Journal of Prosthodontics | 2012

Influence of low-temperature environmental exposure on the mechanical properties and structural stability of dental zirconia.

Tariq F. Alghazzawi; Jack E. Lemons; Perng-Ru Liu; Milton E. Essig; Alfred A. Bartolucci; Gregg M. Janowski

PURPOSE The effect of dental fabrication procedures of zirconia monolithic restorations and changes in properties during low-temperature exposure in the oral environment is not completely understood. The purpose of this study was to investigate the effect of procedures for fabrication of dental restorations by low-temperature simulation and relative changes of flexural strength, nanoindentation hardness, Youngs modulus, surface roughness, and structural stability of yttria-stabilized zirconia. MATERIALS AND METHODS A total of 64 zirconia specimens were prepared to simulate dental practice. The specimens were divided into the control group and the accelerated aging group. The simulated group followed the same procedure as the control group except for the aging treatment. Atomic force microscopy was used to measure surface roughness. The degree of tetragonal-to-monoclinic transformation was determined using X-ray diffraction. Nanoindentation hardness and modulus measurements were carried out on the surface of the zirconia specimens using a nanoindenter XP/G200 system. The yttria levels for nonaged and aged specimens were measured using energy dispersive spectroscopy. Flexural strength was determined using the piston-on-three-ball test. The t-test was used to determine statistical significance. RESULTS Means and standard deviations were calculated using all observations for each condition and evaluated using a group t-test (p < 0.05). The LTD treatment resulted in increased surface roughness (from 12.23 nm to 21.56 nm for Ra and 15.06 nm to 27.45 nm for RMS) and monoclinic phase fractions (from 2% to 21%), with a concomitant decrease in hardness (from 16.56 GPa to 15.14 GPa) and modulus (from 275.68 GPa to 256.56 GPa). Yttria content (from 4.43% to 4.46%) and flexural strength (from 586 MPa to 578 MPa) were not significantly altered, supporting longer term in vivo function without biomechanical fracture. CONCLUSION The LTD treatment induced the tetragonal-to-monoclinic transformation with surface roughening in zirconia prepared using dental procedures.


Journal of Prosthetic Dentistry | 2012

Evaluation of the optical properties of CAD-CAM generated yttria-stabilized zirconia and glass-ceramic laminate veneers

Tariq F. Alghazzawi; Jack E. Lemons; Perng-Ru Liu; Milton E. Essig; Gregg M. Janowski

STATEMENT OF PROBLEM When feldspathic porcelain (FP) laminate veneers are used to mask tooth discoloration that extends into the dentin, significant tooth reduction is needed to provide space for the opaque layer and optimize the bonding of the restoration. PURPOSE The purpose of this study was to investigate the color effect of trial insertion paste (TP), composite resin abutment (CRA), and veneer regions on the optical properties of feldspathic porcelain (FP), yttria-stabilized zirconia (Y-TZP), and IPS e.max CAD HT (IEC) veneers. MATERIAL AND METHODS A melamine tooth was prepared for a laminate veneer on a model, and a definitive cast was made. The definitive die was scanned by using the TurboDent System (TDS), then 30 CRA were machined and 10 veneers were fabricated for each ceramic material (FP, Y-TZP, IEC). The optical properties of different veneer materials, CRA (A(1), A(2), A(3)) and TP (bleach XL, opaque white, transparent, and yellow) were evaluated in the cervical, body, and incisal regions with a spectrophotometer. Results were analyzed by using 1-way ANOVA (.05). RESULTS The color difference for all the veneers was affected by TP and CRA colors in different regions. The mean values for the Y-TZP veneer color coordinates (L*: 74 ±0.34, a*: 0.09 ±0.20, and b*: 17.43 ±0.44) were significantly different (P<.001) from those of IEC veneers (L*: 70.15 ±0.23, a*: -0.69 ±0.073, and b*:11.48 ±0.30) and FP veneers (L*: 70.00 ±0.86, a*: - 0.28 ±0.203, and b*: 13.86 ±1.08). There was no difference between IEC for L* and FP. Significant difference was detected (P<.001) in color coordinates among the 3 veneer materials for a* and b*. CONCLUSIONS The TP color affected the color difference for all veneer materials except the Y-TZP, while there was no effect on the CRA color. The magnitude of color coordinates changed as a function of TP color and veneer material.


Journal of Dentistry | 2012

Fracture resistance and marginal discrepancy of porcelain laminate veneers influenced by preparation design and restorative material in vitro.

Tai-Min Lin; Perng-Ru Liu; Lance C. Ramp; Milton E. Essig; Daniel A. Givan; Yu-Hwa Pan

OBJECTIVES The purpose of this investigation is to evaluate marginal discrepancy and fracture resistance of two veneering materials using two preparation designs. METHODS Two veneer preparation designs (full and traditional) were restored with leucite-reinforced ceramic (ProCAD, Ivoclar Vivadent, Amherst, NY) milled by CAD/CAM (Cerec 3D milling system, Serona Dental Systems), and conventional sintered feldspathic porcelain (Noritake Super Porcelain EX3, Noritake Dental Supply Co). Forty-eight specimens were analysed with a sample size of n=12 per group. The thickness of each veneer was measured on four specific surfaces. Marginal discrepancy was evaluated with a replica technique and cross-sectional view using a digital microscope. The fracture resistance of veneers cemented on standardised composite resin dies was evaluated using a universal testing machine. Results were analysed with ANOVA, Tukey-Kramer post hoc testing, and linear regression. RESULTS The results of this investigation revealed no correlation between the thickness and marginal discrepancy of the veneers. The full preparation design with ProCAD and the traditional preparation design with feldspathic porcelain manifested smaller gap. Fracture resistance was decreased for the full preparation design with feldspathic porcelain. CONCLUSIONS In terms of marginal discrepancy and fracture resistance, the most favourable combination was a traditional veneer preparation design with conventional sintered feldspathic porcelain. For the full veneer preparation, a stronger ceramic material such as ProCAD is suggested.


Journal of Prosthetic Dentistry | 2012

The failure load of CAD/CAM generated zirconia and glass-ceramic laminate veneers with different preparation designs.

Tariq F. Alghazzawi; Jack E. Lemons; Perng-Ru Liu; Milton E. Essig; Gregg M. Janowski

STATEMENT OF PROBLEM Fracture of feldspathic porcelain laminate veneers represents a significant mode of clinical failure. Therefore, ceramic materials that withstand a higher load to fracture, especially for patients with parafunctional habits, are needed. PURPOSE The purpose of this study was to examine the correlation of material (zirconia, TZP, glass-ceramic, IEC, and feldspathic porcelain, FP) design (incisal overlapped preparation, IOP, and three-quarter preparation, TQP), and fracture mode to failure load for veneers supported by composite resin abutments. MATERIAL AND METHODS A typodont tooth prepared with 2 designs (IOP, TQP) and the corresponding 2 definitive dies were used to fabricate the composite resin abutments (30 for IOP and 30 for TQP). Ten veneer specimens for each system (Y-TZP, IEC, and FP), were fabricated for each design. The veneers were cemented, invested, and tested in compression until failure by using a universal testing machine. Significant differences were evaluated by 2-factor ANOVA (α=.05). RESULTS No statistical mean load difference was noted between the preparation designs for Y-TZP (IOP: 244 ±81 and TQP: 224 ±58 N), IEC (IOP: 306 ±101 and TQP: 263 ±77 N), and FP veneers (IOP: 161 ±93 and TQP: 246 ±45 N). No statistical difference in the mean load was found among the 3 veneer materials for each preparation design except between IEC (306 ±101 N) and FP (161 ±93 N) veneers for TQP. CONCLUSIONS Preparation design did not influence the failure load of the veneer materials. Zirconia veneers were the least likely to fracture but the most likely to completely debond; feldspathic porcelain veneers exhibited the opposite characteristics.


Journal of Oral Rehabilitation | 2013

An analysis of the implant-supported overdenture in the edentulous mandible

K.-W. Chen; Tai-Min Lin; Perng-Ru Liu; Lance C. Ramp; H.-J. Lin; C.-T. Wu; Y.-H. Pan

This investigation examined the cumulative survival rate of the implant-supported overdenture using two types of attachments in patients treated at Show Chwan Memorial Hospital Implant Center from 1992 to 2006. Fifty-one patients (30 men and 21 women) were treated with mandibular implant-supported overdentures. Attachment systems used were the Hader bar with bilateral, cast ERA attachments (Group A, 31 patients with 15 men and 16 women, 134 implants) and the Hader bar with bilateral, distal extension cantilevers (Group B, 20 patients with 15 men and 5 women, 85 implants). Two hundred and four implants remained at the end of the follow-up period. Among failed implants, 10 implants were in Group A (failure rate: 10/134 = 7·5%), whereas five implants were in Group B (failure rate: 5/85 = 5·9%). Sixty-six point seven per cent (10/15) of failed implants were placed in the distal anterior mandible, and 33·3% (5/15) were placed in the middle anterior mandible. Survival was also examined with respect to condition of the opposing arch. Patients wearing a maxillary removable partial denture had the highest implant failure rate (5/51 = 9·8%), whereas the failure rate of the maxillary complete denture group was only 5·7%. The most frequent need for maintenance was wear over patrix component of ERA or Hader clip (n = 56). Eight patients experienced connector fracture between ERA and Hader bar, and one experienced distal extension cantilever fracture. The implant-supported overdenture can be an effective and reliable alternative to the conventional complete mandibular denture. Fewer prosthetic complications were seen in overdentures retained with distal extension cantilever attachments.


Journal of Prosthetic Dentistry | 2014

Influence of surface treatment of yttrium-stabilized tetragonal zirconium oxides and cement type on crown retention after artificial aging

Mehdi Karimipour-Saryazdi; Ramtin Sadid-Zadeh; Daniel A. Givan; John O. Burgess; Lance C. Ramp; Perng-Ru Liu

STATEMENT OF PROBLEM Information about the influence of zirconia crown surface treatment and cement type on the retention of zirconia crowns is limited. It is unclear whether zirconia crowns require surface treatment to enhance their retention. PURPOSE The purpose of this in vitro study was to evaluate the effect of surface treatment on the retention of zirconia crowns cemented with 3 different adhesive resin cements after artificial aging. MATERIAL AND METHODS Ninety extracted human molars were prepared for ceramic crowns (approximately 20-degree taper, approximately 4-mm axial length) and were divided into 3 groups (n=30). Computer-aided design and computer-aided manufacturing zirconia copings were fabricated. Three surface treatments were applied to the intaglio surface of the copings. The control group received no treatment, the second group was airborne-particle abraded with 50 μm Al2O3, and the third group was treated with 30 μm silica-modified Al2O3, The copings were luted with a self-etch (RelyX Unicem 2), a total-etch (Duo-Link), or a self-etch primer (Panavia F 2.0) adhesive cement. They were stored for 24 hours at 37°C before being artificially aged with 5000 (5°C-55°C) thermal cycles and 100,000 cycles of 70 N dynamic loading. Retention was measured on a universal testing machine under tension, with a crosshead speed of 0.5 mm/min. Statistical analysis was performed with 1-way and 2-way ANOVA. RESULTS Mean retention values ranged from 0.72 to 3.7 MPa. Surface treatment increased crown retention, but the difference was not statistically significant (P>.05), except for the Duo-Link cement group (P<.05). Analysis of the adhesives revealed that the Duo-Link cement resulted in significantly lower crown retention (P<.05) than the other 2 cements. CONCLUSION For zirconia crowns, retention seems to be dependent on cement type rather than surface treatment.


Journal of the American Dental Association | 2015

Effect of imaging powder and CAD/CAM stone types on the marginal gap of zirconia crowns.

Tariq F. Alghazzawi; Khalid H. Al-Samadani; Jack E. Lemons; Perng-Ru Liu; Milton E. Essig; Alfred A. Bartolucci; Gregg M. Janowski

OBJECTIVE To compare the marginal gap using different types of die stones and titanium dies with and without powders for imaging. METHODS A melamine tooth was prepared and scanned using a laboratory 3-shape scanner to mill a polyurethane die, which was duplicated into different stones (Jade, Lean, CEREC) and titanium. Each die was sprayed with imaging powders (NP, IPS, Optispray, Vita) to form 15 groups. Ten of each combination of stone/titanium and imaging powders were used to mill crowns. A light-bodied impression material was injected into the intaglio surface of each crown and placed on the corresponding die. Each crown was removed, and the monophase material was injected to form a monophase die, which was cut into 8 sections. Digital images were captured using a stereomicroscope to measure marginal gap. Scanning electron microscopy was used to determine the particle size and shape of imaging powders and stones. RESULTS Marginal gaps ranged from mean (standard deviation) 49.32 to 1.20 micrometers (3.97-42.41 μm). There was no statistical difference (P > .05) in the marginal gap by any combination of stone/titanium and imaging powders. All of the imaging powders had a similar size and rounded shape, whereas the surface of the stones showed different structures. CONCLUSIONS When a laboratory 3-shape scanner is used, all imaging powders performed the same for scanning titanium abutments. However, there was no added value related to the use of imaging powder on die stone. It is recommended that the selection of stone for a master cast be based on the hysical properties. PRACTICAL IMPLICATIONS When a laboratory 3-shape scanner is used, the imaging powder is not required for scanning die stone. Whenever scanning titanium implant abutments, select the least expensive imaging powder.


Journal of Esthetic and Restorative Dentistry | 2016

Restoring Congenitally Missing Maxillary Lateral Incisors Using Zirconia‐Based Resin Bonded Prostheses

Antigoni Stylianou; Perng-Ru Liu; Sandra J. O'Neal; Milton E. Essig

OBJECTIVE This clinical report describes an alternative treatment modality for the replacement of congenitally missing maxillary lateral incisors in a 17-year-old patient. CLINICAL CONSIDERATIONS Zirconia-based resin-bonded fixed partial dentures (RBFPDs) were selected as a viable and conservative treatment option in a young individual with highly aesthetic expectations. Fabrication of all-ceramic RBFPDs followed specific preparation design and features to accommodate two retainers. The zirconia frameworks with bilateral wings were digitally designed and then milled by a computer-aided design and computer-aided manufacturing (CAD/CAM)-controlled milling machine. Zirconia surface was treated with a two-step chairside tribochemical silica-coating/silane coupling surface treatment protocol, and adhesive resin luting cement was used to achieve micromechanical and chemical bonding. Completion of the treatment resulted in a functional and aesthetic successful outcome and a 17-month follow-up presented uneventful. CONCLUSION Contemporary adhesive techniques involving resin-bonded zirconia-based prostheses can be utilized successfully and predictably in young patients with single missing teeth when implant therapy is currently not a treatment of choice and a less invasive approach is desired. CLINICAL SIGNIFICANCE The zirconia-based resin-bonded prosthesis constitutes a viable and conservative treatment modality for the replacement of missing teeth either congenitally or from another etiology in young patients in which implant therapy and a fixed partial denture are currently contraindicated.


Journal of Prosthetic Dentistry | 2017

Light-transmitting fiber optic posts: An in vitro evaluation

Antigoni Stylianou; John O. Burgess; Perng-Ru Liu; Daniel A. Givan; Nathaniel C. Lawson

Statement of problem. The clinical challenge of adhering cement to intracanal dentin is transmitting light to the most apical parts of root canals to allow more efficient polymerization of the cement. Purpose. The purpose of this in vitro study was to compare the cement‐polymerizing ability, microstructure, and radiopacity of a new fiber optic post (iLumi fiber optic Post) with a clinically successful fiber post (DT Light Post). Material and methods. Polymerizing ability was compared using a modified depth‐of‐polymerization protocol. A split aluminum mold with a 12‐mm cylindrical hole (diameter=4.7 mm) was filled with light‐polymerized resin cement (Variolink Esthetic LC). Each fiber post (n=12) was positioned and light‐polymerized on the coronal end for 60 seconds with a light‐emitting diode polymerization light. Unpolymerized resin was dissolved with an organic solvent, and the weight and length of the polymerized resin cement were measured. Scanning electron microscopy was used to examine vertical and horizontal cross‐sections. The radiopacity values of both the posts and 5 additional reference posts were evaluated using an aluminum step wedge. Results. The weight and length of the polymerized resin cement were significantly greater (P<.05) with the fiber optic post, which scanning electron microscopy showed to have a higher density of parallel fibers. The iLumi post demonstrated greater radiopacity among the tested fiber posts and a titanium alloy post. Conclusions. The iLumi fiber optic posts have a unique structural fiber composition and excellent radiopacity and light‐transmitting ability that produce more complete polymerization of the resin cement than the DT Light posts.


Journal of Oral Implantology | 2015

Effect of Luting Agents on Retention of Dental Implant-Supported Prostheses.

Yu-Hwa Pan; Tai-Min Lin; Perng-Ru Liu; Lance C. Ramp

To evaluate the retentive strength of 7 different luting agents in cement-retained implant abutment/analog assemblies. Fifty-six externally hexed dental implant abutment/analog assemblies and cast superstructures were divided randomly into 7 groups for cementation with each of the 7 luting agents. Five definitive cements tested were zinc phosphate cement, All-Bond 2, Maxcem, RelyX Luting cement, HY-Bond, and two provisional cements, ImProv and Premier. Cast superstructures were cemented onto the implant abutments and exposed to 1000 thermal cycles (0°C-55°C) and 100 000 cycles on a chewing simulator (75 N load). A universal testing machine was used to measure cement failure load of the assembled specimens. Cement failure load was evaluated with 1-way ANOVA and Duncans multiple range analysis. Significant differences in cement failure loads were measured (P < .0001). Post hoc testing with Duncans multiple range indicated 4 separate groupings. Maxcem and All-Bond 2 were comparable, having the greatest load failure. RelyX and zinc phosphate cement were analogous, and higher than HY-Bond. Improv and Premier constituted a pair, which demonstrated the lowest retentive values. Within the limitations of this in vitro study, Maxcem and All-Bond 2 are good candidates for cement-retained implant prostheses while concerning retention.

Collaboration


Dive into the Perng-Ru Liu's collaboration.

Top Co-Authors

Avatar

Lance C. Ramp

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Milton E. Essig

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Jack E. Lemons

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Michael S. Reddy

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Daniel A. Givan

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Gregg M. Janowski

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nico C. Geurs

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge