Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Otto-Christian Dr. Geyer is active.

Publication


Featured researches published by Otto-Christian Dr. Geyer.


Klinische Monatsblatter Fur Augenheilkunde | 2002

Kunststoffe am Auge - Kunststoffe im Auge. Humanoptische Werkstoffe

Otto-Christian Dr. Geyer; Peter Dr. Schwabe; Frank Wingler

Background: Materials of identical or similiar chemical classes are used for contact optics as well as for implantable intraocular devices. All of them derive from the chemistry of industrial product developments. Patients and methods: Materials used in and on the eye should behave indifferent. They should not provoke any reaction in the eye and not themselves be alterated by the biological surroundings. For materials used in the eye an especially high purity of the polymers utilized as well as a long term light stability is to be demanded. Optical properties like transparency have to be stable over extended time periods under normal light influence. The long time stability of UV-absorbing additives in the materials used has to be verified. Results: All materials used for lOLs - with the exception of the homopolymer of methylmethacrylate - consit of polymer mixtures forming socalled interpenetrating networks which appear as an uniform material. For the manufacturing of intraocular lense materials standardized or unanimous producer prescriptions are not existing. Based on the different polymer formulations different aging and fatigue peoperties are the outcome. In addition only inadequate knowledge about the long term light stability of the incorporated UV blockers is submitted. Conclusions: Polymeric materials used for lOLs should be subjected in addition to the test methods listed in EN-ISO 11979/5 to chemical, polymeranalytic and mechanical substance examinations. As a standard in such examinations a polymethylmethacrylate, free of methylacrylate is proposed. Examinations of each lot should be compulsory. Identification of all ingredients of the intraocular materials should be prescribed and labeled in line with the revelations of common medical drugs prescriptions. The relevations commit the medical doctor to inform his patient about possible side effects of the intraocular implants.


Archive | 1987

Optical contact objects

Frank Wingler; Otto-Christian Dr. Geyer


Archive | 1987

Hydrophilic copolymers, the use thereof as biomedical materials and contact-optical articles produced therefrom

Otto-Christian Dr. Geyer; Frank Wingler


Archive | 1984

Use of polymer alloys based on cellulose esters in contact ophthalmics, and contact lenses produced from the polymer alloys

Frank Wingler; Helmut Dr. Waniczek; Otto-Christian Dr. Geyer


Archive | 1989

Optically clear silicone compositions

Peter Dr. Schwabe; Reiner Voigt; Ottfried Schlak; Otto-Christian Dr. Geyer


Archive | 1980

Contact lenses of methyl methacrylate copolymers

Frank Wingler; Bernd Dr. Leusner; Peter Dr. Schwabe; Otto-Christian Dr. Geyer


Archive | 1988

Manufacturing process of half-finished contact lenses

Otto-Christian Dr. Geyer; Frank Wingler


Archive | 1984

Process for manufacturing optical contact elements

Peter Dr. Schwabe; Frank Wingler; Otto-Christian Dr. Geyer


Archive | 1980

Contact lenses made from methyl methacrylate copolymers

Frank Wingler; Bernd Dr. Leusner; Peter Dr. Schwabe; Otto-Christian Dr. Geyer


Archive | 1987

Composition for contact lenses

Frank Wingler; Otto-Christian Dr. Geyer

Researchain Logo
Decentralizing Knowledge