Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Peter Jarzem is active.

Publication


Featured researches published by Peter Jarzem.


Global Spine Journal | 2015

The Relationship between Preoperative Expectations and the Short-Term Postoperative Satisfaction and Functional Outcome in Lumbar Spine Surgery: A Systematic Review

Daniel J. Ellis; Jacob E. Mathews; Isaac L. Moss; Jean Ouellet; Peter Jarzem; Michael H. Weber

Study Design Systematic review. Objective To examine the relationship between the patients preoperative expectations and short-term postoperative satisfaction and functional outcome in lumbar spine surgery. Methods The Medline, Embase, and Cochrane databases were queried using a predefined search algorithm to identify all lumbar spine studies analyzing the influence of preoperative expectations on postoperative satisfaction and functional outcome. Two independent reviewers and a third independent mediator reviewed the literature and performed study screening, selection, methodological assessment, and data extraction using an objective protocol. Results Of 444 studies identified, 13 met the inclusion criteria. Methodological quality scores ranged from 59 to 100% with the greatest variability in defining patient characteristics and the methods of assessing patient expectations. Patient expectations were assessed in 22 areas, most frequently back and leg pain expectations and general expectations. Functional outcome was assessed by 13 tools; the most common were the visual analog scale, Oswestry Disability Index (ODI), and Short Form Health Survey (SF-36). Positive expectations for symptomatology, activity, general health, and recovery correlated with satisfaction. General expectations correlated with higher SF-36 Physical Subcomponent scores, better global function, and lower ODI outcome. Conclusions on the influence of the expectations for pain were limited due to the study heterogeneity, but the evidence suggests a positive correlation between the expectation and outcome for back and leg pain. Conclusions Positive expectations correlated significantly with short-term postoperative satisfaction and functional outcome, including higher SF-36 scores, earlier return to work, and decreased ODI scores. Future expectation-based investigations will benefit from implementation of the standardized methods of expectation, satisfaction, and outcome analysis discussed herein.


Global Spine Journal | 2016

Incidence, Predictors, and Postoperative Complications of Blood Transfusion in Thoracic and Lumbar Fusion Surgery: An Analysis of 13,695 Patients from the American College of Surgeons National Surgical Quality Improvement Program Database

Ahmed Aoude; Anas Nooh; Maryse Fortin; Sultan Aldebeyan; Peter Jarzem; Jean Ouellet; Michael H. Weber

Study Design Retrospective cohort study. Objective To identify predictive factors for blood transfusion and associated complications in lumbar and thoracic fusion surgeries. Methods The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database was used to identify patients who underwent lumbar or thoracic fusion from 2010 to 2013. Multivariate analysis was used to determine predictive factors and postoperative complications associated with transfusion. Results Out of 13,695 patients, 13,170 had lumbar fusion and 525 had thoracic fusion. The prevalence of transfusion was 31.8% for thoracic and 17.0% for lumbar fusion. The multivariate analysis showed that age between 50 and 60, age between 61 and 70, ageu2009>u200970, dyspnea, American Society of Anesthesiologists class 3, bleeding disease, multilevel surgery, extended surgical time, return to operation room, and higher preoperative blood urea nitrogen (BUN) were predictors of blood transfusion for lumbar fusion. Multilevel surgery, preoperative BUN, and extended surgical time were predictors of transfusion for thoracic fusion. Patients receiving transfusions who underwent lumbar fusion were more likely to develop wound infection, venous thromboembolism, pulmonary embolism, and myocardial infarction and had longer hospital stay. Patients receiving transfusions who underwent thoracic fusion were more likely to have extended hospital stay. Conclusion This study characterizes incidence, predictors, and postoperative complications associated with blood transfusion in thoracic and lumbar fusion. Pre- and postoperative planning for patients deemed to be at high risk of requiring blood transfusion might reduce postoperative complications in this population.


Global Spine Journal | 2017

Differences between Manufacturers of Computed Tomography-Based Computer-Assisted Surgery Systems Do Exist: A Systematic Literature Review

Anas Nooh; Joushua Lubov; Ahmed Aoude; Sultan Aldebeyan; Peter Jarzem; Jean Ouellet; Michael H. Weber

