Peter B Cotton
Maine Medical Center
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Peter B Cotton.
Gastrointestinal Endoscopy | 2009
Burr J. Loew; Douglas A. Howell; Michael K. Sanders; David J. Desilets; Paul P. Kortan; Gary R. May; Raj J. Shah; Yang K Chen; Willis G. Parsons; Robert H Hawes; Peter B Cotton; Adam Slivka; Jawad Ahmad; Glen A. Lehman; Stuart Sherman; Horst Neuhaus; Brigitte Schumacher
BACKGROUNDnThe Wallstent has remained the industry standard for biliary self-expanding metal stents (SEMSs). Recently, stents of differing designs, compositions, and diameters have been developed.nnnOBJECTIVEnTo compare the new nitinol 6-mm and 10-mm Zilver stents with the 10-mm stainless steel Wallstent and determine the mechanism of obstruction.nnnDESIGNnRandomized, prospective, controlled study.nnnSETTINGnNine centers experienced in SEMS placement during ERCP.nnnPATIENTSnA total of 241 patients presenting between September 2003 and December 2005 with unresectable malignant biliary strictures at least 2 cm distal to the bifurcation.nnnMAIN OUTCOME MEASUREMENTnStent occlusions requiring reintervention and death.nnnRESULTSnAt interim analysis, a significant increase in occlusions was noted in the 6-mm Zilver group at the P = .04 level, resulting in arm closure but continued follow-up. Final study arms were 64, 88, and 89 patients receiving a 6-mm Zilver, 10-mm Zilver, and 10-mm Wallstent, respectively. Stent occlusions occurred in 25 (39.1%) of the patients in the 6-mm Zilver arm, 21 (23.9%) of the patients in the 10-mm Zilver arm, and 19 (21.4%) of the patients in the 10-mm Wallstent arm (P = .02). The mean number of days of stent patency were 142.9, 185.8, and 186.7, respectively (P = .057). No differences were noted in secondary endpoints, and the study was ended at the 95% censored study endpoints. Biopsy specimens of ingrowth occlusive tissue revealed that 56% were caused by benign epithelial hyperplasia.nnnCONCLUSIONSnSEMS occlusions were much more frequent with a 6-mm diameter SEMS and equivalent in the two 10-mm arms despite major differences in stent design, material, and expansion, suggesting that diameter is the critical feature. Malignant tumor ingrowth produced only a minority of the documented occlusions.
Endoscopy | 2005
B. Hu; S. C. S. Chung; Lawrence C.L. Sun; K. Kawashima; Tetsuya Yamamoto; Peter B Cotton; C. J. Gostout; Robert H. Hawes; Anthony N. Kalloo; S. V. Kantsevoy; Pankaj J. Pasricha
Endoscopy | 2005
B. Hu; S. C. S. Chung; Lawrence C.L. Sun; James Y. Lau; K. Kawashima; Tetsuya Yamamoto; Peter B Cotton; C. J. Gostout; Robert H. Hawes; Anthony N. Kalloo; S. V. Kantsevoy; Pankaj J. Pasricha
Endoscopy | 2007
Lawrence C; Peter B Cotton; Joseph Romagnuolo; Payne Km; Rawls E; Robert H. Hawes
Endoscopy | 2005
B. Hu; Lawrence C.L. Sun; Manoj K. Karmakar; Peter B Cotton; C. J. Gostout; Robert H. Hawes; Anthony N. Kalloo; S. V. Kantsevoy; Pankaj J. Pasricha; S. C. S. Chung
/data/revues/00165107/v63i5/S001651070600842X/ | 2011
Randhir Sud; Rajesh Puri; Sydney Chung; Peter B Cotton; Gostout J. Christopher; Robert H Hawes; Anthony N. Kalloo; S. V. Kantsevoy; Pankaj J. Pasricha
Archive | 2016
Grace H. Elta; Peter B Cotton; C. Ross Carter; Enrico Corazziari; Pankaj J. Pasricha
Archive | 2016
Grace H. Elta; Peter B Cotton; Ross Carter; Enrico Corazziari; Pankaj J. Pasricha
/data/revues/00165107/v63i5/S0016510706014271/ | 2011
Matthew Carnes; Peter B Cotton; Robert H Hawes; Christopher Lawrence; Mark Payne; Joseph Romagnuolo
/data/revues/00165107/v61i5/S0016510705011429/ | 2011
Young Deok Cho; Sandra Faias; Brenda J. Hoffman; Kenneth M. Payne; Christopher Lawrence; Joseph Romagnuolo; Peter B Cotton; Robert H Hawes