Olga Boric-Lubecke
University of Hawaii at Manoa
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Olga Boric-Lubecke.
IEEE Transactions on Microwave Theory and Techniques | 2004
Amy Droitcour; Olga Boric-Lubecke; Victor Lubecke; Jenshan Lin; Gregory T. A. Kovacs
Direct-conversion microwave Doppler-radar transceivers have been fully integrated in 0.25-/spl mu/m silicon CMOS and BiCMOS technologies. These chips, operating at 1.6 and 2.4 GHz, have detected movement due to heartbeat and respiration 50 cm from the subject, which may be useful in infant and adult apnea monitoring. The range-correlation effect on residual phase noise is a critical factor when detecting small phase fluctuations with a high-phase-noise on-chip oscillator. Phase-noise reduction due to range correlation was experimentally evaluated, and the measured residual phase noise was within 5 dB of predicted values on average. In a direct-conversion receiver, the phase relationship between the received signal and the local oscillator has a significant effect on the demodulation sensitivity, and the null points can be avoided with a quadrature (I/Q) receiver. In this paper, measurements that highlight the performance benefits of an I/Q receiver are presented. While the accuracy of the heart rate measured with the single-channel chip ranges from 40% to 100%, depending on positioning, the quadrature chip accuracy is always better than 80%.
IEEE Transactions on Microwave Theory and Techniques | 2007
Byung-Kwon Park; Olga Boric-Lubecke; Victor Lubecke
Direct-conversion microwave Doppler radar can be used to detect cardiopulmonary activity at a distance. One challenge for such detection in single channel receivers is demodulation sensitivity to target position, which can be overcome by using a quadrature receiver. This paper presents a mathematical analysis and experimental results demonstrating the effectiveness of arctangent demodulation in quadrature receivers. A particular challenge in this technique is the presence of dc offset resulting from receiver imperfections and clutter reflections, in addition to dc information related to target position and associated phase. These dc components can be large compared to the ac motion-related signal, and thus, cannot simply be included in digitization without adversely affecting resolution. Presented here is a method for calibrating the dc offset while preserving the dc information and capturing the motion-related signal with maximum resolution. Experimental results demonstrate that arctangent demodulation with dc offset compensation results in a significant improvement in heart rate measurement accuracy over quadrature channel selection, with a standard deviation of less than 1 beat/min
IEEE Transactions on Microwave Theory and Techniques | 2013
Changzhi Li; Victor Lubecke; Olga Boric-Lubecke; Jenshan Lin
This paper reviews recent advances in biomedical and healthcare applications of Doppler radar that remotely detects heartbeat and respiration of a human subject. In the last decade, new front-end architectures, baseband signal processing methods, and system-level integrations have been proposed by many researchers in this field to improve the detection accuracy and robustness. The advantages of noncontact detection have drawn interests in various applications, such as energy smart home, baby monitor, cardiopulmonary activity assessment, and tumor tracking. While many of the reported systems were bench-top prototypes for concept verification, several portable systems and integrated radar chips have been demonstrated. This paper reviews different architectures, baseband signal processing, and system implementations. Validations of this technology in a clinical environment will also be discussed.
international microwave symposium | 2001
Amy Droitcour; Victor Lubecke; Jenshan Lin; Olga Boric-Lubecke
A microwave radio for Doppler radar sensing of vital signs is described. This radio was developed using custom DCS1800/PCS1900 base station RFICs. It transmits a single tone signal, demodulates the reflected signal, and outputs a baseband signal. If the object that reflects the signal has periodic motion, the magnitude of the baseband output signal is directly proportional to the periodic displacement of the object. When the signal is reflected off a persons chest, this radio with appropriate baseband filters can detect heart and respiration rates from a distance as large as one meter from the target.
IEEE Transactions on Microwave Theory and Techniques | 2009
Wansuree Massagram; Victor Lubecke; Anders Høst-Madsen; Olga Boric-Lubecke
An investigation of heart rate variability (HRV) and respiratory sinus arrhythmia (RSA) indices using data obtained from Doppler radar cardiopulmonary remote sensing is presented in this paper. High accuracy in extracting the HRV and RSA indices was achieved using a direct-conversion quadrature radar system with linear demodulation method. This method was validated using data obtained from 12 human subjects in seated and supine positions. For supine position measurements, all standard deviation of normal beat-to-beat interval indices from Doppler radar and electrocardiogram reference differed less than plusmn9 ms of each other, while all the root mean square of differences of successive normal beat-to-beat interval indices differed less than plusmn76 ms. The measurements from subjects in seated and supine positions with normal RSA demonstrated that the results from radar correlated well with both respiratory piezoresistor chest belts. Higher level of HRV and RSA was detected in seated position, as expected.
international microwave symposium | 2007
Victor Lubecke; Olga Boric-Lubecke; Anders Høst-Madsen; Aly E. Fathy
Technology that can be used to unobtrusively detect and monitor the presence of human subjects from a distance and through barriers can be a powerful tool for law enforcement, military, and health monitoring applications. To this end, ultra-wide band radar has shown promise for real-time subject imaging, and compact Doppler radar solutions have demonstrated potential for providing non-invasive detection and monitoring of cardiopulmonary activity for multiple subjects. These technologies work through walls and other obstructions, and can even leverage the presence of ambient radio signals to provide a covert means to detect, isolate, and physiologically monitor multiple human subjects from a remote position. Practical applications ranging from counter-terrorism to health monitoring require systems that are accurate, affordable, and easy to use. Current research efforts addressing these challenges through radio, signal processing, and sensor networking will be presented.
IEEE Transactions on Microwave Theory and Techniques | 2009
Amy Droitcour; Olga Boric-Lubecke; Gregory T. A. Kovacs
A CMOS Doppler radar sensor has been developed and used to measure motion due to heart and respiration. The quadrature direct-conversion radar transceiver has been fully integrated in 0.25-mum CMOS, the baseband analog signal conditioning has been developed on a printed circuit board, and digital signal processing has been performed in Matlab. The theoretical signal-to-noise ratio (SNR) is derived based on the radar equation, the direct-conversion receivers properties, oscillator phase noise, range correlation, and receiver noise. Heart and respiration signatures and rates have been measured at ranges from 0.5 to 2.0 m on 22 human subjects wearing normal T-shirts. The theoretical SNR expression was validated with this study. The heart rates found with the radar sensor were compared with a three-lead electrocardiogram, and they were within 5 beats/min with 95% confidence for 16 of 22 subjects at a 0.5-m range and 11 of 22 subjects at a 1.0-m range. The respiration rates found with the radar sensor were compared with those found using a piezoelectric respiratory effort belt, and the respiration rates were within five respirations per minute for 18 of 22 subjects at a 0.5-m range, 17 of 22 subjects at a 1.0-m range, and 19 of 22 subjects at a 1.5-m range.
international conference on acoustics, speech, and signal processing | 2006
Qin Zhou; Jianhan Liu; Anders Høst-Madsen; Olga Boric-Lubecke; Victor Lubecke
Doppler radar life sensing has shown promise in medical and security applications. The current paper considers the problem of determining the number of persons in a given area (e.g., a room) using the Doppler shift due to heartbeat. The signal is weak and time-varying, and therefore poses a complicated signal processing problem. We develop a generalized likelihood ratio test (GLRT) based on a model of the heartbeat, and show that this can be used to distinguish between the presence of 2, 1, or 0 subjects, even with a single antenna. We further extend this to N antennas. The results show that one can expect to detect up to 2N-1 subjects using this technique
international conference of the ieee engineering in medicine and biology society | 2005
Yanming Xiao; Jenshan Lin; Olga Boric-Lubecke; Victor Lubecke
A low power Ka-band Doppler radar that can detect human heartbeat and respiration signals is demonstrated. This radar system achieves better than 80% detection accuracy at the distance of 2-m with 16-muW transmitted power. Indirect-conversion receiver architecture is chosen to reduce the DC offset and 1/f noise that can degrade signal-to-noise ratio and detection accuracy. In addition, the radar has also demonstrated the capability of detecting acoustic signals
radio and wireless symposium | 2006
Byung-Kwon Park; Shuhei Yamada; Olga Boric-Lubecke; Victor Lubecke
Periodic motion, such as that resulting from cardiopulmonary activity can be measured by direct-conversion microwave Doppler radar. In a direct-conversion receiver, motion is measured as phase modulation, and the baseline phase relationship between the received signal and local oscillator signal for a given position has a significant effect on the demodulation sensitivity, resulting in optimum and null case extreme target positions. Presented here is a mathematical analysis of this target-position sensitivity verified with measurements using a custom compact Doppler radar transceiver with separate quadrature outputs. The results indicate that increased error in respiration and heart rate measurements can be expected for null case positions due to significant changes in mathematical conditions as well as reduced sensitivity, and that these limitations can be accommodated using two receiver channels in quadrature.