Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Nils Dahlström is active.

Publication


Featured researches published by Nils Dahlström.


Journal of Computer Assisted Tomography | 2012

Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography.

Mannudeep K. Kalra; Nils Dahlström; Sarabjeet Singh; Maria Lindblom; Garry Choy; Petter Quick; Bernhard Schmidt; Martin Sedlmair; Michael A. Blake; Anders Persson

Purpose The objective of this study was to assess the effect of Sinogram Affirmed Iterative Reconstruction (SAFIRE) and filtered back-projection (FBP) techniques on abdominal computed tomography (CT) performed with 50% and 75% radiation dose reductions. Methods Twenty-four patients (mean age, 64 ± 14 years; male-female ratio, 10:14) gave informed consent for an institutional review board–approved prospective study involving acquisition of additional research images through the abdomen on 128-slice multi–detector-row CT (SOMATOM Definition Flash) at quality reference mAs of 100 (50% lower dose) and 50 (75% lower dose) over a scan length of 10 cm using combined modulation (CARE Dose 4D). Standard-of-care abdominal CT was performed at 200 quality reference mAs, with remaining parameters held constant. The 50- and 100-mAs data sets were reconstructed with FBP and at 4 SAFIRE settings (S1, S2, S3, S4). Higher number of SAFIRE settings denotes increased strength of the algorithm resulting in lower image noise. Two abdominal radiologists independently compared the FBP and SAFIRE images for lesion number, location, size and conspicuity, and visibility of small structures, image noise, and diagnostic confidence. Objective noise and Hounsfield units (HU) were measured in the liver and the descending aorta. Results All 43 lesions were detected on both FBP and SAFIRE images. Minor blocky, pixelated appearance of 50% and 75% reduced dose images was noted at S3 and S4 SAFIRE but not at S1 and S2 settings. Subjective noise was suboptimal in both 50% and 75% lower-dose FBP images but was deemed acceptable on all SAFIRE settings. Sinogram Affirmed Iterative Reconstruction images were deemed acceptable in all patients at 50% lower dose and in 22 of 24 patients at 75% lower dose. As compared with 75% reduced dose FBP, objective noise was lower by 22.8% (22.9/29.7), 35% (19.3/29.7), 44.3% (16.7/29.3), and 54.8% (13.4/29.7) on S1 to S4 settings, respectively (P < 0.001). Conclusions Sinogram Affirmed Iterative Reconstruction–enabled reconstruction provides abdominal CT images without loss in diagnostic value at 50% reduced dose and in some patients also at 75% reduced dose.


Acta Radiologica | 2007

Contrast-enhanced magnetic resonance cholangiography with Gd-BOPTA and Gd-EOB-DTPA in healthy subjects

Nils Dahlström; Anders Persson; Nils Albiin; Örjan Smedby; Torkel B. Brismar

Purpose: To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance®) and Gd-EOB-DTPA (Primovist®) in normal healthy subjects. Material and Methods: Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences between the common hepatic duct (CHD) and liver parenchyma were measured before and 10, 20, 30, 40, 130, 240, and 300 min after contrast medium injection. Results: Biliary enhancement was obvious 10 min post-injection for Gd-EOB-DTPA and was noted at 20 min for Gd-BOPTA. At 40 min delay, Gd-BOPTA reached its peak biliary enhancement, but at neither 30 nor 40 min delay was there any significant difference compared with that of Gd-EOB-DTPA. At later delays, the contrast between CHD and liver continued to increase for Gd-EOB-DTPA, whereas it decreased for Gd-BOPTA. Conclusion: The earlier onset and longer duration of a high contrast between CHD and liver for Gd-EOB-DTPA facilitates examination of hepatobiliary excretion. Therefore, Gd-EOB-DTPA may provide adequate hepatobiliary imaging within a shorter time span than Gd-BOPTA and facilitate scheduling at the MR unit. Further studies in patients are required to compare the imaging advantages of Gd-EOB-DTPA and Gd-BOPTA in clinical practice.


American Journal of Roentgenology | 2013

Sinogram-affirmed iterative reconstruction of low-dose chest CT: effect on image quality and radiation dose.

Mannudeep K. Kalra; Nils Dahlström; Sarabjeet Singh; Subbarao Digumarthy; Synho Do; Homer Pien; Petter Quick; Bernhard Schmidt; Martin Sedlmair; Jo-Anne O. Shepard; Anders Persson

OBJECTIVE. The purpose of this study is to compare sinogram-affirmed iterative reconstruction (SAFIRE) and filtered back projection (FBP) reconstruction of chest CT acquired with 65% radiation dose reduction. MATERIALS AND METHODS. In this prospective study involving 24 patients (11 women and 13 men; mean [± SD] age, 66 ± 10 years), two scan series were acquired using 100 and 40 Quality Reference mAs over a 10-cm scan length in the chest with a 128-MDCT scanner. The 40 Quality Reference mAs CT projection data were reconstructed with FBP and four settings of SAFIRE (S1, S2, S3, and S4). Six image datasets (FBP with 100 and 40 Quality Reference mAs, and S1, S2, S3, S4 with 40 Quality Reference mAs) were displayed on a DICOM-compliant 55-inch 2-megapixel monitor for blinded evaluation by two thoracic radiologists for number and location of lesions, lesion size, lesion margins, visibility of small structures and fissures, and diagnostic confidence. Objective noise and CT values were measured in thoracic aorta for each image series, and the noise power spectrum was assessed. Data were analyzed with analysis of variance and Wilcoxon signed rank tests. RESULTS. All 186 lesions were seen on 40 Quality Reference mAs SAFIRE images. Diagnostic confidence on SAFIRE images was higher than that for FBP images. Except for the minor blotchy appearance on SAFIRE settings S3 and S4, no significant artifacts were noted. Objective noise with 40 Quality Reference mAs S1 images (21.1 ± 6.1 SD of HU) was significantly lower than that for 40 Quality Reference mAs FBP images (28.5 ± 8.1 SD of HU) (p < 0.001). Noise power spectra were identical for SAFIRE and FBP with progressive noise reduction with higher iteration SAFIRE settings. CONCLUSION. Iterative reconstruction (SAFIRE) allows reducing the radiation exposure by approximately 65% without losing diagnostic information in chest CT.


Acta Radiologica | 2009

Liver vessel enhancement by Gd-BOPTA and Gd-EOB-DTPA- a comparison in healthy volunteers

Torkel B. Brismar; Nils Dahlström; Nick Edsborg; Anders Persson; Örjan Smedby; Nils Albiin

Background: A thorough understanding of magnetic resonance (MR) contrast media dynamics makes it possible to choose the optimal contrast media for each investigation. Differences in visualizing hepatobiliary function between Gd-BOPTA and Gd-EOB-DTPA have previously been demonstrated, but less has been published regarding differences in liver vessel visualization. Purpose: To compare the liver vessel and liver parenchymal enhancement dynamics of Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist). Material and Methods: The signal intensity of the liver parenchyma, the common hepatic artery, the middle hepatic vein, and a segmental branch of the right portal vein was obtained in 10 healthy volunteers before contrast media administration, during arterial and portal venous phases, and 10, 20, 30, 40, and 130 min after intravenous contrast medium injection, but, due to scanner limitations, not during the hepatic venous phase. The doses of contrast media were 0.1 mmol/kg for Gd-BOPTA and 0.025 mmol/kg for Gd-EOB-DTPA. Results: Maximum enhancement of liver parenchyma was observed from the portal venous phase until 130 min after Gd-BOPTA administration and from 10 min to 40 min after Gd-EOB-DTPA. There was no difference in maximum enhancement of liver parenchyma between the two contrast media. When using Gd-BOPTA, the vascular contrast enhancement was still apparent 40 min after injection, but had vanished 10 min after Gd-EOB-DTPA injection. The maximum difference in signal intensity between the vessels and the liver parenchyma was significantly greater with Gd-BOPTA than with Gd-EOB-DTPA (P<0.0001). Conclusion: At the dosage used in this study, Gd-BOPTA yields higher maximum enhancement of the hepatic artery, portal vein, and middle hepatic vein during the arterial and the portal venous phase and during the delayed phases than Gd-EOB-DTPA does, whereas there is no difference in liver parenchymal enhancement between the two contrast agents.


BMC Medical Imaging | 2006

Three-dimensional drip infusion CT cholangiography in patients with suspected obstructive biliary disease: a retrospective analysis of feasibility and adverse reaction to contrast material.

Anders Persson; Nils Dahlström; Örjan Smedby; Torkel B. Brismar

BackgroundComputed Tomography Cholangiography (CTC) is a fast and widely available alternative technique to visualise hepatobiliary disease in patients with an inconclusive ultrasound when MRI cannot be performed. The method has previously been relatively unknown and sparsely used, due to concerns about adverse reactions and about image quality in patients with impaired hepatic function and thus reduced contrast excretion. In this retrospective study, the feasibility and the frequency of adverse reactions of CTC when using a drip infusion scheme based on bilirubin levels were evaluated.MethodsThe medical records of patients who had undergone upper abdominal spiral CT with subsequent three-dimensional rendering of the biliary tract by means of CTC during seven years were retrospectively reviewed regarding serum bilirubin concentration, adverse reaction and presence of visible contrast media in the bile ducts at CT examination. In total, 153 consecutive examinations in 142 patients were reviewed.ResultsContrast media was observed in the bile ducts at 144 examinations. In 110 examinations, the infusion time had been recorded in the medical records. Among these, 42 examinations had an elevated bilirubin value (>19 umol/L). There were nine patients without contrast excretion; 3 of which had a normal bilirubin value and 6 had an elevated value (25–133 umol/L). Two of the 153 examinations were inconclusive. One subject (0.7%) experienced a minor adverse reaction – a pricking sensation in the face. No other adverse effects were noted.ConclusionWe conclude that drip infusion CTC with an infusion rate of the biliary contrast agent iotroxate governed by the serum bilirubin value is a feasible and safe alternative to MRC in patients with and without impaired biliary excretion.In this retrospective study the feasibility and the frequency of adverse reactions when using a drip infusion scheme based on bilirubin levels has been evaluated.


Acta Radiologica | 2004

Volume rendering compared with maximum intensity projection for magnetic resonance angiography measurements of the abdominal aorta

Anders Persson; Nils Dahlström; Lena Engellau; Elna-Marie Larsson; Torkel B. Brismar; Örjan Smedby

Purpose: To compare the volume rendering technique (VRT) with maximum intensity projection (MIP) for aortic diameter measurements in MR angiography (MRA) data sets. Material and Methods: Existing contrast‐enhanced 3‐dimensional MRA and digital subtraction angiography (DSA) data sets from 20 patients were analyzed. In each MRA data set, two aortic diameters were measured using MIP and VRT. Agreement with DSA measurements, dependence on rendering parameters, and interobserver agreement were assessed. Results: Diameters measured on MIP with fixed parameters showed no significant difference compared with DSA and with freely selected parameters a slight overestimation relative to DSA. Diameters measured on VRT were larger than on DSA. For both MIP and VRT, the measurements depended on the chosen parameters. The error relative to DSA was larger for VRT than for MIP with fixed parameters but not with freely chosen parameters. Interobserver agreement did not differ significantly. Conclusions: VRT is not suitable for diameter measurements of the abdominal aorta with fixed parameter settings but may be useful with user‐selected settings.


Acta Radiologica | 2006

Standardized Volume Rendering for Magnetic Resonance Angiography Measurements in the Abdominal Aorta

Anders Persson; Torkel B. Brismar; Claes Lundström; Nils Dahlström; F. Othberg; Örjan Smedby

Purpose: To compare three methods for standardizing volume rendering technique (VRT) protocols by studying aortic diameter measurements in magnetic resonance angiography (MRA) datasets. Material and Methods: Datasets from 20 patients previously examined with gadolinium-enhanced MRA and with digital subtraction angiography (DSA) for abdominal aortic aneurysm were retrospectively evaluated by three independent readers. The MRA datasets were viewed using VRT with three different standardized transfer functions: the percentile method (Pc-VRT), the maximum-likelihood method (ML-VRT), and the partial range histogram method (PRH-VRT). The aortic diameters obtained with these three methods were compared with freely chosen VRT parameters (F-VRT) and with maximum intensity projection (MIP) concerning inter-reader variability and agreement with the reference method DSA. Results: F-VRT parameters and PRH-VRT gave significantly higher diameter values than DSA, whereas Pc-VRT gave significantly lower values than DSA. The highest interobserver variability was found for F-VRT parameters and MIP, and the lowest for Pc-VRT and PRH-VRT. All standardized VRT methods were significantly superior to both MIP and F-VRT in this respect. The agreement with DSA was best for PRH-VRT, which was the only method with a mean error below 1 mm and which also had the narrowest limits of agreement (95% of cases between 2.1 mm below and 3.1 mm above DSA). Conclusion: All the standardized VRT methods compare favorably with MIP and VRT with freely selected parameters as regards interobserver variability. The partial range histogram method, although systematically overestimating vessel diameters, gives results closest to those of DSA.


Metabolism-clinical and Experimental | 2016

A randomized trial of cold-exposure on energy expenditure and supraclavicular brown adipose tissue volume in humans.

Thobias Romu; Camilla Vavruch; Olof Dahlqvist-Leinhard; Joakim Tallberg; Nils Dahlström; Anders Persson; Mikael Heglind; Martin E. Lidell; Sven Enerbäck; Magnus Borga; Fredrik Nyström

OBJECTIVE To study if repeated cold-exposure increases metabolic rate and/or brown adipose tissue (BAT) volume in humans when compared with avoiding to freeze. DESIGN Randomized, open, parallel-group trial. METHODS Healthy non-selected participants were randomized to achieve cold-exposure 1hour/day, or to avoid any sense of feeling cold, for 6weeks. Metabolic rate (MR) was measured by indirect calorimetry before and after acute cold-exposure with cold vests and ingestion of cold water. The BAT volumes in the supraclavicular region were measured with magnetic resonance imaging (MRI). RESULTS Twenty-eight participants were recruited, 12 were allocated to controls and 16 to cold-exposure. Two participants in the cold group dropped out and one was excluded. Both the non-stimulated and the cold-stimulated MR were lowered within the group randomized to avoid cold (MR at room temperature from 1841±199 kCal/24h to 1795±213 kCal/24h, p=0.047 cold-activated MR from 1900±150 kCal/24h to 1793±215 kCal/24h, p=0.028). There was a trend towards increased MR at room temperature following the intervention in the cold-group (p=0.052). The difference between MR changes by the interventions between groups was statistically significant (p=0.008 at room temperature, p=0.032 after cold-activation). In an on-treatment analysis after exclusion of two participants that reported ≥8days without cold-exposure, supraclavicular BAT volume had increased in the cold-exposure group (from 0.0175±0.015l to 0.0216±0.014l, p=0.049). CONCLUSIONS We found evidence for plasticity in metabolic rate by avoiding to freeze compared with cold-exposure in a randomized setting in non-selected humans.


PLOS ONE | 2014

Physiologically Realistic and Validated Mathematical Liver Model Revels Hepatobiliary Transfer Rates for Gd-EOB-DTPA Using Human DCE-MRI Data

Mikael Forsgren; Olof Dahlqvist Leinhard; Nils Dahlström; Gunnar Cedersund; Peter Lundberg

Objectives Diffuse liver disease (DLD), such as non-alcoholic fatty liver disease (NASH) and cirrhosis, is a rapidly growing problem throughout the Westernized world. Magnetic resonance imaging (MRI), based on uptake of the hepatocyte-specific contrast agent (CA) Gd-EOB-DTPA, is a promising non-invasive approach for diagnosing DLD. However, to fully utilize the potential of such dynamic measurements for clinical or research purposes, more advanced methods for data analysis are required. Methods A mathematical model that can be used for such data-analysis was developed. Data was obtained from healthy human subjects using a clinical protocol with high spatial resolution. The model is based on ordinary differential equations and goes beyond local diffusion modeling, taking into account the complete system accessible to the CA. Results The presented model can describe the data accurately, which was confirmed using chi-square statistics. Furthermore, the model is minimal and identifiable, meaning that all parameters were determined with small degree of uncertainty. The model was also validated using independent data. Conclusions We have developed a novel approach for determining previously undescribed physiological hepatic parameters in humans, associated with CA transport across the liver. The method has a potential for assessing regional liver function in clinical examinations of patients that are suffering of DLD and compromised hepatic function.


Magnetic Resonance in Medicine | 2017

Robust water fat separated dual‐echo MRI by phase‐sensitive reconstruction

Thobias Romu; Nils Dahlström; Olof Dahlqvist Leinhard; Magnus Borga

The purpose of this work was to develop and evaluate a robust water‐fat separation method for T1‐weighted symmetric two‐point Dixon data.

Collaboration


Dive into the Nils Dahlström's collaboration.

Top Co-Authors

Avatar

Örjan Smedby

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Torkel B. Brismar

Karolinska University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge