Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Norbert Orgovan is active.

Publication


Featured researches published by Norbert Orgovan.


Scientific Reports | 2015

Dependence of cancer cell adhesion kinetics on integrin ligand surface density measured by a high-throughput label-free resonant waveguide grating biosensor

Norbert Orgovan; Beatrix Peter; Szilvia Bősze; Jeremy J. Ramsden; Bálint Szabó; Robert Horvath

A novel high-throughput label-free resonant waveguide grating (RWG) imager biosensor, the Epic® BenchTop (BT), was utilized to determine the dependence of cell spreading kinetics on the average surface density (vRGD) of integrin ligand RGD-motifs. vRGD was tuned over four orders of magnitude by co-adsorbing the biologically inactive PLL-g-PEG and the RGD-functionalized PLL-g-PEG-RGD synthetic copolymers from their mixed solutions onto the sensor surface. Using highly adherent human cervical tumor (HeLa) cells as a model system, cell adhesion kinetic data of unprecedented quality were obtained. Spreading kinetics were fitted with the logistic equation to obtain the spreading rate constant (r) and the maximum biosensor response (Δλmax), which is assumed to be directly proportional to the maximum spread contact area (Amax). r was found to be independent of the surface density of integrin ligands. In contrast, Δλmax increased with increasing RGD surface density until saturation at high densities. Interpreting the latter behavior with a simple kinetic mass action model, a 2D dissociation constant of 1753 ± 243u2005μm−2 (corresponding to a 3D dissociation constant of ~30u2005μM) was obtained for the binding between RGD-specific integrins embedded in the cell membrane and PLL-g-PEG-RGD. All of these results were obtained completely noninvasively without using any labels.


Biosensors and Bioelectronics | 2014

In-situ and label-free optical monitoring of the adhesion and spreading of primary monocytes isolated from human blood: dependence on serum concentration levels.

Norbert Orgovan; Rita Salánki; Noémi Sándor; Zsuzsa Bajtay; Anna Erdei; Bálint Szabó; Robert Horvath

Adhesion and spreading of primary monocytes isolated from human blood were monitored utilizing optical waveguide lightmode spectroscopy (OWLS); a highly sensitive label-free biosensor technique using evanescent optical waves generated at a biocompatible surface. Appropriate development on a custom built setup enabled the OWLS cuvette to be operated as a 1.5 ml mini-incubator, controlling both temperature and CO2 levels. The incubator-equipped OWLS is readily applicable for delicate and long-term studies on sensitive primary cells, demonstrated here through monitoring the serum dependence of the adhesion and spreading of human monocytes. Moreover, the custom-built setup enables the simultaneous monitoring of the position and overall width of the OWLS resonant peaks. This unique feature makes it possible to distinguish the refractive index variations induced by the adsorption of secreted material from refractive index changes provoked by cellular spreading. A definite attachment and spreading activity was observed on the substratum (glassy silica-titania), when the serum level of the culturing medium was 0.0-0.01%. Increasing serum concentration resulted in a steep fall in monocyte surface adhesion and spreading. 1.0% serum level practically abolished all spreading activity measured by OWLS, and the number of attached cells was significantly decreased, too. Serum addition to fully spread cells provoked a reduction in the cell-substratum contact area, clearly detectable by the biosensor. Cell spreading was inhibited by pre-coating the sensor surface with considerable amounts of serum proteins. These findings suggest that monocyte spreading is inhibited by the adsorption of serum biomolecules to the substratum, rather than by soluble factors present in the serum. All of these results were obtained completely noninvasively with real time monitoring; demonstrating the capabilities of OWLS to sensitively monitor the adhesion properties of immune cells isolated from human blood. The current study is, therefore, a significant step towards the application of label-free optical biosensors in medical diagnostics.


Analytical Chemistry | 2013

Optical anisotropy of flagellin layers: In situ and label-free measurement of adsorbed protein orientation using OWLS

Noémi Kovács; Daniel Patko; Norbert Orgovan; Sándor Kurunczi; Jeremy J. Ramsden; Ferenc Vonderviszt; Robert Horvath

The surface adsorption of the protein flagellin was followed in situ using optical waveguide lightmode spectroscopy (OWLS). Flagellin did not show significant adsorption on a hydrophilic waveguide, but very rapidly formed a dense monolayer on a hydrophobic (silanized) surface. The homogeneous and isotropic optical layer model, which has hitherto been generally applied in OWLS data interpretation for adsorbed protein films, failed to characterize the flagellin layer, but it could be successfully modeled as an uniaxial thin film. This anisotropic modeling revealed a significant positive birefringence in the layer, suggesting oriented protein adsorption. The adsorbed flagellin orientation was further evidenced by monitoring the surface adsorption of truncated flagellin variants, in which the terminal protein regions or the central (D3) domain were removed. Without the terminal regions the protein adsorption was much slower and the resulting films were significantly less birefringent, implying that intact flagellin adsorbs on the hydrophobic surface via its terminal regions.


Advances in Colloid and Interface Science | 2014

Sample handling in surface sensitive chemical and biological sensing: a practical review of basic fluidics and analyte transport.

Norbert Orgovan; Daniel Patko; Csaba Hos; Sándor Kurunczi; Bálint Szabó; Jeremy J. Ramsden; Robert Horvath

This paper gives an overview of the advantages and associated caveats of the most common sample handling methods in surface-sensitive chemical and biological sensing. We summarize the basic theoretical and practical considerations one faces when designing and assembling the fluidic part of the sensor devices. The influence of analyte size, the use of closed and flow-through cuvettes, the importance of flow rate, tubing length and diameter, bubble traps, pressure-driven pumping, cuvette dead volumes, and sample injection systems are all discussed. Typical application areas of particular arrangements are also highlighted, such as the monitoring of cellular adhesion, biomolecule adsorption-desorption and ligand-receptor affinity binding. Our work is a practical review in the sense that for every sample handling arrangement considered we present our own experimental data and critically review our experience with the given arrangement. In the experimental part we focus on sample handling in optical waveguide lightmode spectroscopy (OWLS) measurements, but the present study is equally applicable for other biosensing technologies in which an analyte in solution is captured at a surface and its presence is monitored. Explicit attention is given to features that are expected to play an increasingly decisive role in determining the reliability of (bio)chemical sensing measurements, such as analyte transport to the sensor surface; the distorting influence of dead volumes in the fluidic system; and the appropriate sample handling of cell suspensions (e.g. their quasi-simultaneous deposition). At the appropriate places, biological aspects closely related to fluidics (e.g. cellular mechanotransduction, competitive adsorption, blood flow in veins) are also discussed, particularly with regard to their models used in biosensing.


Applied Physics Letters | 2014

Bulk and surface sensitivity of a resonant waveguide grating imager

Norbert Orgovan; Boglarka Kovacs; Eniko Farkas; Bálint Szabó; Natalya Zaytseva; Ye Fang; Robert Horvath

We report the assessment of the sensitivity of a microplate-compatible resonant waveguide grating imager. The sensitivity to bulk refractive index changes was determined using a serial dilution of glycerol solution with the help of a refractometer. The surface sensitivity was examined using layer-by-layer polyelectrolyte films in conjunction with optical waveguide lightmode spectroscopy and characterized by the binding of acetazolamide to immobilized carbonic anhydrase under microfluidics. The results suggest that the imager has a limit of detection down to 2.2 × 10−6 for refractive index change and 0.078u2009ng/cm2 for the adsorbed mass.


Scientific Reports | 2016

Intensity interrogation near cutoff resonance for label-free cellular profiling

Yousef Nazirizadeh; Volker Behrends; Aurél Prósz; Norbert Orgovan; Robert Horvath; Ann M. Ferrie; Ye Fang; Christine Selhuber-Unkel; Martina Gerken

We report a method enabling intensity-based readout for label-free cellular assays, and realize a reader device with the same footprint as a microtiter plate. For unambiguous resonance intensity measurements in resonance waveguide grating (RWG) sensors, we propose to apply resonances near the substrate cutoff wavelength. This method was validated in bulk refractive index, surface bilayer and G protein-coupled receptor (GPCR) experiments. The significantly reduced size of the reader device opens new opportunities for easy integration into incubators or liquid handling systems.


Scientific Reports | 2016

Automated single cell isolation from suspension with computer vision

Rita Ungai-Salánki; Tamás Gerecsei; P. Fürjes; Norbert Orgovan; Noémi Sándor; Eszter Gabriella Holczer; Robert Horvath; Bálint Szabó

Current robots can manipulate only surface-attached cells seriously limiting the fields of their application for single cell handling. We developed a computer vision-based robot applying a motorized microscope and micropipette to recognize and gently isolate intact individual cells for subsequent analysis, e.g., DNA/RNA sequencing in 1–2 nanoliters from a thin (~100u2009μm) layer of cell suspension. It can retrieve rare cells, needs minimal sample preparation, and can be applied for virtually any tissue cell type. Combination of 1u2009μm positioning precision, adaptive cell targeting and below 1u2009nl liquid handling precision resulted in an unprecedented accuracy and efficiency in robotic single cell isolation. Single cells were injected either into the wells of a miniature plate with a sorting speed of 3 cells/min or into standard PCR tubes with 2 cells/min. We could isolate labeled cells also from dense cultures containing ~1,000 times more unlabeled cells by the successive application of the sorting process. We compared the efficiency of our method to that of single cell entrapment in microwells and subsequent sorting with the automated micropipette: the recovery rate of single cells was greatly improved.


