Pär-Olov Östman
University of Gothenburg
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Pär-Olov Östman.
Clinical Implant Dentistry and Related Research | 2012
Pär-Olov Östman; Mats Hellman; Lars Sennerby
BACKGROUND Concerns have been raised that use of surface-modified implants may result in peri-implant infection and marked marginal bone loss over time. PURPOSE The aim of this prospective study was to evaluate the survival rate, marginal bone, and soft tissue conditions at surface-modified titanium dental implants after 10 years of function. MATERIAL AND METHODS Forty-six totally and partially edentulous patients were provided with 121 Brånemark oxidized implants (TiUnite™, Nobel Biocare AB, Gothenburg, Sweden). Twenty-four (20%) implants were immediate loaded and 97 (80%) were placed using a two-stage procedure. A total of 22 single, 23 partial, and 7 total restorations were delivered. Clinical and radiographic checkups were carried out after 3, 6, 12 months, and thereafter annually up to 10 years. At these occasions, oral hygiene was evaluated and peri-implant mucosa examined by probing. If needed, patients were enrolled in an individual program for hygiene controls and professional cleaning. Marginal bone loss was evaluated in intraoral radiographs taken at baseline and after 1, 5, and 10 years of function. RESULTS One (0.8%) implant failed after 8 years giving a Survival Rate (SR) of 99.2% after 10 years. A total of 11 sites (9.2%) showed bleeding on probing (BP) at the 10th annual checkup. The mean marginal bone loss was 0.7 ± 1.35 mm based on 106 readable pairs of radiographs from baseline and from the 10th annual examination. Twelve (11.3%) implants showed more than 2 mm bone loss, and five (4.7%) showed more than 3 mm of bone loss after 10 years. For the latter, all patients were smokers and had poor or acceptable oral hygiene. All five implants with >3 mm bone loss showed BP and two (1.9%) showed suppuration from the pocket. For the remaining seven implants with more than 2 mm bone loss, no correlation to smoking, oral hygiene, bleeding, or pus could be seen. Time/marginal bone level plots of the 12 implants with more than 2 mm bone loss after 10 years, showed minor changes from the first annual checkup except for the two infected implants. CONCLUSIONS It is concluded that good long-term clinical outcomes can be obtained with oxidized titanium dental implants. Only 1.9% of examined implants showed significant marginal bone loss together with bleeding and suppuration after 10 years of function.
Clinical Implant Dentistry and Related Research | 2010
Pär-Olov Östman; Ann Wennerberg; Tomas Albrektsson
BACKGROUND Recently, a new implant surface texture, featuring application of nanometer-scale calcium phosphate has been shown to enhance early bone fixation and formation in preclinical studies and in human histomorphometric studies, which may be beneficial in immediate loading situations. AIM The purpose of the present prospective clinical study was to, during 1 year, clinically and radiographically evaluate a nanometer scale surface modified implant placed for immediate loading of fixed prostheses in both maxillary and mandibular regions. MATERIALS AND METHODS Thirty-five out of 38 patients who needed implant treatment and met inclusion criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 25 Ncm prior to final seating and an implant stability quotient above 55. A total of 102 NanoTite PREVAIL (NTP) implants (BIOMET 3i, Palm Beach Gardens, FL, USA) (66 maxillary and 36 mandibular) were placed by one investigator, and the majority of these were placed in posterior regions (65%) and in soft bone (69%). A total of 44 prosthetic constructions were evaluated consisting of 14 single-tooth restorations, 26 fixed partial dentures, and four complete fixed restorations. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. Implants were monitored for clinical and radiographic outcomes at follow-up examinations scheduled for 3, 6, and 12 months. RESULTS Of the 102 study implants, one implant failed. The simple cumulative survival rate value at 1 year was 99.2%. The average marginal bone resorption was 0.37 mm (SD 0.39) during the first year in function. According to the success criteria of Albrektsson and Zarb, success grade 1 was found with 93% of the implants. CONCLUSION Although limited to the short follow-up, immediate loading of NanoTite Prevail implants seems to be a viable option in implant rehabilitation, at least when a good initial fixation is achieved.
Clinical Implant Dentistry and Related Research | 2009
Pär-Olov Östman; Markijan Hupalo; Robert Del Castillo; Robert W. Emery; Roberto Cocchetto; Giampaolo Vincenzi; Barry Wagenberg; Bruno Vanassche; Andreas Valentin; Gerard Clausen; Paul Hogan; R.J. Goené; Christopher F. Evans; Tiziano Testori
BACKGROUND Clinical studies reporting immediate loading of endosseous implants for edentulous cases and for fixed partial restorations have been well documented with satisfactory survival rates. Implants with a recently developed, nanometer-scale surface topography (NanoTite, BIOMET 3i, Palm Beach Gardens, FL, USA), created by discrete crystalline depositions (DCD) of calcium phosphate nano-crystals onto a dual acid-etched (DAE) surface, show enhanced early fixation in preclinical studies when compared with DAE-surfaced implants. These outcomes suggest DCD-surfaced implants may be advantageous for immediate loading approaches. OBJECTIVE The aim of this prospective, multicenter, observational study is to report clinical outcomes for DCD-surfaced implants placed in immediate functional support of single- and multi-unit restorations according to an immediate loading protocol. MATERIALS AND METHODS One hundred eighty-five patients enrolled at 15 international study centers received a total of 335 implants supporting 216 immediate provisionalizations consisting of 128 single-tooth restorations and 88 fixed restorations. Of the 335 implants, 77% are located in posterior and 23% in anterior regions with 55.5% of the total in mandibles and 44.5% in maxillae. Patients were evaluated for implant mobility, gingival health, symptomatology, and radiographic outcomes. RESULTS At the time of this 1-year interim report, a total of 17 failures have been observed in 11 patients, yielding a cumulative survival rate of 94.9%. CONCLUSION Relative to other prospective, multicenter studies of immediately loaded implants with various surface enhancements, NanoTite implants perform comparatively well when immediately provisionalized with single-tooth and fixed restorations.
Clinical Implant Dentistry and Related Research | 2013
Pär-Olov Östman; Ann Wennerberg; Annika Ekestubbe; Tomas Albrektsson
BACKGROUND During the last decade, high success rates have been reported for implants placed with immediate loading procedures, especially when bone quality and quantity provide good implant stability. In many of these studies, straight-walled implants with moderately rough surfaces were employed. Tapered implants are becoming increasingly more popular due to standardized drilling protocols and reports of high initial primary stability. PURPOSE The aim of the present prospective, single center clinical study was to evaluate surface topographical analysis and the clinical and radiographic outcomes of the NanoTite™ (BIOMET 3i, Palm Beach Gardens, FL, USA) Tapered Implant when used for immediate loading of fixed prostheses and single-tooth restorations. MATERIALS AND METHODS Forty-two patients who needed implant treatment and met admission criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 30 Ncm prior to final seating and an implant stability quotient above 55. A total of 139 NanoTite Tapered implants (112 maxillary and 27 mandibular) were placed by one investigator, and the majority of these implants (n = 77/55%) were placed in posterior regions, and in soft bone (n = 90/65%). A total of 57 prosthetic constructions were evaluated consisting of 20 single-tooth restorations, 30 fixed partial dentures, and 7 complete, fixed maxillary restorations. Radiographs were taken at baseline and at 12 months of follow-up. RESULTS Of the 139 study implants, one implant failure was declared. The overall cumulative survival rate at 1 year is 99.4%. Mean marginal bone resorption is 1.01 mm (SD 0.85) during the first year of function. CONCLUSION Although limited to the short follow-up, immediate loading of NanoTite Tapered implants seems to be a viable option in implant rehabilitation, when insertion torque of at least 30 Ncm is achieved. Further studies are needed to authenticate the finding of this study.
Clinical Implant Dentistry and Related Research | 2008
Pär-Olov Östman; Mats Hellman; Lars Sennerby; Ann Wennerberg
BACKGROUND During the last years, focus has been paid to implant treatment using immediate function protocols, and different approaches to provide patients with temporary constructions have been presented. Most of these techniques involve dental technicians producing the temporary construction, for example, rebuilding existing dentures, acrylic bridges, etc. PURPOSE The purpose of this prospective clinical study was to evaluate the clinical outcome of a chair-side technique of a cost-effective temporary prosthesis. Fixture survival rate and risk of temporary bridge failure were analyzed. MATERIALS AND METHODS Thirty-seven partially or totally edentate patients (18 female and 19 male; mean age: 66.7 years) treated with chair-side manufactured temporary restorations (QuickBridge, BIOMET 3i, Palm Beach, Fl, USA) for immediate loading have been evaluated. The prostheses extended from two unit bridges supported by two implants to full-arch construction supported by six implants. The temporary prostheses were monitored from the day of surgery and delivery to the time of replacement with a permanent prosthetic construction 3 to 6 months later. RESULTS No implants were lost during the observation time. One (3%) temporary prosthesis fractured and additional two (6%) loosened during the follow-up time. CONCLUSIONS The study indicated that the tested chair-side concept for manufacturing of temporary prosthesis for immediate loading of dental implants is a viable approach.
Clinical Implant Dentistry and Related Research | 2005
Pär-Olov Östman; Mats Hellman; Lars Sennerby
International Journal of Prosthodontics | 2006
Pär-Olov Östman; Mats Hellman; Wendelhag I; Lars Sennerby
International Journal of Oral & Maxillofacial Implants | 2008
Pär-Olov Östman; Mats Hellman; Lars Sennerby
Clinical Implant Dentistry and Related Research | 2005
Bertil Friberg; Christer Dahlin; Göran Widmark; Pär-Olov Östman; Camilla Billström
Clinical Implant Dentistry and Related Research | 2004
Pär-Olov Östman; Mats Hellman; Hans Nilson; Ingvar Ericsson