Study Design Literature review. Objective Several studies have shown that the accuracy of pedicle screw placement significantly improves with use of computed tomography (CT)-based navigation systems. Yet, there has been no systematic review directly comparing accuracy of pedicle screw placement between different CT-based navigation systems. The objective of this study is to review the results presented in the literature and compare CT-based navigation systems relative only to screw placement accuracy. Methods Data sources included CENTRAL, Medline, PubMed, and Embase databases. Studies included were randomized clinical trials, case series, and case–control trials reporting the accuracy of pedicle screws placement using CT-based navigation. Two independent reviewers extracted the data from the selected studies that met our inclusion criteria. Publications were grouped based on the CT-based navigation system used for pedicle screw placement. Results Of the 997 articles we screened, only 26 met all of our inclusion criteria and were included in the final analysis, which showed a significant statistical difference (pu2009<u20090.0001, 95% confidence interval 0.92 to 1.23) in accuracy of pedicle screw placement between three different CT-based navigation systems. The mean (weighted) accuracy of pedicle screws placement based on the CT-based navigation system was found to be 97.20u2009±u20092.1% in StealthStation (Medtronic, United States) and 96.1u2009±u20093.9% in VectorVision (BrainLab, Germany). Conclusion This review summarizes results presented in the literature and compares screw placement accuracy using different CT-based navigation systems. Although certain factors such as the extent of the procedure and the experience and skills of the surgeon were not accounted for, the differences in accuracy demonstrated should be considered by spine surgeons and should be validated for effects on patients’ outcome.


Case reports in orthopedics | 2015

Pulmonary Artery Cement Embolism after a Vertebroplasty

Anas Nooh; Fahad H. Abduljabbar; Ahmed H. Abduljabbar; Peter Jarzem

Background Context. Vertebroplasty is a minimally invasive procedure most commonly used for the treatment of vertebral compression fractures. Although it is relatively safe, complications have been reported over time. Among those complications, massive cement pulmonary embolism is considered a rare complication. Here we report a case of massive diffuse cement pulmonary embolism following percutaneous vertebroplasty for a vertebral compression fracture. Study Design. Case report. Methods. This is a 70-year-old female who underwent vertebroplasty for T11 and T12 vertebral compression fracture. Results. CT-scan revealed an incidental finding of cement embolism in the pulmonary trunk and both pulmonary arteries. Since the patient was asymptomatic, she was monitored closely and she did not need any intervention. Conclusion. Vertebroplasty is a minimally invasive procedure used for treatment of vertebral compression fracture. Despite the low rate of complications, a pulmonary cement embolism can occur. The consequences of cement embolism range widely from being asymptomatic to embolism that can cause paralysis, radiculopathy, or a fatal pulmonary embolism.


Orthopedic Reviews | 2015

Misdiagnosing absent pedicle of cervical spine in the acute trauma setting

Fahad H. Abduljabbar; Felipe Rossel; Anas Nooh; Peter Jarzem

Congenital absence of cervical spine pedicle can be easily misdiagnosed as facet dislocation on plain radiographs especially in the acute trauma setting. Additional imaging, including computed tomography (CT)-scan with careful interpretation is required in order to not misdiagnose cervical posterior arch malformation with subsequent inappropriate management. A 39-year-old patient presented to the emergency unit of our university hospital after being trampled by a cow over her back and head followed by loss of consciousness, retrograde amnesia and neck pain. Her initial cervical CT-scan showed possible C5-C6 dislocation, then, it became clear that her problem was a misdiagnosed congenital cervical abnormality. Patient was treated symptomatically without consequences. The congenital absence of a cervical pedicle is a very unusual condition that is easily misdiagnosed. Diagnosis can be accurately confirmed with a CT-scan of the cervical spine. Symptomatic conservative treatment will result in resolution of the symptoms.


Global Spine Journal | 2015

Does Balloon Kyphoplasty Deliver More Cement Safely into Osteoporotic Vertebrae with Compression Fractures Compared with Vertebroplasty? A Study in Vertebral Analogues:

Fahad H. Abduljabbar; Abdulaziz N.A. Al-Jurayyan; Saad M. Alqahtani; Zeeshan M. Sardar; Rajeet Singh Saluja; Jean Ouellet; Michael H. Weber; Thomas Steffen; Lorne Beckman; Peter Jarzem

Study Design A biomechanical and radiographic study using vertebral analogues. Objectives Kyphoplasty and vertebroplasty are widely used techniques to alleviate pain in fractures secondary to osteoporosis. However, cement leakage toward vital structures like the spinal cord can be a major source of morbidity and even mortality. We define safe cement injection as the volume of the cement injected into a vertebra before the cement leakage occurs. Our objective is to compare the amount of cement that can be safely injected into an osteoporotic vertebra with simulated compression fracture using either vertebroplasty or balloon kyphoplasty techniques. Methods Forty artificial vertebral analogues made of polyurethane with osteoporotic cancellous matrix representing the L3 vertebrae were used for this study and were divided into four groups of 10 vertebrae each. The four groups tested were: low-viscosity cement injected using vertebroplasty, high-viscosity cement injected using vertebroplasty, low-viscosity cement injected using balloon kyphoplasty, and high-viscosity cement injected using balloon kyphoplasty. The procedures were performed under fluoroscopic guidance. The injection was stopped when the cement started protruding from the created vascular channel in the osteoporotic vertebral fracture model. The main outcome measured was the volume of the cement injected safely into a vertebra before leakage through the posterior vascular channel. Results The highest volume of the cement injected was in the vertebroplasty group using high-viscosity cement, which was almost twice the injected volume in the other three groups. One-way analysis of variance comparing the four groups showed a statistically significant difference (pu2009<u20090.005). Conclusions High-viscosity cement injected using vertebroplasty delivers more cement volume before cement leakage and fills the vertebral body more uniformly when compared with balloon kyphoplasty in osteoporotic vertebrae with compression fractures.


Asian Spine Journal | 2018

Postoperative Assessment of Pedicle Screws and Management of Breaches: A Survey among Canadian Spine Surgeons and a New Scoring System

Ahmed Aoude; Saber Ghadakzadeh; Hamzah Alhamzah; Maryse Fortin; Peter Jarzem; Jean Ouellet; Michael H. Weber

Study Design This study was designed as a survey amongst Canadian spine surgeon to determine a scoring system to standardize pedicle screw placement assessment. Purpose This study aimed to obtain and analyze the opinions of spine surgeons regarding the assessment of pedicle screw accuracy, with the goal of establishing clinical guidelines for interventions for malpositioned pedicle screws. Overview of Literature Accurate placement of pedicle screws is challenging, and misalignment can lead to various complications. To date, there is no recognized gold standard for assessing pedicle screw placement accuracy. The literature is lacking studies attempting to standardize pedicle screw placement accuracy assessment. Methods A survey of the clinical methods and imaging criteria that are used for assessing pedicle screw placement accuracy was designed and sent to orthopedic and neurosurgery spine surgeons from the Canadian Spine Society for their anonymous participation. Results Thirty-five surgeons completed the questionnaire. The most commonly used modalities for assessing pedicle screw position postoperatively were plain X-rays (97%) and computed tomography (CT, 97%). In both symptomatic and asymptomatic patients, the most and least worrisome breaches were medial and anterior breaches, respectively. The majority of surgeons tended not to re-operate on asymptomatic breaches. More than 60% of surgeons would re-operate on patients with new-onset pain and a ≤4-mm medial or inferior breach in both thoracic and lumbar regions. If a patient experienced sensory loss and a breach on CT, in either the thoracic or lumbar levels, 90% and 70% of the surgeons would re-operate for a medial breach and an inferior breach, respectively. Conclusions Postoperative clinical presentation and imaging findings are crucial for interpreting aberrant pedicle screw placement. This study presents a preliminary scoring system for standardizing the classification of pedicle screws.


Asian Spine Journal | 2017

Prevalence and Complications of Postoperative Transfusion for Cervical Fusion Procedures in Spine Surgery: An Analysis of 11,588 Patients from the American College of Surgeons National Surgical Quality Improvement Program Database

Ahmed Aoude; Sultan Aldebeyan; Maryse Fortin; Anas Nooh; Peter Jarzem; Jean Ouellet; Michael H. Weber

Study Design Retrospective cohort study. Purpose The purpose of this study was to assess the rate of blood transfusion after cervical fusion surgery, and its effect on complication rates. Overview of Literature Cervical spine fusions have gained interest in the literature since these procedures are now ever more frequently being performed in an outpatient setting with few complications. Methods The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database was used to identify patients that underwent cervical fusion from 2010 to 2013. Multivariate regression analysis was used to determine postoperative complications associated with transfusion and cervical fusion. Results We identified 11,588 patients who had cervical fusion between 2010 and 2013. The rate of blood transfusion following cervical fusion found to be 1.47%. All transfused patients were found to have increased risk of venous thromboembolism (TBE) (odds ratio [OR], 3.19; 95% confidence interval [95% CI], 1.16–8.77), myocardial infarction (MI) (OR, 9.12; 95% CI, 2.53–32.8), increased length of stay (LOS) (OR, 28.03; 95% CI, 14.28–55.01) and mortality (OR, 4.14; 95% CI, 1.44–11.93). Single level fusion had increased risk of TBE (OR, 3.37; 95% CI, 1.01–11.33), MI (OR, 10.5; 95% CI, 1.88–59.89), and LOS (OR, 14.79; 95% CI, 8.2–26.67). Multilevel fusion had increased risk of TBE (OR, 5.64; 95% CI, 1.15–27.6), surgical site infection (OR, 16.29; 95% CI, 3.34–79.49), MI (OR, 10.84; 95% CI, 2.01–58.55), LOS (OR, 26.56; 95% CI, 11.8–59.78), and mortality (OR, 10.24; 95% CI, 2.45–42.71). Patients who had anterior cervical discectomy and fusion surgery and received a transfusion had an increased risk of TBE (OR, 4.87; 95% CI, 1.04–22.82), surgical site infection (OR, 9.73; 95% CI, 2.14–44.1), MI (OR, 9.88; 95% CI, 1.87–52.2), increased LOS of more than 2 days (OR, 28.34; 95% CI, 13.79–58.21) and increase in mortality (OR, 6.3; 95% CI, 1.76–22.48). While, transfused patients who had posterior fusion surgery had increased risk of MI (OR, 10.45; 95% CI, 1.42–77.12) and increased LOS of more than 6 days (OR, 4.42; 95% CI, 2.68–7.29). Conclusions Our results demonstrate that although cervical fusions can be done as outpatient procedures special precautions and investigations should be done for patients who receive transfusion after cervical fusion. These patients are demonstrated to have higher rate of MI, TBE, wound infection and mortality when compared to those who do not receive transfusion.


Case reports in orthopedics | 2015

Polyarticular Septic Arthritis in an Immunocompetent Adult: A Case Report and Review of the Literature.

Annelise Miller; Fahad H. Abduljabbar; Peter Jarzem

Septic arthritis is a clinical emergency requiring prompt diagnosis and treatment to avoid significant morbidity and mortality. Polyarticular septic arthritis (PASA) accounts for 15% of all infectious arthritides and rarely occurs in immunocompetent adults. Staphylococcus aureus is the most commonly isolated organism, with infection primarily affecting knees, shoulders, elbows, and hips. The morbidity associated with PASA is very high, and mortality in treated cases of PASA may be as high as 50% of cases. We report a case of PASA with associated epidural abscess in a healthy adult male, who presented with complaints of arthralgia and limited range of motion of his left shoulder, wrist, and ankle. He also presented with low back pain and motor weakness associated with an epidural abscess spanning L2-S1, with multilevel vertebral osteomyelitis. Surgical washout of the affected joints as well as decompressive laminectomies was performed, and he received a standard course of intravenous antibiotics. Staphylococcus aureus was isolated from joint aspirations and from blood cultures. The patient had a full neurological and functional recovery postoperatively with no sequelae. To the best of our knowledge this is the only case report of Staphylococcus aureus PASA with concomitant epidural abscess in an immunocompetent adult.


Global Spine Journal | 2013

Failure of a carbon fiber-reinforced polymer implant used for transforaminal lumbar interbody fusion.

Zeeshan Sardar; Peter Jarzem

Lumbar interbody fusion is a common procedure owing to the high prevalence of degenerative spinal disorders. During such procedures, carbon fiber–reinforced polymer (CFRP) cages are frequently utilized to fill the void created between adjacent vertebral bodies, to provide mechanical stability, and to carry graft material. Failure of such implants can lead to significant morbidity. We discuss the possible causes leading to the failure of a CFRP cage in a patient with rheumatoid arthritis. Review of a 49-year-old woman who underwent revision anterior lumbar interbody fusion 2 years after posterior instrumentation and transforaminal lumbar interbody fusion at L4–L5 and L5–S1. The patient developed pseudarthrosis at the two previously fused levels with failure of the posterior instrumentation. Revision surgery reveled failure with fragmentation of the CFRP cage at the L5–S1 level. CFRP implants can break if mechanical instability or nonunion occurs in the spinal segments, thus emphasizing the need for optimizing medical management and meticulous surgical technique in achieving stability.

Collaboration


Dive into the Peter Jarzem's collaboration.

Top Co-Authors

Avatar

Jean Ouellet

McGill University Health Centre

View shared research outputs
Top Co-Authors

Avatar

Michael H. Weber

McGill University Health Centre

View shared research outputs
Top Co-Authors

Avatar

Ahmed Aoude

McGill University Health Centre

View shared research outputs
Top Co-Authors

Avatar

Anas Nooh

King Abdulaziz University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Maryse Fortin

McGill University Health Centre

View shared research outputs
Top Co-Authors

Avatar

Sultan Aldebeyan

McGill University Health Centre

View shared research outputs
Top Co-Authors

Avatar

Anas Nooh

King Abdulaziz University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Daniel J. Ellis

McGill University Health Centre

View shared research outputs
Researchain Logo