PLOS ONE | 2016

CD11c/CD18 Dominates Adhesion of Human Monocytes, Macrophages and Dendritic Cells over CD11b/CD18

Noémi Sándor; Szilvia Lukácsi; Rita Ungai-Salánki; Norbert Orgovan; Bálint Szabó; Robert Horvath; Anna Erdei; Zsuzsa Bajtay

Complement receptors CR3 (CD11b/CD18) and CR4 (CD11c/CD18) belong to the family of beta2 integrins and are expressed mainly by myeloid cell types in humans. Previously, we proved that CR3 rather than CR4 plays a key role in phagocytosis. Here we analysed how CD11b and CD11c participate in cell adhesion to fibrinogen, a common ligand of CR3 and CR4, employing human monocytes, monocyte-derived macrophages (MDMs) and monocyte-derived dendritic cells (MDDCs) highly expressing CD11b as well as CD11c. We determined the exact numbers of CD11b and CD11c on these cell types by a bead-based technique, and found that the ratio of CD11b/CD11c is 1.2 for MDDCs, 1.7 for MDMs and 7.1 for monocytes, suggesting that the function of CD11c is preponderant in MDDCs and less pronounced in monocytes. Applying state-of-the-art biophysical techniques, we proved that cellular adherence to fibrinogen is dominated by CD11c. Furthermore, we found that blocking CD11b significantly enhances the attachment of MDDCs and MDMs to fibrinogen, demonstrating a competition between CD11b and CD11c for this ligand. On the basis of the cell surface receptor numbers and the measured adhesion strength we set up a model, which explains the different behavior of the three cell types.


PLOS ONE | 2014

Single cell adhesion assay using computer controlled micropipette.

Rita Salánki; Csaba Hős; Norbert Orgovan; Beatrix Peter; Noémi Sándor; Zsuzsa Bajtay; Anna Erdei; Robert Horvath; Bálint Szabó

Cell adhesion is a fundamental phenomenon vital for all multicellular organisms. Recognition of and adhesion to specific macromolecules is a crucial task of leukocytes to initiate the immune response. To gain statistically reliable information of cell adhesion, large numbers of cells should be measured. However, direct measurement of the adhesion force of single cells is still challenging and today’s techniques typically have an extremely low throughput (5–10 cells per day). Here, we introduce a computer controlled micropipette mounted onto a normal inverted microscope for probing single cell interactions with specific macromolecules. We calculated the estimated hydrodynamic lifting force acting on target cells by the numerical simulation of the flow at the micropipette tip. The adhesion force of surface attached cells could be accurately probed by repeating the pick-up process with increasing vacuum applied in the pipette positioned above the cell under investigation. Using the introduced methodology hundreds of cells adhered to specific macromolecules were measured one by one in a relatively short period of time (∼30 min). We blocked nonspecific cell adhesion by the protein non-adhesive PLL-g-PEG polymer. We found that human primary monocytes are less adherent to fibrinogen than their in vitro differentiated descendants: macrophages and dendritic cells, the latter producing the highest average adhesion force. Validation of the here introduced method was achieved by the hydrostatic step-pressure micropipette manipulation technique. Additionally the result was reinforced in standard microfluidic shear stress channels. Nevertheless, automated micropipette gave higher sensitivity and less side-effect than the shear stress channel. Using our technique, the probed single cells can be easily picked up and further investigated by other techniques; a definite advantage of the computer controlled micropipette. Our experiments revealed the existence of a sub-population of strongly fibrinogen adherent cells appearing in macrophages and highly represented in dendritic cells, but not observed in monocytes.


Scientific Reports | 2017

Antibiotic-induced release of small extracellular vesicles (exosomes) with surface-associated DNA

Andrea Németh; Norbert Orgovan; Barbara Sódar; Xabier Osteikoetxea; Krisztina Pálóczi; Katalin Szabó-Taylor; Krisztina V. Vukman; Ágnes Kittel; Lilla Turiák; Zoltán Wiener; Sára Tóth; László Drahos; Károly Vékey; Robert Horvath; Edit I. Buzás

Recently, biological roles of extracellular vesicles (which include among others exosomes, microvesicles and apoptotic bodies) have attracted substantial attention in various fields of biomedicine. Here we investigated the impact of sustained exposure of cells to the fluoroquinolone antibiotic ciprofloxacin on the released extracellular vesicles. Ciprofloxacin is widely used in humans against bacterial infections as well as in cell cultures against Mycoplasma contamination. However, ciprofloxacin is an inducer of oxidative stress and mitochondrial dysfunction of mammalian cells. Unexpectedly, here we found that ciprofloxacin induced the release of both DNA (mitochondrial and chromosomal sequences) and DNA-binding proteins on the exofacial surfaces of small extracellular vesicles referred to in this paper as exosomes. Furthermore, a label-free optical biosensor analysis revealed DNA-dependent binding of exosomes to fibronectin. DNA release on the surface of exosomes was not affected any further by cellular activation or apoptosis induction. Our results reveal for the first time that prolonged low-dose ciprofloxacin exposure leads to the release of DNA associated with the external surface of exosomes.

Collaboration


Dive into the Norbert Orgovan's collaboration.

Top Co-Authors

Avatar

Robert Horvath

Hungarian Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Bálint Szabó

Eötvös Loránd University

View shared research outputs
Top Co-Authors

Avatar

Noémi Sándor

Eötvös Loránd University

View shared research outputs
Top Co-Authors

Avatar

Anna Erdei

Eötvös Loránd University

View shared research outputs
Top Co-Authors

Avatar

Zsuzsa Bajtay

Hungarian Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Beatrix Peter

Hungarian Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Szilvia Bősze

Eötvös Loránd University

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge