Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Peter Denes is active.

Publication


Featured researches published by Peter Denes.


Philosophical Transactions of the Royal Society A | 2009

Background, status and future of the Transmission Electron Aberration-corrected Microscope project

U. Dahmen; Rolf Erni; Velimir Radmilovic; Christian Ksielowski; Marta-Dacil Rossell; Peter Denes

The strong interaction of electrons with small volumes of matter make them an ideal probe for nanomaterials, but our ability to fully use this signal in electron microscopes remains limited by lens aberrations. To bring this unique advantage to bear on materials research requires a sample space for electron scattering experiments in a tunable electron-optical environment. This is the vision for the Transmission Electron Aberration-corrected Microscope (TEAM) project, which was initiated as a collaborative effort to re-design the electron microscope around aberration-correcting optics. The resulting improvements in spatial, spectral and temporal resolution, the increased space around the sample and the possibility of exotic electron-optical settings will enable new types of experiments. This contribution will give an overview of the TEAM project and its current status, illustrate the performance of the TEAM 0.5 instrument, with highlights from early applications of the machine, and outline future scientific opportunities for aberration-corrected microscopy.


Review of Scientific Instruments | 2009

A fast, direct x-ray detection charge-coupled device

Peter Denes; Dionisio Doering; Howard A. Padmore; Jean-Pierre Walder; John Weizeorick

A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 microm thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output ports. A set of companion 16-channel custom readout integrated circuits, capable of 15 bits of dynamic range, is used to read out the CCD. A gate array-controlled back end data acquisition system frames and transfers images, as well as provides the CCD clocks.


Physical Review Letters | 2012

Femtosecond Dynamics of the Collinear-to-Spiral Antiferromagnetic Phase Transition in CuO

S. L. Johnson; R. A. De Souza; U. Staub; P. Beaud; E. Möhr-Vorobeva; G. Ingold; A. Caviezel; V. Scagnoli; W. F. Schlotter; J. J. Turner; O. Krupin; W. S. Lee; Yi-De Chuang; L. Patthey; R. G. Moore; D. H. Lu; M. Yi; Patrick S. Kirchmann; M. Trigo; Peter Denes; Dionisio Doering; Z. Hussain; Zhi-Xun Shen; D. Prabhakaran; A. T. Boothroyd

We report on the ultrafast dynamics of magnetic order in a single crystal of CuO at a temperature of 207 K in response to strong optical excitation using femtosecond resonant x-ray diffraction. In the experiment, a femtosecond laser pulse induces a sudden, nonequilibrium increase in magnetic disorder. After a short delay ranging from 400 fs to 2 ps, we observe changes in the relative intensity of the magnetic ordering diffraction peaks that indicate a shift from a collinear commensurate phase to a spiral incommensurate phase. These results indicate that the ultimate speed for this antiferromagnetic reorientation transition in CuO is limited by the long-wavelength magnetic excitation connecting the two phases.


Nature Communications | 2012

Phase fluctuations and the absence of topological defects in a photo-excited charge-ordered nickelate

W. S. Lee; Yi-De Chuang; R. G. Moore; Yiwen Zhu; L. Patthey; M. Trigo; D. H. Lu; Patrick S. Kirchmann; O. Krupin; M. Yi; M. C. Langner; Nils Huse; Y. Chen; Shuyun Zhou; G. Coslovich; Bernhard Huber; David A. Reis; Robert A. Kaindl; Robert W. Schoenlein; D. Doering; Peter Denes; W. F. Schlotter; J. J. Turner; S. L. Johnson; Michael Först; T. Sasagawa; Y. F. Kung; A. P. Sorini; A. F. Kemper; Brian Moritz

The dynamics of an order parameters amplitude and phase determines the collective behaviour of novel states emerging in complex materials. Time- and momentum-resolved pump-probe spectroscopy, by virtue of measuring material properties at atomic and electronic time scales out of equilibrium, can decouple entangled degrees of freedom by visualizing their corresponding dynamics in the time domain. Here we combine time-resolved femotosecond optical and resonant X-ray diffraction measurements on charge ordered La(1.75)Sr(0.25)NiO(4) to reveal unforeseen photoinduced phase fluctuations of the charge order parameter. Such fluctuations preserve long-range order without creating topological defects, distinct from thermal phase fluctuations near the critical temperature in equilibrium. Importantly, relaxation of the phase fluctuations is found to be an order of magnitude slower than that of the order parameters amplitude fluctuations, and thus limits charge order recovery. This new aspect of phase fluctuations provides a more holistic view of the phases importance in ordering phenomena of quantum matter.


Review of Scientific Instruments | 2011

Development of a compact fast CCD camera and resonant soft x-ray scattering endstation for time-resolved pump-probe experiments

Dionisio Doering; Yi-De Chuang; Nord Andresen; Ken P. Chow; Devis Contarato; Curtis L. Cummings; Edward E. Domning; John Joseph; J. S. Pepper; Brian V. Smith; G.J. Zizka; C. Ford; Wei-Sheng Lee; M. Weaver; L. Patthey; John Weizeorick; Z. Hussain; Peter Denes

The designs of a compact, fast CCD (cFCCD) camera, together with a resonant soft x-ray scattering endstation, are presented. The cFCCD camera consists of a highly parallel, custom, thick, high-resistivity CCD, readout by a custom 16-channel application specific integrated circuit to reach the maximum readout rate of 200 frames per second. The camera is mounted on a virtual-axis flip stage inside the RSXS chamber. When this flip stage is coupled to a differentially pumped rotary seal, the detector assembly can rotate about 100°/360° in the vertical/horizontal scattering planes. With a six-degrees-of-freedom cryogenic sample goniometer, this endstation has the capability to detect the superlattice reflections from the electronic orderings showing up in the lower hemisphere. The complete system has been tested at the Advanced Light Source, Lawrence Berkeley National Laboratory, and has been used in multiple experiments at the Linac Coherent Light Source, SLAC National Accelerator Laboratory.


electronic imaging | 2004

First use of a high-sensitivity active pixel sensor array as a detector for electron microscopy

Nguyen-Huu Xuong; Anna-Clare Milazzo; Philippe C. Leblanc; Fred Duttweiler; James C. Bouwer; Steve Peltier; Mark H. Ellisman; Peter Denes; F. Bieser; H. S. Matis; Howard Wieman; Stuart Kleinfelder

There is an urgent need to replace film and CCD cameras as recording instruments for transmission electron microscopy (TEM). Film is too cumbersome to process and CCD cameras have low resolution, marginal to poor signal-to-noise ratio for single electron detection and high spatial distortion. To find a replacement device, we have tested a high sensitivity active pixel sensor (APS) array currently being developed for nuclear physics. The tests were done at 120 keV in a JEOL 1200 electron microscope. At this energy, each electron produced on average a signal-tonoise ratio about 20/1. The spatial resolution was also excellent with the full width at half maximum (FWHM) about 20 microns. Since it is very radiation tolerant and has almost no spatial distortion, the above tests showed that a high sensitivity CMOS APS array holds great promise as a direct detection device for electron microscopy.


To appear in the proceedings of | 2005

The SuperCDMS Experiment

R. W. Schnee; D. S. Akerib; M. J. Attisha; C. N. Bailey; L. Baudis; D. A. Bauer; P. L. Brink; Pavel Brusov; R. Bunker; B. Cabrera; David O. Caldwell; C.L. Chang; J. Cooley; M. B. Crisler; P. Cushman; Peter Denes; M. R. Dragowsky; L. Duong; J. Filippini; R.J. Gaitskell; S. R. Golwala; D. R. Grant; R. Hennings-Yeomans; D. Holmgren; M. E. Huber; K. D. Irwin; A. Lu; R. Mahapatra; P. Meunier; N. Mirabolfathi

Modest improvements in the level and/or discrimination of backgrounds are needed to keep backgrounds negligible during the three phases of SuperCDMS. By developing production designs that require only modest testing, detector production rates may be improved sufficiently to allow an exposure of 500 ton d within a reasonable time and budget. Overall, the improvement estimates described above are conservative. Previous development efforts have shown that some areas prove easier and provide larger factors while others prove more difficult. The conservative estimates together with the broad approach reduce the risk and give us confidence that we will succeed, providing the surest way to probe to WIMP-nucleon cross sections of 10{sup -46} cm{sup 2}.


IEEE Transactions on Nuclear Science | 2002

Analog front-end cell designed in a commercial 0.25 /spl mu/m process for the ATLAS pixel detector at LHC

L. Blanquart; J. Richardson; Peter Denes; K. Einsweiler; E. Mandelli; G. Meddeler; P. Fischer; M. Ackers; G. Comes; I. Peric

A new analog pixel front-end cell has been developed for the ATLAS detector at the future Large Hadron Collider (LHC) at the European Laboratory for Particle Physics (CERN). This analog cell has been submitted in two commercial 0.25 /spl mu/m CMOS processes (in an analog test chip format), using special layout techniques for radiation hardness purposes. It is composed of two cascaded amplifiers followed by a fast discriminator featuring a detection threshold within the range of 1000 to 10000 electrons. The first preamplifier has the principal role of providing a large bandwidth, low input impedance, and fast rise time in order to enhance the time-walk and crosstalk performance, whereas the second fully differential amplifier is aimed at delivering a sufficiently high-voltage gain for optimum comparison. A new do feedback concept renders the cell tolerant of sensor leakage current up to 300 nA and provides monitoring of this current. Two 5-bit digital-to-analog converters tolerant to single-event upset have been implemented for threshold and recovery-time pixel-to-pixel matching purposes. Special attention has been paid to the power-supply rejection ratio to minimize sensitivity to pickup. The complete cell dissipates 30 /spl mu/W, occupies an area of 50/spl times/90 /spl mu/m/sup 2/ and is operated with a single 1.6-V power supply. Measurements of two test chips are presented.


Review of Scientific Instruments | 2016

Femtosecond X-ray magnetic circular dichroism absorption spectroscopy at an X-ray free electron laser

Daniel Higley; Konstantin Hirsch; Georgi L. Dakovski; Emmanuelle Jal; Edwin Yuan; TianMin Liu; Alberto Lutman; James P. MacArthur; Elke Arenholz; Zhao Chen; G. Coslovich; Peter Denes; Patrick Granitzka; P. Hart; Matthias C. Hoffmann; John Joseph; Loic Le Guyader; Ankush Mitra; Stefan Moeller; Hendrik Ohldag; Matthew D. Seaberg; Padraic Shafer; J. Stöhr; A. Tsukamoto; H.-D. Nuhn; A. H. Reid; Hermann A. Dürr; W. F. Schlotter

X-ray magnetic circular dichroism spectroscopy using an X-ray free electron laser is demonstrated with spectra over the Fe L(3,2)-edges. The high brightness of the X-ray free electron laser combined with high accuracy detection of incident and transmitted X-rays enables ultrafast X-ray magnetic circular dichroism studies of unprecedented sensitivity. This new capability is applied to a study of all-optical magnetic switching dynamics of Fe and Gd magnetic sublattices in a GdFeCo thin film above its magnetization compensation temperature.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2007

A monolithic pixel sensor in 0.15μm fully depleted SOI technology

M. Battaglia; D. Bisello; Devis Contarato; Peter Denes; Piero Giubilato; Lindsay Glesener; C. Vu

Abstract This letter presents the design of a monolithic pixel sensor with 10 × 10 μ m 2 pixels in OKI 0.15 μ m fully depleted SOI technology and first results of its characterisation. The response of the chip to charged particles has been studied on the 1.35 GeV e - beam at the LBNL ALS.

Collaboration


Dive into the Peter Denes's collaboration.

Top Co-Authors

Avatar

Devis Contarato

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Dionisio Doering

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

M. Battaglia

University of California

View shared research outputs
Top Co-Authors

Avatar

John Joseph

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yi-De Chuang

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

W. F. Schlotter

SLAC National Accelerator Laboratory

View shared research outputs
Top Co-Authors

Avatar

Z. Hussain

Lawrence Berkeley National Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge