Olavi Vaittinen
University of Helsinki
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Olavi Vaittinen.
Biomarkers | 2009
Kristin Stamyr; Olavi Vaittinen; Janne Jaakola; Joseph Guss; Markus Metsälä; Gunnar Johanson; Lauri Halonen
Hydrogen cyanide (HCN) in breath has been suggested as a diagnostic tool for cyanide poisoning and for cyanide-producing bacterial infections. To distinguish elevated levels of breath HCN, baseline data are needed. Background levels of HCN were measured in mixed exhaled air from 40 healthy subjects (26 men, 14 women, age 21–61 years; detection limit: 1.5 ppb; median: 4.4 ppb; range <1.5–14 ppb) by near-infrared cavity ring down spectroscopy (CRDS). No correlation was observed with smoking habits, recent meals or age. However, female subjects had slightly higher breath levels of HCN than male subjects. CRDS has not previously been used for this purpose.
Journal of The Optical Society of America B-optical Physics | 2006
Raúl Z. Martinez; Markus Metsälä; Olavi Vaittinen; Tommi Lantta; Lauri Halonen
We describe the design, construction, and initial performance evaluation of a high-repetition-rate cavity ringdown spectrometer. The spectrometer is based on the use of the Pound-Drever-Hall technique to lock the laser frequency to the maximum of a transmission fringe of the interferometer used as a sample cell. This results in continuous injection of light into the interferometer. The injection is repetitively interrupted with an acousto-optical modulator to generate ringdowns (exponential decays) at a typical rate of 10 kHz. Averaging of these large numbers of fitted ringdown times allows us to attain a minimum detectable absorption of 1.43×10−11 cm−1 Hz−1/2 short term and 9.0×10−11 cm−1 Hz−1/2 long term. In addition, the spectrometer has a continuous tuning capability of ∼1 cm−1, which allows the use of standard linearization and frequency calibration techniques for the spectrum. To illustrate the operation and sensitivity of the spectrometer, part of the Q-branch of a weak acetylene overtone has been recorded.
Journal of Breath Research | 2011
Florian M. Schmidt; Markus Metsälä; Olavi Vaittinen; Lauri Halonen
The hydrogen cyanide (HCN) concentration in exhaled human breath and skin gas samples collected with different sampling techniques was measured using near-infrared cavity ring-down spectroscopy. The median baseline HCN concentrations in samples provided by 19 healthy volunteers 2-4 h after the last meal depended on the employed sampling technique: 6.5 parts per billion by volume (ppbv) in mixed (dead space and end-tidal) mouth-exhaled breath collected to a gas sampling bag, 3.9 ppbv in end-tidal mouth-exhaled breath, 1.3 ppbv in end-tidal nose-exhaled breath, 1.0 ppbv in unwashed skin and 0.6 ppbv in washed skin samples. Diurnal measurements showed that elevated HCN levels are to be expected in mouth-exhaled breath samples after food and drink intake, which suggests HCN generation in the oral cavity. The HCN concentrations in end-tidal nose-exhaled breath and skin gas samples were correlated, and it is concluded that these concentrations best reflect systemic HCN levels.
Chemical Physics Letters | 1991
Xiaowei Zhan; Olavi Vaittinen; Esa Kauppi; Lauri Halonen
Abstract A high-resolution vibration—rotation spectrum of acetylene has been obtained in the wavenumber region 17360–17560 cm −1 with a new ring-dye-laser spectrometer where an intracavity photoacoustic detection method has been used. The spectra obtained show large signal-to-noise ratios. Five new very weak bands have been observed and successfully analyzed to provide a set of vibrational term values and rotational constants.
Journal of Chemical Physics | 1993
Olavi Vaittinen; Maria Saarinen; Lauri Halonen; Ian Mills
Intracavity photoacoustic overtone spectrum of monofluoroacetylene, HCCF, has been recorded in the wave number region 10 750–14 500 cm−1 with a titanium:sapphire ring laser. The spectrum contains many dense vibration–rotation band systems which can be resolved with Doppler limited resolution. Altogether 58 individual overtone bands have been analyzed rotationally. Many of the observed bands show perturbations of which some have been attributed to anharmonic resonance interactions. A Fermi resonance model based on conventional rectilinear normal coordinate theory has been used to assign vibrationally bands from this work and from earlier studies. Many of the observed vibrational term values and rotational constants can be reproduced well with this model. The results show the importance of the Fermi resonance interactions at the high overtone excitations.
Journal of Breath Research | 2010
Markus Metsälä; Florian M. Schmidt; Mirva Skytta; Olavi Vaittinen; Lauri Halonen
We have measured the acetylene concentration in the exhaled breath of 40 volunteers (31 non-smokers, nine smokers) using near-infrared cavity ring-down spectroscopy. The acetylene levels were found to be the same as in ambient air for non-smokers, whereas elevated levels were observed for smokers. Real-time measurements with sub-second time resolution have been applied to measure the elimination kinetics of acetylene in breath after exposure to tobacco smoke. Three exponential time constants can be distinguished from the data and these can be used to define the residence times for different compartments, according to the multi-compartment model of the human body.
Journal of Chemical Physics | 2002
Markus Metsälä; Shengfu Yang; Olavi Vaittinen; Lauri Halonen
The laser-induced dispersed vibration–rotation fluorescence method has been developed further when compared with a previous publication [Saarinen et al., J. Chem. Phys. 110, 1424 (1999)]. More than one order of magnitude better signal-to-noise ratio has been achieved in the wave-number region 2900–3500 cm−1 by taking advantage of directionality of the fluorescence signal. The improvement has been applied to overtone spectroscopy of normal acetylene where for high CH stretching excitations separate spectra of ortho and para forms are obtained containing basically just single CH stretching vibrational quantum transitions from the pumped antisymmetric vibrational (ν1+3ν3(Σu+) and ν2+3ν3(Σu+)) and close-lying symmetric vibrational local mode (4ν3(Σg+) and ν1+ν2+2ν3(Σg+)) states. No nuclear spin conversion is observed in these spectra. Two new symmetric vibrational states (ν1+2ν2+4ν40(Σg+)(29%) and (50%)) have been observed and the precision of the spectroscopic parameters of previously published symmetric sta...
Chemical Physics Letters | 2001
Markus Metsälä; Shengfu Yang; Olavi Vaittinen; Dmitri Permogorov; Lauri Halonen
Abstract The cavity ring-down laser method using a continuously tunable titanium:sapphire ring laser with an external high-finesse cavity has been used to record a high-resolution overtone spectrum of a gaseous 12 C 2 H 2 sample in the wavenumber region 12 260–12 380 cm −1 . A direct non-linear least-squares fitting of the ring-down signal is found to lead to increased sensitivity when compared with the linear-least squares methods. Two new bands have been observed and rotationally analysed. A comparison of the new results with previous theoretical work shows a good agreement.
Chemical Physics Letters | 1992
David Newnham; Xiaowei Zhan; Olavi Vaittinen; Esa Kauppi; Lauri Halonen
Abstract A titanium : sapphire ring laser has been used in intracavity experiments to obtain high-resolution photoacoustic overtone spectra of monofluoroacetylene in the wavenumber region 12200–13800 cm −1 . The spectra obtained show very large signal-to-noise ratios (> 1000) for strong absorption peaks. Two band systems, 4ν 1 and 4ν 1 + ν 5 , have been observed. Both of these contain several individual bands which often seem to be severely perturbed. Altogether seven bands in the 4ν 1 band system have been assigned rotationally.
Current Analytical Chemistry | 2013
Olavi Vaittinen; Florian M. Schmidt; Markus Metsälä; Lauri Halonen
Biological monitoring usually relies on the collection of blood and urine samples. Although being non-invasive and providing an inextinguishable sampling pool, the analysis of exhaled breath is not ...