Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Nobue Uchida is active.

Publication


Featured researches published by Nobue Uchida.


Acta Radiologica | 2008

Usefulness of Diffusion-Weighted Imaging and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in the Diagnosis of Prostate Transition-Zone Cancer

Takeshi Yoshizako; Akihiko Wada; Takafumi Hayashi; Koji Uchida; Masahiro Sumura; Nobue Uchida; Hajime Kitagaki; Mikio Igawa

Background: Conventional T2-weighted (T2-WI) magnetic resonance imaging (MRI) has poor sensitivity for prostate transition-zone (TZ) cancer detection. Purpose: To retrospectively evaluate the clinical value of diffusion-weighted MRI (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) in combination with T2-WI for the diagnosis of TZ cancer. Material and Methods: Twenty-six TZ cancers in 23 patients with at least one tumor (tumor size >10 mm) located predominantly in the TZ were included in the study. Sixteen peripheral-zone (PZ) cancers in 12 patients with PZ cancer but without TZ cancer (control group) were selected by step-section pathologic maps. All patients underwent MRI and radical prostatectomy. MRI was obtained by a 1.5T superconducting system with a phased-array coil. Imaging sequences were T2-WI with fat saturation (FST2-WI), DW-MRI (single-shot echoplanar image, b=0 and 1000 s/mm2, apparent diffusion coefficient [ADC] map findings), and DCE-MRI (3D fast spoiled gradient recalled [SPGR], contrast medium [0.2 mmol/kg], total injection time 5 s, image acquisition 30, 60, and 90 s). Sensitivity, specificity, accuracy, and positive predictive value (PPV) for the diagnosis of TZ cancer were evaluated in four protocols: A) FST2-WI alone, B) FST2-WI plus DW-MRI, C) FST2-WI plus DCE-MRI, D) FST2-WI plus DW-MRI plus DCE-MRI. Results: Sensitivity, specificity, accuracy, and PPV in protocol A (FST2-WI alone) were 61.5%, 68.8%, 64.3%, and 76.2%, respectively. FST2-WI plus DW-MRI (protocol B) improved the sensitivity, specificity, accuracy, and PPV. In FST2-WI plus DW-MRI plus DCE-MRI (protocol D), the number of true-negative lesions increased and false-positive lesions decreased, and the sensitivity, specificity, accuracy, and PPV were 69.2%, 93.8%, 78.6%, and 94.7%, respectively. There was a significant difference between protocols A and D (P<0.05). Conclusion: Adding DW-MRI to FST2-WI in the diagnosis of prostate TZ cancer increased the diagnostic accuracy. The addition of DCE-MRI may be an option to improve the specificity and PPV of diagnosing TZ cancer with FST2-WI and DW-MRI.


International Journal of Radiation Oncology Biology Physics | 2009

Multi-institutional Analysis of Solitary Extramedullary Plasmacytoma of the Head and Neck Treated with Curative Radiotherapy

Ryohei Sasaki; Koichi Yasuda; Eisuke Abe; Nobue Uchida; Mitsuhiko Kawashima; Takashi Uno; Masayuki Fujiwara; Yoshiyuki Shioyama; Yoshikazu Kagami; Yuta Shibamoto; Kensei Nakata; Yoshie Takada; Tetsuya Kawabe; Kazuyuki Uehara; Ken-ichi Nibu; S. Yamada

PURPOSE The purpose of this study was to elucidate the efficacy and optimal method of radiotherapy in the management of solitary extramedullary plasmacytoma occurring in the head and neck regions (EMPHN). METHODS AND MATERIALS Sixty-seven patients (43 male and 24 female) diagnosed with EMPHN between 1983 and 2008 at 23 Japanese institutions were reviewed. The median patient age was 64 years (range, 12-83). The median dose administered was 50 Gy (range, 30-64 Gy). Survival data were calculated by the Kaplan-Meier method. RESULTS The median follow-up duration was 63 months. Major tumor sites were nasal or paranasal cavities in 36 (54%) patients, oropharynx or nasopharynx in 16 (23%) patients, orbita in 6 (9%) patients, and larynx in 3 (5%) patients. The 5- and 10-year local control rates were 95% and 87%, whereas the 5- and 10-year disease-free survival rates were 56% and 54%, respectively. There were 5 (7.5%), 12 (18%), and 8 (12%) patients who experienced local failure, distant metastasis, and progression to multiple myeloma, respectively. In total, 18 patients died, including 10 (15%) patients who died due to complications from EMPHN. The 5- and 10-year overall survival (OS) rates were 73% and 56%, respectively. Radiotherapy combined with surgery was identified as the lone significant prognostic factor for OS (p = 0.04), whereas age, gender, radiation dose, tumor size, and chemotherapy were not predictive. No patient experienced any severe acute morbidity. CONCLUSIONS Radiotherapy was quite effective and safe for patients with EMPHN. Radiotherapy combined with surgery produced a better outcome according to survival rates. These findings require confirmation by further studies with larger numbers of patients with EMPHN.


American Journal of Neuroradiology | 2008

Radiation-induced xerostomia: objective evaluation of salivary gland injury using MR sialography.

Akihiko Wada; Nobue Uchida; M. Yokokawa; T. Yoshizako; Hajime Kitagaki

BACKGROUND AND PURPOSE: Xerostomia (dry mouth) is one of the serious complications of head and neck irradiation and has a strong influence on a patients activities of daily living. MR sialography with salivary secretion stimulation provides additional functional information (salivary secretion reserve) and may contribute to the evaluation of the severity of xerostomia and predict the risk of developing a radiation-induced xerostomia. This aim of the study was to analyze MR sialography as an objective tool to evaluate radiation-induced salivary injury. MATERIALS AND METHODS: MR sialography with salivary secretion stimulation was performed in 16 patients with head and neck malignancy before and after irradiation therapy. Multivariate (stepwise multiple regression) analysis was performed to analyze the nonstimulated and stimulated MR sialography findings and the clinical severity of xerostomia. RESULTS: Multivariate analysis of the preirradiation study revealed no significant independent variables that could predict the clinical severity of xerostomia. In the postirradiation study, following regression with 2 independent variables (secretion response of the submandibular gland [rSG] and parotid gland visualization on stimulated MR sialography [sPG]) could explain 70% of the cases: xerostomia severity grade = 0.681 + 0.871 × rSG − 0.471 × sPG. CONCLUSIONS: MR sialography is a useful method for visualization of salivary gland radiation injury and estimation of the severity of radiation-induced xerostomia. Insufficiency of secretion reserve at the irradiated submandibular gland has the strongest influence on xerostomia severity. Our investigation suggests that careful submandibular gland protection may lead to prevention and avoidance of radiation-induced xerostomia.


European Journal of Radiology | 1993

MR imaging of vertebral metastases: evaluation of fat saturation imaging

Nobue Uchida; Kazuro Sugimura; Akiko Kajitani; Takeshi Yoshizako; Tetsuya Ishida

OBJECTIVE To compare conventional T1-weighted imaging (SE-T1) and chemical shift fat-saturation T1-weighted imaging (FS-T1) in the diagnosis of bone metastases. SUBJECTS Twenty-two patients (101 vertebrae) with non-neoplastic lesions (Group 1) and 21 patients (72 vertebrae) with spinal metastases (Group 2) were evaluated with both images. RESULTS The signal intensity (SI) distribution of Groups 1 and 2 on SE-T1 showed various patterns, and SI measurement was not significantly different between the two groups. On FS-T1, all non-neoplastic lesions had a low-intensity homogeneous appearance; however, the metastases had mixed to high SI. The SI measurement data of Group 2 was significantly (P < 0.0001) higher than that of Group 1. CONCLUSION FS-T1 was useful in evaluating vertebral metastases.


Clinical Imaging | 2013

Power Doppler ultrasonography for assessment of rheumatoid synovitis: comparison with dynamic magnetic resonance imaging

Eiji Fukuba; Takeshi Yoshizako; Hajime Kitagaki; Yohko Murakawa; Masahiro Kondo; Nobue Uchida

PURPOSE The aim of this study was to compare the effectiveness of power Doppler ultrasonography (PDUS) with that of dynamic magnetic resonance imaging (MRI) for detecting active synovitis in the hands of rheumatoid arthritis (RA) patients. MATERIALS AND METHODS PDUS and dynamic MRI were performed for a total of 220 finger joints with active RA. Each synovial blood flow by PDUS and dynamic MRI was measured and categorized into four grades. RESULTS Taking dynamic MRI as a reference, PDUS showed a sensitivity of 94%, a specificity of 95%, and an accuracy of 95%. CONCLUSION PDUS is useful for detection of active synovitis in the overall-grade RA patients.


Radiotherapy and Oncology | 2014

Factors influencing survival outcome for radiotherapy for biliary tract cancer: A multicenter retrospective study

Yasuo Yoshioka; Kazuhiko Ogawa; Hirobumi Oikawa; Hiroshi Onishi; Nobue Uchida; Toshiya Maebayashi; Naoto Kanesaka; Tetsuro Tamamoto; Hirofumi Asakura; Takashi Kosugi; Kazuo Hatano; Michio Yoshimura; Kazunari Yamada; Sunao Tokumaru; Kenji Sekiguchi; Masao Kobayashi; Toshinori Soejima; Fumiaki Isohashi; Kenji Nemoto; Yasumasa Nishimura

PURPOSE To seek for the possible factors influencing overall survival (OS) with radiotherapy (RT) for biliary tract cancer. MATERIALS AND METHODS Data were collected retrospectively from RT database of 31 institutions in Japan. All patients underwent at least external beam RT. The factors influencing OS were investigated. RESULTS Data of 498 patients were analyzed. Median OS of the 212 patients who underwent surgery was significantly better than that of the 286 patients without surgery (31 vs. 15 months, p<0.001). The OS for the R0 or R1 resection group was significantly longer than that for the R2 or non-surgery group, as well as for n0 compared to n1 (all p<0.001). Chemoradiotherapy (CRT), both sequential and concurrent, resulted in a better OS than RT alone for the n1 group (31 vs. 13 months, p<0.001), and marginally better for the R0/R1 group (p=0.065; p=0.054 for concurrent CRT). However, no such benefit was observed for the R2/non-surgical patients. Multivariate analysis identified performance status, clinical stage, and surgery as significant factors. CONCLUSION Surgery, especially R0/R1 resection, seemed as the gold standard for treatment of biliary tract cancer including RT, even in the highly heterogeneous population obtained from the multicenter retrospective study. The possibility was shown that CRT yielded better survival benefit especially for n1 patients. We recommend that future prospective trials include an arm of adjuvant CRT at least for n1 and possibly R0/R1 patients.


International Journal of Radiation Oncology Biology Physics | 2010

Patterns of Radiotherapy Practice for Pancreatic Cancer in Japan: Results of the Japanese Radiation Oncology Study Group (JROSG) Survey

Kazuhiko Ogawa; Yoshinori Ito; Katsuyuki Karasawa; Yoshihiro Ogawa; Hiroshi Onishi; Tomoko Kazumoto; Keiko Shibuya; Hitoshi Shibuya; Yoshishige Okuno; Shigeo Nishino; Etsuyo Ogo; Nobue Uchida; Kumiko Karasawa; Kenji Nemoto; Yasumasa Nishimura

