Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Pawel Mekarski is active.

Publication


Featured researches published by Pawel Mekarski.


Applied Radiation and Isotopes | 2009

Monte Carlo simulation of a PhosWatch detector using Geant4 for xenon isotope beta-gamma coincidence spectrum profile and detection efficiency calculations.

Pawel Mekarski; Weihua Zhang; Kurt Ungar; Marc Bean; Ed Korpach

A simulation tool has been developed using the Geant4 Toolkit to simulate a PhosWatch single channel beta-gamma coincidence detection system consisting of a CsI(Tl)/BC404 Phoswich well detector and pulse shape analysis algorithms implemented digital signal processor. The tool can be used to simulate the detectors response for all the gamma rays and beta particles emitted from (135)Xe, (133m)Xe, (133)Xe, (131m)Xe and (214)Pb. Two- and three-dimensional beta-gamma coincidence spectra from the PhosWatch detector can be produced using the simulation tool. The accurately simulated spectra could be used to calculate system coincidence detection efficiency for each xenon isotope, the corrections for the interference from the various spectral components from radon and xenon isotopes, and system gain calibration. Also, it can generate two- and three-dimensional xenon reference spectra to test beta-gamma coincidence spectral deconvolution analysis software.


Applied Radiation and Isotopes | 2011

Quantification of 235U and 238U activity concentrations for undeclared nuclear materials by a digital gamma–gamma coincidence spectroscopy

Weihua Zhang; Jing Yi; Pawel Mekarski; Kurt Ungar; Barry M. Hauck; Gary H. Kramer

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of (235)U and (238)U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of (235)U and (238)U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional advantage of requiring minimal calibrations for (235)U and (238)U quantification at different sample geometries.


Applied Radiation and Isotopes | 2010

Beta-gamma coincidence counting efficiency and energy resolution optimization by Geant4 Monte Carlo simulations for a phoswich well detector.

Weihua Zhang; Pawel Mekarski; Kurt Ungar

A single-channel phoswich well detector has been assessed and analysed in order to improve beta-gamma coincidence measurement sensitivity of (131m)Xe and (133m)Xe. This newly designed phoswich well detector consists of a plastic cell (BC-404) embedded in a CsI(Tl) crystal coupled to a photomultiplier tube (PMT). It can be used to distinguish 30.0-keV X-ray signals of (131m)Xe and (133m)Xe using their unique coincidence signatures between the conversion electrons (CEs) and the 30.0-keV X-rays. The optimum coincidence efficiency signal depends on the energy resolutions of the two CE peaks, which could be affected by relative positions of the plastic cell to the CsI(Tl) because the embedded plastic cell would interrupt scintillation light path from the CsI(Tl) crystal to the PMT. In this study, several relative positions between the embedded plastic cell and the CsI(Tl) crystal have been evaluated using Monte Carlo modeling for its effects on coincidence detection efficiency and X-ray and CE energy resolutions. The results indicate that the energy resolution and beta-gamma coincidence counting efficiency of X-ray and CE depend significantly on the plastic cell locations inside the CsI(Tl). The degraded X-ray and CE peak energy resolutions due to light collection efficiency deterioration by the embedded cell can be minimised. The optimum of CE and X-ray energy resolution, beta-gamma coincidence efficiency as well as the ease of manufacturing could be achieved by varying the embedded plastic cell positions inside the CsI(Tl) and consequently setting the most efficient geometry.


Applied Radiation and Isotopes | 2013

Performance evaluation and optimization for a newly developed digital list-mode data acquisition Compton suppression spectrometer

Weihua Zhang; Benjamin Keeshan; Pawel Mekarski; Jing Yi; Kurt Ungar

A comparative study was carried out between an analog timing and a digital list-mode data acquisition system for a Compton suppression spectrometer. The performance of both Compton suppression systems has been evaluated using the conventional, coincidence and anticoincidence spectra measured by (60)Co and (137)Cs point sources. The present study focuses on improving and optimizing the energy peak resolution and peak-to-Compton background ratios of the digital list-mode system.


Journal of Radioanalytical and Nuclear Chemistry | 2012

Fukushima event reconstruction using modelling and isotope relationships

Ian Hoffman; Ed Korpach; Pawel Mekarski; Kurt Ungar; Jing Yi; Weihua Zhang; Mikael Moring; Vladimir Khotylev; Ali El-Jaby

Using particulate and noble gas raw data analysed from Comprehensive Nuclear Test-Ban-Treaty (CTBT) monitoring sites, Canadian National Surveillance networks and atmospheric transport modelling, it is possible to associate some of the main events in the Fukushima accident timeline with observations, and perturbations in isotopic ratios in Japan, through the Pacific and into North America. Additional sources identified during the accident period will be commented upon in the context of CTBT treaty verification.


Journal of Radioanalytical and Nuclear Chemistry | 2012

A digital Compton suppression spectroscopy without gamma-ray coincidence-summing loss using list-mode multispectral data acquisition

Weihua Zhang; Pawel Mekarski; Maxime Dion; Jing Yi; Kurt Ungar

The study demonstrates the advantages of an innovative list-mode multispectral data acquisition system that allows simultaneous creation of several different single, summed, coincident and anticoincident spectra with a single measurement. One of the consequences of list-mode data file offline processing is a reconstructed spectrum with Compton continuum suppression and without any full-energy peak efficiency deduction owing to true coincidence summing. The spectrometer is designed to read out analogue signal from preamplifier of gamma-ray detectors and to digitalize it using DGF/Pixie-4 software and card package (XIA LLC). This is realized by converting an Ortec Compton suppression data acquisition system into an all-digital spectrometer. Instead of using its timing electronic chain to determine the coincidence event, the analog signals from primary and guard detectors were connected directly into the Pixie-4 card for pulse height and time coincident measurement by individually logging and time stamping each electronic pulse. The data acquired in list-mode included coincidence and anticoincidence events consisting of records of energy and timestamp from primary and guard detectors. Every event was stored in a text file for offline processing and spectral reconstruction. A sophisticated computer simulation was also created with the goals of obtaining a better understanding of the experimental results and calculating efficiency.


Science and Technology of Nuclear Installations | 2011

An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations

Weihua Zhang; Pawel Mekarski; Marc Bean; Jing Yi; Kurt Ungar

An optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404) embedded in a CsI(Tl) crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI(Tl) crystal consists of a rectangular part and a semicylindrical scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15% improvement in the energy resolution of a 131mXe 129.4 keV conversion electron peak. The predicted beta-gamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.


Radiation Protection Dosimetry | 2014

Monte Carlo simulations of NaI(Tl) spectra for measurements of semi-infinite plumes.

Ed Korpach; Pawel Mekarski; R. Kurt Ungar

For the past 10 y Health Canada has operated a Fixed Point Surveillance Network of NaI(Tl) detectors across Canada. Deployed for both emergency response and daily monitoring of airborne radiation in the environment, a spectral stripping method allowed measurement of certain isotopes well below the ambient dose rate. These include (133)Xe, (135)Xe and (41)Ar, typical of emissions from operating nuclear reactors. In an effort to increase the number of isotopes measured at these low levels a new technique of spectral fitting using spectral templates is being implemented. However, this requires very accurate spectral templates that can be difficult or impossible to obtain empirically for environmental measurements of airborne radio-isotopes. Therefore, a method of efficiently using Monte Carlo techniques to create these templates was developed.


Journal of Radioanalytical and Nuclear Chemistry | 2009

Development of a phoswich detector system for radioxenon monitoring

Wolfgang Hennig; William K. Warburton; A. Fallu-Labruyere; Konstantin Sabourov; Matthew W. Cooper; Justin I. McIntyre; Anshel Gleyzer; Marc Bean; Ed Korpach; R. Kurt Ungar; Weihua Zhang; Pawel Mekarski


Journal of Radioanalytical and Nuclear Chemistry | 2011

A system for low-level the cosmogenic 22Na radionuclide measurement by gamma–gamma coincidence method using BGO detectors

Weihua Zhang; Jing Yi; Pawel Mekarski; Ian Hoffman; Kurt Ungar; Ari-Pekka Leppänen

Collaboration


Dive into the Pawel Mekarski's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge