Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Paul S. Addison is active.

Publication


Featured researches published by Paul S. Addison.


Anesthesiology Research and Practice | 2014

Calculation of the Respiratory Modulation of the Photoplethysmogram (DPOP) Incorporating a Correction for Low Perfusion

Paul S. Addison; Rui Wang; Scott McGonigle; Alberto A. Uribe; Sergio D. Bergese

DPOP quantifies respiratory modulations in the photoplethysmogram. It has been proposed as a noninvasive surrogate for pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. The correlation between DPOP and PPV may degrade due to low perfusion effects. We implemented an automated DPOP algorithm with an optional correction for low perfusion. These two algorithm variants (DPOPa and DPOPb) were tested on data from 20 mechanically ventilated OR patients split into a benign “stable region” subset and a whole record “global set.” Strong correlation was found between DPOP and PPV for both algorithms when applied to the stable data set: R = 0.83/0.85 for DPOPa/DPOPb. However, a marked improvement was found when applying the low perfusion correction to the global data set: R = 0.47/0.73 for DPOPa/DPOPb. Sensitivities, Specificities, and AUCs were 0.86, 0.70, and 0.88 for DPOPa/stable region; 0.89, 0.82, and 0.92 for DPOPb/stable region; 0.81, 0.61, and 0.73 for DPOPa/global region; 0.83, 0.76, and 0.86 for DPOPb/global region. An improvement was found in all results across both data sets when using the DPOPb algorithm. Further, DPOPb showed marked improvements, both in terms of its values, and correlation with PPV, for signals exhibiting low percent modulations.


Archive | 2013

METHODS AND SYSTEMS FOR DETERMINING A PROBE-OFF CONDITION IN A MEDICAL DEVICE

Paul S. Addison; James N. Watson


Archive | 2010

Simultaneous measurement of pulse and regional blood oxygen saturation

Youzhi Li; Bo Chen; Edward M. McKenna; Paul S. Addison


Archive | 2013

Systems and methods for identifying patient distress based on a sound signal

James N. Watson; Paul S. Addison


Archive | 2015

System and method for detecting fluid responsiveness of a patient

Mark Su; James N. Watson; Paul S. Addison


Archive | 2013

Systems and methods for monitoring blood pressure

James N. Watson; Keith Manning; Paul S. Addison


Archive | 2012

Methods and systems for determining signal quality of a physiological signal

Paul S. Addison; James N. Watson


Archive | 2014

SYSTEM AND METHOD FOR SCALING A FLUID RESPONSIVENESS METRIC

Paul S. Addison; Rui Wang; Scott McGonigle; James N. Watson


Archive | 2013

System and method for disinfecting and charging a sensor

Paul S. Addison; James N. Watson; James Dripps; George Keith Manning


Archive | 2012

System and method for determining stroke volume of a patient

Paul S. Addison; James N. Watson

Collaboration


Dive into the Paul S. Addison's collaboration.

Top Co-Authors

Avatar

James N. Watson

Mansfield University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Scott McGonigle

Mansfield University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Rui Wang

Mansfield University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Dean Montgomery

Mansfield University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Michael L. Mestek

Mansfield University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

James Ochs

Mansfield University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bo Chen

Mansfield University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Edward M. McKenna

Mansfield University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Peter Doyle

Mansfield University of Pennsylvania

View shared research outputs
Researchain Logo
Decentralizing Knowledge