Clinical Orthopaedics and Related Research | 1994

Posteromedial tibial polyethylene failure in total knee replacements.

Peter L. Lewis; Cecil H. Rorabeck; Robert B. Bourne; Peter A. Devane

This report details 16 cases of focal posteromedial tibial polyethylene wear and failure after total knee arthroplasty. This wear phenomenon was associated with an external rotatory subluxation of the tibial component relative to the femoral component. Failure occurred in ten Miller Galante 1, three Porous Coated Anatomic, two Kinematic, and one Press-Fit Condylar knee designs at a mean time of 45 months from their implantation. With this type of failure, there did not seem to be a relationship with metal type, fixation, polyethylene manufacturing method, or polyethylene thickness. A relatively flat design of the tibial articular surface was common to all of these components. In certain patients this articular design may allow excessive component translation, which leads to polyethylene deformity, wear, and subluxation. Some methods for preventing this failure mode are reported here.


Clinical Orthopaedics and Related Research | 1995

Screw osteolysis after cementless total knee replacement.

Peter L. Lewis; Cecil H. Rorabeck; Robert B. Bourne

A comparative radiographic review of 217 cementless total knee replacements was done 4 years after surgery to look for radiographic change at the screw-bone interface. There were 102 Miller Galante I knee prostheses, 59 Miller Galante II prostheses, and 56 Anatomic Modular Knee prostheses studied. If the appearance of the screw-bone interface had changed, this was classified according to the width of the Iucency. Two hundred sixty-five of the 851 screws that were studied showed some evidence of change, with 185 (21.7%) of the screws showing a cavitary appearance change. The AMK prosthesis showed the higher incidence of cystic and cavitary changes. Polyethylene debris is thought to be responsible for generation of osteolysis and the radiographic appearance change. Design of the components and particularly the polyethylene attachment mechanism may be responsible for the differences in the frequencies of osteolysis.


Journal of Bone and Joint Surgery, American Volume | 1993

The Miller-Galante knee prosthesis for the treatment of osteoarthrosis. A comparison of the results of partial fixation with cement and fixation without any cement.

Cecil H. Rorabeck; Robert B. Bourne; Peter L. Lewis; L Nott

In a prospective, non-randomized study of 344 patients who had 392 primary total knee replacements with a Miller-Galante I prosthesis for the treatment of osteoarthrosis, the results of partial fixation with cement (insertion of the tibial and patellar components with cement and of the femoral component without cement) were compared with those of fixation without any cement. Of the 392 knees, 183 (163 patients) had fixation without cement (Group I) and 209 (181 patients), with and without cement (Group II). The average duration of follow-up was three years (range, two to five years). Nine patients died during the follow-up period, but no others were lost to follow-up. Analysis of the knee scores, range of motion of the knee, radiographs, and rates of complications revealed no differences between the outcomes in the two groups during the follow-up period. The rate of complications due to problems related to the extensor mechanism was high in both groups: a reoperation was performed in fifteen (8 per cent) of the knees that had had fixation without cement and in nineteen (9 per cent) of those that had had both types of fixation. Thirteen patients had additional operative treatment for recurrent patellar dislocations; twelve patients, for abnormal wear of the polyethylene of the patellar component: two patients, for avulsion of the patellar ligament from the tibia; and two patients, for unexplained pain in the knee. In addition, there were eight patellar fractures (two of which led to a reoperation) and three deep infections (all of which led to a reoperation).


Orthopedic Clinics of North America | 1998

THE PATHOGENESIS OF BONE LOSS FOLLOWING TOTAL KNEE ARTHROPLASTY

Peter L. Lewis; Nigel T. Brewster; Stephen Graves

Bone loss following total knee arthroplasty (TKA) may be focal or diffuse. It may be caused mechanically, either by unloading of the bone leading to disuse osteoporosis, or by overloading of the bone leading to trabecular fractures and bone destruction. Osteolysis, instigated by an inflammatory reaction to particulate wear debris, is an important and common cause of bone loss after TKA. Less common, though sometimes dramatic, causes of bone loss are infection and osteonecrosis.


Journal of Bone and Joint Surgery, American Volume | 2017

Twelve-year Outcomes of an Oxinium Total Knee Replacement Compared with the Same Cobalt-chromium Design: An Analysis of 17,577 Prostheses from the Australian Orthopaedic Association National Joint Replacement Registry.

Christopher J. Vertullo; Peter L. Lewis; Stephen Graves; Lan Kelly; Michelle Lorimer; Peter Myers

Background: Oxidized zirconium (Oxinium) was introduced as an alternative bearing surface to cobalt-chromium (CoCr) in an attempt to reduce polyethylene wear and decrease aseptic mechanical failure of total knee replacements. While noncomparative reports have been described as promising, we were aware of no short or long-term clinical studies showing the superiority of Oxinium on polyethylene as a bearing surface. Using data from a comprehensive national joint replacement registry, we compared the long-term outcomes after cruciate-retaining total knee arthroplasty (TKA) with an Oxinium femoral component and those with the same prosthetic design but with a CoCr femoral component. Methods: The cohorts consisted of 17,577 cemented Genesis-II cruciate-retaining total knee replacements using non-cross-linked polyethylene, which included 11,608 with CoCr femoral components and 5,969 with Oxinium femoral components. The cumulative percent revision and hazard ratio (HR) for revision risk were estimated for the cemented Genesis-II Oxinium and CoCr cruciate-retaining TKAs performed in Australia from September 1, 1999, to December 31, 2013. In addition, the revision diagnoses and the effects of age and patellar resurfacing were examined. Results: No difference in the HR for revision risk was found between the Oxinium and CoCr cohorts for any age category for all causes of revision (HR = 0.92 [95% confidence interval (CI), 0.78 to 1.08]; p = 0.329), loosening or lysis, or aseptic causes, except for loosening or lysis in the group of patients who were ≥75 years old (p = 0.033). In these patients, TKA with Oxinium femoral components had a higher rate of revision. Younger patients preferentially received Oxinium femoral components. The revision risk was not affected by patellar resurfacing or nonresurfacing. At 12 years, the cumulative percent revision was 4.8% (95% CI, 4.2% to 5.4%) for the CoCr Genesis-II prosthesis compared with 7.7% (95% CI, 6.2% to 9.5%) for the Oxinium Genesis-II prosthesis. Conclusions: In this cohort study involving the same prosthetic design, Oxinium femoral components did not reduce revision rates for all causes, loosening or lysis, or when infection as a cause of revision was removed compared with the same CoCr femoral component across all age groups including patients who were <55 years old. The cumulative percent revision was greater for the Oxinium components than for the CoCr components. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Journal of Bone and Joint Surgery, American Volume | 2017

The Effect on Long-term Survivorship of Surgeon Preference for Posterior-stabilized or Minimally Stabilized Total Knee Replacement: An Analysis of 63,416 Prostheses from the Australian Orthopaedic Association National Joint Replacement Registry

Christopher J. Vertullo; Peter L. Lewis; Michelle Lorimer; Stephen Graves

Background: Controversy still exists as to the optimum management of the posterior cruciate ligament (PCL) in total knee arthroplasty. Surgeons can choose to kinematically substitute the PCL with a posterior-stabilized total knee replacement or alternatively to utilize a cruciate-retaining, also known as minimally stabilized, total knee replacement. Proponents of posterior-stabilized total knee replacement propose that the reported lower survivorship in registries when directly compared with minimally stabilized total knee replacement is due to confounders such as selection bias because of the preferential usage of posterior-stabilized total knee replacement in more complex or severe cases. In this study, we aimed to eliminate these possible confounders by performing an instrumental variable analysis based on surgeon preference to choose either posterior-stabilized or minimally stabilized total knee replacement, rather than the actual prosthesis received. Methods: Cumulative percent revision, hazard ratio (HR), and revision diagnosis data were obtained from the Australian Orthopaedic Association National Joint Replacement Registry from September 1, 1999, to December 31, 2014, for 2 cohorts of patients, those treated by high-volume surgeons who preferred minimally stabilized replacements and those treated by high-volume surgeons who preferred posterior-stabilized replacements. All patients had a diagnosis of osteoarthritis and underwent fixed-bearing total knee replacement with patellar resurfacing. Results: At 13 years, the cumulative percent revision was 5.0% (95% confidence interval [CI], 4.0% to 6.2%) for the surgeons who preferred the minimally stabilized replacements compared with 6.0% (95% CI, 4.2% to 8.5%) for the surgeons who preferred the posterior-stabilized replacements. The revision risk for the surgeons who preferred posterior-stabilized replacements was significantly higher for all causes (HR = 1.45 [95% CI, 1.30 to 1.63]; p < 0.001), for loosening or lysis (HR = 1.93 [95% CI, 1.58 to 2.37]; p < 0.001), and for infection (HR = 1.51 [95% CI, 1.25 to 1.82]; p < 0.001). This finding was irrespective of patient age and was evident with cemented fixation and with both cross-linked polyethylene and non-cross-linked polyethylene. However, the higher revision risk was only evident in male patients. Conclusions: There was a 45% higher risk of revision for the patients of surgeons who preferred a posterior-stabilized total knee replacement compared with the patients of surgeons who preferred a minimally stabilized total knee replacement. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Journal of Bone and Joint Surgery, American Volume | 2014