PURPOSE To determine the patterns of radiotherapy practice for pancreatic cancer in Japan. METHODS AND MATERIALS A questionnaire-based national survey of radiotherapy for pancreatic cancer treated between 2000 and 2006 was conducted by the Japanese Radiation Oncology Study Group (JROSG). Detailed information on 870 patients from 34 radiation oncology institutions was accumulated. RESULTS The median age of all patients was 64 years (range, 36-88), and 80.2% of the patients had good performance status. More than 85% of patients had clinical Stage T3-T4 disease, and 68.9% of patients had unresectable disease at diagnosis. Concerning radiotherapy (RT), 49.8% of patients were treated with radical external beam RT (EBRT) (median dose, 50.4 Gy), 44.4% of patients were treated with intraoperative RT (median dose, 25 Gy) with or without EBRT (median dose, 45 Gy), and 5.9% of patients were treated with postoperative radiotherapy (median dose, 50 Gy). The treatment field consisted of the primary tumor (bed) only in 55.6% of the patients. Computed tomography-based treatment planning and conformal RT was used in 93.1% and 83.1% of the patients treated with EBRT, respectively. Chemotherapy was used for 691 patients (79.4%; before RT for 66 patients; during RT for 531; and after RT for 364). Gemcitabine was the most frequently used drug, followed by 5-fluorouracil. CONCLUSION This study describes the general patterns of RT practice for pancreatic cancer in Japan. Most patients had advanced unresectable disease, and radical EBRT, as well as intraoperative RT with or without EBRT, was frequently used. Chemotherapy with gemcitabine was commonly used in conjunction with RT during the survey period.


Brain & Development | 2005

Brain stem glioblastoma with multiple large cyst formation and leptomeningeal dissemination in a 4-year-old girl

Rie Kanai; Masaru Tasaka; Hitoshi Sejima; Nobue Uchida; Akinobu Nakano; Yasuhiko Akiyama; Toshiki Yamasaki; Seiji Yamaguchi

The authors report a 4-year-old girl who developed brain stem glioblastoma. Meningeal irritation was present at onset. Magnetic resonance imaging revealed intracranial and intraspinal leptomeningeal dissemination, which progressed faster than the original tumor. Multiple large cysts developed at the interhemispheric and prepontine cisterns, resulting in progressive obstructive hydrocephalus. The patient survived only 5 months after presentation. Histology was verified by autopsy.


International Journal of Clinical Oncology | 2007

Role of 10-Gy boost radiation after breast-conserving surgery for stage I–II breast cancer with a 5-mm negative margin

Masafumi Notani; Nobue Uchida; Hajime Kitagaki

BackgroundAccording to the Guidelines for breast-conserving therapy of the Japanese Breast Cancer Society, the surgical margin is “negative” when the minimum distance between the tumor edge and the margin of the resected specimen is more than 5 mm. The value of boost radiation for early breast cancer with a 5-mm negative margin remains unclear.MethodsA total of 137 patients with stage I–II breast cancer underwent breast-conserving surgery between July 1987 and August 2002. All of the patients had negative margins according to the Japanese guidelines. Their median age was 50 years and the median follow-up period was 62 months. The entire ipsilateral breast was irradiated to a total dose of 50 Gy (25 fractions). Then an additional 10 Gy (5 fractions) was given to 79 patients, using 6- to 12-MeV electrons (boost group), while 58 patients (no-boost group) received no further radiation. Factors influencing local recurrence were evaluated by univariate and multivariate analyses.ResultsFor the entire population, the 5-year overall survival, cause-specific survival, disease-free survival, and local recurrence rates were 96.0%, 96.8%, 94.2%, and 1.67%, respectively. Boost radiation reduced local recurrence, but the improvement was not significant (P = 0.070). Univariate and multivariate analyses failed to detect any factors that were significantly associated with local control. There were no severe complications in either group and there were no differences between the groups in the cosmetic outcome.ConclusionBoost radiation can be performed for stage I-II breast cancer with negative margins (Japanese guidelines), and showed a tendency to decrease local recurrence. A large randomized controlled study is necessary to establish final conclusions.


Journal of Applied Clinical Medical Physics | 2015

Usefulness of direct-conversion flat-panel detector system as a quality assurance tool for high-dose-rate 192Ir source.

Y. Miyahara; Hajime Kitagaki; T. Nishimura; Kanae Itakura; S. Takahashi; Masaki Yokokawa; Nobue Uchida; Taisuke Inomata

The routine quality assurance (QA) procedure for a high‐dose‐rate (HDR) 192Ir radioactive source is an important task to provide appropriate brachytherapy. Traditionally, it has been difficult to obtain good quality images using the 192Ir source due to irradiation from the high‐energy gamma rays. However, a direct‐conversion flat‐panel detector (d‐FPD) has made it possible to confirm the localization and configuration of the 192Ir source. The purpose of the present study was to evaluate positional and temporal accuracy of the 192Ir source using a d‐FPD system, and the usefulness of d‐FPD as a QA tool. As a weekly verification of source positional accuracy test, we obtained 192Ir core imaging by single‐shot radiography for three different positions (1300/1400/1500 mm) of a check ruler. To acquire images for measurement of the 192Ir source movement distance with varying interval steps (2.5/5.0/10.0 mm) and temporal accuracy, we used the high‐speed image acquisition technique and digital subtraction. For accuracy of the 192Ir source dwell time, sequential images were obtained using various dwell times ranging from 0.5 to 30.0 sec, and the acquired number of image frames was assessed. Analysis of the data was performed using the measurement analysis function of the d‐FPD system. Although there were slight weekly variations in source positional accuracy, the measured positional errors were less than 1.0 mm. For source temporal accuracy, the temporal errors were less than 1.0%, and the correlation between acquired frames and programmed time showed excellent linearity (R2=1). All 192Ir core images were acquired clearly without image halation, and the data were obtained quantitatively. All data were successfully stored in the picture archiving and communication system (PACS) for time‐series analysis. The d‐FPD is considered useful as the QA tool for the 192Ir source. PACS number: 87.56.FcThe routine quality assurance (QA) procedure for a high-dose-rate (HDR) 192Ir radioactive source is an important task to provide appropriate brachytherapy. Traditionally, it has been difficult to obtain good quality images using the 192Ir source due to irradiation from the high-energy gamma rays. However, a direct-conversion flat-panel detector (d-FPD) has made it possible to confirm the localization and configuration of the 192Ir source. The purpose of the present study was to evaluate positional and temporal accuracy of the 192Ir source using a d-FPD system, and the usefulness of d-FPD as a QA tool. As a weekly verification of source positional accuracy test, we obtained 192Ir core imaging by single-shot radiography for three different positions (1300/1400/1500 mm) of a check ruler. To acquire images for measurement of the 192Ir source movement distance with varying interval steps (2.5/5.0/10.0 mm) and temporal accuracy, we used the high-speed image acquisition technique and digital subtraction. For accuracy of the 192Ir source dwell time, sequential images were obtained using various dwell times ranging from 0.5 to 30.0 sec, and the acquired number of image frames was assessed. Analysis of the data was performed using the measurement analysis function of the d-FPD system. Although there were slight weekly variations in source positional accuracy, the measured positional errors were less than 1.0 mm. For source temporal accuracy, the temporal errors were less than 1.0%, and the correlation between acquired frames and programmed time showed excellent linearity (R2=1). All 192Ir core images were acquired clearly without image halation, and the data were obtained quantitatively. All data were successfully stored in the picture archiving and communication system (PACS) for time-series analysis. The d-FPD is considered useful as the QA tool for the 192Ir source. PACS number: 87.56.Fc.

Collaboration


Dive into the Nobue Uchida's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Toshifumi Kasai

Kyoto College of Medical Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Naoto Kanesaka

Tokyo Medical University

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge