Patrick Stumpp
Leipzig University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Patrick Stumpp.
Oral Oncology | 2016
Alexey Surov; Patrick Stumpp; Hans Jonas Meyer; Matthias Gawlitza; Anne-Kathrin Höhn; Andreas Boehm; Osama Sabri; Thomas Kahn; Sandra Purz
OBJECTIVES To analyze possible associations between functional simultaneous (18)F-FDG-PET/MR imaging parameters and histopathological parameters in head and neck squamous cell carcinoma (HNSCC). MATERIAL AND METHODS 11 patients (2 female, 9 male; mean age 56.0years) with biopsy-proven primary HNSCC underwent simultaneous (18)F-FDG-PET/MRI with a dedicated head and neck protocol including diffusion weighted imaging. For each tumor, glucose metabolism was estimated with standardized uptake values (SUV) and diffusion restriction was calculated using apparent diffusion coefficients (ADC). The tumor proliferation index was estimated on Ki 67 antigen stained specimens. Cell count, total nucleic area, and average nucleic area were estimated in each case. Pearsons correlation coefficient was used to analyze possible associations between the estimated parameters. RESULTS The mean SUVmax value was 24.41±6.51, and SUVmean value 15.01±4.07. Mean values (×10(-3)mm(2)s(-1)) of ADC parameters were as follows: ADCmin: 0.65±0.20; ADCmean: 1.28±0.18; and ADCmax: 2.16±0.35. Histopathological analysis identified the following results: cell count 1069.82±388.66, total nucleic area 150771.09±61177.12μm(2), average nucleic area 142.90±57.27μm(2) and proliferation index 49.09±22.67%. ADCmean correlated with Ki 67 level (r=-0.728, p=0.011) and total nucleic area (r=-0.691, p=0.019) and tended to correlate with average nucleic area (r=-0.527, p=0.096). ADCmax correlated with Ki 67 level (r=-0.633, p=0.036). SUVmax also tended to correlate with average nucleic area (r=0.573, p=0.066). Combined parameter SUVmax/ADCmin correlated with average nucleic area (r=0.627, p=0.039). CONCLUSION ADC and SUV values showed significant correlations with different histopathological parameters and can be used as biological markers in HNSCC.
PLOS ONE | 2015
P. Brandmaier; Sandra Purz; K. Bremicker; M. Höckel; Henryk Barthel; Regine Kluge; Thomas Kahn; Osama Sabri; Patrick Stumpp
Objectives Previous non–simultaneous PET/MR studies have shown heterogeneous results about the correlation between standardized uptake values (SUVs) and apparent diffusion coefficients (ADCs). The aim of this study was to investigate correlations in patients with primary and recurrent tumors using a simultaneous PET/MRI system which could lead to a better understanding of tumor biology and might play a role in early response assessment. Methods We included 31 patients with histologically confirmed primary (n = 14) or recurrent cervical cancer (n = 17) who underwent simultaneous whole-body 18F-FDG-PET/MRI comprising DWI. Image analysis was performed by a radiologist and a nuclear physician who identified tumor margins and quantified ADC and SUV. Pearson correlations were calculated to investigate the association between ADC and SUV. Results 92 lesions were detected. We found a significant inverse correlation between SUVmax and ADCmin (r = -0.532, p = 0.05) in primary tumors as well as in primary metastases (r = -0.362, p = 0.05) and between SUVmean and ADCmin (r = -0.403, p = 0.03). In recurrent local tumors we found correlations for SUVmax and ADCmin (r = -0.747, p = 0.002) and SUVmean and ADCmin (r = -0.773, p = 0.001). Associations for recurrent metastases were not significant (p>0.05). Conclusions Our study demonstrates the feasibility of fast and reliable measurement of SUV and ADC with simultaneous PET/MRI. In patients with cervical cancer we found significant inverse correlations for SUV and ADC which could play a major role for further tumor characterization and therapy decisions.
PLOS ONE | 2015
Matthias Gawlitza; Sandra Purz; Klaus Kubiessa; Andreas Boehm; Henryk Barthel; Regine Kluge; Thomas Kahn; Osama Sabri; Patrick Stumpp
Objective To demonstrate the feasibility of simultaneous acquisition of 18F-FDG-PET, diffusion-weighted imaging (DWI) and T1-weighted dynamic contrast-enhanced MRI (T1w-DCE) in an integrated simultaneous PET/MRI in patients with head and neck squamous cell cancer (HNSCC) and to investigate possible correlations between these parameters. Methods 17 patients that had given informed consent (15 male, 2 female) with biopsy-proven HNSCC underwent simultaneous 18F-FDG-PET/MRI including DWI and T1w-DCE. SUVmax, SUVmean, ADCmean, ADCmin and K trans, k ep and v e were measured for each tumour and correlated using Spearman’s ρ. Results Significant correlations were observed between SUVmean and K trans (ρ = 0.43; p ≤ 0.05); SUVmean and k ep (ρ = 0.44; p ≤ 0.05); K trans and k ep (ρ = 0.53; p ≤ 0.05); and between k ep and v e (ρ = -0.74; p ≤ 0.01). There was a trend towards statistical significance when correlating SUVmax and ADCmin (ρ = -0.35; p = 0.08); SUVmax and K trans (ρ = 0.37; p = 0.07); SUVmax and k ep (ρ = 0.39; p = 0.06); and ADCmean and v e (ρ = 0.4; p = 0.06). Conclusion Simultaneous 18F-FDG-PET/MRI including DWI and T1w-DCE in patients with HNSCC is feasible and allows depiction of complex interactions between glucose metabolism, microcirculatory parameters and cellular density.
Translational Oncology | 2017
Alexey Surov; Hans Jonas Meyer; Matthias Gawlitza; Anne-Kathrin Höhn; Andreas Boehm; Thomas Kahn; Patrick Stumpp
BACKGROUND: Dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) can characterize perfusion and vascularization of tissues. DCE MRI parameters can differentiate between malignant and benign lesions and predict tumor grading. The purpose of this study was to correlate DCE MRI findings and various histopathological parameters in head and neck squamous cell carcinoma (HNSCC). PATIENTS AND METHODS: Sixteen patients with histologically proven HNSCC (11 cases primary tumors and in 5 patients with local tumor recurrence) were included in the study. DCE imaging was performed in all cases and the following parameters were estimated: Ktrans, Ve, Kep, and iAUC. The tumor proliferation index was estimated on Ki 67 antigen stained specimens. Microvessel density parameters (stained vessel area, total vessel area, number of vessels, and mean vessel diameter) were estimated on CD31 antigen stained specimens. Spearmans non-parametric rank sum correlation coefficients were calculated between DCE and different histopathological parameters. RESULTS: The mean values of DCE perfusion parameters were as follows: Ktrans 0.189 ± 0.056 min−1, Kep 0.390 ± 0.160 min−1, Ve 0.548 ± 0.119%, and iAUC 22.40 ± 12.57. Significant correlations were observed between Kep and stained vessel areas (r = 0.51, P = .041) and total vessel areas (r = 0.5118, P = .043); between Ve and mean vessel diameter (r = −0.59, P = .017). Cell count had a tendency to correlate with Ve (r = −0.48, P = .058). In an analysis of the primary HNSCC only, a significant inverse correlation between Ktrans and KI 67 was identified (r = −0.62, P = .041). Our analysis showed significant correlations between DCE parameters and histopathological findings in HNSCC.
PLOS ONE | 2014
Bettina Maiwald; Donald Lobsien; Thomas Kahn; Patrick Stumpp
Objectives To compare 64-slice contrast-enhanced computed tomography (CT) with 3-Tesla magnetic resonance imaging (MRI) using Gd-EOB-DTPA for the diagnosis of hepatocellular carcinoma (HCC) and evaluate the utility of diffusion-weighted imaging (DWI) in this setting. Methods 3-phase-liver-CT was performed in fifty patients (42 male, 8 female) with suspected or proven HCC. The patients were subjected to a 3-Tesla-MRI-examination with Gd-EOB-DTPA and diffusion weighted imaging (DWI) at b-values of 0, 50 and 400 s/mm2. The apparent diffusion coefficient (ADC)-value was determined for each lesion detected in DWI. The histopathological report after resection or biopsy of a lesion served as the gold standard, and a surrogate of follow-up or complementary imaging techniques in combination with clinical and paraclinical parameters was used in unresected lesions. Diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values were evaluated for each technique. Results MRI detected slightly more lesions that were considered suspicious for HCC per patient compared to CT (2.7 versus 2.3, respectively). ADC-measurements in HCC showed notably heterogeneous values with a median of 1.2±0.5×10−3 mm2/s (range from 0.07±0.1 to 3.0±0.1×10−3 mm2/s). MRI showed similar diagnostic accuracy, sensitivity, and positive and negative predictive values compared to CT (AUC 0.837, sensitivity 92%, PPV 80% and NPV 90% for MRI vs. AUC 0.798, sensitivity 85%, PPV 79% and NPV 82% for CT; not significant). Specificity was 75% for both techniques. Conclusions Our study did not show a statistically significant difference in detection in detection of HCC between MRI and CT. Gd-EOB-DTPA-enhanced MRI tended to detect more lesions per patient compared to contrast-enhanced CT; therefore, we would recommend this modality as the first-choice imaging method for the detection of HCC and therapeutic decisions. However, contrast-enhanced CT was not inferior in our study, so that it can be a useful image modality for follow-up examinations.
Oncotarget | 2017
Alexey Surov; Hans Jonas Meyer; Stefan Schob; Anne-Kathrin Höhn; Kristina Bremicker; Marc Exner; Patrick Stumpp; Sandra Purz
The purpose of this study was to analyze associations between apparent diffusion coefficient (ADC) and standardized uptake values (SUV) values and different histopathological parameters in uterine cervical cancer. 21 patients with primary uterine cervical cancer were involved into the study. All patients underwent a whole body simultaneous18F-FDG PET/MRI. Mean and maximum SUV were noted (SUVmean and SUVmax). In all tumors minimal, mean, and maximal ADC values (ADCmin, ADCmean, and ADCmax) were estimated. Combined parameters were calculated: SUVmax/SUVmean, ADCmin/ ADCmean, SUVmax/ADCmin and SUVmax/ADCmean. In all cases the diagnosis was confirmed histopathologically by tumor biopsy. Histological slices were stained by hematoxilin and eosin, MIB 1 monoclonal antibody, and p16. All histopathological images were digitalized and analyzed by using a ImageJ software 1.48v. The following parameters were estimated: cell count, proliferation index KI 67, total and average nucleic areas, epithelial and stromal areas. Spearmans correlation coefficient was used to analyze associations between ADC and SUV values and histological parameters. P values ≤ 0.05 were considered as statistically significant. ADCmin and ADCmin/ ADCmean were statistically significant lower in N positive tumors. KI 67 correlated statistically significant with SUVmax (r = 0.59, p = 0.005), SUVmean (0.45, p = 0.04), ADCmin (r = −0.48, p = 0.03), SUVmax/ADCmin (r = 0.71, p = 0.001), SUVmax/ADCmean (0.75, p = 0.001). SUVmax correlated well with epithelial area (r = 0.71, p = 0.001) and stromal areas (r = −0.71, p = 0.001). SUV values, ADCmin, SUVmax/ADCmin and SUVmax/ADCmean correlated statistically significant with KI 67 and can be used to estimate the proliferation potential of tumors. SUV values correlated strong with epithelial area of tumor reflected metabolic active areas.
Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2012
Patrick Stumpp; D. Gosch; Ac Kühn; I. Sorge; D. Weber; Lukas Lehmkuhl; Thomas Kahn; Hd Nagel
PURPOSE To study the effect of an automatic dose control (ADC) system with adequate noise characteristic on the individual perception of image noise and diagnostic acceptance compared to objectively measured image noise and the dose reductions achieved in a representative group of patients. MATERIALS AND METHODS In a retrospective study two matched cohorts of 20 patients each were identified: a manual cohort with exposure settings according to body size (small - regular - large) and an ADC cohort with exposure settings calculated by the ADC system (DoseRight 2.0™, Philips Healthcare). For each patient, 12 images from 6 defined anatomic levels from contrast-enhanced scans of chest and abdomen/pelvis were analyzed by 4 independent readers concerning image noise and diagnostic acceptance on a five-point Likert scale and evaluated for objectively measured image noise. Radiation exposure was calculated from recorded exposure data. RESULTS Use of the ADC system reduced the average effective dose for patients by 36 % in chest scans (3.2 vs. 4.9 mSv) and by 17 % in abdomen/pelvis scans (7.6 vs. 8.3 mSv). Average objective noise was slightly lower in the manual cohort (11.1 vs. 12.8 HU), correlating with a slightly better rating in subjective noise score (4.4 vs. 4.2). However, diagnostic acceptance was rated almost equal in both cohorts with excellent image quality (4.6 vs. 4.5). CONCLUSION Use of an ADC system with adequate noise characteristic leads to significant reductions in radiation exposure for patients while maintaining excellent image quality.
The Journal of Nuclear Medicine | 2016
Jeanette Fahnert; Sandra Purz; Jan-Sven Jarvers; Christoph-Eckhard Heyde; Henryk Barthel; Patrick Stumpp; Thomas Kahn; Osama Sabri; Benjamin Friedrich
The diagnosis of spondylodiskitis is often challenging. MRI is quite sensitive but lacks specificity, and distinction from erosive osteochondritis is often difficult. We sought to assess the diagnostic value of 18F-FDG PET combined with MRI (combined 18F-FDG PET/MRI) in patients with suspected spondylodiskitis and an inconclusive clinical or MRI presentation. Methods: In a prospective study, 30 patients with previous inconclusive MRI results and suspected spondylodiskitis underwent combined 18F-FDG PET/MRI, including precontrast and postcontrast standard spine MRI sequences. The image datasets were evaluated on dedicated workstations by 2 radiology residents and 1 board-certified nuclear medicine physician independently and then in consensus. Because of severe susceptibility artifacts, only 28 of 30 image datasets were evaluable, with a total of 29 regions of suspected spondylodiskitis. SUV ratios (affected disk/reference disk) were determined. The imaging results were compared with histopathology or clinical follow-up as a reference standard and subjected to statistical analysis. Results: The reference standards identified spondylodiskitis in 12 disks and excluded spondylodiskitis in 17 disks. For MRI alone, the sensitivity was 50%, the specificity was 71%, the positive predictive value was 54%, and the negative predictive value was 67%. Adding the PET data resulted in sensitivity, specificity, positive predictive value, and negative predictive value of 100%, 88%, 86%, and 100%, respectively. In a receiver operating characteristic curve analysis, an SUVmax ratio threshold of 2.1 resulted in 92% sensitivity and 88% specificity (area under the receiver operating characteristic curve, 0.95). Neither the level of C-reactive protein nor the leukocyte count at the time of PET/MRI was related to the reference standard diagnosis of spondylodiskitis. Conclusion: In patients with inconclusive clinical or MRI findings, the use of 18F-FDG PET/MRI significantly increased diagnostic certainty for the detection of spondylodiskitis.
Acta Radiologica | 2016
Marc Exner; Axel Kühn; Patrick Stumpp; Michael Höckel; Lars-Christian Horn; Thomas Kahn; Philipp Brandmaier
Background Imaging of cervical carcinoma remains challenging as local infiltration of surrounding tissues cannot always be discriminated safely. New imaging techniques, like diffusion-weighted imaging (DWI) have emerged, which could lead to a more sensitive tumor detection. Purpose To evaluate the benefits of DWI for determination of size, local infiltration, and tumor grading, in patients with primary and recurrent cervical cancer. Material and Methods In this prospective, study we enrolled 50 patients with primary (n = 35) and recurrent (n = 15) tumors. All patients underwent 3T magnetic resonance imaging (MRI) including conventional (e.g. T1/T2 ± fs ± contrast) sequences and DWI (b-values of 0, 50, 400, 800 s/mm2). All images were analyzed by three readers with different experience levels (1, 3, 6 years), who compared image quality, tumor delineation, dimensions, local infiltration, lymph node involvement, and quantified ADC values compared to the histopathological grading. Results Additional use of DWI resulted in significantly better (P < 0.001) tumor delineation for the least experienced reader, but not for experienced readers. Tumor dimensions were assessed almost equally (P > 0.05) in conventional sequences and DWI. Use of DWI led to an increase in sensitivity of infiltrated adjacent tissue (from 86% to 90%) and detection of lymph node metastases (from 47% to 67%). Quantitative assessment of carcinomas showed lower ADC values (P < 0.001) with significant inverse correlations between different grading levels. Conclusion Our study demonstrates the overall benefits using DWI in 3T MRI resulting in a higher reader confidence, sensitivity of tissue infiltration, and tumor-grading for cervical cancer.
The New England Journal of Medicine | 2013
Sandra Purz; Regine Kluge; Henryk Barthel; Frank Steinert; Patrick Stumpp; Thomas Kahn; Osama Sabri
This case report of a woman with an ectopic parathyroid adenoma suggests that simultaneous positron-emission tomography (PET) and MRI might be superior to PET-CT for lesion localization.