Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Paul B. Schwinberg is active.

Publication


Featured researches published by Paul B. Schwinberg.


Physical Review Letters | 1999

Past Electron-Positron g − 2 Experiments Yielded Sharpest Bound on CPT Violation for Point Particles

Hans Dehmelt; Richard Mittleman; R.S. Van Dyck; Paul B. Schwinberg

In our past experiments on a single electron and positron we measured the cyclotron and spin-cyclotron difference frequencies omega_c and omega_a and the ratios a = omega_a/ omega_c at omega_c = 141 Ghz for e^- and e^+ and later, only for e^-, also at 164 Ghz. Here, we do extract from these data, as had not done before, a new and very different figure of merit for violation of CPT symmetry, one similar to the widely recognized impressive limit |m_Kaon - m_Antikaon|/m_Kaon < 10^-18 for the K-mesons composed of two quarks. That expression may be seen as comparing experimental relativistic masses of particle states before and after the C, P, T operations had transformed particle into antiparticle. Such a similar figure of merit for a non-composite and quite different lepton, found by us from our Delta a = a^- - a^+ data, was even smaller, h_bar |omega_a^- - omega_a^+|/2m_0 c^2 = |Delta a| h_bar omega_c/2m_0 c^2) < 3(12) 10^-22.


Physics Letters A | 1981

Trapping and thermalization of positrons for geonium spectroscopy

Paul B. Schwinberg; R.S. Van Dyck; Hans Dehmelt

Abstract A static technique for continuously catching positrons in a Penning trap under ultra-high vacuum conditions has been demonstrated and a preliminary measurement of the positron/electron mass ratio was made yielding m(e+)/m(e)- = 1 ± 1.3 × 10−7.


International Journal of Mass Spectrometry and Ion Processes | 1985

New measurement of the proton-electron mass ratio

R.S. Van Dyck; F. L. Moore; Dean L. Farnham; Paul B. Schwinberg

Abstract Using a compensated quadring Penning trap operated in a high magnetic field (5.05 T) at cryogenic temperatures (4.2 K), an r.f. resonance ion storage technique allows cyclotron resonances for both electrons and protons, alternately trapped in the same magnetic well, to be compared in order to yield the proton-electron mass ratio m p / m e = 1836.152470(76). The 41 p.p.b. uncertainty primarily reflects a systematic shift which arises from the two charge types not having the same average magnetron orbit.


Review of Scientific Instruments | 1999

Ultrastable superconducting magnet system for a penning trap mass spectrometer

R.S. Van Dyck; Dean L. Farnham; Steven L. Zafonte; Paul B. Schwinberg

A custom-designed magnet/cryostat system is described which has demonstrated remarkably improved field stability over previous designs. To shield from external magnetic noise, a custom-fabricated flux-gate device remotely senses the changes in magnetic field and cancels them out at the site of the magnet/cryostat via a 1.7-m-diam Helmholtz coil. To provide further shielding, the basic superconducting solenoid includes a passive flux-stabilizing coil. To stabilize internal field shifts, the temperature of the materials in the immediate vicinity of the solenoid (which have a temperature-dependent susceptibility) is stabilized via the new cryostat geometry and by controlling the pressure of the evaporating liquid helium to a few parts per million. As a result, the total system now has a composite shielding factor of approximately 104 and an overall temporal stability on the order of 17(2) parts in 1012 per hour. This instrument, the heart of our new Penning trap mass spectrometer, has recently been used to d...


Hyperfine Interactions | 2001

Ultra-Precise Mass Measurements Using the UW-PTMS

S Robert Van DyckJr.; Steven L. Zafonte; Paul B. Schwinberg

Based on the use of a single ion, isolated at the center of a cryogenically cooled Penning trap, an environment is produced which makes this mass spectrometer remarkably free of systematic errors. The most notable developments in our quest for an ultra-high accuracy instrument were (a) the compensation of the trapping potential, (b) the discovery that motional sidebands could manipulate radial energies, (c) the use of multiply-charged ions that could improve signal-to-noise, and (d) the use of an ultra-stable superconducting magnet/cryostat system with drift <0.010 ppb/h. The dominant systematic errors are associated with radial electric fields caused by image charges in the trap electrodes and with the rf-electrical drive field used to determine the harmonic axial resonance. To illustrate the potential of this improved spectrometer, the four-fold improved measurement of the protons mass and the eight-fold improved measurement of oxygens atomic mass will be described.


Journal of Modern Optics | 1992

A Compensated Penning Trap Mass Spectrometer and the 3

R.S. Van Dyck; Dean L. Farnham; Paul B. Schwinberg

Abstract The use of a compensated Penning trap to measure an ions mass relative to some calibration ion is described along with the leading systematic effects which must be considered. In this respect, magnet stability should no longer be a major limitation. This particular spectrometer has recently been used to determine preliminary atomic masses of both 3H and 3He and can be combined to yield a preliminary endpoint energy for the tritium decay (relative to neutral ground states) of 18 588(10) eV.


Trapped charged particles and fundamental physics | 1999

High precision Penning trap mass spectroscopy and a new measurement of the proton’s “atomic mass”

Robert S. Van Dyck; Dean L. Farnham; Steven L. Zafonte; Paul B. Schwinberg

The Penning trap mass spectrometer (PTMS) at the University of Washington has been rebuilt into a new state-of-the-art magnet/cryostat system with external Helmholtz compensation coils (controlled by a nearby flux-gate sensor). This system gives a total magnetic shielding factor of ∼104 (which includes the effects of a passive internal flux-stabilizing coil supplied by the manufacturer). When the new magnet/cryostat is fitted with a system to control its boil-off pressure, the typical temporal field stability is ∼−0.017(2) ppb/h. The ultimate resolution of this improved spectrometer is expected to exceed 0.020 ppb with 100 hours of data using a single C4+ ion. The comparison of a C4+ ion with a C5+ ion suggests that the spectrometer’s accuracy may indeed match its resolution. To demonstrate the spectrometer’s improved performance over its previous version, the cyclotron frequency of a single proton is compared to the corresponding frequency of a single C4+ ion, yielding a determination of the proton’s ato...


Physica Scripta | 1992

Progress on the 3H-3He mass difference using the compensated Penning trap spectrometer

R.S. Van Dyck; Dean L. Farnham; Paul B. Schwinberg

The use of the compensated Penning trap to measure an ions mass relative to some calibration ion is described along with the leading systematic effects which must be considered. In this respect, magnet stability should no longer be a major limitation. Sideband techniques are described that center ions in the trap and equilibrate the cyclotron motion. The spectrometers accuracy has been checked at the 1-ppb level by comparing the same atom with different charge states. The present application determines preliminary atomic masses of both 3H and 3He. These can be combined to yield an endpoint energy for the tritium decay (relative to neutral ground states) of 18 588(10)eV.


Review of Scientific Instruments | 1986

Variable magnetic bottle for precision geonium experiments

R.S. Van Dyck; F. L. Moore; Dean L. Farnham; Paul B. Schwinberg

A novel technique has been developed which allows a quadratic magnetic field to be continuously varied (via a superconducting flux transformer) from the outside of an ultrahigh‐vacuum container placed within a superconducting solenoid. Enclosed within each of these vacuum vessels is a high‐precision (compensated) Penning trap which is used in a variety of geonium experiments at the University of Washington. By varying the dc current in an outer (normal) primary solenoid, the secondary current flowing within a shorted superconducting loop is varied accordingly. The superconducting loop need only be placed in a cylindrically symmetric position within the Penning trap in order to generate the B2 term, and with a clever choice of geometry, the zeroth‐order term can be totally eliminated. As an additional highlight, the uniform field from the main solenoid is drift stabilized to the same degree as the basic cancellation and further, an auxiliary trim coil can be used to fine trim the zeroth‐order null.


Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 1989

Physics accessible through ultrahigh resolution trapped ion mass spectroscopy

F. L. Moore; Dean L. Farnham; Paul B. Schwinberg; R.S. Van Dyck

Abstract We describe how precision mass spectroscopy can test fundamental physics such as QED and CPT invariance. We also describe how mass spectroscopy can measure a variety of fundamental constants. This is followed by a brief description of the University of Washingtons compensated quadring Penning trap and a compilation of the current mass measurements it has taken.

Collaboration


Dive into the Paul B. Schwinberg's collaboration.

Top Co-Authors

Avatar

R.S. Van Dyck

University of Washington

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hans Dehmelt

University of Washington

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

F. L. Moore

University of Washington

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

G. Janik

University of Washington

View shared research outputs
Top Co-Authors

Avatar

K. Helmerson

University of Washington

View shared research outputs
Researchain Logo
Decentralizing Knowledge