P. Ciliberti
University of Trieste
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by P. Ciliberti.
Journal of Instrumentation | 2010
M. Alexeev; M. Alfonsi; R. Birsa; F. Bradamante; A. Bressan; M. Chiosso; P. Ciliberti; G. Croci; M.L. Colantoni; S. Dalla Torre; O. Denisov; S. Duarte Pinto; V. Duic; A. Ferrero; M. Finger; H. Fischer; G. Giacomini; M. Giorgi; B. Gobbo; R. Hagemann; F.H. Heinsius; F. Herrmann; V. Jahodova; K. Königsmann; D. Kramer; L. Lauser; S. Levorato; A. Maggiora; A. Martin; G. Menon
The development of a large size gaseous detector of single photons, able to stably operate at high gain and high rate, and to provide good time resolution and insensitivity to magnetic field would be beneficial to future Cherenkov Imaging Counters. The detector could be based on the use of a multilayer architecture of THGEM electron multipliers coupled to a solid state CsI photocathode. A systematic study of the response of THGEM-based counters versus the geometrical parameters has been performed and the main results will be presented. Small photon detector prototypes have been built and preliminary data obtained detecting single photoelectrons are presented as well. The key aspect of photoelectron extraction from the photocathode is illustrated presenting both simulation and dedicated measurement results.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2003
E. Albrecht; Günter Baum; R. Birsa; M. Bosteels; F. Bradamante; A. Braem; A. Bressan; A. Cicuttin; P. Ciliberti; A. Colavita; S. Costa; M.L. Crespo; P. Cristaudo; S. Dalla Torre; V. Diaz; P. Fauland; M. Finger; F. Fratnik; M. Giorgi; B. Gobbo; A. Grasso; R. Ijaduola; V. Kalinnikov; M. Lamanna; M Laub; A. Martin; G. Menon; P. Pagano; D. Panzieri; D. Piedigrossi
RICH-1, one of the key detectors of the COMPASS experiment at CERN SPS, is described. Photon detectors are MWPCs equipped with CsI photo-cathodes.
Journal of Instrumentation | 2012
M. Alexeev; F. Barbosa; R. Birsa; F. Bradamante; A. Bressan; M. Chiosso; P. Ciliberti; S. Dalla Torre; O. Denisov; V. Duic; M. Finger; H. Fischer; M. Giorgi; B. Gobbo; M. Gregori; F. Herrmann; K. Konigsmann; D. Kramer; S. Levorato; A. Maggiora; A. Martin; G. Menon; A. Mutter; F. Nerling; K. Novakova; J. Novy; D. Panzieri; J. Polak; E. Rocco; C. Santos
The photon detectors based on MPGD (MicroPattern Gaseous Detector) represent the new generation of gaseous photon detectors. We report about an R&D programme dedicated to study both the principles and the engineering aspects of photon detectors based on Thick GEMs (THGEM) electron multipliers coupled to a CsI photoconverting coating. The goal is the development of a gaseous detector of single UV photons, able to stably operate at high gain and high rate, to provide good time resolution and insensitive to magnetic field to be used in the Cherenkov imaging counter RICH-1 of the COMPASS experiment at CERN SPS.
Journal of Instrumentation | 2013
M.G. Alexeev; R. Birsa; F. Bradamante; A. Bressan; M. Chiosso; P. Ciliberti; S. Dalla Torre; S. Dasgupta; O. Denisov; V. Duic; M. Finger; H. Fischer; M. Giorgi; B. Gobbo; M. Gregori; F. Herrmann; K. Konigsmann; S. Levorato; Qian Liu; A. Maggiora; A. Martin; G. Menon; F. Nerling; K. Novakova; J. Novy; D. Panzieri; F. Pereira; C. A. Santos; G. Sbrizzai; P. Schiavon
Photon detectors based on micropattern gas detectors represent a new generation of gaseous photon detectors. In the context of a project to upgrade the gas photon detectors of COMPASS RICH-1, we are performing an R&D programme aimed both to establish the principles and to develop the engineering aspects of photon detectors based on multi-layer arrangements of thick GEMs electron multipliers coupled to a CsI photoconverter. In this context, a reduced rate of the backflow of the positive ions generated in the multiplication process is required to overcome the critical issues related to the bombardment of the CsI photoconverter by ions. Our studies devoted to develop detector architectures able to provide reduced ion backflow rates are reported.
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE | 2009
M. Alexeev; R. Birsa; F. Bradamante; A. Bressan; M. Chiosso; P. Ciliberti; G. Croci; M.L. Colantoni; S. Dalla Torre; S. Duarte Pinto; O. Denisov; V. Diaz; V. Duic; A. Ferrero; M. Finger; H. Fischer; G. Giacomini; M. Giorgi; B. Gobbo; R. Hagemann; F.H. Heinsius; F. Herrmann; K. Königsmann; D. Kramer; L. Lauser; S. Levorato; A. Maggiora; A. Martin; G. Menon; A. Mutter
RICH counters for PID in the high momentum domain and in large acceptance experiments require photon detectors covering extended surface of several square meters and able to accept Cherenkov photons in a wide angular range. An ideal approach is represented by gaseous photon detectors, which allow covering wide surfaces at affordable costs.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1991
R. Birsa; P. Ciliberti; S. Dalla Torre-Colautti; M. Lamanna; A. Martin; G. Menon; F. Tessarotto; A. Masoni; G. Puddu; M. Agnello; Felice Iazzi; N. De Marco; A. Musso; A. Piccotti; L. Simonetti
Abstract Eight thousand limited streamer tubes have been built for the antineutron detectors of experiment PS199 at LEAR, the Low-Energy Antiproton Ring at CERN. The tubes are arranged in vertical planes and each plane is equipped with two orthogonal sets of strips used as position-sensitive readout elements. The digital readout system is based on the new board “streamer interface” built by SGS. The construction and testing procedure are described, as well as the performances of the detector and the readout system in a test with cosmic rays.
Journal of Instrumentation | 2014
M.G. Alexeev; R. Birsa; F. Bradamante; A. Bressan; M Büchele; M. Chiosso; P. Ciliberti; S. Dalla Torre; S. Dasgupta; O. Denisov; V. Duic; M. Finger; H. Fischer; M. Giorgi; B. Gobbo; M. Gregori; F. Herrmann; K. Königsmann; S. Levorato; A. Maggiora; A. Martin; G. Menon; K Novakova; J. Novy; D. Panzieri; F. Pereira; C. A. Santos; G. Sbrizzai; P. Schiavon; S. Schopferer
The THicK GEM (THGEM) electron multipliers are derived from the GEM design, by scaling the geometrical parameters and changing the production technology. Small-size (a few cm2) detectors exhibit superb performance, while larger ones exhibit gain response and uniformity limitations. We have studied with a systematic approach several aspects concerning the material (type and thickness of the fibreglass plates) and the production procedure, in particular the cleaning and polishing stages. The net result is the production of large THGEM multipliers reproducing the performance of the small ones. We report in detail about the studies and the results.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2007
P. Abbon; M. Alekseev; H. Angerer; M. Apollonio; R. Birsa; P. Bordalo; F. Bradamante; A. Bressan; L. Busso; M. Chiosso; P. Ciliberti; M.L. Colantoni; S. Costa; S. Dalla Torre; T. Dafni; E. Delagnes; H. Deschamps; V. Diaz; N. Dibiase; V. Duic; W. Eyrich; D. Faso; A. Ferrero; M. Finger; H. Fischer; S. Gerassimov; M. Giorgi; B. Gobbo; R. Hagemann; D. von Harrach
Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2008
P. Abbon; M. Alexeev; H. Angerer; R. Birsa; P. Bordalo; F. Bradamante; A. Bressan; M. Chiosso; P. Ciliberti; M.L. Colantoni; T. Dafni; S. Dalla Torre; E. Delagnes; O. Denisov; H. Deschamps; V. Diaz; N. Dibiase; V. Duic; W. Eyrich; A. Ferrero; M. Finger; H. Fischer; S. Gerassimov; M. Giorgi; B. Gobbo; R. Hagemann; D. von Harrach; F.H. Heinsius; R. Joosten; B. Ketzer
10^6
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2003
Günter Baum; R. Birsa; F. Bradamante; A. Bressan; A. Chapiro; A. Cicuttin; P. Ciliberti; A. Colavita; S. Costa; M.L. Crespo; P. Cristaudo; S. Dalla Torre; V. Diaz; P. Fauland; F. Fratnik; M. Giorgi; B. Gobbo; R. Ijaduola; V. Kalinnikov; M. Lamanna; A. Martin; G. Menon; P. Pagano; P. Schiavon; F. Tessarotto; A. Zanetti
per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The new detection system consists of multi-anode photomultiplier tubes (MAPMT) and fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip. The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run. We present the photon detection design, constructive aspects and the first Cherenkov light in the detector.