Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Norliza Ibrahim is active.

Publication


Featured researches published by Norliza Ibrahim.


Clinical Oral Implants Research | 2015

Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT

Azin Parsa; Norliza Ibrahim; Bassam Hassan; Paul F. van der Stelt; Daniel Wismeijer

OBJECTIVES The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. MATERIAL AND METHODS Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. RESULTS Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P < 0.001) except for mean measurement between CBCT BV/TV and micro-CT BV/TV (P = 0.147). CONCLUSIONS An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site.


Dentomaxillofacial Radiology | 2013

Influence of cone beam CT scanning parameters on grey value measurements at an implant site

Azin Parsa; Norliza Ibrahim; Bassam Hassan; A. Motroni; P.F. van der Stelt; Daniel Wismeijer

OBJECTIVES The aim of this study was to determine the grey value variation at the implant site with different scan settings, including field of view (FOV), spatial resolution, number of projections, exposure time and dose selections in two cone beam CT (CBCT) systems and to compare the results with those obtained from a multislice CT system. METHODS A partially edentulous human mandibular cadaver was scanned by three CT modalities: multislice CT (MSCT) (Philips, Best, the Netherlands), and two CBCT systems: (Accuitomo 170(®), Morita, Japan) and (NewTom 5G(®), QR, Verona, Italy). Using different scan settings 36 and 24 scans were obtained from the Accuitomo and the NewTom, respectively. The scans were converted to digital imaging and communications in medicine 3 format. The analysis of the data was performed using 3Diagnosys(®) software (v. 3.1, 3diemme, Cantù, Italy) and Geomagic studio(®) 2012 (Morrisville, NC). On the MSCT scan, one probe designating the site for pre-operative implant placement was inserted. The inserted probe on MSCT was transformed to the same region on each CBCT scan using a volume-based three-dimensional registration algorithm. The mean voxel grey value of the region around the probe was derived separately for each CBCT. The influence of scanning parameters on the measured mean voxel grey values was assessed. RESULTS Grey values in both CBCT systems significantly deviated from Hounsfield unit values measured with MSCT (p = 0.0001). In both CBCT systems, scan FOV and spatial resolution selections had a statistically significant influence on grey value measurements (p = 0.0001). The number of projections selection had a statistically significant influence in the Accuitomo system (p = 0.0001) while exposure time and dose selections had no statistically significant influence on grey value measurements in the NewTom (p = 0.43 and p = 0.37, respectively). CONCLUSIONS Grey-level values from CBCT images are influenced by device and scanning settings.


Dentomaxillofacial Radiology | 2013

Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review

Norliza Ibrahim; Azin Parsa; Bassam Hassan; P.F. van der Stelt; Daniel Wismeijer

Several dental implant studies have reported that radiographic evaluation of bone quality can aid in reducing implant failure. Bone quality is assessed in terms of its quantity, density, trabecular characteristics and cells. Current imaging modalities vary widely in their efficiency in assessing trabecular structures, especially in a clinical setting. Most are very costly, require an extensive scanning procedure coupled with a high radiation dose and are only partially suitable for patient use. This review examines the current literature regarding diagnostic imaging assessment of trabecular microstructure prior to oral implant placement and suggests cone beam CT as a method of choice for evaluating trabecular bone microstructure.


Clinical Oral Implants Research | 2014

Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone-beam CT datasets

Norliza Ibrahim; Azin Parsa; Bassam Hassan; Paul F. van der Stelt; Irene H. A. Aartman; Daniel Wismeijer

OBJECTIVE Cone-beam CT (CBCT) images are infrequently utilized for trabecular bone microstructural measurement due to the systems limited resolution. The aim of this study was to determine the accuracy of CBCT for measuring trabecular bone microstructure in comparison with micro CT (μCT). MATERIALS AND METHODS Twenty-four human mandibular cadavers were scanned using a CBCT system (80 μm) and a μCT system (35 μm). Three bone microstructural parameters trabecular number (Tb.N), thickness (Tb.Th) and separation (Tb.Sp) were assessed using CTAn imaging software. RESULTS Intraclass correlation coefficients (ICC) showed a high intra-observer reliability (≥ 0.996) in all parameters for both systems. The Pearson correlation coefficients between the measurements of the two systems were for Tb.Th 0.82, for Tb.Sp 0.94 and for Tb.N 0.85 (all Ps<0.001). The Bland and Altman plots showed strongest agreement in Tb.N (-0.37 μm) followed by Tb.Th (1.6 μm) and Tb.Sp (8.8 μm). CONCLUSIONS Cone-beam CT datasets can be used to evaluate trabecular bone microstructure at dental implant sites. The accuracy for measuring Tb.N was the best followed by Tb.Th and Tb.Sp.


Dentomaxillofacial Radiology | 2014

Assessment of metal artefact reduction around dental titanium implants in cone beam CT

Azin Parsa; Norliza Ibrahim; Bassam Hassan; K. Syriopoulos; P.F. van der Stelt

OBJECTIVES The aim of this study was to investigate if the metal artefact reduction (MAR) tool used in the software of the ORTHOPANTOMOGRAPH(®) OP300 (Instrumentarium Dental, Tuusula, Finland) can improve the gray value levels in post-operative implant scans. METHODS 20 potential implant sites were selected from 5 edentulous human dry mandibles. Each mandible was scanned by a CBCT scanner, and images were produced under three different conditions: implant sites drilled but no implants inserted, implants inserted without application of MAR and implants inserted with application of MAR. Using Geomagic(®) Studio 2012 (Geomagic, Morrisville, NC) and 3Diagnosys(®) v. 5.3.1 (3Diemme(®) SRL, Cantù, Italy) software, three scans of each mandible were superimposed. The mean gray value of identical regions of bone around the implants was derived for each condition. The differences between gray value measurements at implant sites derived from different conditions were assessed. RESULTS A significant difference was found between mean gray values from the scans with no implants inserted and with implants inserted (with and without MAR) (p = 0.012). No significant difference was revealed for gray values measured from scans with and without MAR (p = 0.975). CONCLUSIONS The MAR tool in the software of the ORTHOPANTOMOGRAPH OP300 CBCT scanner does not significantly correct the voxel gray values affected by the metal artefact in the vicinity of an implant in human dry mandibles.


Dentomaxillofacial Radiology | 2014

Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study

Norliza Ibrahim; Azin Parsa; Bassam Hassan; P.F. van der Stelt; Irene H. A. Aartman; Phrabhakaran Nambiar

The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre, left, right, anterior and posterior) using five different FOVs of two CBCT systems (NewTom™ 5G; QR Verona, Verona, Italy and Accuitomo 170; Morita, Kyoto, Japan). Image analysis software (CTAn software v. 1.1; SkyScan, Kontich, Belgium) was used to assess the trabecular bone microstructural parameters (thickness, Tb.Th; spacing, Tb.Sp; number, Tb.N; bone volume density, BV/TV). All measurements were taken twice by one trained observer. Tb.Th, Tb.Sp and Tb.N varied significantly across different FOVs in the NewTom 5G (p < 0.001) and the Accuitomo 170 (p < 0.001). For location, a significant difference was observed only when measuring BV/TV (p = 0.03) using the NewTom 5G. The trabecular bone microstructural measurements obtained from CBCT systems are influenced by the size of FOVs. Not all trabecular bone parameters measured using different CBCT systems are affected when varying the object location within the FOVs.


Oral Radiology | 2008

Susuks (charm needles) in the craniofacial region

Phrabhakaran Nambiar; Norliza Ibrahim; Yeti Rosalina Muslim Tandjung; P Shanmuhasuntharam

ObjectivesWe conducted a study to determine the numbers of susuks (charm needles) and their distribution in the craniofacial region of susuk wearers, and the sex, racial affiliation, and age of the wearers. In addition, we sought to determine whether the presence of susuks posed any potential hazard to patients undergoing magnetic resonance imaging (MRI).MethodsWe studied various radiographs of 33 susuk wearers (age range, 33–69 years) and investigated the most common sites of insertion in the craniofacial region. A susuk was also suspended inside a 1.5-T MRI machine to determined whether it was attracted by the machine’s magnet.ResultsThe largest number of susuks that we observed in the craniofacial region was 39 pins, and susuks were particularly numerous in Malay Muslim women. Other sites with susuks were the maxillofacial region (except the temporomandibular region) and the forehead. The susuks showed no ferromagnetic characteristics.ConclusionsAs susuks are made from gold, they are generally biocompatible with human tissue and do not cause problems to their wearers. Gold and the other minor metal constituents found in susuks have no ferromagnetic characteristics and therefore pose no hazard to patients undergoing MRI.


