Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where P. Voet is active.

Publication


Featured researches published by P. Voet.


Medical Physics | 2012

iCycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans

S. Breedveld; Pascal Storchi; P. Voet; B.J.M. Heijmen

PURPOSE To introduce iCycle, a novel algorithm for integrated, multicriterial optimization of beam angles, and intensity modulated radiotherapy (IMRT) profiles. METHODS A multicriterial plan optimization with iCycle is based on a prescription called wish-list, containing hard constraints and objectives with ascribed priorities. Priorities are ordinal parameters used for relative importance ranking of the objectives. The higher an objective priority is, the higher the probability that the corresponding objective will be met. Beam directions are selected from an input set of candidate directions. Input sets can be restricted, e.g., to allow only generation of coplanar plans, or to avoid collisions between patient/couch and the gantry in a noncoplanar setup. Obtaining clinically feasible calculation times was an important design criterium for development of iCycle. This could be realized by sequentially adding beams to the treatment plan in an iterative procedure. Each iteration loop starts with selection of the optimal direction to be added. Then, a Pareto-optimal IMRT plan is generated for the (fixed) beam setup that includes all so far selected directions, using a previously published algorithm for multicriterial optimization of fluence profiles for a fixed beam arrangement Breedveld et al. [Phys. Med. Biol. 54, 7199-7209 (2009)]. To select the next direction, each not yet selected candidate direction is temporarily added to the plan and an optimization problem, derived from the Lagrangian obtained from the just performed optimization for establishing the Pareto-optimal plan, is solved. For each patient, a single one-beam, two-beam, three-beam, etc. Pareto-optimal plan is generated until addition of beams does no longer result in significant plan quality improvement. Plan generation with iCycle is fully automated. RESULTS Performance and characteristics of iCycle are demonstrated by generating plans for a maxillary sinus case, a cervical cancer patient, and a liver patient treated with SBRT. Plans generated with beam angle optimization did better meet the clinical goals than equiangular or manually selected configurations. For the maxillary sinus and liver cases, significant improvements for noncoplanar setups were seen. The cervix case showed that also in IMRT with coplanar setups, beam angle optimization with iCycle may improve plan quality. Computation times for coplanar plans were around 1-2 h and for noncoplanar plans 4-7 h, depending on the number of beams and the complexity of the site. CONCLUSIONS Integrated beam angle and profile optimization with iCycle may result in significant improvements in treatment plan quality. Due to automation, the plan generation workload is minimal. Clinical application has started.


International Journal of Radiation Oncology Biology Physics | 2002

CAN ELECTIVE NODAL IRRADIATION BE OMITTED IN STAGE III NON-SMALL-CELL LUNG CANCER? ANALYSIS OF RECURRENCES IN A PHASE II STUDY OF INDUCTION CHEMOTHERAPY AND INVOLVED-FIELD RADIOTHERAPY

Suresh Senan; Sjaak Burgers; M.J. Samson; Rob J. van Klaveren; Swie Swat Oei; John R. van Sörnsen de Koste; P. Voet; Frank J. Lagerwaard; Jan Maarten van Haarst; Joachim Aerts; Jan P. van Meerbeeck

PURPOSE To establish the recurrence patterns when elective mediastinal irradiation was omitted, patients with Stage III non-small-cell lung cancer were treated with sequential chemotherapy (CHT) and involved-field radiotherapy (RT). METHODS AND MATERIALS Fifty patients were treated with either two or four cycles of induction CHT, followed by once-daily involved-field RT to 70 Gy, delivered using three-dimensional treatment planning. The contoured gross tumor volume consisted of the pre-CHT tumor volume and nodes with a short-axis diameter of > or = 1 cm. Patients were reevaluated at 3 and 6 months after RT using bronchoscopy and chest CT. Elective nodal failure was defined as recurrence in the regional nodes outside the clinical target volume, in the absence of in-field failure. RESULTS Of 43 patients who received doses > or = 50 Gy, 35% were disease free at last follow-up; in-field recurrences developed in 27% (of whom 16% had exclusively in-field recurrences); 18% had distant metastases exclusively. No elective nodal failure was observed. The median actuarial overall survival was 18 months (95% confidence interval 14-22) and the median progression-free survival was 12 months (95% confidence interval 6-18). CONCLUSION Omitting elective mediastinal irradiation did not result in isolated nodal failure. Future studies of concurrent CHT and RT for Stage III non-small-cell lung cancer should use involved-field RT to limit toxicity.


medical image computing and computer assisted intervention | 2008

Atlas-Based Auto-segmentation of Head and Neck CT Images

Xiao Han; Mischa S. Hoogeman; Peter C. Levendag; Lyndon S. Hibbard; David N. Teguh; P. Voet; Andrew C. Cowen; Theresa K. Wolf

Treatment planning for high precision radiotherapy of head and neck (H&N) cancer patients requires accurate delineation of many structures and lymph node regions. Manual contouring is tedious and suffers from large inter- and intra-rater variability. To reduce manual labor, we have developed a fully automated, atlas-based method for H&N CT image segmentation that employs a novel hierarchical atlas registration approach. This registration strategy makes use of object shape information in the atlas to help improve the registration efficiency and robustness while still being able to account for large inter-subject shape differences. Validation results showed that our method provides accurate segmentation for many structures despite difficulties presented by real clinical data. Comparison of two different atlas selection strategies is also reported.


Head and Neck-journal for The Sciences and Specialties of The Head and Neck | 2008

Trismus in patients with oropharyngeal cancer: relationship with dose in structures of mastication apparatus.

David N. Teguh; Peter C. Levendag; P. Voet; Henri van der Est; Inge Noever; Willy de Kruijf; Peter van Rooij; Paul I.M. Schmitz; B.J.M. Heijmen

Our aim was to assess the correlation between the radiation therapy (RT) dose to the mastication apparatus and trismus of oropharyngeal cancer patients.


International Journal of Radiation Oncology Biology Physics | 2014

Fully automated volumetric modulated arc therapy plan generation for prostate cancer patients

P. Voet; M. Dirkx; S. Breedveld; Abrahim Al-Mamgani; Luca Incrocci; B.J.M. Heijmen

PURPOSE To develop and evaluate fully automated volumetric modulated arc therapy (VMAT) treatment planning for prostate cancer patients, avoiding manual trial-and-error tweaking of plan parameters by dosimetrists. METHODS AND MATERIALS A system was developed for fully automated generation of VMAT plans with our commercial clinical treatment planning system (TPS), linked to the in-house developed Erasmus-iCycle multicriterial optimizer for preoptimization. For 30 randomly selected patients, automatically generated VMAT plans (VMATauto) were compared with VMAT plans generated manually by 1 expert dosimetrist in the absence of time pressure (VMATman). For all treatment plans, planning target volume (PTV) coverage and sparing of organs-at-risk were quantified. RESULTS All generated plans were clinically acceptable and had similar PTV coverage (V95% > 99%). For VMATauto and VMATman plans, the organ-at-risk sparing was similar as well, although only the former plans were generated without any planning workload. CONCLUSIONS Fully automated generation of high-quality VMAT plans for prostate cancer patients is feasible and has recently been implemented in our clinic.


International Journal of Radiation Oncology Biology Physics | 2009

Early Hyperbaric Oxygen Therapy for Reducing Radiotherapy Side Effects: Early Results of a Randomized Trial in Oropharyngeal and Nasopharyngeal Cancer

David N. Teguh; Peter C. Levendag; Inge Noever; P. Voet; Henrie van der Est; Peter van Rooij; Antoine G. Dumans; Maarten F. de Boer; Michiel P.C. van der Huls; Wouter Sterk; Paul I.M. Schmitz

PURPOSE Comparison of quality of life (QoL) and side effects in a randomized trial for early hyperbaric oxygen therapy (HBOT) after radiotherapy (RT). METHODS AND MATERIALS From 2006, 19 patients with tumor originating from the tonsillar fossa and/or soft palate (15), base of tongue (1), and nasopharynx (3) were randomized to receive HBOT or not. HBOT consisted of 30 sessions at 2.5 ATA (15 msw) with oxygen breathing for 90 min daily, 5 days per week, applied shortly after the RT treatment was completed. As of 2005, all patients received validated questionnaires (i.e., the European Organization for Research and Treatment of Cancer [EORTC] QLQ-C30, EORTC QLQ Head and Neck Cancer Module (H&N35), Performance Status Scale): before treatment; at the start of RT treatment; after 46 Gy; at the end of RT treatment; and 2, 4, and 6 weeks and 3, 6, 12, and 18 months after follow-up. RESULTS On all QoL items, better scores were obtained in patients treated with hyperbaric oxygen. The difference between HBOT vs. non-HBOT was significant for all parameters: EORTC H&N35 Swallowing (p = 0.011), EORTC H&N35 Dry Mouth (p = 0.009), EORTC H&N35, Sticky Saliva (p = 0.01), PSS Eating in Public (p = 0.027), and Pain in Mouth (visual analogue scale; p < 0.0001). CONCLUSIONS Patients randomized for receiving hyperbaric oxygen after the RT had better QoL scores for swallowing, sticky saliva, xerostomia, and pain in mouth.


Radiotherapy and Oncology | 2008

Results of fiberoptic endoscopic evaluation of swallowing vs. radiation dose in the swallowing muscles after radiotherapy of cancer in the oropharynx

David N. Teguh; Peter C. Levendag; Aniel Sewnaik; Marieke M. Hakkesteegt; Inge Noever; P. Voet; Henrie van der Est; Dick Sipkema; Peter van Rooij; Robert J. Baatenburg de Jong; Paul I.M. Schmitz

BACKGROUND AND PURPOSE Dysphagia is a serious complaint but frequently underreported. This paper assesses for oropharyngeal cancer (OPC) the relationship between the dose received by the swallowing structures, and the findings of a fiberoptic endoscopic evaluation of the swallowing process (FEES). MATERIALS AND METHODS Between 2000 and 2005, 60 of 67 OPC patients local-regionally NED for at least one year following treatment responded to three types of QoL questionnaires; i.e. Performance Status Scales, EORTC H&N35, and M.D. Anderson Dysphagia Inventory. Twenty-four patients agreed to the FEES procedure. The main swallowing muscles were delineated, with the mean dose per muscle calculated using the original 3D CT-based treatment plans. Regression analysis was performed between FEES variables and the doses in the different swallowing muscles and the dysphagia related questionnaires. RESULTS A significant relationship was found between the results of FEES and the mean dose in the superior constrictor muscle (SCM). Some of the subjective dysphagia complaints were significantly correlated with the FEES variables in this retrospectively study. CONCLUSION A higher dose in the SCM generally results in worsening of the findings obtained by the FEES examination.


Radiotherapy and Oncology | 2015

Comparison of VMAT and IMRT strategies for cervical cancer patients using automated planning

A.W. Sharfo; P. Voet; S. Breedveld; Jan Willem M. Mens; Mischa S. Hoogeman; B.J.M. Heijmen

BACKGROUND AND PURPOSE In a published study on cervical cancer, 5-beam IMRT was inferior to single arc VMAT. Here we compare 9, 12, and 20 beam IMRT with single and dual arc VMAT. MATERIAL AND METHODS For each of 10 patients, automated plan generation with the in-house Erasmus-iCycle optimizer was used to assist an expert planner in generating the five plans with the clinical TPS. RESULTS For each patient, all plans were clinically acceptable with a high and similar PTV coverage. OAR sparing increased when going from 9 to 12 to 20 IMRT beams, and from single to dual arc VMAT. For all patients, 12 and 20 beam IMRT were superior to single and dual arc VMAT, with substantial variations in gain among the study patients. As expected, delivery of VMAT plans was significantly faster than delivery of IMRT plans. CONCLUSIONS Often reported increased plan quality for VMAT compared to IMRT has not been observed for cervical cancer. Twenty and 12 beam IMRT plans had a higher quality than single and dual arc VMAT. For individual patients, the optimal delivery technique depends on a complex trade-off between plan quality and treatment time that may change with introduction of faster delivery systems.


Acta Oncologica | 2013

A margin-of-the-day online adaptive intensity-modulated radiotherapy strategy for cervical cancer provides superior treatment accuracy compared to clinically recommended margins: A dosimetric evaluation

R. Ahmad; L. Bondar; P. Voet; Jan Willem M. Mens; S. Quint; G. Dhawtal; B.J.M. Heijmen; Mischa S. Hoogeman

Abstract Purpose. To dosimetrically evaluate a margin-of-the-day (MoD) online adaptive intensity-modulated radiotherapy (IMRT) strategy for cervical cancer patients. The strategy is based on a single planning computed tomography (CT) scan and a pretreatment constructed IMRT plan library with incremental clinical target volumes (CTV)-to-planning target volumes (PTV) margins. Material and methods. For 14 patients, 9–10 variable bladder filling CT scans acquired at pretreatment and after 40 Gy were available. Bladder volume variability during the treatment course was recorded by twice-weekly US bladder-volume measurements. A MoD strategy that selects the best IMRT plan of the day from a library of plans with incremental margins in steps of 5 mm was compared with a clinically recommended population-based margin (15 mm). To compare the strategies, for each fraction that had a recorded US bladder-volume measurement, the CT scan with the nearest bladder volume was selected from the pretreatment CT series and from the CT series acquired after 40 Gy. A frequency-weighted average of the dose-volume histograms (DVH) parameters calculated for the two selected CT scans was used to estimate the DVH parameters of the fraction of interest. Results. The 15-mm recommended margin resulted in cervix-uterus underdosage in six of 14 patients. Compared with the 15-mm margin, the MoD strategy resulted in significantly better cervix-uterus coverage (p = 0.008) without a significant difference in the sparing of rectum, bladder, and small bowel. For each patient, 3–8 (median 5) plans were needed in the library of plans for the MoD strategy. The required range of the MoD was 5–45 mm (median 15 mm). Twenty-five percent of all fractions could be treated with a MoD of 5 mm and 81% of all fractions could be treated with a MoD up to 25 mm. Conclusions. Compared with a clinically recommended margin, a simple online adaptive strategy resulted in better cervix-uterus coverage without compromising organs at risk sparing.


International Journal of Radiation Oncology Biology Physics | 2012

IMRT for image-guided single vocal cord irradiation

Sarah O.S. Osman; Eleftheria Astreinidou; Hans C.J. de Boer; Fatma Keskin-Cambay; S. Breedveld; P. Voet; Abrahim Al-Mamgani; B.J.M. Heijmen; Peter C. Levendag

PURPOSE We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. METHODS AND MATERIALS For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. RESULTS For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose ± standard deviation to the planning target volume was 67 ± 1 Gy. The contralateral vocal cord dose was reduced from 66 ± 1 Gy in the conventional plans to 39 ± 8 Gy and 36 ± 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. CONCLUSIONS Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.

Collaboration


Dive into the P. Voet's collaboration.

Top Co-Authors

Avatar

B.J.M. Heijmen

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

S. Breedveld

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Peter C. Levendag

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

David N. Teguh

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

M. Dirkx

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Mischa S. Hoogeman

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Paul I.M. Schmitz

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

A.W. Sharfo

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

D. Fransen

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Abrahim Al-Mamgani

Erasmus University Rotterdam

View shared research outputs
Researchain Logo
Decentralizing Knowledge