Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Pallavi Daggumati is active.

Publication


Featured researches published by Pallavi Daggumati.


Scientific Reports | 2013

Fabrication and Characterization of Flexible and Tunable Plasmonic Nanostructures

Mehmet Kahraman; Pallavi Daggumati; Ozge Kurtulus; Erkin Seker; Sebastian Wachsmann-Hogiu

We present a novel method to fabricate flexible and tunable plasmonic nanostructures based on combination of soft lithography and nanosphere lithography, and perform a comprehensive structural and optical characterization of these structures. Spherical latex particles are uniformly deposited on glass slides and used as molds for polydimethylsiloxane to obtain nanovoid structures. The diameter and depth of the nanostructures are controlled by the size of the latex particles. These surfaces are coated with a thin Ag layer for fabrication of uniform plasmonic nanostructures. Structural characterization of these surfaces is performed by SEM and AFM. Optical properties of these plasmonic nanostructures are evaluated via UV/Vis absorption spectroscopy, dark field microscopy, and surface–enhanced Raman spectroscopy (SERS). Position of the surface plasmon absorption depends on the diameter and depth of the nanostructures. SERS enhancement factor (measured up to 1.4 × 106) is dependent on the plasmon absorption wavelength and laser wavelength used in these experiments.


Analytical Chemistry | 2015

Effect of Nanoporous Gold Thin Film Morphology on Electrochemical DNA Sensing

Pallavi Daggumati; Zimple Matharu; Erkin Seker

Advances in materials science and chemistry have led to the development of a wide range of nanostructured materials for building novel electrochemical biosensors. A systematic understanding of the challenges related to electrode morphology involved in designing such sensors is essential for developing effective biosensing tools. In this study, we use nanoporous gold (np-Au) thin film electrode coatings with submicrometer thicknesses, as a model system to investigate the influence of nanostructuring on DNA-methylene blue (MB) interactions and their application to DNA biosensors. The interaction of single- and double-stranded DNA immobilized onto morphologically different np-Au films with MB was electrochemically interrogated via square wave voltammetry (SWV). The electrochemical signal from these electrodes in response to MB decayed progressively with each SWV scan. The decay rate was governed by accessibility of the electrochemically active np-Au surface by the analyte. The optimum frequency for extracting the maximum signal via SWV was influenced by the film morphology, where the optimum frequency was lower for the nanoporous morphology with lower density of molecular access points into the porous coating. Overall, the np-Au electrodes exhibited a 10-fold enhancement in probe grafting density and approximately 10-fold higher electrochemical current upon probe-target hybridization as compared to the planar Au electrodes. The np-Au electrodes enabled sensitive detection with a dynamic range of 10 to 100 nM that shifts by 1 order of magnitude for coarsened np-Au morphology due to increased target penetration into the porous network and hence enhanced hybridization efficiency. These findings provide insight into the influence of nanostructuring on the transport mechanisms of small molecules and nucleic acids, and yield an understanding of diverse sensor performance parameters such as DNA grafting density, hybridization efficiency, sensitivity and dynamic range.


Analytical Chemistry | 2015

Biofouling-Resilient Nanoporous Gold Electrodes for DNA Sensing

Pallavi Daggumati; Zimple Matharu; Ling Wang; Erkin Seker

Electrochemical nucleic acid sensors are promising tools for point-of-care diagnostic platforms with their facile integration with electronics and scalability. However, nucleic acid detection in complex biological fluids is challenging as biomolecules nonspecifically adsorb on the electrode surface and adversely affect the sensor performance by obscuring the transport of analytes and redox species to the electrode. We report that nanoporous gold (np-Au) electrodes, prepared by a microfabrication-compatible self-assembly process and functionalized with DNA probes, enabled detection of target DNA molecules (10-200 nM) in physiologically relevant complex media (bovine serum albumin and fetal bovine serum). In contrast, the sensor performance was compromised for planar gold electrodes in the same conditions. Hybridization efficiency decreased by 10% for np-Au with coarser pores revealing a pore-size dependence of sensor performance in biofouling conditions. This nanostructure-dependent functionality in complex media suggests that the pores with the optimal size and geometry act as sieves for blocking the biomolecules from inhibiting the surfaces within the porous volume while allowing the transport of nucleic acid analytes and redox molecules.


Journal of the American Chemical Society | 2016

Sequence-Specific Electrical Purification of Nucleic Acids with Nanoporous Gold Electrodes.

Pallavi Daggumati; Sandra Appelt; Zimple Matharu; Maria L. Marco; Erkin Seker

Nucleic-acid-based biosensors have enabled rapid and sensitive detection of pathogenic targets; however, these devices often require purified nucleic acids for analysis since the constituents of complex biological fluids adversely affect sensor performance. This purification step is typically performed outside the device, thereby increasing sample-to-answer time and introducing contaminants. We report a novel approach using a multifunctional matrix, nanoporous gold (np-Au), which enables both detection of specific target sequences in a complex biological sample and their subsequent purification. The np-Au electrodes modified with 26-mer DNA probes (via thiol-gold chemistry) enabled sensitive detection and capture of complementary DNA targets in the presence of complex media (fetal bovine serum) and other interfering DNA fragments in the range of 50-1500 base pairs. Upon capture, the noncomplementary DNA fragments and serum constituents of varying sizes were washed away. Finally, the surface-bound DNA-DNA hybrids were released by electrochemically cleaving the thiol-gold linkage, and the hybrids were iontophoretically eluted from the nanoporous matrix. The optical and electrophoretic characterization of the analytes before and after the detection-purification process revealed that low target DNA concentrations (80 pg/μL) can be successfully detected in complex biological fluids and subsequently released to yield pure hybrids free of polydisperse digested DNA fragments and serum biomolecules. Taken together, this multifunctional platform is expected to enable seamless integration of detection and purification of nucleic acid biomarkers of pathogens and diseases in miniaturized diagnostic devices.


Journal of Visualized Experiments | 2013

Microfabrication of Nanoporous Gold Patterns for Cell-material Interaction Studies

Pallavi Daggumati; Ozge Kurtulus; Christopher A. R. Chapman; Damla Dimlioglu; Erkin Seker

Nanostructured materials with feature sizes in tens of nanometers have enhanced the performance of several technologies, including fuel cells, biosensors, biomedical device coatings, and drug delivery tools. Nanoporous gold (np-Au), produced by a nano-scale self-assembly process, is a relatively new material that exhibits large effective surface area, high electrical conductivity, and catalytic activity. These properties have made np-Au an attractive material to scientific community. Most studies on np-Au employ macro-scale specimens and focus on fundamental science of the material and its catalytic and sensor applications. The macro-scale specimens limit np-Aus potential in miniaturized systems, including biomedical devices. In order to address these issues, we initially describe two different methods to micropattern np-Au thin films on rigid substrates. The first method employs manually-produced stencil masks for creating millimeter-scale np-Au patterns, while the second method uses lift-off photolithography to pattern sub-millimeter-scale patterns. As the np-Au thin films are obtained by sputter-deposition process, they are compatible with conventional microfabrication techniques, thereby amenable to facile integration into microsystems. These systems include electrically-addressable biosensor platforms that benefit from high effective surface area, electrical conductivity, and gold-thiol-based surface bioconjugation. We describe cell culture, immunostaining, and image processing techniques to quantify np-Aus interaction with mammalian cells, which is an important performance parameter for some biosensors. We expect that the techniques illustrated here will assist the integration of np-Au in platforms at various length-scales and in numerous applications, including biosensors, energy storage systems, and catalysts.


ACS Applied Materials & Interfaces | 2017

Nanoporous-Gold-Based Electrode Morphology Libraries for Investigating Structure–Property Relationships in Nucleic Acid Based Electrochemical Biosensors

Zimple Matharu; Pallavi Daggumati; Ling Wang; Tatiana S. Dorofeeva; Zidong Li; Erkin Seker

Nanoporous gold (np-Au) electrode coatings significantly enhance the performance of electrochemical nucleic acid biosensors because of their three-dimensional nanoscale network, high electrical conductivity, facile surface functionalization, and biocompatibility. Contrary to planar electrodes, the np-Au electrodes also exhibit sensitive detection in the presence of common biofouling media due to their porous structure. However, the pore size of the nanomatrix plays a critical role in dictating the extent of biomolecular capture and transport. Small pores perform better in the case of target detection in complex samples by filtering out the large nonspecific proteins. On the other hand, larger pores increase the accessibility of target nucleic acids in the nanoporous structure, enhancing the detection limits of the sensor at the expense of more interference from biofouling molecules. Here, we report a microfabricated np-Au multiple electrode array that displays a range of electrode morphologies on the same chip for identifying feature sizes that reduce the nonspecific adsorption of proteins but facilitate the permeation of target DNA molecules into the pores. We demonstrate the utility of the electrode morphology library in studying DNA functionalization and target detection in complex biological media with a special emphasis on revealing ranges of electrode morphologies that mutually enhance the limit of detection and biofouling resilience. We expect this technique to assist in the development of high-performance biosensors for point-of-care diagnostics and facilitate studies on the electrode structure-property relationships in potential applications ranging from neural electrodes to catalysts.


Nanomaterials | 2018

Electrically Guided DNA Immobilization and Multiplexed DNA Detection with Nanoporous Gold Electrodes

Jovana Veselinovic; Zidong Li; Pallavi Daggumati; Erkin Seker

Molecular diagnostics have significantly advanced the early detection of diseases, where the electrochemical sensing of biomarkers (e.g., DNA, RNA, proteins) using multiple electrode arrays (MEAs) has shown considerable promise. Nanostructuring the electrode surface results in higher surface coverage of capture probes and more favorable orientation, as well as transport phenomena unique to nanoscale, ultimately leading to enhanced sensor performance. The central goal of this study is to investigate the influence of electrode nanostructure on electrically-guided immobilization of DNA probes for nucleic acid detection in a multiplexed format. To that end, we used nanoporous gold (np-Au) electrodes that reduced the limit of detection (LOD) for DNA targets by two orders of magnitude compared to their planar counterparts, where the LOD was further improved by an additional order of magnitude after reducing the electrode diameter. The reduced electrode diameter also made it possible to create a np-Au MEA encapsulated in a microfluidic channel. The electro-grafting reduced the necessary incubation time to immobilize DNA probes into the porous electrodes down to 10 min (25-fold reduction compared to passive immobilization) and allowed for grafting a different DNA probe sequence onto each electrode in the array. The resulting platform was successfully used for the multiplexed detection of three different biomarker genes relevant to breast cancer diagnosis.


Nanoscale | 2014

Molecular release from patterned nanoporous gold thin films

Ozge Kurtulus; Pallavi Daggumati; Erkin Seker


Scripta Materialia | 2016

Substrate topography guides pore morphology evolution in nanoporous gold thin films

Christopher A. R. Chapman; Pallavi Daggumati; Shannon C. Gott; Masaru P. Rao; Erkin Seker


Journal of Physical Chemistry C | 2016

Electrochemically Triggered Pore Expansion in Nanoporous Gold Thin Films

Tatiana S. Dorofeeva; Zimple Matharu; Pallavi Daggumati; Erkin Seker

Collaboration


Dive into the Pallavi Daggumati's collaboration.

Top Co-Authors

Avatar

Erkin Seker

University of California

View shared research outputs
Top Co-Authors

Avatar

Zimple Matharu

University of California

View shared research outputs
Top Co-Authors

Avatar

Ling Wang

University of California

View shared research outputs
Top Co-Authors

Avatar

Ozge Kurtulus

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Zidong Li

University of California

View shared research outputs
Top Co-Authors

Avatar

Maria L. Marco

University of California

View shared research outputs
Top Co-Authors

Avatar

Masaru P. Rao

University of California

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge