Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Philipp Riffel is active.

Publication


Featured researches published by Philipp Riffel.


Investigative Radiology | 2013

CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): a new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution.

Henrik J. Michaely; John N. Morelli; Johannes Budjan; Philipp Riffel; Dominik Nickel; Randall Kroeker; Stefan O. Schoenberg; Ulrike I. Attenberger

PurposeThe purpose of this study was to assess the feasibility and image quality of a novel, highly accelerated T1-weighted sequence for time-resolved imaging of the abdomen during the first pass of contrast media transit using controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) under sampling, view-sharing techniques, and Dixon water-fat separation (CAIPRINHA–Dixon–time-resolved imaging with interleaved stochastic trajectories–volumetric interpolated breath-hold examination [CDT-VIBE]). Materials and MethodsIn this retrospective, institutional review board–approved study, 47 patients (median age, 62 years; 25 men, 22 women) scanned on a 3.0-T magnetic resonance system (Skyra; Siemens) were included. The CDT-VIBE (repetition time/echo time1/echo time2, 4.1/1.33/2.56 milliseconds; acquisition time, 29 seconds) was used in place of the standard arterial phase acquisition and started 15 seconds after the injection of 0.1 mmol/kg Gd-DOTA (Dotarem, Guerbet). Within 29 seconds, 14 high spatial resolution (1.2 × 1.2 × 3 mm3) 3-dimensional data sets were acquired and reconstructed using view sharing (temporal resolution, 2.1 seconds). The CDT-VIBE images were evaluated independently by 2 blinded, experienced radiologists with regard to image quality and the number of hepatic arterial–dominant phases present on an ordinal 5-point scale (5, excellent; 1, nondiagnostic). Added diagnostic information with CDT-VIBE relative to portal venous phase VIBE was assessed. ResultsIn all patients, CDT-VIBE measurements were successfully acquired. The image quality was diagnostic in 46 of the 47 patients. Both readers assessed the highest image quality present in the data sets with a median score of 4 (range, 3–5 for both readers; &kgr;, 0.789) and the worst image quality with a median score of 3 (range, 1–4 for both readers; &kgr;, 0.689). With a range between 1 and 8 (median, 5), hepatic arterial–dominant data sets (of the 14 acquired) were obtained in each case. There was an added diagnostic value with CDT-VIBE in 10 of the 47 patients (21%). ConclusionsThe CDT-VIBE is a robust approach allowing, for the first time, dynamic imaging of the upper abdomen with high temporal resolution and preservation of high spatial resolution.


Investigative Radiology | 2013

Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging.

Philipp Riffel; Ulrike I. Attenberger; Kannengiesser S; Arndt C; Mathias Meyer; So Schoenberg; Henrik J. Michaely

PurposeThe purpose of this study was to evaluate the feasibility and technical quality of an abdominal 3-dimensional interpolated breath-hold (volumetric interpolated breath-hold examination [VIBE]) magnetic resonance examination using the new parallel acquisition technique, controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA). Materials and MethodsIn this institutional review board–approved study, 15 volunteers underwent an abdominal magnetic resonance imaging examination including axial unenhanced 3-dimensional VIBE sequences with the conventional parallel acquisition technique, generalized autocalibrating partially parallel acquisitions parallel imaging (GRAPPA), with an acceleration factor (R) of 2, 3, 4, and 2 × 2 in comparison with a CAIPIRINHA-VIBE sequence with an acceleration factor of 2 × 2. Images were evaluated regarding the overall image quality, liver edge sharpness, and parallel imaging artifacts. Signal-to-noise ratio was evaluated using 2 different methods. In a second study population, 17 patients were examined with our new routine protocol for abdominal imaging that now comprises VIBE sequences with CAIPIRINHA with R = 2 × 2. ResultsIn the volunteer population, the overall image quality of CAIPIRINHA with R = 2 × 2 was significantly higher compared with GRAPPA with R = 3, 4, and 2 × 2 (P < 0.05). There were significantly less parallel imaging artifacts with CAIPIRINHA with R = 2 × 2 (P < 0.05). Acquisition time varied between 21.1 (GRAPPA with R = 2, 320 matrix) and 6.9 seconds (CAIPIRINHA with R = 2 × 2, 256 matrix). Signal-to-noise ratio performance of CAIPIRINHA with R = 2 × 2 was superior to GRAPPA with R = 3, 4, and 2 × 2. In the patient population, VIBE sequences with CAIPIRINHA with R = 2 × 2 showed consistently good image quality, minimal motion artifacts, and minimal parallel imaging artifacts. ConclusionsThe CAIPRINHA-VIBE with an acceleration factor of R = 2 × 2 is feasible in a clinical setting and is characterized by fast and robust imaging with an image quality comparable with a 2-fold acceleration with GRAPPA.


PLOS ONE | 2014

Zoomed EPI-DWI of the Pancreas Using Two-Dimensional Spatially-Selective Radiofrequency Excitation Pulses

Philipp Riffel; Henrik J. Michaely; John Morelli; Josef Pfeuffer; Ulrike I. Attenberger; Stefan O. Schoenberg; Stefan Haneder

Background Implementation of DWI in the abdomen is challenging due to artifacts, particularly those arising from differences in tissue susceptibility. Two-dimensional, spatially-selective radiofrequency (RF) excitation pulses for single-shot echo-planar imaging (EPI) combined with a reduction in the FOV in the phase-encoding direction (i.e. zooming) leads to a decreased number of k-space acquisition lines, significantly shortening the EPI echo train and potentially susceptibility artifacts. Purpose To assess the feasibility and image quality of a zoomed diffusion-weighted EPI (z-EPI) sequence in MR imaging of the pancreas. The approach is compared to conventional single-shot EPI (c-EPI). Material and Methods 23 patients who had undergone an MRI study of the abdomen were included in this retrospective study. Examinations were performed on a 3T whole-body MR system (Magnetom Skyra, Siemens) equipped with a two-channel fully dynamic parallel transmit array (TimTX TrueShape, Siemens). The acquired sequences consisted of a conventional EPI DWI of the abdomen and a zoomed EPI DWI of the pancreas. For z-EPI, the standard sinc excitation was replaced with a two-dimensional spatially-selective RF pulse using an echo-planar transmit trajectory. Images were evaluated with regard to image blur, respiratory motion artifacts, diagnostic confidence, delineation of the pancreas, and overall scan preference. Additionally ADC values of the pancreatic head, body, and tail were calculated and compared between sequences. Results The pancreas was better delineated in every case (23/23) with z-EPI versus c-EPI. In every case (23/23), both readers preferred z-EPI overall to c-EPI. With z-EPI there was statistically significantly less image blur (p<0.0001) and respiratory motion artifact compared to c-EPI (p<0.0001). Diagnostic confidence was statistically significantly better with z-EPI (p<0.0001). No statistically significant differences in calculated ADC values were observed between the two sequences. Conclusion Zoomed diffusion-weighted EPI leads to substantial image quality improvements with reduction of susceptibility artifacts in pancreatic DWI.


PLOS ONE | 2012

Implementation of Dual-Source RF Excitation in 3 T MR-Scanners Allows for Nearly Identical ADC Values Compared to 1.5 T MR Scanners in the Abdomen

Raghuram K. Rao; Philipp Riffel; Mathias Meyer; Paul Kettnaker; Andreas Lemke; Stefan Haneder; Stefan O. Schoenberg; Henrik J. Michaely

Background To retrospectively and prospectively compare abdominal apparent diffusion coefficient (ADC) values obtained within in a 1.5 T system and 3 T systems with and without dual-source parallel RF excitation techniques. Methodology/Principal Findings After IRB approval, diffusion-weighted (DW) images of the abdomen were obtained on three different MR systems (1.5 T, a first generation 3 T, and a second generation 3 T which incorporates dual-source parallel RF excitation) on 150 patients retrospectively and 19 volunteers (57 examinations total) prospectively. Seven regions of interest (ROI) were throughout the abdomen were selected to measure the ADC. Statistical analysis included independent two-sided t-tests, Mann-Whitney U tests and correlation analysis. In the DW images of the abdomen, mean ADC values were nearly identical with nonsignificant differences when comparing the 1.5 T and second generation 3 T systems in all seven anatomical regions in the patient population and six of the seven in the volunteer population (p>0.05 in all distributions). The strength of correlation measured in the volunteer population between the two scanners in the kidneys ranged from r = 0.64–0.88 and in the remaining regions (besides the spleen), r>0.85. In the patient population the first generation 3 T scanner had different mean ADC values with significant differences (p<0.05) compared to the other two scanners in each of the seven distributions. In the volunteer population, the kidneys shared similar ADC mean values in comparison to the other two scanners with nonsignificant differences. Conclusions/Significance A second generation 3 T scanner with dual-source parallel RF excitation provides nearly identical ADC values compared with the 1.5 T imaging system in abdominal imaging.


European Journal of Radiology | 2014

CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE) for dynamic liver imaging: Comparison of gadoterate meglumine, gadobutrol and gadoxetic acid

Johannes Budjan; Melissa Ong; Philipp Riffel; John Morelli; Henrik J. Michaely; Stefan O. Schoenberg; Stefan Haneder

PURPOSE CAIPIRINHA-Dixon-TWIST (CDT)-VIBE is a robust method for abdominal magnetic resonance imaging providing both high spatial and high temporal resolution. The purpose of this study was to examine the influence of different gadolinium based contrast agents (GBCA) on image quality (IQ) with CDT-VIBE. MATERIALS AND METHODS In this IRB-approved, retrospective, inter-individual comparison study, 86 patients scanned at 3T were included. Within 28s, 14 high-resolution 3D datasets were acquired using CDT-VIBE. 37 patients received 0.1mmol/kg gadoterate meglumine, 28 patients 0.1mmol/kg gadobutrol, and 19 patients 0.1mL/kg gadoxetic acid. Two blinded, board-certified radiologists assessed the image quality on a 5 point scale, as well as the number of hepatic arterial dominant (HAD) phases. RESULTS Regardless of the GBCA utilized, CDT-VIBE resulted in good IQ in terms of best IQ achieved among all 14 datasets (gadobutrol 4.3, gadoterate meglumine 3.9, gadoxetic acid 3.7). With respect to worst IQ, the three groups showed statistically significant differences with gadobutrol receiving the highest rating (3.6) and gadoxetic acid the lowest (2.4) (gadoterate meglumine 3.0; 0.0014<p<0.0485). No statistically significant differences were found in the mean number of acquired HAD phases (gadobutrol 3.4, gadoterate meglumine 3.9, gadoxetic acid 3.1; 0.18<p<0.57). CONCLUSION Different gadolinium-based contrast agents can be utilized for dynamic liver imaging with CDT-VIBE resulting in good image quality.


Zeitschrift Fur Medizinische Physik | 2016

Small Field-of-view single-shot EPI-DWI of the prostate: Evaluation of spatially-tailored two-dimensional radiofrequency excitation pulses

Ulrike I. Attenberger; Nils Rathmann; Metin Sertdemir; Philipp Riffel; Anja Weidner; Stefan Kannengiesser; John N. Morelli; Stefan O. Schoenberg; Daniel Hausmann

PURPOSE Spatially-tailored (RF) excitation pulses in echo-planar imaging (EPI), combined with a decreased FOV in the phase-encoding direction, enable a reduction of k-space acquisition lines, which shortens the echo train length (ETL) and reduces susceptibility artifacts. The purpose of this study was to evaluate the image quality of a zoomed EPI (z-EPI) sequence in diffusion-weighted imaging (DWI) of the prostate in comparison to a conventional single-shot EPI using single-channel (c-EPI1) and multi-channel (c-EPI2) RF excitation, with and without use of an endorectal coil. MATERIALS AND METHODS 33 consecutive patients (mean age: 61 +/- 9 years; mean PSA: 8.67±6.23 ng/ml) with examinations between 10/2012 and 02/2014 were analyzed in this retrospective study. In 26 of 33 patients the initial multiparametric (mp)-MRI was performed on a whole-body 3T scanner (Magnetom Trio, Siemens, Erlangen, Germany) using an endorectal coil (c (conventional)-EPI1). Zoomed-EPI (Z-EPI) examinations of these patients and a complete mp-MRI protocol including c-EPI2 of 7 additional patients were carried out on another 3T wb MR scanner with two-channel dynamic parallel transmit capability (Magnetom Skyra with TimTX TrueShape, Siemens). For z-EPI, the one-dimensional spatially selective RF excitation pulse was replaced by a two-dimensional RF pulse. Degree of image blur and susceptibility artifacts (0=not present to 3= non-diagnostic), maximum image distortion (mm), apparent diffusion coefficient (ADC) values, as well as overall scan preference were evaluated. SNR maps were generated to compare c-EPI2 and z-EPI. RESULTS Overall image quality of z-EPI was preferred by both readers in all examinations with a single exception. Susceptibility artifacts were rated significantly lower on z-EPI compared to both other methods (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01) as well as image blur (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01). Image distortion was not statistically significantly reduced with z-EPI (z-EPI vs c-EPI1: p=0.12; z-EPI vs c-EPI2: p=0.42). Interobserver agreement for ratings of susceptibility artifacts, image blur and overall scan preference was good. SNR was higher for z-EPI than for c-EPI1 (n=1). CONCLUSION Z-EPI leads to significant improvements in image quality and artifacts as well as image blur reduction improving prostate DWI and enabling accurate fusion with conventional sequences. The improved fusion could lead to advantages in the field of MRI-guided biopsy suspicous lesions and performance of locally ablative procedures for prostate cancer.


Investigative Radiology | 2016

One-Stop Shop: Free-Breathing Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Kidney Using Iterative Reconstruction and Continuous Golden-Angle Radial Sampling.

Philipp Riffel; Frank G. Zoellner; Johannes Budjan; Robert Grimm; Tobias K. Block; Stefan O. Schoenberg; Daniel Hausmann

Aims and ObjectivesThe purpose of the present study was to evaluate a recently introduced technique for free-breathing dynamic contrast-enhanced renal magnetic resonance imaging (MRI) applying a combination of radial k-space sampling, parallel imaging, and compressed sensing. The technique allows retrospective reconstruction of 2 motion-suppressed sets of images from the same acquisition: one with lower temporal resolution but improved image quality for subjective image analysis, and one with high temporal resolution for quantitative perfusion analysis. Materials and MethodsIn this study, 25 patients underwent a kidney examination, including a prototypical fat-suppressed, golden-angle radial stack-of-stars T1-weighted 3-dimensional spoiled gradient-echo examination (GRASP) performed after contrast agent administration during free breathing. Images were reconstructed at temporal resolutions of 55 spokes per frame (6.2 seconds) and 13 spokes per frame (1.5 seconds). The GRASP images were evaluated by 2 blinded radiologists. First, the reconstructions with low temporal resolution underwent subjective image analysis: the radiologists assessed the best arterial phase and the best renal phase and rated image quality score for each patient on a 5-point Likert-type scale.In addition, the diagnostic confidence was rated according to a 3-point Likert-type scale. Similarly, respiratory motion artifacts and streak artifacts were rated according to a 3-point Likert-type scale.Then, the reconstructions with high temporal resolution were analyzed with a voxel-by-voxel deconvolution approach to determine the renal plasma flow, and the results were compared with values reported in previous literature. ResultsReader 1 and reader 2 rated the overall image quality score for the best arterial phase and the best renal phase with a median image quality score of 4 (good image quality) for both phases, respectively. A high diagnostic confidence (median score of 3) was observed. There were no respiratory motion artifacts in any of the patients. Streak artifacts were present in all of the patients, but did not compromise diagnostic image quality.The estimated renal plasma flow was slightly higher (295 ± 78 mL/100 mL per minute) than reported in previous MRI-based studies, but also closer to the physiologically expected value. ConclusionsDynamic, motion-suppressed contrast-enhanced renal MRI can be performed in high diagnostic quality during free breathing using a combination of golden-angle radial sampling, parallel imaging, and compressed sensing. Both morphologic and quantitative functional information can be acquired within a single acquisition.


European Journal of Radiology | 2012

Combined large field-of-view MRA and time-resolved MRA of the lower extremities: Impact of acquisition order on image quality

Philipp Riffel; Stefan Haneder; Ulrike I. Attenberger; Joachim Brade; Stefan O. Schoenberg; Henrik J. Michaely

PURPOSE Different approaches exist for hybrid MRA of the calf station. So far, the order of the acquisition of the focused calf MRA and the large field-of-view MRA has not been scientifically evaluated. Therefore the aim of this study was to evaluate if the quality of the combined large field-of-view MRA (CTM MR angiography) and time-resolved MRA with stochastic interleaved trajectories (TWIST MRA) depends on the order of acquisition of the two contrast-enhanced studies. METHODS In this retrospective study, 40 consecutive patients (mean age 68.1 ± 8.7 years, 29 male/11 female) who had undergone an MR angiographic protocol that consisted of CTM-MRA (TR/TE, 2.4/1.0 ms; 21° flip angle; isotropic resolution 1.2mm; gadolinium dose, 0.07 mmol/kg) and TWIST-MRA (TR/TE 2.8/1.1; 20° flip angle; isotropic resolution 1.1mm; temporal resolution 5.5s, gadolinium dose, 0.03 mmol/kg), were included. In the first group (group 1) TWIST-MRA of the calf station was performed 1-2 min after CTM-MRA. In the second group (group 2) CTM-MRA was performed 1-2 min after TWIST-MRA of the calf station. The image quality of CTM-MRA and TWIST-MRA were evaluated by 2 two independent radiologists in consensus according to a 4-point Likert-like rating scale assessing overall image quality on a segmental basis. Venous overlay was assessed per examination. RESULTS In the CTM-MRA, 1360 segments were included in the assessment of image quality. CTM-MRA was diagnostic in 95% (1289/1360) of segments. There was a significant difference (p<0.0001) between both groups with regard to the number of segments rated as excellent and moderate. The image quality was rated as excellent in group 1 in 80% (514/640 segments) and in group 2 in 67% (432/649), respectively (p<0.0001). In contrast, the image quality was rated as moderate in the first group in 5% (33/640) and in the second group in 19% (121/649) respectively (p<0.0001). The venous overlay was disturbing in 10% in group 1 and 20% in group 2 (p=n.s.). CONCLUSION If a combined hybrid MRA approach with large field-of-view and time-resolved MRA is acquired the large field-of-view MRA should be acquired first in order for optimal image quality.


Investigative Radiology | 2015

Fifty Years of Technological Innovation: Potential and Limitations of Current Technologies in Abdominal Magnetic Resonance Imaging and Computed Tomography.

Ulrike I. Attenberger; John N. Morelli; Johannes Budjan; Thomas Henzler; Steven Sourbron; Michael Bock; Philipp Riffel; Diego Hernando; Melissa Ong; Stefan O. Schoenberg

AbstractMagnetic resonance imaging (MRI) has become an important modality for the diagnosis of intra-abdominal pathology. Hardware and pulse sequence developments have made it possible to derive not only morphologic but also functional information related to organ perfusion (dynamic contrast-enhanced MRI), oxygen saturation (blood oxygen level dependent), tissue cellularity (diffusion-weighted imaging), and tissue composition (spectroscopy). These techniques enable a more specific assessment of pathologic lesions and organ functionality. Magnetic resonance imaging has thus transitioned from a purely morphologic examination to a modality from which image-based disease biomarkers can be derived. This fits well with several emerging trends in radiology, such as the need to accurately assess response to costly treatment strategies and the need to improve lesion characterization to potentially avoid biopsy. Meanwhile, the cost-effectiveness, availability, and robustness of computed tomography (CT) ensure its place as the current workhorse for clinical imaging. Although the lower soft tissue contrast of CT relative to MRI is a long-standing limitation, other disadvantages such as ionizing radiation exposure have become a matter of public concern. Nevertheless, recent technical developments such as dual-energy CT or dynamic volume perfusion CT also provide more functional imaging beyond morphology.The aim of this article was to review and discuss the most important recent technical developments in abdominal MRI and state-of-the-art CT, with an eye toward the future, providing examples of their clinical utility for the evaluation of hepatic and renal pathologies.


European Journal of Radiology | 2016

Carotid dual-energy CT angiography: Evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels

Philipp Riffel; Holger Haubenreisser; Mathias Meyer; Sonja Sudarski; John N. Morelli; Bernhard Schmidt; Stefan O. Schoenberg; Thomas Henzler

BACKGROUND AND PURPOSE Calculated monoenergetic ultra-low keV datasets did not lead to improved contrast-to-noise ratio (CNR) due to the dramatic increase in image noise. The aim of the present study was to evaluate the objective image quality of ultra-low keV monoenergetic images (MEIs) calculated from carotid DECT angiography data with a new monoenergetic imaging algorithm using a frequency-split technique. MATERIALS AND METHODS 20 patients (12 male; mean age 53±17 years) were retrospectively analyzed. MEIs from 40 to 120 keV were reconstructed using the monoenergetic split frequency approach (MFSA). Additionally MEIs were reconstructed for 40 and 50 keV using a conventional monoenergetic (CM) software application. Signal intensity, noise, signal-to-noise ratio (SNR) and CNR were assessed in the basilar, common, internal carotid arteries. RESULTS Ultra-low keV MEIs at 40 keV and 50 keV demonstrated highest vessel attenuation, significantly greater than those of the polyenergetic images (PEI) (all p-values <0.05). The highest SNR level and CNR level was found at 40 keV and 50 keV (all p-values <0.05). MEIs with MFSA showed significantly lower noise levels than those processed with CM (all p-values <0.05) and no significant differences in vessel attenuation (p>0.05). Thus MEIs with MFSA showed significantly higher SNR and CNR compared to MEIs with CM. CONCLUSION Combining the lower spatial frequency stack for contrast at low keV levels with the high spatial frequency stack for noise at high keV levels (frequency-split technique) leads to improved image quality of ultra-low keV monoenergetic DECT datasets when compared to previous monoenergetic reconstruction techniques without the frequency-split technique.

Collaboration


Dive into the Philipp Riffel's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

C. Bolenz

Heidelberg University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John Morelli

Johns Hopkins University School of Medicine

View shared research outputs
Researchain Logo
Decentralizing Knowledge