Survivorship of Hip and Knee Implants in Pediatric and Young Adult Populations

Art Sedrakyan; Lucas Romero; Stephen Graves; David Davidson; Richard de Steiger; Peter L. Lewis; Michael J. Solomon; Robyn Vial; Michelle Lorimer

BACKGROUND One of the least researched areas in orthopaedic pediatrics is the safety and effectiveness of joint replacement, in part because it is uncommon and is undertaken for a wide range of conditions not common for adult joint replacement. This study used data from the AOANJRR (Australian Orthopaedic Association National Joint Replacement Registry) to analyze the use of total hip arthroplasty (THA) and total knee arthroplasty (TKA) in the pediatric population and to provide preliminary data on the outcome of these procedures. METHODS The AOANJRR, which is part of the ICOR (International Consortium of Orthopaedic Registries), provided information on pediatric procedures reported to the registry by hospitals undertaking arthroplasty procedures in Australia. All THA and TKA procedures reported to the registry from 1999 to 2012 were included. The cumulative percent revision and the hazard ratio from Cox proportional-hazards models were used for analysis. All tests were two-tailed, with a 5% level of significance. Additionally, an overview of the literature is presented to provide a point of reference. RESULTS Primary conventional THA was performed in 297 patients twenty years of age or younger; the cumulative percent revision at five years was 4.5%. Primary conventional THA was performed in 975 young adults twenty-one to thirty years of age; the cumulative percent revision at five years was 5.4%. Primary THA was performed in 105 patients twenty years of age or younger; the cumulative percent revision at five years was 4.6%. Primary TKA was performed in 159 young adults twenty-one to thirty years of age; the cumulative percent revision at five years was 10.3%. CONCLUSIONS Compared with older adults, pediatric patients and young adults undergoing THA and TKA have very different diagnoses, including a high prevalence of tumor. Although the reported rate of revision surgery is currently similar to that for older patients, the number of reported procedures and the follow-up period remain limited. It is important for registries to continue to collect and analyze data relevant to this cohort and to coordinate these activities in order to better understand the safety and effectiveness of joint arthroplasty in the pediatric population.


Journal of Bone and Joint Surgery, American Volume | 2014

Survivorship of hip and knee implants in pediatric and young adult populations: analysis of registry and published data.

Art Sedrakyan; Lucas Romero; Stephen Graves; David Davidson; Richard de Steiger; Peter L. Lewis; Michael J. Solomon; Robyn Vial; Michelle Lorimer

BACKGROUND One of the least researched areas in orthopaedic pediatrics is the safety and effectiveness of joint replacement, in part because it is uncommon and is undertaken for a wide range of conditions not common for adult joint replacement. This study used data from the AOANJRR (Australian Orthopaedic Association National Joint Replacement Registry) to analyze the use of total hip arthroplasty (THA) and total knee arthroplasty (TKA) in the pediatric population and to provide preliminary data on the outcome of these procedures. METHODS The AOANJRR, which is part of the ICOR (International Consortium of Orthopaedic Registries), provided information on pediatric procedures reported to the registry by hospitals undertaking arthroplasty procedures in Australia. All THA and TKA procedures reported to the registry from 1999 to 2012 were included. The cumulative percent revision and the hazard ratio from Cox proportional-hazards models were used for analysis. All tests were two-tailed, with a 5% level of significance. Additionally, an overview of the literature is presented to provide a point of reference. RESULTS Primary conventional THA was performed in 297 patients twenty years of age or younger; the cumulative percent revision at five years was 4.5%. Primary conventional THA was performed in 975 young adults twenty-one to thirty years of age; the cumulative percent revision at five years was 5.4%. Primary THA was performed in 105 patients twenty years of age or younger; the cumulative percent revision at five years was 4.6%. Primary TKA was performed in 159 young adults twenty-one to thirty years of age; the cumulative percent revision at five years was 10.3%. CONCLUSIONS Compared with older adults, pediatric patients and young adults undergoing THA and TKA have very different diagnoses, including a high prevalence of tumor. Although the reported rate of revision surgery is currently similar to that for older patients, the number of reported procedures and the follow-up period remain limited. It is important for registries to continue to collect and analyze data relevant to this cohort and to coordinate these activities in order to better understand the safety and effectiveness of joint arthroplasty in the pediatric population.


Anz Journal of Surgery | 2010

Controversies of thrombophylaxis following knee arthroplasty surgery

David Campbell; Paul Smith; Peter L. Lewis; Warwick Bruce

1. Lyell A. Toxic epidermal necrolysis: an eruption resembling scalded of the skin. Br. J. Dermatol. 1956; 68: 355–61. 2. Mcgee T, Munster A. Toxic epidermal necrolysis syndrome: mortality rate reduced with early referral to a regional burn center. Plast. Reconstr. Surg. 1998; 102: 1018–22. 3. Endorf FW, Cancio LC, Gibran NS. Toxic epidermal necrolysis clinical guidelines. J. Burn Care Res. 2008; 29: 706–12. 4. Cabral L, Riobom F, Diogo C, Teles L, Cruzeiro C. Toxic epidermal necrolysis – Lyell’s Syndrome. Ann. Burns Fire Disasters 2004; 17: 90–102. 5. French LE, Trent JT, Kerdel FA. Use of intravenous immunoglobulin in toxic epidermal necrolysis and Stevens-Johnson syndrome: our current understanding. Int. Immunopharmacol. 2006; 6: 543–9. 6. Shortt R, Gomez M, Mittman N, Cartotto R. Intravenous immunoglobulin does not improve outcome in toxic epidermal necrolysis. J. Burn Care Rehabil. 2004; 25: 246–55.


Acta Orthopaedica | 2018

The effect of surgeon’s preference for hybrid or cemented fixation on the long-term survivorship of total knee replacement: An analysis of 39,623 prostheses from the Australian Orthopaedic Association National Joint Replacement Registry

Christopher J. Vertullo; Stephen Graves; Yi Peng; Peter L. Lewis

Background and purpose — Recent direct comparative reports suggest that hybrid fixation may have a similar or superior outcome to cemented fixation in total knee replacement (TKR); however, a paucity of long-term data exists. To minimize the confounders of a direct comparison, we performed an instrumental variable analysis examining the revision rate of 2 cohorts of patients based on their surgeon’s preference for cemented or hybrid fixation. Methods — Registry data were obtained from 1999 until 2015 for 2 cohorts of patients who received minimally stabilized TKR, defined as those treated by high-volume hybrid fixation preferring surgeons, designated routinely hybrid (RH), and those treated by high-volume cemented fixation preferring surgeons, designated routinely cemented (RC). Results — At 13 years, the cumulative percentage revision of the RC cohort was 4.8% (CI 4.1–5.7) compared with 5.5% (CI 3.5–8.7) for the RH cohort. The revision risk for each cohort was the same for all causes (HR =1.0 (CI (0.84–1.20)), non-infective causes, and for infection. This finding was irrespective of patient age or sex, patella resurfacing, and with non-cross-linked polyethylene (NXLPE). The RH cohort who received cross-linked polyethylene (XLPE) had a lower revision risk than the RC cohort with XLPE (HR =0.57 (0.37–0.88), p = 0.01). Interpretation — The risk of revision for the patients of surgeons who prefer cemented fixation in minimally stabilized TKR is the same as for the patients of surgeons who prefer hybrid fixation, except when used with XLPE, where hybrid fixation has a lower revision risk.

Collaboration


Dive into the Peter L. Lewis's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michael J. Solomon

Royal Prince Alfred Hospital

View shared research outputs
Researchain Logo
Decentralizing Knowledge