Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Noriko Tsuda is active.

Publication


Featured researches published by Noriko Tsuda.


Circulation | 2015

Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera

Shinya Shiraishi; Fumi Sakamoto; Noriko Tsuda; Morikatsu Yoshida; Seiji Tomiguchi; Daisuke Utsunomiya; Hisao Ogawa; Yasuyuki Yamashita

BACKGROUND Myocardial perfusion imaging (MPI) may fail to detect balanced ischemia. We evaluated myocardial perfusion reserve (MPR) using Tl dynamic single-photon emission computed tomography (SPECT) and a novel cadmium zinc telluride (CZT) camera for predicting 3-vessel or left main coronary artery disease (CAD). METHODS AND RESULTS: A total of 55 consecutive patients with suspected CAD underwent SPECT-MPI and coronary angiography. The MPR index was calculated using the standard 2-compartment kinetic model. We analyzed the utility of MPR index, other SPECT findings, and various clinical variables. On multivariate analysis, MPR index and history of previous myocardial infarction (MI) predicted left main and 3-vessel disease. The area under the receiver operating characteristic curve was 0.81 for MPR index, 0.699 for history of previous MI, and 0.86 for MPR index plus history of previous MI. MPR index ≤1.5 yielded the highest diagnostic accuracy. Sensitivity, specificity, and accuracy were 86%, 78%, and 80%, respectively, for MPR index, 64%, 76%, 73% for previous MI, and 57%, 93%, and 84% for MPR index plus history of previous MI. CONCLUSIONS Quantification of MPR using dynamic SPECT and a novel CZT camera may identify balanced ischemia in patients with left main or 3-vessel disease.


Annals of Translational Medicine | 2015

99m Tc-GSA SPECT/CT fused images for assessment of hepatic function and hepatectomy planning

Morikatsu Yoshida; Toru Beppu; Shinya Shiraishi; Noriko Tsuda; Fumi Sakamoto; Hirohisa Okabe; Hiromitsu Hayashi; Hideo Baba; Yasuyuki Yamashita

To assure safe hepatectomy, accurate estimation of the functional reserve of the future remnant liver is crucial. The combination of indocyanine green retention rate at 15 min and CT volumetry is widely used in deciding on the extent of hepatectomy. On the other hand, there are quantitative indices calculated from (99m)Tc-GSA scintigraphy that reflect the number and function of hepatocytes. Therefore, there are many indices calculated from (99m)Tc-GSA scintigraphy that have been reported. In recent Annals of Surgical Oncology on Oct. 2014 the Uptake Index (UI) calculated from (99m)Tc-GSA scintigraphy was reported to be useful for hepatectomy planning and postoperative liver failure prediction. In this paper, we report on the usefulness and limits of quantitative indices calculated from (99m)Tc-GSA SPECT/CT for preoperative simulation.


British Journal of Radiology | 2016

123I-MIBG myocardial scintigraphy for the evaluation of Lewy body disease: are delayed images essential? Is visual assessment useful?

Fumi Sakamoto; Shinya Shiraishi; Noriko Tsuda; Koji Ogasawara; Morikatsu Yoshida; Hideaki Yuki; Mamoru Hashimoto; Seiji Tomiguchi; Manabu Ikeda; Yasuyuki Yamashita

OBJECTIVE: We performed 123I-meta-iodobenzylguanidine (123I-MIBG) myocardial scintigraphy for the diagnosis of Lewy body disease (LBD) and assessed whether the early heart-to-mediastinum (H/M) ratio was diagnostic and whether visual image analysis was useful. METHODS: Our study included 453 patients with clinically suspected LBD who had undergone 123I-MIBG myocardial scintigraphy. We evaluated semi-quantitative values (early and delayed H/M ratio, washout rate) and performed visual image analysis. The sensitivity, specificity, accuracy, positive-predictive value (PPV) and negative-predictive value (NPV) of both analyses were calculated. RESULTS: The early H/M ratio exhibited the best diagnostic ability. Its overall sensitivity, specificity, accuracy, PPV and NPV were 72.2%, 93.1%, 84.3%, 88.5% and 82.2%, respectively (cut-off value 2.2 or less). However, there was no significant difference from the delayed H/M ratio or the results of visual assessment. CONCLUSION: 123I-MIBG myocardial scintigraphy accurately differentiates between patients with and without LBD and a correct diagnosis can be established based on the early H/M ratio. We also document that visual evaluation of scintigrams is useful. Therefore, patients may benefit from the single performance of the procedure because a correct diagnosis can be obtained early in the disease process and their prognosis and appropriate treatment can be determined. ADVANCES IN KNOWLEDGE: 123I-MIBG myocardial scintigraphy on the early H/M ratio makes it possible to differentiate between patients with LBD and patients without LBD.


British Journal of Radiology | 2017

Diagnosis of dementia with Lewy bodies: Can 123I-IMP and 123I-MIBG scintigraphy yield new core features?

Fumi Sakamoto; Shinya Shiraishi; Noriko Tsuda; Mamoru Hashimoto; Seiji Tomiguchi; Manabu Ikeda; Yasuyuki Yamashita

OBJECTIVE Since the clinical symptoms of different types of dementia frequently overlap, especially in the earlier stages at onset, it is difficult to distinguish dementia with Lewy bodies (DLB) from other neurodegenerative dementias based on their clinical manifestations alone. Nuclear medicine imaging has been reported as a high-value index for the objective evaluation and diagnosis of DLB. The aim of this study was to evaluate whether nuclear medicine imaging findings may yield core features to be added to the diagnosis of DLB. METHODS We enrolled 332 patients with suspected DLB. All were evaluated by both 123I-metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy and 123I-labelled N-isopropyl-p-iodoamphetamine (123I-IMP). brain perfusion single-photon emission CT. The final clinical diagnosis indicated probable DLB in 92 patients (40 males, 52 females; mean age ± standard deviation, 77.4 ± 6.4 years; range, 56-89 years); 240 patients (98 males, 142 females; mean age, 75.5 ± 9.0 years; range, 70-87 years) were recorded as being without DLB. The accepted core features used for clinical evaluations were fluctuating cognition, visual hallucinations and Parkinsonism. The nuclear medicine evaluation indices were the severity score of cerebral blood flow on 123I-IMP scintigraphs of the posterior cingulate and praecuneus and a reduction in the blood flow in the occipital lobe. For 123I-MIBG evaluation, we recorded the early and delayed heart-to-mediastinum (H/M) ratios and the washout rate. RESULTS Univariate and multivariate analyses of fluctuating cognition, visual hallucinations, Parkinsonism and early H/M ratio in patients with probable and without DLB revealed significant differences. Parameters based on 123I-IMP studies did not show any significant differences by multivariate analysis. The area under the curve for the early H/M ratio was 0.918; for fluctuating cognition, visual hallucinations and Parkinsonism, it was 0.693, 0.760 and 0.611, respectively, by receiver-operating characteristic analysis. The early H/M ratio of <2.0 on 123I-MIBG scintigraphs was of the highest diagnostic accuracy. The sensitivity, specificity and accuracy for the diagnosis of probable DLB were 82.4%, 96.3% and 92.5%, respectively. CONCLUSION The early H/M ratio obtained by 123I-MIBG myocardial scintigraphy can serve as a reliable diagnostic index for the core clinical features of DLB. It can be used for the early diagnosis and treatment of DLB. Advances in knowledge: 123I-MIBG myocardial scintigraphy performed at the initial clinical examination can facilitate the early identification or exclusion of DLB and the early H/M ratio may be a diagnostic biomarker for DLB.


Journal of Cardiology | 2018

Quantification of myocardial perfusion reserve using dynamic SPECT images of patients with chronic kidney disease

Noriko Tsuda; Shinya Shiraishi; Fumi Sakamoto; Hideaki Yuki; Koji Ogasawara; Morikatsu Yoshida; Seiji Tomiguchi; Kenichi Tsujita; Yasuyuki Yamashita

BACKGROUND Chronic kidney disease (CKD) is an independent risk factor for cardiovascular disorders. The aim of this study was to examine whether the quantitatively measured myocardial blood flow (MBF) or myocardial perfusion reserve (MPR), calculated by dynamic single photon emission computed tomography (SPECT) analysis using a cardiac cadmium zinc telluride (CZT) gamma camera, was related to renal dysfunction in patients with normal myocardial perfusion imaging (MPI) findings. METHODS The study population consisted of 46 patients with CKD and 46 individuals without CKD (controls). Their MPR index was quantitatively measured using adenosine MPI with a cardiac CZT gamma camera. All assessments were with a single tissue compartment kinetic model. The K1 value was calculated on stress and at-rest images. To obtain the MPR index we divided K1 stress-by K1 at-rest values. RESULTS The at-rest K1 value was significantly higher and the MPR index was significantly lower in patients with CKD than those without CKD [CKD vs. CONTROLS at-rest K1 value, 0.21 (0.17-0.25) vs. 0.19 (0.16-0.22), p=0.040; MPR index, 1.86 (1.69-2.22) vs. 2.19 (1.93-2.41), p<0.001]. The stress K1 values were not significantly different. CONCLUSION The MPR index is significantly lower in CKD patients; this is considered as being mainly due to an increase in the at-rest K1 value.


European Journal of Radiology | 2018

3D hybrid profile order technique in a single breath-hold 3D T2-weighted fast spin-echo sequence: Usefulness in diagnosis of small liver lesions

Kenichiro Hirata; Takeshi Nakaura; Tomoyuki Okuaki; Noriko Tsuda; Narumi Taguchi; Seitaro Oda; Daisuke Utsunomiya; Yasuyuki Yamashita

PURPOSE We compared the efficacy of three-dimensional (3D) isotropic T2-weighted fast spin-echo imaging using a 3D hybrid profile order technique with a single-breath-hold (3D-Hybrid BH) with a two-dimensional (2D) T2-weighted fast spin-echo conventional respiratory-gated (2D-Conventional RG) technique for visualising small liver lesions. MATERIALS AND METHODS This study was approved by our institutional review board. The requirement to obtain written informed consent was waived. Fifty patients with small (≤15mm) hepatocellular carcinomas (HCC) (n=26), or benign cysts (n=24), had undergone hepatic MRI including both 2D-Conventional RG and 3D-Hybrid BH. We calculated the signal-to-noise ratio (SNR) and tumour-to-liver contrast (TLC). The diagnostic performance of the two protocols was analysed. RESULTS The image acquisition time was 89% shorter with the 3D-Hybrid BH than with 2D-Conventional RG. There was no significant difference in the SNR between the two protocols. The area under the curve (AUC) of the TLC was significantly higher on 3D-Hybrid BH than on 2D-Conventional RG. CONCLUSION The 3D-Hybrid BH sequence significantly improved diagnostic performance for small liver lesions with a shorter image acquisition time without sacrificing accuracy.


Circulation | 2017

Utility of Single-Photon Emission Computed Tomography/Computed Tomography Fusion Imaging With 99 m Tc-Pyrophosphate Scintigraphy in the Assessment of Cardiac Transthyretin Amyloidosis

Noriko Tsuda; Shinya Shiraishi; Seitaro Oda; Koji Ogasawara; Fumi Sakamoto; Seiji Tomiguchi; Koichiro Fujisue; Seiji Takashio; Yasuhiro Izumiya; Kenichi Tsujita; Yukio Ando; Yasuyuki Yamashita

tium-99 m-pyrophosphate (99 mTc-PYP) has been shown to have high diagnostic performance in the differentiation of cardiac ATTR from non-ATTR heart failure.2,3 A 52-year-old woman with heart failure was admitted to hospital. On 99 mTc-PYP scintigraphy to assess for cardiac C ardiac transthyretin amyloidosis (ATTR) is increasingly recognized as an important cause of heart failure with preserved ejection fraction, and a growing public health problem with an increasing prevalence.1 Cardiac uptake on bone scintigraphy with techne-


Chinese Journal of Cancer Research | 2014

Quantitative index calculated by 99m Tc-GSA scintigraphy

Morikatsu Yoshida; Shinya Shiraishi; Noriko Tsuda; Fumi Sakamoto; Seiji Tomiguchi; Yasuyuki Yamashita

(99m)Tc-galactosyl human serum albumin (GSA) scintigraphy is useful to evaluate hepatic function and hepatic functional reserve. A reliable SPECT and CT integrated system is now commercially available. Using this system, we can obtain (99m)Tc-GSA SPECT/CT fused imaging with a small registration error. Therefore, the (99m)Tc-GSA scintigraphy techniques prove more useful in clinical practice than have been previously reported. In the latest Annals of Surgical Oncology on Oct 2014, the uptake index (UI) values calculated from (99m)Tc-GSA scintigraphy are reported to be useful for predicting the functional reserve of the future remnant liver. In this paper, we describe the usefulness of (99m)Tc-GSA scintigraphy as well as some cautions that are necessary as regards using the system.


European Radiology | 2017

Cardiovascular magnetic resonance myocardial T1 mapping to detect and quantify cardiac involvement in familial amyloid polyneuropathy

Seitaro Oda; Daisuke Utsunomiya; Kosuke Morita; Takeshi Nakaura; Hideaki Yuki; Masafumi Kidoh; Kenichiro Hirata; Narumi Taguchi; Noriko Tsuda; Shinya Shiraishi; Tomohiro Namimoto; Kyoko Hirakawa; Seiji Takashio; Yasuhiro Izumiya; Megumi Yamamuro; Seiji Hokimoto; Kenichi Tsujita; Mitsuharu Ueda; Taro Yamashita; Yukio Ando; Yasuyuki Yamashita


Anticancer Research | 2018

Dose–function Histogram Evaluation Using 99mTc-GSA SPECT/CT Images for Stereotactic Body Radiation Therapy Planning for Hepatocellular Carcinoma Patients: A Dosimetric Parameter Comparison

Ryo Toya; Tetsuo Saito; Shinya Shiraishi; Yudai Kai; Ryuji Murakami; Tomohiko Matsuyama; Takahiro Watakabe; Fumi Sakamoto; Noriko Tsuda; Yoshinobu Shimohigashi; Yasuyuki Yamashita; Natsuo Oya

Collaboration


Dive into the Noriko Tsuda's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge