cell infusion compared with pretransplant images. T2-weighted fast dynamic MRI enabled visualization of signal decrease of the spleen during cell infusion. When cells were infused systemically, no signal changes in the spleen were observed. CONCLUSION This study shows that fast dynamic MRI can enable noninvasive monitoring during liver cell transplantation to the spleen. This approach could be useful for preclinical studies and for quality control of clinical liver cell transplantation.
Journal of Biotechnology | 2012
Nils Billecke; Nathanael Raschzok; Susanne Rohn; Mehmet Haluk Morgul; Ruth Schwartlander; Martina Mogl; Sonja Wollersheim; Katharina Rose Luise Schmitt; Igor M. Sauer
Cell morphology, proliferation and motility, as well as mono- and heterotypic cell-to-cell interactions, are of increasing interest for in vitro experiments. However, tightly controlling culture conditions whilst simultaneously monitoring the same set of cells is complicated. Moreover, video-microscopy of distinct cells or areas of cells over a prolonged period of time represents a technical challenge. The SlideObserver was designed for cinemicrography of cells in co-and monoculture. The core elements of the system are the SlideReactors, miniaturised hollow fibre-based bioreactors operated in closed perfusion loops. Within the SlideReactors, cells can be cultured under adaptable conditions as well as in direct- and indirect co-culture. The independent perfusion loops enable controlled variation of parameters such as medium, pH, and oxygenation. A combined automated microscope stage and camera set-up allows for micrograph acquisition of multiple user-defined regions of interest within the bioreactor units. For proof of concept, primary cells (HUVEC, human hepatocytes) and cell lines (HuH7, THP-1) were cultured under stable and varying culture conditions, as well as in mono- and co-culture. The operational system enabled non-stop imaging and automated control of process parameters as well as elective manipulation of either reactor. As opposed to non-perfused culture systems or comparable devices for cinemicrographic analysis, the SlideObserver allows simultaneous morphological monitoring of an entire culture of cells in multiple bioreactors.