BMC Public Health | 2014

The health-related quality of life among pre-diabetics and its association with body mass index and physical activity in a semi-urban community in Malaysia--a cross sectional study.

Norliza Ibrahim; Foong Ming Moy; Intan Attikah Nur Awalludin; Zainudin Mohd Ali; Ikram Shah Bin Ismail

BackgroundPeople with pre-diabetes are at high risk of developing type 2 diabetes and cardiovascular diseases. Measurements of health-related quality of life (HRQOL) among pre-diabetics enable the health care providers to understand their overall health status and planning of interventions to prevent type 2 diabetes. Therefore we aimed to determine the HRQOL and physical activity level; and its association with Body Mass Index (BMI) among pre-diabetics.MethodsThis was a cross sectional study carried out in two primary care clinics in a semi-urban locality of Ampangan, Negeri Sembilan, Malaysia. Data was collected through self-administered questionnaires assessing the demographic characteristics, medical history, lifestyle and physical activity. The Short Form 36-items health survey was used to measure HRQOL among the pre-diabetics. Data entry and analysis were performed using the SPSS version 19.ResultsA total of 268 eligible pre-diabetics participated in this study. The prevalence of normal weight, overweight and obesity were 7.1%, 21.6% and 71.3% respectively. Their mean (SD) age was 52.5 (8.3) years and 64.2% were females. Among the obese pre-diabetics, 42.2% had both IFG and IGT, 47.0% had isolated IFG and 10.8% had isolated IGT, 36.2% had combination of hypertension, dyslipidemia and musculoskeletal diseases. More than 53.4% of the obese pre-diabetics had family history of diabetes, 15.7% were smokers and 60.8% were physically inactive with mean PA of < 600 MET-minutes/week. After adjusted for co-variants, Physical Component Summary (PCS) was significantly associated with BMI categories [F (2,262) = 11.73, p < 0.001] where pre-diabetics with normal weight and overweight had significantly higher PCS than those obese; normal vs obese [Mdiff = 9.84, p = 0.006, 95% CIdiff = 2.28, 17.40] and between overweight vs obese [Mdiff = 8.14, p < 0.001, 95% CIdiff = 3.46, 12.80].ConclusionPre-diabetics who were of normal weight reported higher HRQOL compared to those overweight and obese. These results suggest a potentially greater risk of poor HRQOL among pre-diabetics who were overweight and obese especially with regard to the physical health component. Promoting recommended amount of physical activity and weight control are particularly important interventions for pre-diabetics at the primary care level.


PLOS ONE | 2016

Effects of a Community-Based Healthy Lifestyle Intervention Program (Co-HELP) among Adults with Prediabetes in a Developing Country: A Quasi-Experimental Study.

Norliza Ibrahim; Foong Ming Moy; Intan Attikah Nur Awalludin; Zainudin Mohd Ali; Ikram Shah Bin Ismail

Background The prevalence of type 2 diabetes among Malaysian adults has increased by more than two folds over the past two decades. Strategies to collaborate with the existing community partners may become a promising channel for wide-scale dissemination of diabetes prevention in the country. The objectives of this study were to determine the effects of community-based lifestyle interventions delivered to adults with prediabetes and their health-related quality of life as compared to the usual care group. Methods This was a quasi-experimental study conducted in two sub-urban communities in Seremban, Malaysia. A total of 268 participants with prediabetes aged between 18 to 65 years old were assigned to either the community-based lifestyle intervention (Co-HELP) (n = 122) or the usual care (n = 146) groups. The Co-HELP program was delivered in partnership with the existing community volunteers to incorporate diet, physical activity, and behaviour modification strategies. Participants in the Co-HELP group received twelve group-based sessions and two individual counselling to reinforce behavioural change. Participants in the usual care group received standard health education from primary health providers in the clinic setting. Primary outcomes were fasting blood glucose, 2-hour plasma glucose, and HbA1C. Secondary outcomes included weight, BMI, waist circumference, total cholesterol, triglyceride, LDL cholesterol, HDL cholesterol, systolic and diastolic blood pressure, physical activity, diet, and health-related quality of life (HRQOL). Results An intention-to-treat analysis of between-groups at 12-month (mean difference, 95% CI) revealed that the Co-HELP participants’ mean fasting plasma glucose reduced by -0.40 mmol/l (-0.51 to -0.28, p<0.001), 2-hour post glucose by -0.58 mmol/l (-0.91 to -0.24, p<0.001), HbA1C by -0.24% (-0.34 to -0.15, p<0.001), diastolic blood pressure by -2.63 mmHg (-3.79 to -1.48, p<0.01), and waist circumference by -2.44 cm (-4.75 to -0.12, p<0.05) whereas HDL cholesterol increased by 0.12 mmol/l (0.05 to 0.13, p<0.01), compared to the usual care group. Significant improvements were also found in HRQOL for both physical component (PCS) by 6.51 points (5.21 to 7.80, p<0.001) and mental component (MCS) by 7.79 points (6.44 to 9.14, p<0.001). Greater proportion of participants from the Co-HELP group met the clinical recommended target of 5% or more weight loss from the initial weight (24.6% vs 3.4%, p<0.001) and physical activity of >600 METS/min/wk (60.7% vs 32.2%, p<0.001) compared to the usual care group. Conclusions This study provides evidence that a culturally adapted diabetes prevention program can be implemented in the community setting, with reduction of several diabetes risk factors and improvement of HRQOL. Collaboration with existing community partners demonstrated a promising channel for the wide-scale dissemination of diabetes prevention at the community level. Further studies are required to determine whether similar outcomes could be achieved in communities with different socioeconomic backgrounds and geographical areas. Trial Registration IRCT201104106163N1


Legal Medicine | 2019

Dental age estimation in Malaysian adults based on volumetric analysis of pulp/tooth ratio using CBCT data

Muhammad Khan Asif; Phrabhakaran Nambiar; Shani Ann Mani; Norliza Ibrahim; Iqra Muhammad Khan; Najihah Binti Lokman

Forensic odontology plays an important role in human identification and dental age estimation is an integral part of this process. The aim of the study was to investigate the association between chronological age and pulp/tooth volume ratio in a Malaysian population (Malays and Chinese) from cone-beam computed tomography (CBCT) scans, enhanced with Mimics software. Three hundred CBCT scans of 153 males and 147 females, aged between 16 and 65 years were divided into 5 age groups. Volumetric analysis of the pulp/tooth ratio was performed in maxillary left canines, maxillary right canines and maxillary right central incisors. Simple linear regression and Pearson correlation analysis indicated the strongest coefficient of correlation (R) values for maxillary right central incisors (0.83) followed by maxillary right canines (0.74) and maxillary left canines (0.73). Fishers Z test indicated that dental age estimation is gender independent. The derived regression equations were further validated on an independent group of 126 teeth. The results indicated mean absolute error (MAE) values of 6.48 and 8.58 years for maxillary right central incisors and maxillary canines respectively. It was also noticed that MAE values were higher among the age groups ranging from 46 to 65 years. This study showed that a volumetric change in the pulp cavity with age is a valuable assessment method for dental age estimation among Malaysian population.

Collaboration


Dive into the Norliza Ibrahim's collaboration.

Top Co-Authors

Avatar

Azin Parsa

Academic Center for Dentistry Amsterdam

View shared research outputs
Top Co-Authors

Avatar

Bassam Hassan

Academic Center for Dentistry Amsterdam

View shared research outputs
Top Co-Authors

Avatar

Daniel Wismeijer

Academic Center for Dentistry Amsterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

P.F. van der Stelt

Academic Center for Dentistry Amsterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Irene H. A. Aartman

Academic Center for Dentistry Amsterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge