Noémi Kántor
University of Szeged
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Noémi Kántor.
Central European Journal of Geosciences | 2011
Noémi Kántor; János Unger
This paper gives a review on the topic of the mean radiant temperature Tmrt, the most important parameter influencing outdoor thermal comfort during sunny conditions. Tmrt summarizes all short wave and long wave radiation fluxes reaching the human body, which can be very complex (variable in spatial and also in temporal manner) in urban settings. Thermal comfort researchers and urban planners need easy and sound methodological approaches to assess Tmrt. After the basics of the Tmrt calculation some of the methods suitable for obtaining Tmrt also in urban environments will be presented.. Two of the discussed methods are based on instruments which measure the radiation fluxes integral (globe thermometer, pyranometer-pyrgeometer combination), and three of the methods are based on modelling the radiation environment with PC software (RayMan, ENVI-met and SOLWEIG).
International Journal of Biometeorology | 2012
Noémi Kántor; Lilla Andrea Égerházi; János Unger
During two investigation periods in transient seasons (14 weekdays in autumn 2009 and 15 weekdays in spring 2010) 967 visitors in two inner city squares of Szeged (Hungary) were asked about their estimation of their thermal environment. Interrelationships of subjective assessments—thermal sensation, perceptions and preferences for individual climate parameters—were analyzed, as well as their connections with the prevailing thermal conditions [air temperature, relative humidity, wind velocity, mean radiant temperature and physiologically equivalent temperature (PET)]. Thermal sensation showed strong positive relationships with air temperature and solar radiation perception, while wind velocity and air humidity perception had a negative (and weaker) impact. If a parameter was perceived to be low or weak, then it was usually desired to be higher or stronger. This negative correlation was weakest in the case of humidity. Of the basic meteorological parameters, Hungarians are most sensitive to variations in wind. Above PET = 29°C, people usually prefer lower air temperature and less solar radiation. The temperature values perceived by the interviewees correlated stronger with PET, but their means were more similar to air temperature. It was also found that the mean thermal sensation of Hungarians in transient seasons depends on PET according to a quadratic function (R2 = 0.912) and, consequently, the thermal comfort ranges of the locals differ from that usually adopted.
International Journal of Biometeorology | 2012
Noémi Kántor; János Unger; Ágnes Gulyás
The present paper is the second part of our study in which we compare the results obtained in Szeged (Hungary) with those achieved through earlier outdoor thermal comfort projects based on simultaneous questionnaire surveys and on-site meteorological measurements. The main characteristics of the selected studies—conducted in Hungary, Sweden, Portugal, Canada, Taiwan and across Europe in the frame of project RUROS—are reviewed, emphasizing the common features and also the discrepancies in the applied methodology. We discuss their potential effects on the evolution and interpretation of the results concerning the subjective assessment of the thermal environment. Another aspect of the comparison focuses on the regional climatic differences naturally ensuing from the various locations, which left their marks on the results related to both physiological acclimatization and mental adaptation. The compared results of different studies include correlation coefficients expressing interrelationships between the different aspects of subjective estimations (thermal sensation, perceptions, preferences) and also between subjective assessments and the corresponding meteorological parameters. We compare neutral temperatures (expressed in physiological equivalent temperature, PET) which arose for Taiwan and Hungary, as well as thermal sensation zones for local inhabitants. Subjectively assessed temperature values of Sweden and Hungarians are analyzed according to the measured air temperature. According to our experiences the methodology should be standardized for the level of field surveys and also for the level of data processing in order to make the data collected in different locations comparable.
International Journal of Biometeorology | 2014
Chien Hung Tung; Chen Peng Chen; Kang Ting Tsai; Noémi Kántor; Ruey Lung Hwang; Andreas Matzarakis; Tzu Ping Lin
Thermal comfort is a subjective psychological perception of people based also on physiological thermoregulation mechanisms when the human body is exposed to a combination of various environmental factors including air temperature, air humidity, wind speed, and radiation conditions. Due to the importance of gender in the issue of outdoor thermal comfort, this study compared and examined the thermal comfort-related differences between male and female subjects using previous data from Taiwanese questionnaire survey. Compared with males, the results indicated that females in Taiwan are less tolerant to hot conditions and intensely protect themselves from sun exposure. Our analytical results are inconsistent with the findings of previous physiological studies concerning thermal comfort indicating that females have superior thermal physiological tolerance than males. On the contrary, our findings can be interpreted on psychological level. Environmental behavioral learning theory was adopted in this study to elucidate this observed contradiction between the autonomic thermal physiological and psychological–behavioral aspects. Women might desire for a light skin tone through social learning processes, such as observation and education, which is subsequently reflected in their psychological perceptions (fears of heat and sun exposure) and behavioral adjustments (carrying umbrellas or searching for shade). Hence, these unique psychological and behavioral phenomena cannot be directly explained by autonomic physiological thermoregulation mechanisms. The findings of this study serve as a reference for designing spaces that accommodates gender-specific thermal comfort characteristics. Recommendations include providing additional suitable sheltered areas in open areas, such as city squares and parks, to satisfy the thermal comfort needs of females.
Theoretical and Applied Climatology | 2016
Attila Kovács; János Unger; Csilla Gál; Noémi Kántor
This study introduces new methodological concepts for integrating seasonal subjective thermal assessment patterns of people into the thermal components of two tourism climatological evaluation tools: the Tourism Climatic Index (TCI) and the Climate-Tourism/Transfer-Information-Scheme (CTIS). In the case of the TCI, we replaced the air temperature and relative humidity as the basis of the initial rating system with the physiologically equivalent temperature (PET)—a complex human biometeorological index. This modification improves the TCI’s potential to evaluate the thermal aspects of climate. The major accomplishments of this study are (a) the development of a new, PET-based rating system and its integration into the thermal sub-indices of the TCI and (b) the regionalization of the thermal components of CTIS to reflect both the thermal sensation and preference patterns of people. A 2-year-long (2011–2012) thermal comfort survey conducted in Szeged, Hungary, from spring to autumn was utilized to demonstrate the implementation of the introduced concepts. We found considerable differences between the thermal perception and preference patterns of Hungarians, with additional variations across the evaluated seasons. This paper describes the proposed methodology for the integration of the new seasonal, perception-based, and preference-based PET rating systems into the TCI, and presents the incorporation of new PET thresholds into the CTIS. In order to demonstrate the utility of the modified evaluation tools, we performed case study climate analyses for three Hungarian tourist destinations. The additional adjustments introduced during the course of those analyses include the reduction of TCI’s temporal resolution to 10-day intervals and the exclusion of nocturnal and winter periods from the investigation.
International Review of Applied Sciences and Engineering | 2013
Lilla Andrea Égerházi; Noémi Kántor; Tamás Mátyás Gál
Abstract This paper presents a thermal comfort study of a popular playground in Szeged, Hungary in order to find its optimal land cover and vegetation options. For this assessment simulated micro- and bioclimatological conditions recorded on a typical summer day (12th July 2011) were analysed. The thermal and radiation features of the study area were quantified by two biometeorological indices, Predicted Mean Vote (PMV) and Mean Radiant Temperature (Tmrt). For the simulation of the meteorological parameters and the bioclimate indices, ENVI-met microclimate model was used. The results confirmed that the modelled areas with different land cover provide a variety of thermal conditions for the visitors; moreover, human thermal sensation was significantly affected by the change of the radiation environment.
Open Geosciences | 2016
Noémi Kántor; Attila Kovács; Ágnes Takács
Abstract This study provides evidences on the beneficial small-scale human-biometeorological effects of a large shade tree during the daytime in summer. We carried out detailed measurement from 10 am to 6 pm with two human-biometeorological stations on a popular square in Szeged, Hungary. One of the stations stood under a great Sophora japonica, while the other in the sun. Compared to the sunny location, we found 0.5°C lower air temperature, 2% higher relative humidity and 0.4 hPa higher vapor pressure under the tree. From human-biometeorological point of view, we observed more significant differences. The tree reduced the mean radiant temperature by 22.1°C and the physiological equivalent temperature by 9.3°C - indicating about two categories lower physiological stress on the human body. In order to demonstrate the background mechanisms of these differences, we analyzed separately the components of the radiation budget. The effect of tree crown on radiation components was found to be greater in the short-wave domain than in the long-wave domain. The extended foliage reduced the solar radiation from the upper hemisphere and thus lowered the radiation from the ground (the reflected short-wave and the emitted longwave flux densities) along with the radiation from the lateral directions.
Advances in Meteorology | 2018
Noémi Kántor; Csilla Gál; Ágnes Gulyás; János Unger
Increasing summertime air temperature deteriorates human health especially in cities where the warming tendency is exacerbated by urban heat island. Human-biometeorological studies shed light on th ...
Environmental Science and Pollution Research | 2017
Süleyman Toy; Noémi Kántor
Human thermal comfort conditions can be evaluated using various indices based on simple empirical approaches or more complex and reliable human-biometeorological approaches. The latter is based on the energy balance model of the human body, and their calculation is supplemented with computer software. Facilitating the interpretation of results, the generally applied indices express the effects of thermal environment in the well-known temperature unit, just like in the case of the widely used index, the physiologically equivalent temperature (PET). Several studies adopting PET index for characterizing thermal components of climate preferred to organize the resulted PET values into thermal sensation categories in order to demonstrate the spatial and/or temporal characteristics of human thermal comfort conditions. The most general applied PET ranges were derived by Central European researchers, and they are valid for assumed values of internal heat production of light activity and thermal resistance of clothing representing a light business suit. Based on the example of Erzurum city, the present work demonstrates that in a city with harsh winter, the original PET ranges show almost purely discomfort and they seem to be less applicable regarding cold climate conditions. Taking into account 34-year climate data of Erzurum, the annual distribution of PET is presented together with the impact of application of different PET categorization systems, including 8°- and 7°-wide PET intervals. The demonstrated prior analyses lack any questionnaire filed surveys in Erzurum. Thus, as a next step, detailed field investigations would be required with the aim of definition of new PET categorization systems which are relevant for local residents who are adapted to this climatic background, and for tourists who may perform various kinds of winter activities in Erzurum and therefore may perceive the thermal environment more comfortable.
Landscape and Urban Planning | 2010
Noémi Kántor; János Unger